Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
EdgePoint PRO Installation Guide Version 1.0 February 2011 Prepared By AirWalk Communications, Inc. 1830 North Greenville Ave Richardson, TX, 75081 Phone: (972) 638-9400 Fax: (972) 638-9401 www.airwalkcom.com FOR USE BY TRAINED TECHNICIANS ONLY EdgePoint PRO Installation Guide ______________________________________________________________________________ AirWalk Proprietary and Confidential Page 2 of 19 Revision History Version Date Person Description 0.1 01/04/2011 R MacLennan Initial Draft Document 0.2 02/04/2011 R Campman Added Plug and Play section 0.3 02/10/2011 A Sridhar Added Cluster info, LED deciphering section 1.0 Review changes EdgePoint PRO Installation Guide ______________________________________________________________________________ AirWalk Proprietary and Confidential Page 3 of 19 Contents 1 Introduction ..................................................................................................... 4 1.1 Proprietary Information Notice ....................................................................... 4 1.2 Purpose ...................................................................................................... 4 1.3 Scope ......................................................................................................... 4 2 Acronyms ......................................................................................................... 5 3 eFemto Safety and Compliance Information .......................................................... 6 3.1 Statement of Intent...................................................................................... 6 3.2 Safety Precautions ....................................................................................... 6 3.3 Regulatory Compliance Information ................................................................ 6 3.3.1 Radio Interference (FCC 15.19 Statement) ................................................ 7 3.3.2 Unauthorized Modifications (FCC 15.21 Statement) ..................................... 7 3.3.3 Digital Device Interference (FCC 15.105 Statement) ................................... 7 4 eFemto Device Installation .................................................................................. 8 4.1 Overview .................................................................................................... 8 4.2 eFemto Network Diagram .............................................................................. 9 4.2.1 Network Requirements ......................................................................... 10 4.3 Hardware Configuration .............................................................................. 11 5 Installation Steps ............................................................................................ 13 5.1 Contents within the Installation Kit ............................................................... 13 5.2 eFemto Location for Installation ................................................................... 14 5.3 Mount Bracket to Wall ................................................................................ 15 5.4 Position Power Supply, Cables and Antennas .................................................. 15 5.5 Secure eFemto to Bracket and Connect Cables ............................................... 16 5.6 Powering Up the eFemto ............................................................................. 17 5.7 eFemto Plug and Play Feature ...................................................................... 17 5.8 Deciphering eFemto LEDs ............................................................................ 18 EdgePoint PRO Installation Guide ______________________________________________________________________________ AirWalk Proprietary and Confidential Page 4 of 19 1 Introduction 1.1 Proprietary Information Notice THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC. 1.2 Purpose The AirWalk EdgePoint Pro Femto Cells, called eFemto throughout this document, are small, easily installable miniature base stations designed to provide improved and enhanced coverage inside buildings. Typically the eFemto cells are connected to the public Internet and the operator’s network via Cable, DSL, on-premise fiber optic link, or a similar IP backhaul technology. The eFemto cell offers benefits for both the subscribers as well the operators. The subscribers get better voice service coverage and higher data throughput while the operators are able to provide better coverage in spotty coverage areas and are able to off-load traffic from the macro cellular network. In addition, indoor coverage problems may be resolved by using the eFemto cell. 1.3 Scope This document describes the installation procedure for the eFemto cell. The scope of this document covers the description, environmental specifications, equipment location, cabling, and installation followed by trouble shooting steps if required during the installation of the eFemto device. EdgePoint PRO Installation Guide ______________________________________________________________________________ AirWalk Proprietary and Confidential Page 5 of 19 2 Acronyms 1xEVDO 1x Evolution Data Optimized 1xRTT 1x Real Time Transmission AAA Authentication, Authorization and Accounting AN Access Network BSC Base Station Controller BTS Base Station Transceiver Subsystem DHCP Dynamic Host Control Protocol DNS Domain Name Server DSCP Differentiated Services Code Point FCC Federal Communications Commission FSM Femto cell Station Manager FQDN Fully Qualified Domain Name GPS Global Positioning System IKEv2 Internet Key Exchange version 2 IMS IP Multimedia Subsystem IOS Interoperability Specification ISAKMP Internet Security Association and Key Management Protocol…
Text truncated - open the document above for the full version.
Ed P i t PRO Ed ge P o i n t PRO Reference Guide 1/24/2011 Page 1 AirWalk Communications Proprietary and Confidential Table of Contents • What to Expect with EdgePoint PRO • Performance Features • Network Requirements • Contents of the Installation Kit • Steps to Install the Device – Step One – Select Location – Step Two –Mount Bracket to Wall – Step Three – Position Power Supply, Cables and Antennas – Step Four –Secure EdgePoint PRO to Bracket and Connect Cables – Step Five –Powering Up the EdgePoint PRO • Authorized User Lists • Common Troubleshooting Tips • Customer Support • Safety and Regulations 1/24/2011 Page 2 AirWalk Communications Proprietary and Confidential What to Expect with AirWalk EdgePoint PRO The EdgePoint PRO is a compact cellular access point, also known as an enterprise femtocell. It expands 3G cellular service inside buildings so mobile users can experience full voice and data service in areas that have inconsistent or no cellular signal. Typical installations include office buildings, warehouses, high rises, convention centers and other in ‐ building hot spots. The EdgePoint PRO works as an access point independent of the macro network towers to bring cellular capacity and coverage to a specific area. While users are in the designated enterprise femtocell coverage area their cellular signal will be provided by the EdgePoint PRO rather than the macrocell towers. Cellular service is seamless, so users are fully mobile to move between the femtocell coverage area and the ma cro network macrocell towers. Cellular service is seamless, so users are fully mobile to move between the femtocell coverage area and the ma cro network coverage area with no service interruptions. EdgePoint Pro Advantages: • Voice Clarity and Full Mobility: R eliable voice coverage and increased cellular capacity from the EdgePoint PRO frees users from relying solely on a traditional land line. Cellular phones become a practical option to use as a primary phone both inside and outside of a building. • Consistent High ‐ Speed Data: Mobile data users are able to rely upon their mobile phone or laptop with CDMA AirCard to access applications, accounts and other electronic information throughout the coverage area. Cellular service is a reliable and secure technology . • Standard Phone Convenience : The EdgePoint PRO service is compatible with any CDMA cellular phone or AirCard. • Long Term Performance: Once the device is installed, there is typically no reason to move, or update the EdgePoint PRO. This unit is also maintenance free and requires no regular maintenance. 1/24/2011 Page 3 AirWalk Communications Proprietary and Confidential EdgePoint PRO Features Device Performance Device Specifics Device Performance Simultaneously supports up to 28 users for voice and up to 32 users for data services Covers up to 100,000 square feet of indoor space with 200mW of RF power Device Specifics 3G, CDMA technology 1xRTT (voice) and 1xEV ‐ DO Rev. A (data) 15 amps maximum / 120V AC Compatible with any standard ‐ issue CDMA cellular phone Feature transparency with the CDMA macro network Supports 911 emergency calls Dimensions: 12”H x 14.6”W x 2”D Weight : ~ 6.5 lbs (9 lbs with bracket) Temperature: 32 ° F t ‐ 122 ° F Humidity: 0% to 95% non ‐ condensing RJ 45 for connection to standard CAT 5 or CAT 6 Connection 3GPP2 compliant Safety and FCC certified 1/24/2011 Page 4 AirWalk Communications Proprietary and Confidential Network Requirements The EdgePoint PRO is IP ‐ based, it plugs directly into an existing broadband connection to extend 3G wireless service. Minor adjustments to the network settings may be required for a successful implementation. The available LAN network should meet the following requirements for bandwidth and capacity. Service Usage Type Bandwidth Requirements Capacity Description Maximum Capacity 5 Mbps 28 voice calls and 32 active data users, simultaneous Idl 20 Kb N i Idl e 20 Kb ps N o act i ve users Voice Traffic Only 60 Kbps per call Maximum of 28 concurrent calls Data Traffic Only 3 Mbps per device (maximum) Maximum of 32 simultaneous data sessions If multiple devices are installed throughout a campus there will be an increase of IP traffic on the LAN LAN Installation Considerations (varies depending upon the existing customer network) • The device supports standard RJ 45 LAN connection • The device supports IP addressing using DHCP (default) or direct configuration of a static IP address. • The local LAN needs to be adjusted for access to external internet and allow packets to be routed through the customer’s network. WAN Cidti WAN C ons id era ti ons • All packets are marked with a configurable Class of Service that can be used by the Customer Premise router for priority routing. • The following WAN considerations should be addressed prior to installing the device. UDP Port 500 is open on the firewall Internet Security Association is properly configured Key Management Protocol (ISAKMP) is addressed for VPN networks 1/24/2011 Page 5 AirWalk Communications Proprietary and Confidential Key Management Protocol (ISAKMP) is addressed for VPN networks UDP port 4500 is open on the firewall IPSec NAT Traversal is allowed Contents of the Installation Kit EdgePoint PRO Mounting bracket GPS antenna Power converter and 5 ft (1.5 m) cable RF antenna User ’ s Guide Ethernet cable User s Guide Other Documentation 16.4 ft (5m) 2 secure lock bracket EdgePoint PRO User Guide Version 0.1 November 2010 1/24/2011 Page 6 AirWalk Communications Proprietary and Confidential screws Step One – Select Location EdgePoint PRO location requirements: Ethernet Power EdgePoint PRO location requirements: • Flat 24”x24” wall space so a physical clearance of 5” on all sides of the device is observed to ensure efficient operation of the cooling fans and antennas • A building support beam for mounting support (recommended) GPS Antenna Ethernet connection Power connection • Access to a…
Text truncated - open the document above for the full version.
EdgePoint PRO System Labeling DetailsSystem Labeling Details EdgePoint PROEdgePoint PRO MODEL: FCC ID: R4HAWEPPROITEM MASTER: MAC ID: 50.0 mm MAC ID: DC IN: 12 VDC / 8A 0009D200000SERIAL #: E112577 Complies with UL 60950-1 CSA C22.2 No 60950-1 DC IN: 12 VDC / 8A Made In U.S.A. AA00000A 76.0 mm Applies to chassis and external packaging box Chassis Label Location FCC / Safety Info Label p laced on back side of unit MAC ID and Serial # Info on small label that will be able to be read p close to the power switch while unit is installed on wall AA00000A EdgePoint PRO MODEL: FCC ID: R4HAWEPPROITEM MASTER: MAC ID: DC IN: 12 VDCA 0009D200000 Made In U.S.A. SERIAL #: AA00000A MAC ID:0009D200000SERIAL #: 12345678 AA00000A 12345678 WindRiver Licensing labels
@Copyright 2011 AirWalk Communications, Inc., All Rights Reserved EdgePoint PRO Product Description Document Version # 1.0 March 29, 2011 Prepared By AirWalk Communications, Inc. 1830 North Greenville Ave Richardson, TX, 75081 Phone: (972) 638-9400 Fax: (972) 638-9401 www.airwalkcom.com EdgePoint / EdgePoint PRO Product Description Proprietary and Confidential Page 2 of 17 Revision History Version Date Person Description 0.1 3/18/08 MGD Initial Product Description Document 1.0 3/10/2011 J. Kim Update Description Revision Numbering Key 0.x Work in Progress 1.0 Initial Document Approval 1.x Revision Following Initial Document Approval 2.0 Revision Approval EdgePoint / EdgePoint PRO Product Description Proprietary and Confidential Page 3 of 17 Table of Contents TABLE OF CONTENTS ............................................................................................................................. 3 1 INTRODUCTION ................................................................................................................................ 4 1.1 PROPRIETARY INFORMATION NOTICE ............................................................................................. 4 1.2 PURPOSE OF DOCUMENT ................................................................................................................. 4 1.3 SCOPE .............................................................................................................................................. 4 1.4 TERMINOLOGY ................................................................................................................................ 4 1.5 APPLICABLE DOCUMENTS ............................................................................................................... 4 2 EDGEPOINT PRO FEMTO SYSTEM INTRODUCTION ............................................................. 6 2.1 ARCHITECTURE OVERVIEW ............................................................................................................. 6 2.2 EDGEPOINT NETWORK CONFIGURATION ......................................................................................... 7 2.3 EDGEPOINT PRO PACKAGING ....................................................................................................... 11 3 EDGEPOINT PRO HARDWARE .................................................................................................... 13 3.1 EDGEPOINT PRO DIGITAL HARDWARE OVERVIEW ...................................................................... 13 3.2 POWER PC ..................................................................................................................................... 14 3.3 QUALCOMM CHIPSETS ................................................................................................................... 15 3.4 GPS MODULE ................................................................................................................................ 15 3.5 NETWORK LISTEN FUNCTION ........................................................................................................ 16 3.6 EFTR (ENTERPRISE FEMTO TRANSCEIVER) BOARD ..................................................................... 16 3.7 1900 MHZ EFTR .......................................................................................................................... 17 3.8 800 MHZ EFTR ............................................................................................................................ 17 3.9 EDGEPOINT PRO FEU .................................................................................................................. 17 EdgePoint / EdgePoint PRO Product Description Proprietary and Confidential Page 4 of 17 1 INTRODUCTION 1.1 Proprietary Information Notice THIS DOCUMENT IS THE PROPERTY OF AIRWALK COMMUNICATIONS, INC. THE RECIPIENT MAY USE IT ONLY FOR THE PURPOSE FOR WHICH IT WAS TRANSMITTED AND WILL BE RETURNED UPON REQUEST OR WHEN NO LONGER NEEDED BY RECIPIENT. IT MAY NOT BE COPIED OR COMMUNICATED WITHOUT THE WRITTEN CONSENT OF AIRWALK COMMUNICATIONS, INC. 1.2 Purpose of Document This document defines the unique IP and SIP based CDMA EdgePoint PRO Femtocell products developed by AirWalk Communications, Inc. The AirWalk EdgePoint PRO Family of Femto cells are commercially available, standards compliant, optimal channel capacity, cost effective, compact and reliable small footprint wireless radio access network systems that could be deployed in residential and enterprise environments to augment existing macro coverage. The EdgePoint PRO Femto cells can also provide coverage in areas where the service providers hold valid licenses but do not have macro coverage or cell sites. The AirWalk EdgePoint PRO are available as a combination product that supports 1XRTT and 1XEVDO networks simultaneously, also included on the board is a 10 frequency hopping plot beacon, used to attract mobiles to the device. For 1XRTT, the Base Station Transceiver (BTS) and Base Station Controller (BSC) are integrated into a unique single board computer hat can use SIP signaling or IOS to support voice and data call processing. Similarly for 1XEVDO, the RN and RNC are integrated into a single board computer. The combination 1XRTT/1XEVDO/PB product integrates the BTS, RN, BSC and RNC onto a single board computer. 1.3 Scope The scope of this document covers the functional, performance, and environmental specifications of the AirWalk EdgePoint PRO family of Femto cells. 1.4 Terminology See Section 6 -ACRONYMS 1.5 Applicable Documents The following documents are applicable to the extent specified in this Product Description Document. • TIA/EIA/IS-2000 Series Revision: C - Introduction to CDMA2000 Spread Spectrum Systems, 05/00/02 • Personal Station – Base Station Compatibility Requirements for 1.8 to 2.0 GHz CDMA PCS. • TIA/EIA-664 - Wireless Features Description, 12/00/00 • TIA/EIA Interim Standard 95 Revision A - Mobile Station –Base Station Compatibility St…
Text truncated - open the document above for the full version.
AirWalk PNDescriptionMfr PN PSU0011P/S, AC/DC, 110VAC,100W, 12VDC, 8.3A AEF100PS12 CBL0142CABLE, POWER CORD, 18AWG, 3 COND, 6', BLACK 350049-LD01 SUB0101FEU, 1900MHZ, 600MW, 60HZ BW, ENTERPRISE FEMTO STI1900-28HM-EF ENC0007ENCLOSURE, EF, METAL CHASSIS ENC0008COVER, PLASTIC WALLMOUNT, ENTERPRISE FEMTO MEC0094LIGHT PIPE, CLEAR PLASTIC, ENTERPRISE FEMTO HDW0033SCREW, 2-56, SEMS PAN HEAD PHILLIPS, .75L (LIGHT PIPE TO COVER) HDW0022SCREW, M4X8, PAN, PHILIPS, SS PHSM4X8-PH-SS HDW0023SCREW, SOCKET HEAD CAP, M4X30, BLACK OXIDE (FAN HW) SHCM4X30-STl-BO HDW0024SPLIT LOCK WASHER, 4MM, SS (FAN HW) SLWM4-SS HDW0025NUT, 4MM, SS (FAN HW) HXNM4-SS FAN0018FAN ASSEMBLY, 40x40x20, W/TACH OUTPUT AND MOLEX CONNECTOR HA40201V4-0000-C99 FAN0019FAN, FINGER GUARD, 40X40, 4MM SCREW TABS, BLACK FINISH MC34242 HDW0026SPLIT LOCK WASHER, 3MM, SS SLWM3-SS HDW0027SCREW, M3X8, PAN, PHILIPS, SS PHSM3X8-PH-SS MEC0092LOCK BRACKET, ENTERPRISE FEMTO HDW0029SCREW, M3 X 20, PHILIPS, SS, RF AMP PHSM3X20-PH-SS HDW0018SCREW, M2 X 6, PAN, PHILLIPS (MSM TO EF) 90116A010 PBA0027ASSY, PBA, MSM MOBILE MODULE (FOR EF) See separate BOM CBL0145CABLE, MOBILE LISTENER INTERCONNECT H.FL + H.FL 150mm PBA0029ASSY, PBA, ENTERPRISE FEMTO 1X/DO/1900 MHZ XCVR See separate BOM
Cycolac* Resin FR15U Americas: COMMERCIAL Flame retardant ABS with excellent indoor UV properties and excellent processing. UL94 V-0/5VA rated. Elevated UL RTI rating (90-85-90) for all colors except for blue and green colors (60-60-60). TYPICAL PROPERTIES ¹TYPICAL VALUEUNITSTANDARD MECHANICAL Tensile Stress, yld, Type I, 0.2 in/min 5400 psi ASTM D 638 Tensile Stress, brk, Type I, 0.2 in/min 4300 psi ASTM D 638 Tensile Strain, yld, Type I, 0.2 in/min 2.4 % ASTM D 638 Tensile Strain, brk, Type I, 0.2 in/min 17 % ASTM D 638 Tensile Modulus, 0.2 in/min 299000 psi ASTM D 638 Flexural Stress, yld, 0.05 in/min, 2 in span 9700 psi ASTM D 790 Flexural Modulus, 0.05 in/min, 2 in span 339000 psi ASTM D 790 Tensile Stress, yield, 50 mm/min 41 MPa ISO 527 Tensile Strain, break, 50 mm/min 21.9 % ISO 527 Tensile Modulus, 1 mm/min 2210 MPa ISO 527 Flexural Stress, yield, 2 mm/min 63 MPa ISO 178 Flexural Modulus, 2 mm/min 2260 MPa ISO 178 IMPACT Izod Impact, notched, 73°F 4 ft-lb/in ASTM D 256 Instrumented Impact Total Energy, 73°F 251 in-lb ASTM D 3763 Izod Impact, notched 80*10*4 +23°C 12 kJ/m² ISO 180/1A THERMAL Vicat Softening Temp, Rate B/50 201 °F ASTM D 1525 HDT, 66 psi, 0.125", unannealed 187 °F ASTM D 648 HDT, 264 psi, 0.125", unannealed 167 °F ASTM D 648 CTE, flow, -40°F to 100°F 5.E-05 1/°F ASTM E 831 CTE, xflow, -40°F to 100°F 5.1E-05 1/°F ASTM E 831 Vicat Softening Temp, Rate B/50 92 °C ISO 306 Relative Temp Index, Elec 90 °C UL 746B Relative Temp Index, Mech w/impact 85 °C UL 746B Relative Temp Index, Mech w/o impact 90 °C UL 746B PHYSICAL Specific Gravity 1.19 - ASTM D 792 Source, GMD, Last Update:12/08/2005 PLEASE CONTACT YOUR LOCAL SALES OFFICE FOR AVAILABILITY IN YOUR AREA DISCLAIMER : THE MATERIALS AND PRODUCTS OF THE BUSINESSES MAKING UP THE SABIC INNOVATIVE PLASTICS COMPANY, ITS SUBSIDIARIES AND AFFILIATES ("SABIC IP"), ARE SOLD SUBJECT TO SABIC IP' S STANDARD CONDITIONS OF SALE, WHICH ARE INCLUDED IN THE APPLICABLE DISTRIBUTOR OR OTHER SALES AGREEMENT, PRINTED ON THE BACK OF ORDER ACKNOWLEDGMENTS AND INVOICES, AND AVAILABLE UPON REQUEST. ALTHOUGH ANY INFORMATION, RECOMMENDATIONS, OR ADVICE CONTAINED HEREIN IS GIVEN IN GOOD FAITH, SABIC IP MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, (I) THAT THE RESULTS DESCRIBED HEREIN WILL BE OBTAINED UNDER END-USE CONDITIONS, OR (II) AS TO THE EFFECTIVENESS OR SAFETY OF ANY DESIGN INCORPORATING SABIC IP MATERIALS, PRODUCTS, RECOMMENDATIONS OR ADVICE. EXCEPT AS PROVIDED IN SABIC IP' S STANDARD CONDITIONS OF SALE, SABIC IP AND ITS REPRESENTATIVES SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS RESULTING FROM ANY USE OF ITS MATERIALS OR PRODUCTS DESCRIBED HEREIN.Each user bears full responsibility for making its own determination as to the suitability of SABIC IP' s materials, products, recommendations, or advice for its own particular use. Each user must identify and perform all tests and analyses necessary to assure that its finished parts incorporating SABIC IP materials or products will be safe and suitable for use under end-use conditions. Nothing in this or any other document, nor any oral recommendation or advice, shall be deemed to alter, vary, supersede, or waive any provision of SABIC IP' s Standard Conditions of Sale or this Disclaimer, unless any such modification is specifically agreed to in a writing signed by SABIC IP. No statement contained herein concerning a possible or suggested use of any material, product or design is intended, or should be construed, to grant any license under any patent or other intellectual property right of SABIC Innovative Plastics Company or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product or design in the infringement of any patent or other intellectual property right * Cycolac is a trademark of the SABIC Innovative Plastics Company © 1997-2007 SABIC Innovative Plastics Company.All rights reserved 1) Typical values only. Variations within normal tolerances are possible for variose colours.All values are measured at least after 48 hours storage at 230C/50% relative humidity. All properties, expect the melt volume rate are measured on injection moulded samples. All samples are prepared according to ISO 294. 2) Only typical data for material selection purpose.Not to be used for part or tool design. 3) This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions. 4) Own measurement according to UL. Cycolac* Resin FR15U Americas: COMMERCIAL TYPICAL PROPERTIES ¹TYPICAL VALUEUNITSTANDARD PHYSICAL Mold Shrinkage, flow, 0.125" 0.5 - 0.7 % GE Method Melt Flow Rate, 230°C/3.8 kgf 3.3 g/10 min ASTM D 1238 Melt Viscosity, 200°C, 1000 sec-1 3200 poise ASTM D 3825 Density 0.04 lb/in³ ISO 1183 Melt Flow Rate, 220°C/5.0 kg 7 g/10 min ISO 1133 Melt Volume Rate, MVR at 220°C/10.0 kg 40 cm³/10 min ISO 1133 ELECTRICAL Arc Resistance, Tungsten {PLC} 7 PLC Code ASTM D 495 Hot Wire Ignition {PLC) 2 PLC Code UL 746A High Voltage Arc Track Rate {PLC} 4 PLC Code UL 746A High Ampere Arc Ign, surface {PLC} 4 PLC Code UL 746A Comparative Tracking Index (UL) {PLC} 1 PLC Code UL 746A Volume Resistivity >1.E+14 Ohm-cm IEC 60093 Dielectric Strength, in oil, 3.2 mm 20 kV/mm IEC 60243-1 FLAME CHARACTERISTICS UL Recognized, 94V-0 Flame Class Rating (3) 0.059 in UL 94 UL Recognized, 94-5VA Rating (3) 0.11 in UL 94 Source, GMD, Last Update:12/08/2005 PLEASE CONTACT YOUR LOCAL SALES OFFICE FOR AVAILABILITY IN YOUR AREA DISCLAIMER : THE MATERIALS AND PRODUCTS OF THE BUSINESSES MAKING UP THE SABIC INNOVATIVE PLASTICS COMPANY, ITS SUBSIDIARIES AND AFFILIATES ("SABIC IP"), ARE SOLD SUBJECT TO SABIC IP' S STANDARD CONDITIONS OF SALE, WHICH ARE INCLUDED IN THE APPLICABLE DISTRIBUTOR OR OTHER SALES AGREEMENT, PRINTED ON THE BACK OF ORDER ACKNOWLEDGMENTS AND INVOICES, AND AVAILABLE UPON REQUEST. ALTHOUGH ANY INFORMATION, RECOMMENDATIONS, OR ADVICE CONTAINED HEREIN IS GIVEN IN GOOD FAITH, SABIC IP MAKES NO WARRANTY …
Text truncated - open the document above for the full version.
AirWalk PN Item DescriptionManufacturers Name Manufacturers PN CAP0011 CAPACITOR, CERAMIC, 0.1UF, +/-10%, 10V, X7R, 0402PANASONICECJ0EB1A104K CAP0155 CAPACITOR, CERAMIC, 1.0 PF, +/-0.25PF, 50V, C0G, 0402MURATA GJM1555C1H1R0C B01D CAP0015 CAPACITOR, CERAMIC, 1.0UF,-20%/+80%, 6.3V, Y5V, 0402MURATA GRM155R60J105K E19D CAP0137 CAPACITOR, CERAMIC, 1.5 PF, +/-0.25PF, 50V, C0G, 0402MURATA GRM1555C1H1R5 CZ01D CAP0090 CAPACITOR, CERAMIC, 100 PF, +/-5%, 50V, C0G, 0402PANASONICECJ0EC1H101J CAP0095 CAPACITOR, CERAMIC, 1000 PF, +/-10%, 50V, X7R, 0402PANASONICECJ0EB1H102K CAP0007 CAPACITOR, CERAMIC, 10000 PF, +/-10%, 16V, X7R, 0402MURATA GRM155R71C103K A01D CAP0146 CAPACITOR, CERAMIC, 12 PF, +/-5%, 50V, X7R, 0402MURATA GRM1555C1H120J Z01D CAP0148 CAPACITOR, CERAMIC, 2.7PF, +/-0.25PF, 50V, X7R, 0402MURATA GRM1555C1H2R7 CZ01D CAP0117 CAPACITOR, CERAMIC, 22 PF, +/-5%, 50V, C0G, 0402PANASONICECJ0EC1H220J CAP0042 CAPACITOR, CERAMIC, 22 UF, -20%/-80%, 6.3V, Y5V, 0805KEMETC2012Y5V0J226Z CAP0093 CAPACITOR, CERAMIC, 220 PF, +/-5%, 50V, C0G, 0402PANASONICECJ0EC1H221J CAP0088 CAPACITOR, CERAMIC, 33 PF, +/-5%, 50V, C0G, 0402PANASONICECJ0EC1H330J CAP0096 CAPACITOR, CERAMIC, 3300 PF, +/-10%, 25V, X7R, 0402PANASONICECJ0EB1E332K CAP0195 CAPACITOR, CERAMIC, 33000 PF, 16V, +/-10%, X7R, 0402MURATA GRM155R71C333K A01D CAP0158 CAPACITOR, CERAMIC, 39 PF, +/-5%, 50V, C0G, 0402MURATA GRM1555C1H390J Z01D CAP0193 CAPACITOR, CERAMIC, 4700 PF, 25V, +/-10%, X7R, 0402MURATA GRM155R71E472K A01D CAP0194 CAPACITOR, CERAMIC, 82 PF, 50V, +/-5%, C0G, 0402MURATA GRM1555C1H820J Z01D CAP0196 CAPACITOR, CERAMIC, 82000 PF, 16V, +/-10%, X7R, 0402MURATA GRM155R71C823K A88D CAP0192 CAPACITOR, TANTALUM, 10 UF, 6.3V, +/-20%, 0603Vishay/Sprague 298D106X06R3M2 T CAP0190 CAPACITOR, TANTALUM, 2.2 UF, 16V, +/-20%, 0603Vishay/Sprague298D225X0016M2T CAP0191 CAPACITOR, TANTALUM, 4.7 UF, 10V, +/-20%, 0603Vishay/Sprague298D475X0010M2T CON0091CONNECTOR, B2B, HEADER PANASONIC ELECTRIC WORKSAXK826145WG CON0072CONNECTOR, JACK, RF, H.FL SERIES, SMDHIROSEH.FL-R-SMT(01) MDM0005 IC, QSC6085, CDMA, BASE BAND MODEMQUALCOMMQSC6085 IND0115INDUCTOR, CHIP, 1.2NH, +/-0.3NH, 300MA, 0402MURATALQG15HN1N2S02D IND0116INDUCTOR, CHIP, 1.5NH, +/-0.3NH, 300MA, 0402MURATALQG15HN1N5S02D IND0144INDUCTOR, CHIP, 12NH, +/- 5%, 0402PANASONICELJQF12NJF IND0123 INDUCTOR, CHIP, 3.3NH, +/-0.3NH, 300MA, 0402, HFMURATALQG15HS3N3S02D IND0153INDUCTOR, CHIP, 33NH, +/-5%, 250MA, HF, 0402TAIYO-YUDENHK100533NJ-T IND0129INDUCTOR, CHIP, 39 NH, +/-5%, 200MA, 0402MURAT ALQG15HN39NJ02D IND0127INDUCTOR, CHIP, 4.7 NH, +/-0.3NH, 300MA, 0402MURATALQG15HS4N7S02D IND0103INDUCTOR, CHIP, 47NH, +/-5%, 210MA, 0402MURATALQW15AN47NJ00D IND0135 INDUCTOR, CHIP, 5.6NH, +/-0.2NH, 800MA, 0402, THIN FILMMURATA LQW15AN5N6C10 D IND0133 INDUCTOR, CHIP, 8.2NH, +/-0.2NH, 540MA, 0402, THIN FILMMURATA LQW15AN8N2G00 D IND0154 INDUCTOR, POWER, 2.2UH, 0.9A, +/-20%, 2.8X2.8, SMDABCOLPF3015-2R2M-C IND0155INDUCTOR, POWER, 4.7 NH, 0.7A, +/-20%, 2.8X2.8 ABCOLPF3010T-4R7N MEM0043 MEMORY, MCP, 1GB NAND FLASH X 256MB DDR SDRAM, 107 BGA SAMSUNG ELECTRONICSK521F57ACA-B060 OSC0024OSC, TUNING FORK, 32.768 KHZ, 12.5PF, SMDCITIZEN CM315- 32.768KDZF-UT OSC0025 OSC, VOLTAGE CONTROLLED, 19.2MHZ, 3.3V, 32X25NDK NT3225SA- 19.200000MHZ-T2 PCB0038PCB, MSM MOBILE MODULE (FOR EF) REG0049 REGULATOR, DC/DC BUCK, SYNCHRONOUS, 0.6- 5.5VDC, 1.25A, 6DFN LINEAR TECHNOLOGY LTC3564EDCB#TR MPBF RES0073RESISTOR, CHIP, 0.0 OHM, 1/16W, +/-5%, 0402ROHMMCR01MZPJ000 RES0186RESISTOR, CHIP, 1 M OHM, 1/10W, +/-1%, 0402PANASONICERJ2RKF1004X RES0128RESISTOR, CHIP, 1.0 K OHM, 1/16W, +/-1%, 0402ROHMMCR01MZPF1001 RES0075RESISTOR, CHIP, 10 OHM, 1/16W, +/-5%, 0402ROHMMCR01MZPJ100 RES0092RESISTOR, CHIP, 10.0 K OHM, 1/16W, +/-5%, 0402 ROHMMCR01MZPJ103 RES0082RESISTOR, CHIP, 100 OHM, 1/16W, +/-5%, 0402ROHMMCR01MZPJ101 RES0122RESISTOR, CHIP, 12.0 K OHM, 1/16W, +/-5%, 0402 ROHMMCR01MZPJ123 RES0185RESISTOR, CHIP, 121 K OHM, 1/16W, +/-1%, 0402 VISHAY CRCW0402121KFK ED RES0105RESISTOR, CHIP, 2.0 K OHM, 1/16W, +/-5%, 0402ROHMMCR01MZP…
Text truncated - open the document above for the full version.
1830 North Greenviile · Richardson · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.93 GHz - 1.99 GHz | 1.06 W | 3M95F9W | 2.5000000000 ppm |

XCVB 800MHZ
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
CDMA-2000 IP-Base Station
Equipment Class
PCB - PCS Licensed Transmitter