User Guide 2 of 65 PREFACE This user guide provides information for the use and operation of the iRISupply™ Cabinet System. This user guide is considered a permanent part of the iRISupply™ Cabinet System, and should remain with the iRISupply™ Cabinet System at all times. The information and specifications included in this publication were in effect at the time of approval for printing. Mobile Aspects reserves the right, however, to discontinue or change specifications or design at anytime without notice and without incurring any obligation whatever. No part of this publication may be reproduced without written permission. 3 of 65 Revision History Date Version Description Author 05/11/04 1.0 Original Version K. Yu 02/12/05 2.0 Updated for Software Release 3.4 T. Sriharto 02/24/05 2.1 Updated J. Banyas 01/25/06 2.2 Updated J. Banyas 10/17/07 2.3 Updated A. Kearns 07/20/11 2.4 Added Certification Language K. Le 4 of 65 Technical Support In the U.S.A., customers can reach the Mobile Aspects Technical Assistance Center (TAC) in three different ways. 1. Telephone questions to the TAC at: (888) 221-7571 2. Email questions to the TAC at: [email protected] 3. Fax questions to the TAC at: (412) 325-1685 5 of 65 Table of Contents Technical Support ................................................................................................................................................................ 4 IMPORTANT NOTICE 7 TYPE APPROVALS 7 GENERAL SAFETY INFORMATION 7 Safety and Warning Symbols ................................................................................................................................................ 7 Environmental Conditions ..................................................................................................................................................... 8 Maintenance and Cleaning .................................................................................................................................................... 8 Electrical Rating ..................................................................................................................................................................... 9 IRISUPPLY USER LOG-IN 10 Magnetic Stripe Card ........................................................................................................................................................... 10 Process Flow Description ................................................................................................................................................... 10 Proximity Card ..................................................................................................................................................................... 13 Process Flow Description ................................................................................................................................................... 13 Bar Code ............................................................................................................................................................................... 14 Process Flow Description ................................................................................................................................................... 14 On Screen Keypad ................................................................................................................................................................ 15 Process Flow Description ................................................................................................................................................... 15 PATIENT LIST FUNCTIONALITY 17 Selecting a Patient ................................................................................................................................................................ 17 Patient List Screen .............................................................................................................................................................. 17 Workflow Description ........................................................................................................................................................ 19 Operations Tabs ................................................................................................................................................................... 22 1.1.1. Patient Tab ........................................................................................................................................................ 22 1.1.2. Status Tab ......................................................................................................................................................... 23 1.1.3. Usage Tab ......................................................................................................................................................... 23 1.1.4. Alert Tab ........................................................................................................................................................... 23 1.1.5. Logout Tab ........................................................................................................................................................ 23 Sorting the Patient List ........................................................................................................................................................ 23 Patient List Sort Screen ...................................................................................................................................................... 24 Workflow Description ........................................................................................................................................................ 25 6 of 65 Searching the Patient List .....................................................................................................................................…
Text truncated - open the document above for the full version.
June 23, 2011 Michael Buchholz Curtis-Straus LLC Littleton Distribution Center One Distribution Center Circle, Suite 1 Littleton, MA 01460 RE: PROFESSIONAL INSTALLATION ATTESTATION FOR FCC ID: R4FIRISUPPLY50 We hereby attest that our product with the FCC ID above will only be configured and installed by professional installers. This device is not intended to be used by the general public; therefore it will not be sold to the general public through retail stores or any other means. Distribution will be controlled and it will be installed only by us or by our partners who hire professionals that have knowledge in the installation of RF devices to meet local and government regulations. Khang Le VP of Engineering
Request for Confidentiality June 23, 2011 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 Curtis-Straus LLC TCB Littleton Distribution Center One Distribution Center Circle, Suite 1 Littleton, MA 01460 Re: Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457(d)(2) pertaining to confidential material. Mobile Aspects Inc. requests that the following documents regarding this submission for FCC ID R4FIRISUPPLY50 be kept confidential: 1. Schematics 2. Block Diagram 3. Circuit/Technical Description The material above contains technical data, which would customarily be guarded from competitors. Sincerely, Khang Le VP of Engineering
June 23, 2011 To: Curtis-Straus LLC Certification Department One Distribution Center Circle, Suite #1 Littleton, MA 01460 Authority to Act as Agent On our behalf, I appoint Curtis-Straus LLC, One Distribution Center Circle, Suite #1, Littleton, MA 01460 USA to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Mobile Aspects, Inc., 24 South 18 th St., Suite 300, Pittsburgh, PA 15203 USA. Dated this 23 rd Day of June 20 11 Agency agreement expiration date: 06/23/2012 By: Khang Le Signature Printed Title: VP of Engineering On behalf of : Mobile Aspects, Inc. Telephone: (412) 325-1690
EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs EL0846-1 Mobile Aspects External Photographs
115VAC, 60 Hz, 4.4A Max iRISupply 5.0 FCC ID: R4FIRISUPPLY50 MADE IN U.S.A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. MODEL: INPUT: // M O B I L E // A S P E C T S // Tested to UL/CSA 60950-1 2nd Ed ELAA
EL0846-1 Mobile Aspects Internal Photographs Antenna A2 – Catheter Antenna EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs Antenna A1 – Standard Antenna EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs RF Module Main Controller (Front) Main Controller ( Rear) Computer Chassis (located at base of cabinet) EL0846-1 Mobile Aspects Internal Photographs Main Controller RF Module EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs EL0846-1 Mobile Aspects Internal Photographs
Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. ____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 1 of 18 Test Report bb Curtis-Straus LLC, a wholly owned subsidiary of BV CPS Report No EL0846-1 Client Mobile Aspects Khang Le Address 24 South 18 th Suite 300 Pittsburgh, PA 15203 Phone 412-325-1690 Items tested iRISupply 5.0 RFID supply cabinet system FCC ID R4FIRISUPPLY50 FRN 0010877447 Standards FCC 47 CFR Part 15.225 Test Dates June 21 st , 22 rd , and August 9 th , 2011 Results As detailed within this report Prepared by John Cushing– Test Engineer Authorized by Mairaj Hussain – EMC Supervisor Issue Date August 11, 2011 Conditions of Issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 17 of this report. Test Report for Mobile Aspects • •• • Report No. EL0846-1 August 2, 2010 ______________________________________________________________________ ____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 • •• • Littleton, MA • •• • TEL (978) 486-8880 • FAX (978) 486-8828 page 2 of 18 Contents Contents..................................................................................................................................2 Summary.................................................................................................................................3 Test Methodology ....................................................................................................................3 Statement of Conformity ..........................................................................................................4 EUT Configuration ...................................................................................................................5 Fundamental Measurements ...................................................................................................6 Radiated Spurious Emissions ..................................................................................................8 AC Line Conducted Emission Measurements........................................................................11 Measurement Uncertainty......................................................................................................12 Test Equipment Used ............................................................................................................13 Jurisdictional Labeling and Required Instruction Manual Inserts ........................................14 FCC Requirements ............................................................................................................14 Conditions Of Testing ............................................................................................................17 Form Final Report REV 8-18-08 (DW) Test Report for Mobile Aspects • •• • Report No. EL0846-1 August 2, 2010 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 3 of 18 Summary This test report supports an application for certification of a transmitter operating pursuant to 47 CFR 15.225. The product is the Mobile Aspects iRISupply 5.0 RFID supply cabinet system. The transmitter operates at 13.56MHz. The unit consists of a master cabinet and as many as six auxiliary cabinets, each containing one of two possible antennas. Under operation, only one antenna will function at a time, so a two-cabinet system utilizing one of each type of antenna was used for testing. Fundamental readings were taken on both antennas, and spurious emissions were taken on the worst offender. The transmitter used is the FEIG Electronic ID ISC.LRM2500-A/B Reader Module (FCC ID PJMLRM2500). Frequency stability was not performed on the iRISupply 5.0 because Mobile Aspects uses the FEIG radio with their own antennas. The test report for the FEIG radio is attached with this application. Test Methodology Radiated emission testing was performed according to the procedures specified in ANSI C63.4 (2003). Emissions were maximized by rotating the system around its vertical axis as well as varying the test antenna’s height and polarity. The EUT antenna was maximized separately by varying the height at which it was installed in the cabinet. Frequency range investigated: 0.009MHz – 10.6GHz Measurement distance: 0.15 - 30MHz Conducted 0.09 – 30MHz 3m (loop antenna) 30MHz – 10.6GHz 3m AC Line conducted emissions testing was performed with a 50Ω/50μH LISN. Test Report for Mobile Aspects • •• • Report No. EL0846-1 August 2, 2010 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 4 of 18 Statement of Conformity The iRISupply 5.0 RFID supply cabinet system has been found to conform to the following parts of 47 CFR as detailed below: Part 2 Part 15 Comments 15.15(b) There are no controls accessible to the user that vary the output power. 2.925 15.19 The label is shown in the label exhibit. 15.21 Information to the user is shown in the instruction manual exhibit. 15.27 No special accessories are required for compliance. 15.31(e) Frequency stability and voltage variation were performed on the system. Pl…
Text truncated - open the document above for the full version.
Test report no. 11006760 Page 1 of 39 EUT: ID ISC.LRM2500-B and ID ISC.LRM2500-A FCC ID: PJMLRM2500 Date of issue: 2011-03-28 Date: 2011-03-14 Vers. no. 1.11 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to FEIG ELECTRONIC GmbH ID ISC.LRM2500-B and ID ISC.LRM2500-A Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 11006760 Page 2 of 39 EUT: ID ISC.LRM2500-B and ID ISC.LRM2500-A FCC ID: PJMLRM2500 Date of issue: 2011-03-28 Date: 2011-03-14 Vers. no. 1.11 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Manufacturer’s details Manufacturer FEIG ELECTRONIC GmbH Manufacturer’s grantee code PJM Manufacturer’s address Lange Str.4 35781 Weilburg Germany Phone: +49 (0) 6471 31 09 0 Fax: +49 (0) 6471 31 09 99 Contact: Mr. Wolfgang Meißner Email: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2009 Test Report prepared by Technical engineer Ralf Trepper m. dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 2207 96890 Fax: +49 2207 968920 Email: [email protected] Equipment Under Test (EUT) Equipment category Inductive application / RFID Trade name OBID i-scan Type designation ID ISC.LRM2500-B Serial no. --- Variants ID ISC.LRM2500-A Antennas ID ISC.ANT310/310 ID ISC.ANT800/600 ID ISC.ANT1690/600 ID ISC.ANT1700/740 ID ISC.ANT1700/740 SLx ID ISC.ANT1800/700 Test report no. 11006760 Page 3 of 39 EUT: ID ISC.LRM2500-B and ID ISC.LRM2500-A FCC ID: PJMLRM2500 Date of issue: 2011-03-28 Date: 2011-03-14 Vers. no. 1.11 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 1. Test results Clause Requirements headline Test result Report page number 8.1 Antenna Requirement Pass Fail N.t.* 10 8.2 Restricted bands of operation Pass Fail N.t.* 11 to 12 8.3 Conducted limits Pass Fail N.t.* 13 to 17 8.4 Radiated emission limits Pass Fail N.t.* 18 to 34 8.5 Frequency tolerance Pass Fail N.t.* 35 to 37 * Not tested The equipment meets the requirements Yes No Signature: ............................. Signature: ............................. (Technician) (Manager) Test report no. 11006760 Page 4 of 39 EUT: ID ISC.LRM2500-B and ID ISC.LRM2500-A FCC ID: PJMLRM2500 Date of issue: 2011-03-28 Date: 2011-03-14 Vers. no. 1.11 dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Table of contents 1. Test results ........................................................................................................................................................ 3 2. Introduction ...................................................................................................................................................... 5 3. Testing laboratory ............................................................................................................................................ 5 4. Applicant .......................................................................................................................................................... 6 5. Product and product documentation ................................................................................................................ 6 6. Conclusions, observations and comments ........................................................................................................ 7 7. Operational description ...................................................................................................................................... 8 8. Compliance assessment ..................................................................................................................................... 10 8.1 Antenna requirement ....................................................................................................................................... 10 8.1.1 Regulation ............................................................................................................................................. 10 8.1.2 Result .................................................................................................................................................... 10 8.2 Restricted bands of operation ......................................................................................................................... 11 8.2.1 Regulation ............................................................................................................................................. 11 8.2.2 Result .................................................................................................................................................... 12 8.3 Conducted limits ............................................................................................................................................ 13 8.3.1 Regulation ............................................................................................................................................. 13 8.3.2 Test equipment ...................................................................................................................................... 14 8.3.3 Test procedures ..................................................................................................................................... 14 8.3.4 Result .................................................................................................................................................... 15 8.4 Radiated emission limits ................................................................................................................................ 18 8.4.1 Regulation .............................…
Text truncated - open the document above for the full version.
EL0846-1 Mobile Aspects Test Setup Photographs AC Line Conducted Measurements - Front EL0846-1 Mobile Aspects Test Setup Photographs AC Line Conducted Measurements - Rear EL0846-1 Mobile Aspects Test Setup Photographs Radiated Emission Measurements EL0846-1 Mobile Aspects Test Setup Photographs Radiated Emissions Measurements – above 30MHz EL0846-1 Mobile Aspects Test Setup Photographs Radiated Emissions Measurements – above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

RFID Cabinet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Cabinet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RFID Cabinet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Low Power Communication Device Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter