Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Sunitec Enterprise Co., Ltd. 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County 23581, Ta i w a n FCC Confidentiality Request Number: CF303 Version: V01 Date: 2012-4-18 To the FCC and FCC TCB handling this application for certification Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company name Sunitec Enterprise Co., Ltd. Addresss 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County23581, Taiwan City Jhonghe Country Ta i w a n request non-disclosure and confidential treatment for our certification under: Grantee Code Product Number FCC ID: RA8 - BH006 of the following materials submitted within this certification application: (please cross what is applicable, or add other documents) Operational Description Block Diagrams Schematics Diagrams Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) Jhonghe,Ta i w a n PFB 27, 2014 Tom Chien General Manager
Sunitec Enterprise Co., Ltd. 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County 23581, Ta i w a n FCC Authorization Letter Number: CF304 Version: V01 Date: 2012-4-18 We, (the approval holder) Company name Sunitec Enterprise Co., Ltd. Addresss 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County23581, Taiwan City Jhonghe Country Ta i w a n declare that the following representative (agent): Name (person) Ruby Zhang Function Supervisor Company name Compliance Certification Services (Shenzhen) Inc. Addresss No10-1, Mingkeda Logistics Park, No.18 Huanguan South RD. Guan lan Town, Baoan District, Shenzhen China City Shenzhen Country China is hereby authorized to apply the following equipment for certification on our behalf: Product Description Bluetooth Alcohol Breath Tester Type or Model(s) BABT-01 Tradename or Brand(s) N/A We also authorize Teleconformity, Mr. M. Koop, (address: Rietven 31, 7534NH Enschede, Netherlands) to process this application. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) Jhonghe,Ta i w a n PFB 27, 2014 Tom Chien General Manager s
Report No: C140218Z02-RP1 Page 1 / 1 External Photos of EUT
Report No: C140218Z02-RP1 Page 1 / 4 Internal Photos of EUT Report No: C140218Z02-RP1 Page 2 / 4 Report No: C140218Z02-RP1 Page 3 / 4 Report No: C140218Z02-RP1 Page 4 / 4
BABT-01SystemDescription TheBluetoothAlcoholBreathTesterisuseCSR1010solution,the CSR1010withBluetoothlowenergysolutionforapplicationspreviously limitedbythepowerconsumption.Thetesterconsistsofthe CSR1010,StatusindicatingLEDandaButtonsforpoweron/off,Pairing. 1.U1(CSR1010)isaClass2Bluetoothsub-systemusingCSR1010chipset fromleadingBluetoothchipsetsupplierCambridgeSiliconRadio. 2.U1componentinsidecreate2.402-2.480GHzcarrierwave. 3.BLEUandREDareLEDtoindicatethetesterworkingmode 4.S1ishumancontrolinterface,Itcontrolthetesterdifferenceoperation
FCC RF Exposure FCC ID: RA8-BH006 Frequency: 2402-2480 MHz (40 Ch) Modulation: FHSS (GFSK) Mid-Channel or highest-measured Peak Power, Conducted: 3.53 dBm == 2.25 mW Antenna Gain: G = 0 dBi Peak, Radiated = 3.53 dBm + 0 dBi = 3.53 dBm = 2.25 mW SAR Test Exclusion Thresholds specified in KDB447498 Appendix A: Evaluation: The Calculated Radiated Peak output power is taken as worst case, and this emission level appears to be under the maximum allowed emission level at even the closest distance for 2.4G device specified in this table. Conclusion: The emitted power appears to be (far) below the required limit, so PASS.
Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 1 / 41 FCC 47 CFR PART 15 SUBPART C for Bluetooth Alcohol Breath Tester Model: BABT-01 Brand: N/A Test Report Number: C140218Z02-RP1 Issued for Sunitec Enterprise Co., Ltd 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County 23581, Taiwan Issued by: Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by TAF, A2LA, NVLAP, NIST or any government agencies. The test results in the report only apply to the tested sample. Compliance Certification Services (Shenzhen) Inc. No.10-1, Mingkeda Logistics Park, No.18 Huanguan South Rd., Guan Lan Town, Baoan District, Shenzhen, China TEL: 86-755-28055000 FAX: 86-755-28055221 Issued Date: January 4, 2014 检 测 CNAS L4818 Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 2 / 41 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. Revision History Rev. Issue No. Revisions Effect Page Revised By 00 C140218Z02-RP1 Initial Issue ALL Sabrina Wang Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 3 / 41 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. TABLE OF CONTENTS 1 TEST CERTIFICATION.............................................................................................. 4 2 TEST RESULT SUMMARY........................................................................................ 5 3 EUT DESCRIPTION ................................................................................................... 6 4 TEST METHODOLOGY ............................................................................................. 7 4.1. DESCRIPTION OF TEST MODES ...................................................................................... 7 5 SETUP OF EQUIPMENT UNDER TEST.................................................................... 8 5.1. DESCRIPTION OF SUPPORT UNITS................................................................................. 8 5.2. CONFIGURATION OF SYSTEM UNDER TEST ................................................................. 8 6 FACILITIES AND ACCREDITATIONS ...................................................................... 9 6.1. FACILITIES .......................................................................................................................... 9 6.2. ACCREDITATIONS ............................................................................................................. 9 6.3. MEASUREMENT UNCERTAINTY....................................................................................... 9 7 FCC PART 15.247 REQUIREMENTS...................................................................... 10 7.1. POWER LINE CONDUCTED EMISSIONS MEASUREMENT........................................... 10 7.2. SPURIOUS EMISSIONS MEASUREMENT....................................................................... 14 7.3. 6dB BANDWIDTH MEASUREMENT ................................................................................. 27 7.4. PEAK OUTPUT POWER ................................................................................................... 30 7.5. BAND EDGES MEASUREMENT....................................................................................... 32 7.6. PEAK POWER SPECTRAL DENSITY MEASUREMENT.................................................. 38 Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 4 / 41 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. 1 TEST CERTIFICATION Product Bluetooth Alcohol Breath Tester Model BABT-01 Brand N/A Tested February 18~March 7, 2014 Applicant Sunitec Enterprise Co., Ltd 10F.-1, No.200, Jingping Rd., Jhonghe City, Taipei County 23581, Taiwan Manufacturer Sunitec Enterprise Co., Ltd No.2, Qilin Road 2, RunTang Ind, Dan-Keng Village Fu Min Community, Guan-Lan Town, BaoAn District, Shenzhen Guangdong China APPLICABLE STANDARDS Standard Test Type Standard Test Type 15.207(a) Power Line Conducted Emissions 15.247(d) 15.209(a) z Spurious Emissions z Conducted Measurement z Radiated Emissions 15.247(a)(2) 6dB Bandwidth Measurement 15.247(b)(3) 15.247(b)(4) Peak Power Measurement 15.247(d) Band Edges Measurement 15.247(e) Peak Power Spectral Density We hereby certify that: The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4: 2009 and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules Part 15.207, 15.209, 15.247. The test results of this report relate only to the tested sample EUT identified in this report. Approved by: Reviewed by: Sunday Hu Supervisor of EMC Dept. Compliance Certification Service Inc. Ruby Zhang Supervisor of Report Dept. Compliance Certification Service Inc. Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 5 / 41 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services. 2 TEST RESULT SUMMARY APPLICABLE STANDARDS Standard Test Type ResultRemark 15.247(a)(2) 6dB Bandwidth Measurement Pass Meet the requirement of limit. 15.247(b)(3) 15.247(b)(4) Peak Power Measurement Pass Meet the requirement of limit. 15.247(d) Band Edges Measurement Pass Meet the requirement of limit. 15.247(e) Peak Power Spectral Density Pass Meet the requirement of limit. 15.247(d) 15.209(a) z Spurious Emissions z Conducted Measurement z Radiated Emissions Pass Meet the requirement of limit. 15.207(a) Power line Conducted Emissions Pass Mee…
Text truncated - open the document above for the full version.
Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 1/2 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: C140218Z02-RP1 FCC ID: RA8-BH006 Page 2/2 RADIATED EMISSION TEST Below 1GHz Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.30 mW |

Bluetooth Audio Transmitter
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BLUETOOTH STEREO SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker
Equipment Class
DTS - Digital Transmission System
Bluetooth Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Stereo Headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter