FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shanghai Sunray Technology Co., Ltd./
  3. RBC-8009

RBC-8009Transmitter

Shanghai Sunray Technology Co., Ltd.
Transmitter - FCC ID RBC-8009 - Shanghai Sunray Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jan 21, 2013
Application Purpose
Original Equipment
Date of Application
Jan 21, 2013
Equipment Note
Transmitter
Frequency Range
470.00000000 - 470.00000000
Company
Shanghai Sunray Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ShangHai Sunray Technology Co.,Ltd 1 / 17 SRWF-8009 Wireless Meter Reading Module User Manual Version 2.0 ShangHai Sunray Technology Co.,Ltd 2 / 17 Content 1. Product Overview ................................................................................................................................. 3 2. Electric Characteristics and Parameter ................................................................................................. 3 3. Software Function ................................................................................................................................ 5 3.1. Measurement ............................................................................................................................ 5 3.2 Communication Function ......................................................................................................... 8 3.3 Valve Control Function ............................................................................................................ 8 3.4 Battery voltage detection function ............................................................................................ 9 3.5 Alarm function ....................................................................................................................... 10 4 Brief Introduction of Compatibility..................................................................................................... 11 4.1. Pulse Closing Time Requirements ........................................................................................... 11 4.2. Pulse Number Requirements ................................................................................................... 11 4.3. Valve Requirements ................................................................................................................. 11 5 Structure and Installation Size ............................................................................................................ 13 5.1. Structure of the Module .......................................................................................................... 13 5.2. Installation Size of the Module ............................................................................................... 13 6. Communication Tools ........................................................................................................................ 14 6.1. Handheld Unit ........................................................................................................................ 14 6.2. WAMR NET SYSTEM .......................................................................................................... 14 7. Parameter setting ................................................................................................................................ 15 7.1. Brief Introduction of parameter setting software.................................................................... 15 7.2. Relative Terminology Explanation of Parameter Setting ....................................................... 15 8. Certificates ......................................................................................................................................... 15 8.1. Pass CEROHSR&TTE Certificates ................................................................................ 16 8.2. Conform to the IP68 Standard. ............................................................................................... 16 9. Trouble Shooting ................................................................................................................................ 16 9.1. Common Malfunction ............................................................................................................ 16 9.2. Installation Reference ............................................................................................................. 17 ShangHai Sunray Technology Co.,Ltd 3 / 17 1. Product Overview SRWF-8009 is a Wireless Remote Cold Water Meter Module which passed RoHS and meets CE certification, and supports two-way communication. It can remotely turn on/off the valve via background management system. The Background management system can read the meter maximally every 1.5S. Standby current is less than 30uA when no interference. ER18505M battery (3.3A/h) will guarantee 11 years of working time. The modules would take on Anti-rust action for the Meter valve every 10 days to prevent valve stuck during remote valve controlling. Conforming to the IP68 standard test, the modules ensure well function even in humid environment. Wireless Remote Water Meter Module can be compatible with Reed switch metering sensor, Pairs measured at the Hall element sensor, Hall element metering sensor, Photoelectric direct reading measurement sensor. 2. Electric Characteristics and Parameter No. Description Parameter Notes Unit Min Typical Max 1 Power supply V 3.2 3.6 4.0 Power type lithium thionyl chloride battery 2 Working current uA 110 120 3 Reading interval S 1 1.5 4 Working temperature 25 25 65 5 Transmit Frequency MHz 470 6 Reliable m 200 250 Open field ShangHai Sunray Technology Co.,Ltd 4 / 17 Transmitting Distance 7 Modulation mode FSK 8 Channel 1 User can’t set the channel 9 Lifetime year 10 10 Driving current of valve mA 100 250 11 Reed switch module pin pull-up resistors KΩ 1.98 2 2.02 12 Hall component pin input impedance MΩ 60 13 Photoelectric direct reading module output voltage V 3.2 3.6 4 14 Photoelectric direct reading module output current mA 100 Photoelectric meter power supply 15 UART Port compatibility level V 3 ShangHai Sunray Technology Co.,Ltd 5 / 17 3. Software Function 3.1. Measurement 3.1.1. Double Reed Switch 3.1.1.1 Reed switch module pin connection NO Wire Colour Pin Function 1 Black Common Ground 2 Purple Reed switch B 3 Green Reed switch A 3.1.1.2 AB Reed switch pulse input timing diagram A Reed switch B Reed switch t1 t2 t3 NOState Input low pulse time requirement M…

Text truncated - open the document above for the full version.

External Photos

EXTERNAL PHOTO

ID Label/Location Info

Label location

Internal Photos

Antenna

Test Report

TEST REPORT Report No.: EM201200699 Application No.: ZJ00022182 Client: Shanghai Sunray Technology Co., Ltd. Address: 8F, Bei Da 2, NO.560 Sheng Xia Rd, Pudong Zhangjiang, Shanghai, China Sample Description: Micro Power Wireless Data Module Model: FCC ID: SRWF-8009 RBC-8009 Test Location: Guangzhou GRG Metrology and Test Co., Ltd. Test Specification: FCC Part 15,Subpart C:2010 Test Date: 2012-11-01 to 2012-11-29 Issue Date: 2012-11-28 Test Result: Pass. Prepared By: Reviewed By: Approved By: David Li / Test Engineer Jane Cao / Test Engineer Gavin Wu / Manager Date:2012-12-4 Date:2012-12-4 Date:2012-12-4 Other Aspects: / Abbreviations: ok / P = passed; fail / F = failed; n.a. / N = not applicable The test result in this test report refers exclusively to the presented test sample. This report shall not be reproduced except in full, without the written approval of GRGT. GRG Metrology and Test Co., Ltd. Address: 163, Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, P.R. China Tel:+86-20-38699960 Fax:+86-20-38695185 Email: [email protected] http://www.grgtest.com Ver.:2.0 / 01.Jan.2012 Report No.: EM201200699 Application No.: ZJ00022182 Page 2 of 26 FCC ID: RBC-8009 DIRECTIONS OF TEST 1. This station carries out test task according to the national regulation of verifications which can be traced to National Primary Standards and BIPM. 2. The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. 3. If there is any objection concerning the test, the client should inform the laboratory within 15 days from the date of receiving the test report. Report No.: EM201200699 Application No.: ZJ00022182 Page 3 of 26 FCC ID: RBC-8009 Table of Contents 1. TEST RESULT SUMMARY ............................................................................................................................................... 4 2. GENERAL DESCRIPTION OF EUT................................................................................................................................. 5 2.1 APPLICANT .................................................................................................................................................................... 5 2.2 MANUFACTURER ......................................................................................................................................................... 5 2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST ............................................................................................. 5 3. LABORATORY AND ACCREDITATIONS ..................................................................................................................... 6 3.1 LABORATORY ............................................................................................................................................................... 6 3.2 ACCREDITATIONS ....................................................................................................................................................... 6 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................................... 6 3.4 LIST OF USED TEST EQUIPMENT AT GRGT ............................................................................................................. 7 4. TEST RESULTS ................................................................................................................................................................... 8 4.1 E.U.T. TEST CONDITIONS ............................................................................................................................................ 8 4.2 ANTENNA REQUIREMENT ......................................................................................................................................... 9 4.3 OCCUPIED BANDWIDTH ........................................................................................................................................... 10 4.3.1 LIMITS .................................................................................................................................................................... 10 4.3.2 TEST PROCEDURES ............................................................................................................................................. 10 4.3.3 TEST SETUP .......................................................................................................................................................... 10 4.3.4 TEST RESULTS ...................................................................................................................................................... 10 4.4 DWELL TIME................................................................................................................................................................ 12 4.4.1 LIMITS .................................................................................................................................................................... 12 4.4.2 TEST PROCEDURES ............................................................................................................................................. 12 4.4.3 TEST SETUP .......................................................................................................................................................... 12 4.4.4 TEST RESULTS ...................................................................................................................................................... 13 4.5 FIELD STRENGTH OF FUNDAMENTAL .................................................................................................................. 14 4.5.1 LIMITS .............................................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOS

Contact Information

Applicant

DIQIAN WU(Manager)
[email protected]021-50275250Fax: 021-50270187

Technical Contact

GUANGZHOU GRG METROLOGY&TEST CO.,LTD.Cao Jane
[email protected]86-20-39699960-341

163 Ping Yun Rd,West of HuangPu Ave, Β· Guangzhou Β· China

Test Firm

Guangzhou GRG Metrology And Test Technology LTD.Huang Yingling
[email protected]2038699960Fax: 86 20 38698685

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)470 MHz - 470 MHz-
Confidentiality
Long Term

Other Applications from Shanghai Sunray Technology Co., Ltd.

Micro Power Wireless Data Module - FCC ID RBC-8009G - Shanghai Sunray Technology Co., Ltd.
RBC-8009G

Micro Power Wireless Data Module

Jan 27, 2016

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Micro Power Wireless Data Module - FCC ID RBC-1022 - Shanghai Sunray Technology Co., Ltd.
RBC-1022

Micro Power Wireless Data Module

May 13, 2014

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver