RAL-0403LOW FREQUENCY RFID TRANSCEIVER

EDiT iD Ltd
LOW FREQUENCY RFID TRANSCEIVER - FCC ID RAL-0403 - EDiT iD Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 18, 2006
Application Purpose
Original Equipment
Date of Application
Sep 17, 2006
Equipment Note
LOW FREQUENCY RFID TRANSCEIVER
Frequency Range
0.12500000 - 0.13420000
Company
EDiT iD Ltd
Country
New Zealand

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Start Guide 1. Setup 3. Charging Front View Rear View Top View Bottom View Power Directional Arrows Backlight Center Menu HomeCalculator Find MZIO™ Module Infrared Port Battery Pack Battery Clip Stylus Communications and Charging Connector Module Fasteners Meazura™ Setup When powering up your Meazura™ for the first time, press the Power button and follow the on-screen instructions to setup the device. This includes calibration of the touch sensitive screen and setting your location, date and time. During this procedure, you can at your option take a Graffiti writing tutorial for entering text and special characters on your Meazura™. Touch sensitive screen Graffiti Pad • Plug the Communications cable into a USB or Serial port on your computer (as pictured in figure 2a/b below). • Connect the communications cable to the communication connector located at the bottom of the Meazura™ (as pictured in figure 1 left). • Ensure the Meazura™ Desktop Software CD-ROM is inserted into your computers CD- ROM drive. • Press the power button to turn on your Meazura™ and perform a HotSync operation following the instructions in step 4 to commence the driver install for your Meazura™. • Follow all instructions on your PC and your Meazura™. 2. Connect Figure 1 Figure 2aFigure 2b Figure 3 Figure 4 PC Setup To communicate between the Meazura™ and your PC, you must install ‘Palm Desktop’ located on your CD-ROM included with your kit. 1. Exit all programs, including those that may be running in the taskbar. 2. Insert the Meazura™ Software CD into your CD-ROM drive. 3. The install menu should appear automatically. If it doesn’t then navigate to ‘install_menu.exe’ located on your CD-ROM using Windows Explorer. 4. Follow the on-screen instruction for installing ‘Palm Desktop’. USB ConnectionSerial Connection • Connect your AC adaptor to the bottom of your communications cable (as pictured below in figure 4). • Connect the communications cable to the comms connector located at the bottom of your Meazura™ (as pictured below in figure 4). • Ensure your connection setup is the same as pictured in figure 3 left to commence charging. WARNING: For safety reasons, ensure the Meazura™ is completely dry before using the electrical charger. (Charging time varies depending on battery level) 5. Calibration 7. Contrast/Backlight 4. HotSync® 6. Resetting All Content Copyright © 2004 Aceeca Limited - All Rights Reserved. Aceeca, Meazura, MEZ1000 and RDA are all trademarks of Aceeca Limited. Palm OS, HotSync, Graffiti and the Palm Powered logo are registered trademarks and Palm Powered is a trademark of Palm Trademark Holding Company, LLC. and are used by Aceeca Limited under express license with PalmSource, Inc. All other trademarks referred to in this document are the properties of their respective owners. QSG-MEZ1000-090204 • Ensure Palm Desktop software is installed on your computer (see step 1 ‘Setup’) • Connect the communications cable to your Meazura™ and your computer as per instructions over page in step 2 (‘Connect’). • On your Meazura™ RDA, tap on the HotSync icon (as pictured left). • Tap the large icon in the center of the screen to start the HotSync operation. • Follow all instructions on your PC and your Meazura™. This procedure calibrates the touch sensitive screen on your Meazura™ • Tap on the ‘Prefs’ icon • From the dropdown list, choose “Digitizer” • Follow on-screen instructions Other preferences for setting up your handheld can be found in the drop down list, such as “Date and Time”. To adjust these extra settings, simply tap the setting choice in dropdown list and follow the on-screen instructions. To turn on the backlight, press the Backlight button (pictured right) Press and release Power and Backlight button together Soft Reset (no loss of data) 1. Press and hold the Power and Backlight button together then release the Backlight button only 2. Release the Power button when the Palm Powered logo appears 3. Follow on-screen instructions 1. 2. = Hard Reset (restores Meazura™ to factory settings) Backlight To adjust the contrast of the screen, hold the backlight button for 1.5 seconds to bring up the contrast slider on-screen (as pictured left). • Use your stylus to drag the slider bar until you reach your desired contrast, then click ‘Done’. Contrast EDiT iD Ruggedised Palm Reader Installation Guide 27 July 2005 Page 1 EDiT iD Ruggedised Palm Reader Installation Guide Before you start The Aceeca Palm must have a BigROM Version of MEZ1000503rc3.6 or later to operate the EDIT iD Ruggedised Palm Reader. You can check the version of BigROM your Palm is operating by: 1. Selecting “Device Info” on the main menu. 2. Next to the “BigROM” heading the version of BigROM is displayed. It must be MEZ1000503rc3.6 or later If you do not have or are unsure if you have BigROM MEZ1000503rc3.6 or later call your Aceeca dealer for an upgrade. FCC Statement - FCC ID: RAL-0403 When attached to the Aceeca Meazura TM RDA, This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any Radio or TV interference caused by unauthorised modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. What you need Your Aceeca Palm EDiT iD Ruggedised Palm Reader with the two screws Pozi Drive or Torx Screwdriver to remove existing head (if supplied) Square Head 00 Screw Driver (Adjustable Torque Screwdriver, if available) EDiT iD Ruggedised Palm Reader Installation Guide 27 July 2005 Page 2 How to Install the EDiT iD Ruggedised Palm Reader Important: Before carrying out any of the below steps ensure your Palm and your hands are clean and dry and the Palm is turned off. If your Palm has been supplied without a standard IR head, ple…

Text truncated - open the document above for the full version.

Block Diagram

EDiT iD Limited 1 of 2 Pages EDiT iD Palm Reader Module - System Block Diagram Power Supply/Control Antenna Transmitter 125 kHz or 134.2 kHz FDX Receiver HDX Receiver 2811 DSP 30 Mhz Crystal 75 Mhz Clock MZIO Connector Compact Flash Connector EDiT iD Limited 2 of 2 Pages Connects to ACEECA TM Measura TM platform

External Photos

EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 14 of 19 This report may not be reproduced except in full 9. PHOTOGRAPH (S) External Views

Internal Photos

EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 15 of 19 This report may not be reproduced except in full Internal Views EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 16 of 19 This report may not be reproduced except in full EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 17 of 19 This report may not be reproduced except in full EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 18 of 19 This report may not be reproduced except in full

Operational Description

Ruggedised Palm with Integrated Reader Features  Integrated Unit composed of the Aceeca Meazura Palm and the EDiT iD developed RFID Reader Module  Read Tags up to 140mm from the head of the Palm - ISO 134.2 kHz (HDX* and FDX-B*)  125kHz versions also available  Ruggedised water and dust proof exterior for use in yards, paddocks or industrial settings  Developers notes available for software integration  Optional EDiT Tag Recorder Software . Using this program you can view, add and store animal details  Using the Aceeca Docking Station you can synchronise your PC with the data on the Palm * Read Distances quoted for Allflex 30mm HDX and Zeetag 30mm FDX-B ear tags in optimum orientation

Test Report

EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 1 of 19 This report may not be reproduced except in full TEST REPORT EDiT iD Palm Reader Module RFID Reader tested to 47 Code of Federal Regulations Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators for EDiT iD Ltd This Test Report is issued with the authority of: ______________________________________ Andrew Cutler - General Manager EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 2 of 19 This report may not be reproduced except in full Table of Contents 1. STATEMENT OF COMPLIANCE 3 2. RESULTS SUMMARY 3 3. INTRODUCTION 4 4. CLIENT INFORMATION 4 5. DESCRIPTION OF TEST SAMPLE 5 6. RESULTS 5 7. TEST EQUIPMENT USED 13 8. ACCREDITATIONS 13 9. PHOTOGRAPH (S) 14 EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 3 of 19 This report may not be reproduced except in full 1. STATEMENT OF COMPLIANCE The EDiT iD Palm Reader Module, RFID Reader complies with FCC Part 15 Subpart C as an Intentional Radiator when the methods, as described in ANSI C63.4 - 2003, are applied. 2. RESULTS SUMMARY Clause Parameter Result 15.201 Equipment authorisation requirement Certification required. 15.203 Antenna requirement Complies. Antenna connector unique. 15.204 External PA and antenna modifications Not applicable. No external devices. 15.205 Restricted bands of operation Complies. Device transmits on 125.0 kHz and 134.2 kHz 15.207 Conducted limits Complies with a 8.3 dB margin at 0.5425 MHz (average). 15.209 Radiated emission limits - Fundamental Complies with a 30.9 dB margin at 125.4 kHz. 15.209 Radiated emission limits - Spurious emissions <30 MHz Complies. No emissions detected. 15.209 Radiated emission limits – Spurious emissions >30 MHz Complies with a 15.9 dB margin at 398.0 MHz and 430.9 MHz. EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 4 of 19 This report may not be reproduced except in full 3. INTRODUCTION This report describes the tests and measurements performed on the EDiT iD Palm Reader Module, RFID Reader for the purpose of determining compliance with the specification. The client selected the test sample. This report relates only to the sample tested. This report contains no corrections or erasures. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both Class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. 4. CLIENT INFORMATION Company Name EDiT iD Ltd Address PO Box 11017 Ellerslie City Auckland Country New Zealand Contact Mr Chris Anderson EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 5 of 19 This report may not be reproduced except in full 5. DESCRIPTION OF TEST SAMPLE Brand Name EDiT iD Model Number Palm Reader Module Product RFID Reader, Mobile Manufacturer EDiT iD Ltd Country of Origin New Zealand Serial Number 0F-326-009 (134 kHz), 0G-052-001 (125 kHz) 6. RESULTS Standard The sample was tested in accordance with 47 CFR Part 15 Subpart C. Methods and Procedures The measurement methods and procedures as described in ANSI C63.4 - 1992 were used. Section 15.201: Equipment authorisation requirement Certification as detailed in Subpart J of Part 2 is required for this device. Section 15.203: Antenna requirement As can be seen from the attached photographs the device has an integral antenna that is permanently attached. Result: Complies. EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (…

Text truncated - open the document above for the full version.

Test Setup Photos

EMC Technologies (NZ) Ltd Test Report No 60227.3 Report date: 28 March 2006 __________________________________________________________________________________________________________________________________________________________________________________ EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 19 of 19 This report may not be reproduced except in full Radiated emissions test setups

Contact Information

Applicant

Michael Uganecz(Engineering Manager)
[email protected]0064-9-270-2484Fax: 0064-9-270-2489

Test Firm

EMC Technologies NZ Ltd.Andrew Cutler
[email protected]64-9-360-0862Fax: 64-9-360-0861

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.1342 MHz-
Confidentiality
Long Term

Other Applications from EDiT iD Ltd

Tag Reader - FCC ID RAL-0101 - EDiT iD Ltd
RAL-0101

Tag Reader

Jul 28, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter