
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USE AND CARE GUIDE WINDWARD IV 52-INCH CEILING FAN Questions, problems, missing parts? Before returning to the store, call Home Decorators Collection Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday. 1-800-986-3460 HOMEDEPOT.COM/HOMEDECORATORS THANK YOU We appreciate the trust and confidence you have placed in Home Decorators Collection through the purchase of this ceiling fan. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Home Decorators Collection! Item #1000 020 187, 458 633, 458 611, 458 301 Model #26666, 26662, 26661, 26663 UL Model #52-WWDIV 2 Table of Contents ................................................................ 2 Safety Information ............................................................... 2 Warranty ............................................................................... 3 Pre-Installation .................................................................... 3 Installation............................................................................ 6 Assembly .............................................................................. 7 Operation ........................................................................... 15 Care and Cleaning ............................................................. 16 Troubleshooting................................................................. 16 1.To reduce the risk of electric shock, ensure the electricity has been turned off at the circuit breaker or fuse box before you begin. 2.All wiring must be in accordance with the National Electrical Code ANSI/NFPA 70-1999 and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3.The outlet box and support structure must be securely mounted and capable of reliably supporting 35 lbs. (15.9 kg). Use only UL Listed outlet boxes marked “Acceptable for Fan Support of 35 lbs. (15.9 kg) or less.” 4.The fan must be mounted with a minimum of 7 ft (2.1 m) clearance from the trailing edge of the blades to the floor. 5.Do not operate the reversing switch while the fan blades are in motion. You must turn the fan off and stop the blades before you reverse the blade direction. 6.Do not place objects in the path of the blades. 7.Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL-listed and marked suitable for use with the model fan you are installing. Switches must be UL General Use Switches. Refer to the instructions packaged with the light kits and switches for proper assembly. 8.After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box. 9.All setscrews must be checked and retightened where necessary before installation. WARNING: To reduce the risk of personal injury, do not bend the blade brackets (also referred to as flanges) during assembly or after installation. Do not insert objects in the path of the blades. WARNING: To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked “acceptable for fan support of 35lbs. (15.9 Kg) or less” and use screws provided with the outlet box. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. WARNING: To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring. If you feel you do not have enough electrical wiring knowledge or experience, contact a licensed electrician. WARNING: Electrical diagrams are for reference only. Optional use of any light kit shall be UL-listed and marked suitable for use with this fan. WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. FAN28R-240W manufactured by Chia Wei Electric Co., LTD. Safety Information Table of Contents CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box. CAUTION: To avoid personal injury or damage to the fan and other items, use caution when working around or cleaning the fan. READ AND SAVE THESE INSTRUCTIONS. This device complies with part 15 of the FCC rules, operation is subject to the following two conditions. (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 3 HOMEDEPOT.COM/HOMEDECORATORS Please contact 1-800-986-3460 for further assistance. Pre-Installation Warranty The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date of purchase by the original purchaser. The supplier also warrants that all other fan parts, excluding any glass or acrylic blades, to be free from defects in workmanship and material at the time of shipment from the factory for a period of two years after the date of purchase by the original purchaser. We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned. To obtain warranty service, you must present a copy of the receipt as proof of purchase. All costs of removing and reinstalling the product are your responsibility. Damage to any part such as by accident, misuse, improper installation, or by affixing any accessories, is not covered by this warranty. Because of varying climatic conditions this warranty does not cover any changes in brass finish, including rusting, pitting, corroding, tarnishing, or peeling. Brass finishes of this type give…
Text truncated - open the document above for the full version.
DATE : April 02, 2015 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint _ Shenzhen Timeway Technology Consulting Co., Ltd. East 5/Block 4, Anhua Industrial Zone, No.8,Tairan Rd. CheGongMiao, FuTian District, Shenzhen City, Guangdong Province, China_, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with King of Fans, Inc. 1951 N.W. 22 nd Street,Fort Lauderdale, FL33311,USA Dated this April 02, 2015 By: Rivera Eli Signature Printed Title: Manager On behalf of : King of Fans, Inc. Telephone: 954 484 7500
DATE: April 03, 2015 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: RGB-52WWDIVC Product Name: 52 inch Windward IV Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operational Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this April 03, 2015 By: Rivera Eli Signature Printed Title: Manager On behalf of : King of Fans, Inc. Telephone: 954 484 7500
Photo for the EUT Photo for the EUT Photo for the EUT Photo for the EUT Photo for the EUT Photo for the EUT
FCC ID: RGB-52WWDIVC . R O O L F O T S E D A L B K S I R E C U D E R O T : - T N I A M , S N O S R E P O T Y R U J N I F O NO: I . M S . P O U R G T A N I N W T : O T L H L I S O F P R E O H D T U F C O T E A R N O D / O M R R C O O E M N P O O Y N B E N D T S E R E A R E C O V P . A G T N E I N D T N S E : P 5 , 9 S 4 T 7 , N 4 3 E 6 T ; A 5 P , 9 8 R 8 E , 5 H 8 0 T ; O 5 , D 9 7 N 1 , 5 A 7 6 3 1 ; , 4 6 6 , 0 4 1 , 0 0 6 , 1 ; 1 0 1 ; 6 , 5 4 , 0 1 , 0 3 9 0 , 3 0 6 ; 6 I M S P E O T R N T E A T N A T P E E : T E S N T E E N P G I R S O S D O U L C T E O D Y O / N O U L O R S O C P O O M D P I E O R N B E N U T E N C S EST A 08-2013 A M E R I C A N O S : 5 , 9 4 7 , 4 3 6 ; 5 , 9 8 8 , 5 8 0 ; 5 , 9 7 1 , 5 7 3 ; 6 , 0 1 0 , 1 1 0 ; 6 , 0 1 0 , 306; E T N E I D N E P S E T N E T A P S O R T O Y ; 6 1 4 , 6 4 0 , 6 ; 1 4 , 5 9 3 , 0 6 U P C # 0 8 2 3 9 2 2 6 6 6 3 9 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operat ion. Este dispositivo cumple con la parte 15 de las regulaciones de la FCC. La operación está sujeta a las dos condiciones siguientes: (1) este dispositivo no debe causar interferencia dañina y (2) este dispositivo debe aceptar cualquier interferencia, incluso aquella que pueda afectar su funcionamiento correcto.
Mark Location: Label Location
Photo for the EUT Photo for the EUT Photo for the EUT Photo for the EUT
ISO/IEC17025 Accredited Lab. Report No: FCC 1503195 File reference No: 2015-04-03 Applicant: King of Fans, Inc. Product: 52’’ Windward IV Model No: 52-WWDIV Trademark: N/A Test Standards: FCC Part 15 Subpart B: 2012 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: April 03, 2015 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Room 512-519, 5/F., East Tower, Building 4, Anhua Industrial Zone, Futian District, Shenzhen, Guangdong, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: FCC1503195 Page 2 of 30 Date: 2015-04-03 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC- Registration No.: IC5205A-02 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-02. Report No: FCC1503195 Page 3 of 30 Date: 2015-04-03 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT ............................................................................................4 1.4 Test Uncertainty................................................................................................ 4 1.5 Submitted Sample............................................................................................. 4 1.6 Test Duration.................................................................................................. 4 2.0 List of Measurement Equipment........................................................................ 5 2.1 Conducted Emission Test..................................................................................... 5 2.2 Radiated electromagnetic disturbance test................................................................. 5 2.3 Auxiliary Equipment.......................................................................................... 5 3.0 Technical Details............................................................................................. 6 3.1 Investigations Requested..................................................................................... 6 3.2 Test Standards.................................................................................................. 6 4.0 Power line Conducted Emission Test..................................................................... 7 5.0 Radiated Disturbance Test................................................................................... 11 6.0 FCC ID Label ....................................................................................................... 18 7.0 Photo of testing........................................................................................................................... 19 Report No: FCC1503195 Page 4…
Text truncated - open the document above for the full version.
Conducted test View-- Radiated emission test view--
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 303.9 MHz - 303.9 MHz | - |

Low Voltage smart transformer
Equipment Class
DTS - Digital Transmission System
60in Feldner (was Shuri)
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
52 in Campbell, 91350/91359
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
52 in Junedale (was Sarasota) 52188
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
54 Inch Fanelee 52133
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter