Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 24, 2007
Application Purpose
Original Equipment
Date of Application
Oct 24, 2007
Equipment Note
60 GHz Transceiver
Frequency Range
58780.00000000 - 62260.00000000
Company
Comotech Corporation
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Millimeter-wave Radio Communication System Installation and Service Manual TM 60 Series - ME1000/100 70 Series - TE1000/100 COMOTECH CORPORATION TM 60 Series – ME1000 / ME100 70 Series – TE1000 / TE100 Copyright ©2004 Comotech Corp. All Rights Reserved. Comotech Corp. has an exclusive right to the information included in this document, and this matter is protected by the related copyright, patent, and intellectual property right. The products and software stated in this document can’t be translated into another language by arbitrary forms or ways without the written consent of Comotech Corp. and can’t be kept, photocopied, delivered, or reorganized into storage media. Comotech products are explained in this document to simply provide the information. It doesn’t guarantee the matters indicate or include the future performance improvement. The Comotech product design and performance can be changed without prior notice or consent. The registered unique marks and trademark rights such as the products and company names indicated in this document are owned by individual companies and used for verification or explanation not to damage the owner’s profit. 1. Introduction 1-1. AirLight™ Family .................................................... 1-1 1-2. Advantages of AirLight™ Series .................................................... 1-1 1-3. AirLight™ Features .................................................... 1-2 1-4. AirLight™ Application .................................................... 1-3 2. Description 2-1. General Equipment .................................................... 2-1 3. Deployment 3-1. Pre-Installation Notice .................................................... 3-1 3-2. Installed-Location Notice .................................................... 3-2 3-3. Safety and Notice .................................................... 3-3 3-4. Tools and Equipments .................................................... 3-5 3-5. How to Connect AirLight™ .................................................... 3-6 3-6. Cabling Check .................................................... 3-12 4. AirLight™ Monitoring Program(ALMP) 4-1. Introduction .................................................... 4-1 4-2. Installation .................................................... 4-2 4-3. Getting Start .................................................... 4-3 5. Troubleshooting 5-1. General ALMP Features .................................................... 5-1 5-2. Problem Solving .................................................... 5-1 6. Specification 6-1. AirLight 60 Series Specification .................................................... 6-1 6-2. AirLight 70 Series Specification .................................................... 6-2 7. Terminal Location .................................................... 7-1 8. Warranty .................................................... 8-1 ★ Table of Contents ★ 1 - 1 Introduction 1. Introduction 1-1. AirLight™ Family AirLight™ applies the original Comotech technology to millimeter-wave and provides the system doing the wireless transmission of various types of digital signals from 100 Mbps to 1.25Gbps. Especially, Fast Ethernet (125 Mbps) and Gigabit Ethernet (1.25Gbps) are provided with standards, and product flexibility is provided to determine the desired standards depending on user requirements. 1-2. Advantages of AirLight™ Series √ High Tech – Application of original Comotech technology has further enhanced the reliability of millimeter wave band products. √ Unlicensed Frequency Band – There are many countries that generally don’t need license and declare to use the frequency in case of 60 series. √ High Data Transmission Speed – The systems with various speeds from 100 Mbps to 1.25Gbps can be serviced and supported. √ High Security and Frequency Reuse – Good security is guaranteed by high directivity, and the reuse of frequency in the unit of pico cell is possible due to the frequency characteristics of the millimeter wave. TE1000C-24/ME1000C-24 TE1000C-12/ME1000C-12 TE100C-24/ME100C-24 TE100C-12/ME10C-12 Figure 1-1 AirLight™ ODU (Out Door Unit) Introduction - 60 / 70 Series 1 - 2 1-3. AirLight™ Features AirLight™ has the following features. ▶ Next Generation Communication Technology √ Integration of high tech √ Digital direct conversion √ Good security √ Data acceptance capability with high capacity √ Low power consumption ▶ Wireless and Fiber Distributed Network Configuration √ Use of the unlicensed frequency in the 60GHz band – ME100 / ME1000 √ Possible to connect to the system using binary digital signals √ Support of the maximum 1.25Gbps (Gigabit Ethernet) speed from 100 Mbps √ Support of various interfaces: FDDI, UTP, etc. √ Possible to design in compliance with the communication regulation of each country ( FCC, TELEC, ITU-R) ▶ Low Cost and High Efficiency √ Possible to configure very high speed network with the low cost √ Low maintenance and repair cost without laying √ Possible to install and operate with the small number of persons (1 or 2 persons) √ Possible to send the data with high capacity and flexibly connect to another system √ Possible to connect to IP network √ The same transmission efficiency as the wired one COMOTECH CORPORATION 1 - 3 Introduction ▶ Efficient Network Management √ Provision of the efficient network management program (IDU) √ Support of the RS-485 communication port to check the AirLight™ state √ The management function by ALMP, AirLight™ Monitoring Program 1-4. AirLight™ Application AirLight™ is a ultra high speed wireless LAN communication product. Configuring the wireless network with P2P, P2M, or M2P types among large buildings makes it possible to communicate the data with the adjacent system through the wireless network. This configuration can replace the area difficult to lay the optical cables and communication facilities requiring high security. The wired and wireless double security management system,…

Text truncated - open the document above for the full version.

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: RL3ALME1000 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Tae Ho Lee/Director 1-908, Ulsan APT-Bldg., 812-1, Hyomun-Dong, Buk-Gu, Ulsan City, 683-360, Korea 82-52-288-7550

Cover Letter(s)

Circuit Schematics Circuit Layout Functional and controls algorithm Microprocessor programs Detailed mechanical designs and drawings Bill of material for circuit components/component type/part number Internal photos

External Photos

Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 44 of 52 FCC 15.255 14 EXHIBIT C - EUT PHOTOGRAPHS 14.1 EUT - Front View (24 inch Antenna) 14.2 EUT - Rear View (with 24 inch Antenna) Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 45 of 52 FCC 15.255 14.3 EUT - Front View (12 inch Antenna) 14.4 EUT - Rear View (12 inch Antenna)

ID Label/Location Info

Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 36 of 52 FCC 15.255 12 EXHIBIT A - FCC ID LABEL INFORMATION 12.1 FCC § 2.925 Identification of equipment (a) Each equipment covered in an application for equipment authorization shall bear a nameplate or label listing the following: (1) FCC Identifier consisting of the two elements in the exact order specified in §2.926. The FCC Identifier shall be preceded by the term FCC ID in capital letters on a single line, and shall be of a type size large enough to be legible without the aid of magnification. Example: FCC ID XXX123. XXX—Grantee Code 123—Equipment Product Code 12.2 Suggested Content of FCC ID Label 12.3 Label Location on EUT FCC Label shall be "Permanently affixed" meaning that the label is etched, engraved, stamped, silk- screened, indelibly printed, or otherwise permanently marked on a permanently attached part of the equipment or on a nameplate of metal, plastic, or other material fastened to the equipment by welding, riveting, or a permanent adhesive. The label must be designed to last the expected lifetime of the equipment in the environment in which the equipment may be operated and must not be readily detachable. Model: ME1000C-12, ME1000C-24 1) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2) This device meets the radiofrequency radiation exposure requirements specified in §1.1307(b), 2.1091 and 2.1093 of the FCC rules for both fundamental and spurious emissions as required under Part 15. FCC ID: RL3ALME1000 Commotech Corporation IC:

Test Report

2 Note: This test report is for the customer shown above and their specific product only. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government (REV.1) FCC PART 15.255 MEASUREMENT AND TEST REPORT For ComoTech Corporation 1-908, Ulsan APT-Bldg., 812-1, Hyomun-Dong, Buk-Gu, Ulsan City, 683-360 Korea FCC ID: RL3ALME1000 Report Type: Original Report Product Type: 60 GHz Point-to-Point Transceiver Test Engineer: James Ma Report Number: R0709283 Report Date: 2007-10-15 Reviewed By: Choon Sian Ooi: Test Engineer Prepared By: (J8) Bay Area Compliance Laboratories Corp. (BACL) 1274 Anvilwood Ave. Sunnyvale, CA 94089, USA Tel: (408) 732-9162 Fax: (408) 732-9164 Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 2 of 52 FCC 15.255 TABLE OF CONTENTS 1 GENERAL INFORMATION ..............................................................................................................................4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .......................................................................4 1.2 MECHANICAL DESCRIPTION OF EUT ..............................................................................................................4 1.3 EUT PHOTOGRAPH.........................................................................................................................................4 1.4 OBJECTIVE......................................................................................................................................................5 1.5 RELATED SUBMITTAL(S)/GRANT(S)................................................................................................................5 1.6 TEST METHODOLOGY.....................................................................................................................................5 1.7 MEASUREMENT UNCERTAINTY.......................................................................................................................5 1.8 TEST FACILITY................................................................................................................................................6 2 SYSTEM TEST CONFIGURATION .................................................................................................................7 2.1 JUSTIFICATION................................................................................................................................................7 2.2 EQUIPMENT MODIFICATIONS..........................................................................................................................7 2.3 EUT EXERCISE SOFTWARE.............................................................................................................................7 2.4 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS...........................................................................................7 2.5 POWER SUPPLY INFORMATION........................................................................................................................7 2.6 INTERFACE PORTS AND CABLING....................................................................................................................7 2.7 TEST SETUP BLOCK DIAGRAM........................................................................................................................8 3 SUMMARY OF TEST REPORT ........................................................................................................................9 4 §15.203 – ANTENNA REQUIREMENT ..........................................................................................................10 4.1 APPLICABLE STANDARD...............................................................................................................................10 4.2 RESULT.........................................................................................................................................................10 5 §15.207 – POWER LINE CONDUCTED EMISSIONS ..................................................................................11 5.1 SECTION 15.207 CONDUCTED LIMITS:...........................................................................................................11 5.2 TEST SETUP..................................................................................................................................................11 5.3 TEST EQUIPMENT LIST AND DETAILS............................................................................................................11 5.4 TEST PROCEDURE.........................................................................................................................................12 5.5 ENVIRONMENTAL CONDITIONS.....................................................................................................................12 5.6 SUMMARY OF TEST RESULTS........................................................................................................................12 5.7 CONDUCTED EMISSION TEST PLOT AND DATA.............................................................................................13 6 §15.209, §15.255 (C), (2), (3) – TRANSMITTER SPURIOUS EMISSIONS .................................................15 6.1 APPLICABLE STANDARD...............................................................................................................................15 6.2 TEST PROCEDURE.........................................................................................................................................15 6.3 TEST EQUIPMENT LIST AND DETAILS............................................................................................................16 6.4 ENVIRONMENTAL CONDITIONS....................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 37 of 52 FCC 15.255 13 EXHIBIT B - TEST SETUP PHOTOGRAPHS 13.1 Conducted Emissions – Front View 13.2 Conducted Emissions – Side View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 38 of 52 FCC 15.255 13.3 (30 MHz - 1GHz) Radiated Emission 24 inches Antenna – Front View 13.4 (30 MHz - 1GHz) Radiated Emission 24 inches Antenna – Rear View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 39 of 52 FCC 15.255 13.5 (30 MHz - 1GHz) Radiated Emission 12 inches Antenna – Front View 13.6 (30 MHz - 1GHz) Radiated Emission 12 inches Antenna – Rear View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 40 of 52 FCC 15.255 13.7 (1 GHz – 20 GHz) Radiated Emission 24 inches Antenna – Front View 13.8 (1 GHz – 20 GHz) Radiated Emission 24 inches Antenna – Rear View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 41 of 52 FCC 15.255 13.9 (1 GHz – 20 GHz) Radiated Emission 12 inches Antenna – Front View 13.10 (1 GHz – 20 GHz) Radiated Emission 12 inches Antenna – Rear View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 42 of 52 FCC 15.255 13.11 (20 GHz – 140 GHz) Radiated Emission 24 inches Antenna – Front View 13.12 (20 GHz – 140 GHz) Radiated Emission 24 inches Antenna – Rear View Commotech, Corp. FCC ID:RL3ALME1000 Report #: R0709283 Page 43 of 52 FCC 15.255 13.13 (20 GHz – 140 GHz) Radiated Emission 12 inches Antenna – Front View 13.14 (20 GHz – 170 GHz) Radiated Emission 12 inches Antenna – Rear View

Contact Information

Applicant

InJun Park(General Manager)
[email protected]82.52.288.7550Fax: 82.52.288.7551

Test Firm

Bay Area Compliance LaboratoryJohn Chan
[email protected]408-732-9162Fax: 408-732-9164

Technical Specifications

#Rule PartsFrequency RangePower Output
115C58.78 GHz - 62.26 GHz-
Confidentiality
Long Term
Grant Notes
Maximum power listed is conducted. This device can employ either of two antennas; a 24" Cassegrain antenna with 47 dBi gain and a 12" Cassegrain antenna with 43 dBi gain. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance.

Other Applications from Comotech Corporation

70 GHz Transceiver - FCC ID RL3ALTE1000 - Comotech Corporation
RL3ALTE1000

70 GHz Transceiver

Jan 29, 2006

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
60GHz Transceiver - FCC ID RL3ALME100 - Comotech Corporation
RL3ALME100

60GHz Transceiver

Dec 21, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter