FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ELCON Systemtechnik GmbH/
  3. R3V6618B

R3V6618BEasyTrack 6618B

ELCON Systemtechnik GmbH
EasyTrack 6618B - FCC ID R3V6618B - ELCON Systemtechnik GmbH
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Aug 22, 2004
Application Purpose
Original Equipment
Date of Application
Aug 22, 2004
Equipment Note
EasyTrack 6618B
Frequency Range
1850.20000000 - 1909.80000000
Company
ELCON Systemtechnik GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Eas yTr ack Version: 2004/06/17 Page 1 EasyTrack E LCON B A SIC SY STEM FOR TRACK ING DATA Operating Manual Order No.: 9537-1 IMPORTANT NOTES Eas yTr ack Version: 2004/06/17 Page 2 NOTICE This device contains 900 MHz/1800 MHz GSM functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations. Statement according to FCC part 15.19: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that m ay cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. Statement according to FCC part 15.105: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help. RF Exposure mobile: The external antennas used for this mobile transmitter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. IMPORTANT NOTES Eas yTr ack Version: 2004/06/17 Page 3 Dear customer: ELCON Systemtechnik would like to thank you for your confidence when purchasing the onboard unit EasyTrack . This User Manual is intended to help you to activate your EasyTrack and the EasyTrack Manager as quickly as possible. It provides you with a brief description of setup under Windows ® operation systems. Please make sure to read this user manual carefully, before you bring the unit into service! Familiarize with the operation and functions of EasyTrack . Keep the user manual and other descriptive documentation for your reference. Should you still have questions as this manual might not cover all details, our service partner will be happy to help you. This user manual is subject to change without notice. Windows ®, Windo ws NT ® and Microsoft ® are registered trademarks of Microsoft Corp. SAFETY INSTRUCTIONS Eas yTr ack Version: 2004/06/17 Page 4 Safety Notes Before installing and starting the device, read the information given in the operating manual most carefully. In doing so, you will take advantage of the device’s full scope of functions and avoid damages due to improper use. • The device reflects the current state of the art and complies with the applicable safety standards. • Operate the device only in proper condition and strictly according to the operating instructions. • Works on the device, including its opening, must only be done by authorized service personnel. • For the electrical connection of the device, ensure the correct line voltage (see chapter Technical Data)! • Always disconnect the device from mains before you open it! • In the event of failure, please contact the manufacturer or your agency in charge. • O nly end devices complying with the safety standard according to EN 60950 and bearing the CE-mark, are permitted to be connected to the interfaces of the device. • The end devices must have suitable plug connections, otherwise appropriate adapters are to be used. • End devices must only be operated at the interfaces provided for. Besides the safety notes mentioned above, you will find complementary installation instructions in the according chapters. This operating manual is subject to change without notice. For any further questions relating to the configuration and installation of your device, please refer to the manufacturer. TABLE CONTENTS Eas yTr ack Version: 2004/06/17 Page 5 1 Introduction ............................................ 6 1.1 Practical application of EasyTrack................ 6 1.2 Symbols used in this manual ....................... 6 1.3 System requirements for installation............. 7 2 Installation .............................................. 7 2.1 Scope of supply ........................................ 8 2.1.1 Vehicle equipment..................................... 8 2.1.2 Office equipment ....................................... 8 2.1.3 Optional Accessories ................................. 9 2.2 Insertion of SIM card.................................. 9 2.3 Installation position and fastening .............. 10 2.4 Connection options.................................. 10 2.5 Installation of the device ........................... 11 2.6 Installation instructions ............................. 12 2.7 Serial Interface (RS232) ........................... 13 3 Relevance of the LEDs ........................... 14 4 EasyTrack M anager ............................... 15 4.1 General Information................................. 15 4.2 Summary of functionalities........................ 15 4.3 System Requirements.............................. 15 4.4 First Steps ............................................. 16 4.5 Installation / Deinstallation ........................ 17 4.6 Uninstall EasyTrack Manager.................... 18 4.7 Working with EasyTrac…

Text truncated - open the document above for the full version.

External Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 1 of 16 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 2 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 3 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 4 of 16

Internal Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 5 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 6 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 7 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 8 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 9 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 10 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 11 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 12 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 13 of 16

Test Report

ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 24 Test report no.: G0M20405-8725-P-24 FCC ID: R3V6618B FCC ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 66 ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 1 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 3 Test Results 4 RF Power Output, FCC 2.1046 4.1 Test Procedure 4.2 Test Results 5 Radiated Power, FCC 24.232 5.1 Test Procedure 5.2 Test Results 6 Occupied Bandwidth, FCC 2.1049 6.1 Test Procedure 6.2 Test Results 7 Field Strength of Spurious Radiations, FCC 2.1053, 24.238 7.1 Test Procedure 7.2 Test Results 8 Line Conducted Emissions, FCC 15.207 8.1 Test Procedure 8.2 Test Results 9 Frequency Stability vs Temperature, FCC 2.1055, 24.235 9.1 Test Procedure 9.2 Test Results 10 Frequency Stability vs Voltage, FCC 2.1055, 24.235 10.1 Test Procedure 10.2 Test Equipment ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 2 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 16.06.2004 N. Kaspar Date ETS-Lab. Name Signature Technical responsibility for area of testing: 16.06.2004 Dr. Genz Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 3 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 660 1.2.2 Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY: BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number: 1983-01 1.3 Details of approval holder Name : ELCON Systemtechnik GmbH Street : Obere Hauptstrasse 10 Town : 09232 Hartmannsdorf Country : Germany Telephone : 03722 / 7351-212 Fax : 03722 / 6160 Contact : Herr Hans Georg Rademacher Email : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 4 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 17.05.2004 Date of receipt of test item : 17.05.2004 Date of test : 10.06.2004 1.5 Test item Description of test item : ELCON BASIC SYSTEM FOR TRACKING DATA Type identification : Easy Track 6618 Sample B Serial number : Test model without serial number. Photos : See annex A Technical data Frequency range Tx : 1850.2 - 1909.8 MHz Frequency range Rx : 1930.2 – 1989.8 MHz Antenna transmitter : external antenna Antenna type . MCA 1890 multiband antenna with unique connector Antenna Gain : 2.1 dBi Power supply : 24 V DC Operating mode : duplex Type of modulation : GMSK (GSM modulation) Emission : GXW Manufacturer: (if applicable) Name : Street : Town : Country : Additional information : none ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 5 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC Part 24 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests … performed. 2.2 Test environment Temperature : 23 o C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa Extreme temperature : -30 / 50 °C ETS Dr. Genz GmbH, Germany Registration number: G0M20405-8725-P-24 Page 6 of 26 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment utilized No. Measurement device:Type:Manufacturer: ETS 0001 Test receiverESHS 10Rohde&Schwarz ETS 0002 Test receiverESVPRohde&Schwarz ETS 0003 Test receiverESVS 10Rohde&Schwarz ETS 0004 Spectrum- and Network-AnalyzerFSMS 26Rohde&Schwarz ETS 0005 Test receiverSMV 11MEB ETS 0006 Test receiver system SME 12MEB ETS 0007 Spectrum analyzer PSA-65AAvcom ETS 0008 Antenna Loop antennaSiemens ETS 0009 Antenna Loop antennaMEB ETS 0010 Antenna Loop antennaMEB ETS 0011 Antenna van Veen/ FrameETS ETS 0012 Antenna HK 116Rohde&Schwarz ETS 0013 Antenna HL 223Rohde&Schwarz ETS 0014 Antenna HL 025Rohde&Schwarz ETS 0015 Antenna HL 025Rohde&Schwarz ETS 0016 Antenna VHAPSchwarzbeck ETS 0017 Antenna VHAPSchwarzbeck ETS 0018 Antenna UHAPSchwarzbeck ETS 0019 Antenna UHAPSchwarzbeck ETS 0020 Antenna DP 21MEB ETS 0021 Antenna DP 3MEB ETS 0022 Antenna S…

Text truncated - open the document above for the full version.

Test Setup Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 14 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 15 of 16 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20404-8725-P-24 Page 16 of 16

Contact Information

Applicant

Hans Georg Rademacher
[email protected]04937227351212Fax: 049372273516160

Technical Contact

ELCON Mobility GmbHHartmut Reusch
[email protected]+49(0)30/46407-164

Voltastrasse 5 · Berlin · Germany

Non-Technical Contact

ELCON Systemtechnik GmbHHans Georg Rademacher
[email protected]+49(0)3722/7351-212

Test Firm

Eurofins Product Service GmbHRobert Kschiwan-Kaspar
[email protected]49-33631-888-000Fax: 49-33631-888-660

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz659.00 mW250KGXW1.0000000000 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is conducted for Part 24. The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of �2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 2.1dBi for mobile operation.

Other Applications from ELCON Systemtechnik GmbH

E-TRIP � 6600 - FCC ID R3V6600 - ELCON Systemtechnik GmbH
R3V6600

E-TRIP � 6600

Aug 16, 2004

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
EasyTrack 6618A - FCC ID R3V6618A - ELCON Systemtechnik GmbH
R3V6618A

EasyTrack 6618A

Jun 13, 2004

Equipment Class

PCB - PCS Licensed Transmitter