Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 11, 2015
Application Purpose
Original Equipment
Date of Application
Jan 11, 2015
Equipment Note
Lively Watch
Frequency Range
2402.00000000 - 2480.00000000
Company
GreatCall Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Warranty Information www.mylively.com © 2014 Lively. All rights reserved. Lively and LivelyGram are a trademark of Lively, Inc. BACK COVERFRONT COVER Información de Garantía Lively Limited Warranty 1 Lively warrants to the original purchaser that its sensor and hub hardware (excluding batteries, the “Equipment”) will be free of any defect in material and workmanship according to the terms and conditions of this Limited Warranty (“Limited Warranty”). For purposes of this Limited Warranty, the original purchaser is deemed to be the original end user of the Equipment purchased. This Limited Warranty is valid only for the original purchaser and is NONTRANSFERABLE and UNASSIGNABLE. For How Long: This Limited Warranty covers the Equipment for twelve (12) months from the date of the original shipment to the original purchaser for Equipment. Batteries are not covered by this Limited Warranty. The terms of the Limited Warranty in effect as of the date of original purchase will apply to any warranty claims. How to Initiate Warranty Service: To obtain warranty service for your Equipment, call toll free (888) 757-0711 or email [email protected]. We will try to resolve your issue over phone and/or email and determine warranty coverage. If necessary, and at our sole discretion, we will arrange for service or a replacement of some or all of the Equipment. What We Will Do: Lively at its sole discretion will repair or replace the Equipment, provided the warranty applies and the warranty period has not expired. The repaired or replaced Equipment will be warranted subject to the terms and conditions of this Limited Warranty for either (a) 90 days or ( b) the remainder of the original warranty period, whichever is longer. THE SERVICE DESCRIBED IN THIS LIMITED WARRANTY IS LIVELY’S SOLE AND EXCLUSIVE OBLIGATION, AND YOUR SOLE AND EXCLUSIVE REMEDY, FOR ANY BREACH OF WARRANTY. Obligations and Warranty Limits: Limited Warranty Obligation: Exclusive Remedy THE FOREGOING LIMITED WARRANTY IS IN LIEU OF AND SPECIFICALLY EXCLUDES AND REPLACES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. English p. 1 EN Español p. 5 ES INSIDE FRONT COVER 32 This Limited Warranty is Void if: 1. Any Lively Equipment is tampered with, modified, serviced or repaired by any person or entity other than Lively, unless specifically authorized in writing by Lively. 2. Any Lively Equipment case is opened by unauthorized personnel or if Equipment is used for an unauthorized purpose or contrary to the proper use as described in writing by Lively. 3. Any Lively Equipment is used in conjunction with incompatible products, parts or accessories, including but not limited to batteries. Products, parts and accessories are not compatible if they are not Lively products or products that Lively has expressly authorized for use with the Equipment. If the Warranty Period has Expired: If your Lively Equipment is not covered by our Limited Warranty, call toll free (888) 757-0711 or email [email protected] for advice as to whether we can repair your Equipment, and for other repair information, including charges. Charges for non-warranty repairs that you authorize will be billed to your account. Upon completion of the repair, the terms and conditions of this Limited Warranty shall apply to such repair or replacement Equipment for a period of 90 days. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. This device complies with Part 15 of the FCC rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en com- promettre le fonctionnement. Some jurisdictions do not allow limitations on how long an implied warranty lasts, or other warranty limitations, so some or all of the limitations herein may not apply to you. NO PERSON (INCLUDING ANY AGENT, DEALER OR REPRESENTATIVE OF LIVELY) IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTY CONCERNING LIVELY EQUIPMENT, EXCEPT TO REFER PURCHASERS TO THIS LIMITED WARRANTY. YOUR EXCLUSIVE REMEDY WITH RESPECT TO ANY AND ALL LOSSES OR DAMAGES ARISING IN CONNECTION WITH THE EQUIPMENT FROM ANY CAUSE WHATSOEVER SHALL BE AS SPECIFIED ABOVE. LIVELY SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, PUNITIVE, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, EXEMPLARY DAMAGES, COMMERCIAL LOSS FROM ANY CAUSE, BUSINESS INTERRUPTION OF ANY NATURE, LOSS OF PROFITS OR PERSONAL INJURY OR DEATH, EVEN IF LIVELY HAS BEEN ADVISED OF THE POSSIBILITIES OF SUCH DAMAGES, HOWEVER OCCASIONED, WHETHER BY NEGLIGENCE OR OTHERWISE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. What this Warranty Does Not Cover: This Limited Warranty covers only the types of defects described above. It does not cover any other types of defects or damages, such as those resulting from ( but not limited to) accidents, contact with liquids, damage while in transit to or from our service location, product tampering, unauthorized alterations, unauthorized service, use of the Equipment in ways not authorized in our product documentation, unauthorized Equipme…

Text truncated - open the document above for the full version.

Users Manual

www.mylively.com © 2014 Lively. All rights reserved. Lively and LivelyGram are a trademark of Lively, Inc. Lively Safety Watch User Guide Guía de usuario para el reloj de seguridad Lively p. 2 Safety watch overview p. 4 Installing the battery p. 5 Activating the watch p. 6 Pushing the help button p. 8 Receiving medication reminders p. 10 Having fun with step-counting p. 11 Using the safety watch with a smartphone p. 12 Customizing your safety watch p. 13 Using Lively’s custom watch band CONTENTS (english language) Para obtener instrucciones en español, consulte la página 14. IMPORTANT You must activate your Lively system, at app.mylively.com/start, in order to set up the safety watch. During the activation process, you will receive a test emergency phone call. Once activated, your safety watch must maintain a constant connection to the Lively hub at home, or be paired on-the-go with a smartphone, for emergency-response use. Welcome to emergency response, reimagined. Lively is much more than a traditional emergency response “button.” Of course, Lively is there when you need to summon help at the push of the button. But we wanted your safety watch to be useful— and fun—for all aspects of your active lifestyle. We started with a fashionable watch that you can customize and accessorize to fit your personality. With smart medication reminders, the safety watch notifies you only when you might have missed taking medication or vitamins. And the watch includes a pedometer for simple step-counting to help you measure how active you are being throughout the day. Enjoy and stay Lively. 2 Lively Safety Watch 3 • Help button Press to receive a call from the Lively Care Team to the phone number you designate. • Water proof You can use the Lively safety watch in the bath and shower. • Day & night display A large, crisp display with back lighting for easy viewing. Tip: Tap the edge of the watch face to light up the display. • Interchangeable bands Your Lively safety watch comes with an easy-to-use, comfortable band, which can also be replaced with any standard watch band (20mm width). User Guide Tip: After a new battery has been installed, the safety watch will re-activate once it is within range of the Lively hub. 4 Installing the battery • Remove the Lively safety watch and battery from its packaging. • Insert the coin battery (standard Li-Ion battery, CR-2032) into the watch. • Using a coin, twist the back cover firmly to close it. This is important to ensure waterproofing. Lively Safety Watch 5 Activating the watch • Make sure the safety watch is near the Lively hub for activation. • Make sure you have completed the online Lively activation process up to the “Activate system” step. • Follow the on-screen instructions to activate the watch. During this process, you will perform a test of the help button and receive a phone call from the Lively Care Team. If you do not currently have online access via a computer or tablet, please call the Lively Care Team at 888-757-0711. • After you have completed activation and successfully received a test phone call, your watch will be ready for use! User Guide Note: The Lively safety watch will not function until you complete the activation process. Tip: At a minimum, we recommend testing your help button when you replace the battery. Just press the button to test the response of Lively’s Care Team. Once you receive a confirmation phone call in response, let Lively know you’re ok and there’s no need for assistance. 6 Pushing the help button Lively Safety Watch • Your safety watch must be connected to the Lively hub or paired on-the-go with your smartphone for emergency response use. See page 12 to pair with a smartphone. • If you need assistance, press the help button. • The Lively Care Team will call you at the phone number you provided during the initial setup of Lively. You can update this phone number by visiting app.mylively.com from a computer or tablet. Tip: The watch’s range of use in the home or the yard is up to 1,500 ft., when unobstructed. Important: Lively is not a substitute for 9-1-1. In the event of a critical emergency, always contact 9-1-1 immediately. By subscribing to the Lively service, you accept, without limitation or qualification, the Lively Terms and Conditions. 7 User Guide • The watch will display the following while the phone call is being placed to you. >> • If you do not answer the telephone, or if you request emergency services while talking to a Lively Care Team member, emergency services will be dispatched. Note: Emergency services will be dispatched to the address you provided during the initial setup of Lively. To update your home address, visit app.mylively.com • The watch will display the following while help is on the way. >> 8 Receiving medication reminders • With Lively’s safety watch and pillbox activity sensors, you will be reminded automatically whenever you’ve missed taking your medication. • Set up medication notifications during the activation process, or go to app.mylively.com and choose Settings > Set Notifications. Simply choose when you want to take medication, and start receiving notifications. • If the pillbox sensors do not detect movement during the window of time when the medicine should be taken, our Lively system automatically sends a helpful reminder to the watch. >> Lively Safety Watch • The medication reminder will repeat once after fifteen minutes, unless the pillbox sensor has registered movement, indicating the medication has been taken. • If medication does not register as taken by the end of the allotted time, notifications will be sent to the Circle members who have been set up to receive them. User Guide 9 10 Having fun with step-counting Lively Safety Watch • Your Lively safety watch also includes a pedometer to keep track of your steps, wherever you are, throughout the day. • Activity is sent to the Lively hub approximately every 15 minutes, when you are in the home, and when you return from bei…

Text truncated - open the document above for the full version.

Cover Letter(s)

Lively, Inc. 683 Schofield Avenue • San Francisco, CA 94129 • Phone: 415-786-6844 E-Mail: [email protected] • www.mylively.com October 31, 2014 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that Lively Inc. authorizes Jean Oliveri to act on our behalf, until otherwise notified, for regulatory applications and related documents submitted to American Certification Body, Inc. (ACB). Sincerely, David Glickman COO and Co-Founder Lively Inc.

Cover Letter(s)

Lively, Inc. 683 Schofield Avenue • San Francisco, CA 94129 • Phone: 415-786-6844 E-Mail: [email protected] • www.mylively.com December 15, 2014 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 Attn: Director of Certification Authority to Act as Agent IC ID: 11045A-0004 I appoint Washington Laboratories, Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by ACB, Inc., still resides with Lively, Inc., 683 Schofield Road, San Francisco, CA 94129. Agency Agreement Expiration Date: December 15, 2015 Sincerely, Jean Olivieri VP, Operations Lively Inc. 408-823-3744

Cover Letter(s)

Lively, Inc. 683 Schofield Avenue • San Francisco, CA 94129 • Phone: 415-786-6844 E-Mail: [email protected] • www.mylively.com October 31, 2014 Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 Subject: Permanent Confidentiality Request for FCC ID: R6N-0004 To Whom It May Concern: Pursuant to Paragraphs §0.457, §0.459 and §0.475(d) of the Commission's Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Hamlet Inc. requests permanent confidentiality for the following products: FCC ID Number Product Name Model R6N-0004 Lively Watch W1000 We request that the following information be held permanently confidential: 1) Electrical Schematics 2) Operational Description / Block Diagram The above exhibits contain Lively Inc.’s trade secrets and proprietary information. The public disclosure of this information could harm Hamlet Inc. and be of benefit to our competitors by revealing trade secret and proprietary information about the design of our product. This material is not customarily available to the general public and we request that it be withheld from public inspection. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Jean Olivieri VP, Operations Lively Inc. 408-823-3744

Cover Letter(s)

Lively, Inc. 683 Schofield Avenue • San Francisco, CA 94129 • Phone: 415-786-6844 E-Mail: [email protected] • www.mylively.com January 12, 2015 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that Lively Inc. confirms that in the next printing of its user material the following warning statement will be included in both English and French: IMPORTANT NOTE: For non- body worn equipment, the antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. This equipment must comply with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Thank you for your attention to this matter. Sincerely, Jean Olivieri VP, Operations Lively Inc. 408-823-3744

External Photos

1 | Page WLL 13665 Test Setup Photos Lively, Inc. Front View Rear View 2 | Page WLL 13665 Side View

Internal Photos

Internal Photographs FCC ID: R6N-0004 Description: Safety Watch Model Name: Lively Watch Model Number: W1000 Lively Inc. 683 Schofield Road San Francisco, CA 94129 By TEM Consulting, LP 140 River Rd. Georgetown, TX 78628 October 2014 The following are internal photographs of the Lively Watch show ing:  PWB front  PWB back  Closeup of the processor, radio chip and power amplifier secti on of the PWB Figure 1 - Lively Watch - Front of the PWB Figure 2 - Lively Watch - Back of the PWB Figure 3 - Lively Watch - Radio Section of the PWB

RF Exposure Info

WLL Report #13665-02 Rev 0 - Page i- © 2015 Washington Laboratories, Ltd. August 22, 2014 Lively Inc. 682 Schofield Road San Francisco, Ca, 94129 Model: Lively Watch FCC ID: R6N-0004 IC ID: 11045A-0004 Washington Laboratories, Ltd. performed a SAR Evaluation on the on the Lively Watch radio device. This product is a wrist worn portable transmitter using Bluetooth LE Technology, operating between 2402MHz and 2480MHz. It is designed to be worn by the user with a separation distance ≤ 5mm and therefore SAR must be considered. The EUT was tested under FCC Part 15.247 as a DTS device. The device has 2 modes of operation a normal 6.82dBm (conducted) data mode and a distress 16.6dBm (conducted) mode. The antenna gain is stated as 3.93dBi. Documentation of the measurement technique used and test data measured can be found in Washington Laboratory Report 13665-01. Refering to the FCC Documument, 447498 D01 General RF Exposure Guidance v05r02, Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies, section 4.3.1 allows for the exclusion of SAR Testing if the device meets the following requirements: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR Where:  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  When the minimum test separation distance is < 5 mm, a distance of 5 mm is used For this device extremity SAR exclusion is being evaluated. WLL Report #13665-02 Rev 0 - Page ii- © 2015 Washington Laboratories, Ltd. 1.1 Normal Operation For Normal Operation (6.82dBm) mode calculation is based on peak continuous power. The conducted power is 6.82dBm (4.8mW) plus an antenna gain of 3.93dBi for an EIRP of 12mW. Using the SAR exclusion calculation: (12mW ÷ 5) * √2.402 ) = 3.72 ≤ 7.5 (12mW ÷ 5) * √2.440 ) = 3.75 ≤ 7.5 (12mW÷ 5) * √2.480 ) = 3.78 ≤ 7.5 The Extremity SAR exclusion applies to the Normal Operation Mode of this device. 1.2 Emergency Mode Description of Emergency Mode Operation: If the wearer has an emergency and depresses the alarm button it transmits at a maximum transmit power of 16.60 dBm. The alarm is transmitted for 7 minute period, sending 1 transmission sequence every 2 seconds. The alarm transmission sequence is a 0.480 msec (480 μsec) transmission, which is sent once on each of the systems three frequency channels. The three 0.480msec transmissions are spaced 1.2 msec apart (measured not between but from the start to start). The 2 second interval is measured from the start of one transmission sequence to the start of the next transmission sequence. Hence, in each 2 second period during the 7 minute alarm period the transmitter is active 3 * 0.48 msec = 1.44 msec. For Emergency Operation (16.6dBm) mode calculation is based on using a duty factor as per section 6.3. “Low transmission duty factor devices” of FCC Documument, 447498 D01 General RF Exposure Guidance v05r02 . The conducted power is 16.6dBm (45.7mW) plus an antenna gain of 3.93dBi for an EIRP of 113mW. The on time is 1.44ms per 2 seconds for a worse case duty factor of 0.072%. This duty cycle give a corrected power of 0.08mw. Using the SAR exclusion calculation: (0.08mW ÷ 5) * √2.402 ) = 0.03 ≤ 7.5 (0.08mW ÷ 5) * √2.440 ) = 0.03 ≤ 7.5 (0.08mW÷ 5) * √2.480 ) = 0.03 ≤ 7.5 The Extremity SAR exclusion applies to the Normal Operation Mode of this device. Therefore, the EUT does not require SAR Testing. WLL Report #13665-02 Rev 0 - Page iii- © 2015 Washington Laboratories, Ltd. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. Washington Laboratories, Ltd. has been accepted by the FCC and approved by ACLASS under Certificate AT-1448 as an independent FCC test laboratory. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by the ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1448. Should you have any questions, please do not hesitate to contact us. Sincerely, James Ritter Steven Dovell EMC Compliance Engineer Compliance Engineer

Test Report

FCC & Industry Canada Certification Test Report For the Lively Inc. Lively Watch FCC ID: R6N-0004 IC ID: 11045A-0004 WLL JOB# 13665-01 Rev 1 December 29, 2014 Prepared for: L IVELY INC. 683 SCHOFIELD ROAD S AN FRANCISCO, CA 94129 Prepared By: Washington Laboratories, Ltd. 7560 Lindbergh Drive Gaithersburg, Maryland 20879 Testing Certificate AT-1448 Certificates and reports shall not be reproduced except in full, without the written permission of Washington Laboratories, Limited. Lively Lively Watch FCC Certification Test Report December 2014 FCC & Industry Canada Certification Test Report for the Lively Inc. Lively Watch FCC ID: R6N-0004 IC ID: 11045A-0004 WLL JOB# 13665-01 Rev 1 January 9, 2014 Prepared by: ___________________________ John P. Repella EMC Compliance Engineer Reviewed by: ____________________________ Steven D. Koster Vice President WLL Report #13655-01 Rev 1 - ii - © 2015 Washington Laboratories, Ltd. Lively Lively Watch FCC Certification Test Report December 2014 Abstract This report has been prepared on behalf of Lively Inc. to support the attached Application for Equipment Authorization. The test report and application are submitted for a Digital Transmission System (DTS) Transmitter under Part 15.247 (10/2013) of the FCC Rules and Regulations and Spectrum Management and Telecommunications Policy RSS-210 issue 8 of Industry Canada. This Certification Test Report documents the test configuration and test results for the Lively Inc. Watch. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. The Industry Canada OATS numbers are 3035A-1 and 3035A-2 for Washington Laboratories, Ltd. Site 1 and Site 2, respectively. Washington Laboratories, Ltd. has been accepted by the FCC and approved by ACLASS under Certificate AT-1448 as an independent FCC test laboratory. The Lively Inc. Lively Watch complies with the limits for a Digital Transmission System (DTS) Transmitter device under FCC Part 15.247 and Industry Canada RSS-210. Revision History Description of Change Date Rev 0 Initial Release December 29, 2014 Rev 1 Addition of Low power (Normal) mode January 9, 2015 WLL Report #13655-01 Rev 1 - iii - © 2015 Washington Laboratories, Ltd. Lively Lively Watch FCC Certification Test Report December 2014 Table of Contents Abstract ........................................................................................................................................... ii 1 Introduction ..............................................................................................................1 1.1 Compliance Statement .................................................................................................... 1 1.2 Test Scope ....................................................................................................................... 1 1.3 Contract Information ....................................................................................................... 1 1.4 Test Dates........................................................................................................................ 1 1.5 Test and Support Personnel ............................................................................................ 1 2 Equipment Under Test .............................................................................................3 2.1 EUT Identification & Description .................................................................................. 3 2.2 Test Configuration .......................................................................................................... 3 2.3 Testing Algorithm ........................................................................................................... 4 2.4 Test Location .................................................................................................................. 4 2.5 Measurements ................................................................................................................. 4 2.5.1 References ................................................................................................................... 4 2.6 Measurement Uncertainty ............................................................................................... 4 3 Test Equipment ........................................................................................................6 4 Test Summary ..........................................................................................................7 5 Test Results ..............................................................................................................8 5.1 Occupied (DTS) Bandwidth: .......................................................................................... 8 5.1.1 Measurement Method: ................................................................................................ 8 5.2 RF Power Output: ......................................................................................................... 15 5.2.1 Measurement Method: .............................................................................................. 15 5.3 Power Spectral Density ................................................................................................. 22 5.3.1 Measurement Method: .............................................................................................. 22 5.4 Conducted Spurious Emissions at Antenna Terminals ................................................. 29 5.4.1 Band Edge Compliance ............................................................................................. 78 5.5 Radiated Spurious Emissions:....................................................................................... 82 5.5.1 Test Procedure ..........................…

Text truncated - open the document above for the full version.

Test Setup Photos

1 | P a g e WLL 13665 Test Setup Photos Lively Inc. 2 | P a g e WLL 13665

Contact Information

Applicant

Dean Williams(Vice President, Technology)
[email protected]8587648065Fax: 8587207399

Technical Contact

Washington Laboratories, Ltd.Steven Koster
[email protected]3012161500

7560 Lindbergh Drive · Gaithersburg, Maryland · United States

Test Firm

Washington Laboratories, Ltd.Steve Koster
[email protected]301-216-1500Fax: 301-216-1590

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz45.71 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. This filing meets the SAR threshold exclusion set forth in KDB447498 and therefore can be used in mobile/portable configurations.

Other Applications from GreatCall Inc.

Home Wellness Sensor - FCC ID R6N-0002 - GreatCall Inc.
R6N-0002

Home Wellness Sensor

Jun 17, 2013

Equipment Class

DTS - Digital Transmission System