FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Entel UK Limited/
  3. RV6HT880

RV6HT880FM Handheld Submersible Transceiver HT880

Entel UK Limited
FM Handheld Submersible Transceiver HT880 - FCC ID RV6HT880 - Entel UK Limited
Click to zoom

Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Nov 04, 2005
Application Purpose
Original Equipment
Date of Application
Nov 04, 2005
Equipment Note
FM Handheld Submersible Transceiver HT880
Frequency Range
440.00000000 - 470.00000000
Company
Entel UK Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

o{_YWV__W }omV|omGšœ‰”Œ™š‰“ŒG›™ˆ•šŠŒŒ™š v~ulyzGthu|hs |sGjŒ™›Œ‹ p•›™•šŠˆ““ GzˆŒ j“ˆššGpSGkGp n™–œ—šGhSiSjSkGG{Z Oj“ˆššGpSG–•ŒGWSGppjP zœ‰”Œ™š‰“Œ kŒ—Œ•‹ˆ‰“Œ {–œŽ CE COMPLIANCE STATEMENT The HT800 series transceiver displays "CE" on the serial number label, indicating its compliance with the essential requirements of the EEC directive for Electromagnetic Compatibility. DECLARATION OF CONFORMITY We Entel UK Limited, OF: 3rd Floor, Ridgehill House, Elstree Way Borehamwood, Herts WD6 1JL United Kingdom Declare under our sole responsibility that the product:- HT800 series VHF/UHF handheld transceiver Serial Number To which this declaration relates, is in accordance with directive 95/5/EC and conforms to the following standard or other nominative documents:- EN 300 086-2 V1.1.1, EN 301 489-1 V1.5.1:2003, EN 60065:2002 Following provisions of the R&TTE directive. ISO 9001 REGISTERED FIRM M. Austin. Quality Manager Y Z XUXGnlulyhsGmlh{|ylz XUYGwhjrpunGspz{ XUZGvw{pvuzGOhjjlzzvyplzP XUZUXGh{{hjopunGh|kpvGhjjlzzvyplz XU[Gjvu{yvszGhukGpukpjh{vyz XU\GsjkGpukpjh{vyz XU]Gyljlw{pvu XU^G{yhuztp{{pun XU_Ghkkp{pvuhsGmlh{|ylz XU`G}vGO–ŠŒG–—Œ™ˆ›Œ‹G›™ˆ•𔐛P YUWGvw{pvuhsG{ypjrslGjohynlyT”–‹Œ“GjjhYZW YUXGvw{pvuhsGjohynlyT”–‹Œ“Gjzh][Wl YUYGih{{ly€Gpukpjh{vy YUZGih{{ly€Gzhml{€ YU[G{yv|islGzovv{pun YU\Gzwljpmpjh{pvuGOnŒ•Œ™ˆ“SG™ŒŠŒŒGˆ•‹G›™ˆ•𔐛P YU]Gzhml{€G{yhpupunGpumvyth{pvu YU^Guv{lz W[ W[ W\ W] W` XW XX XX XY XY XZ XZ X[ X\ X] X^ YW YY {hislGvmGjvu{lu{z [ |UsGjŒ™›Œ‹G•›™•šŠˆ““ GšˆŒG oŒˆ G‹œ› SGŠ–””Œ™Šˆ“GŽ™ˆ‹ŒGŠ–•š›™œŠ›–• zœ‰”Œ™š‰“ŒGVGmœ““ Gžˆ›Œ™—™––G›–Gqpz^ XY_GwjG—™–Ž™ˆ””ˆ‰“ŒGŠˆ••Œ“š h““Gj{jzzGMGkjzG›–•Œš zŠˆ•G”–‹Œ mŒG—™–Ž™ˆ””ˆ‰“ŒG‰œ››–•š s›œ”T“–•G‰ˆ››Œ™ G›ŒŠ•–“–Ž X[G–œ™G‹œ› GŠ Š“Œ }vGO–ŠŒG–—Œ™ˆ›Œ‹G›™ˆ•𔐛P s–žG‰ˆ››Œ™ Gžˆ™••ŽG‰“ŒŒ— iˆ››Œ™ G“ŒŒ“G•‹Šˆ›–™ lŸ›Œ•šŒG™ˆ•ŽŒG–GˆŠŠŒšš–™Œš XU YU ZU [U \U ]U ^U _U `U XWU XXU XYU XZU XUXGnlulyhsGmlh{|ylz {ŒGšœ——“Œ‹G—ˆŠ’ˆŽŒaGO|UsGjŒ™›Œ‹SG•›™•šŠˆ““ GšˆŒP G GGGGGGo{_YWV__W GGGGGGjui_[Wl GGGGGGjio`[W GGGGGGjh{YWV_W GGGGGGvž•Œ™šG”ˆ•œˆ“GG {™ˆ•šŠŒŒ™ X_WW”hG™ŒŠˆ™ŽŒˆ‰“ŒG“›œ”T“–•G‰ˆ››Œ™ G—ˆŠ’ z—™•ŽG“–ˆ‹Œ‹G™Œˆ™GŠ“— oŽGŒŠŒ•Š Gˆ•›Œ••ˆ XUYGwhjrpunGspz{ \ {ŒGo{_WWGzŒ™ŒšGšGšœ——–™›Œ‹G‰ GˆGž‹ŒG™ˆ•ŽŒG–GœšŒœ“GˆŠŠŒšš–™ŒšUG m–™Gˆ•Gœ—G›–G‹ˆ›ŒG“š›Gš›G–œ™GžŒ‰Gš›ŒGˆ›GžžžUŒ•›Œ“UŠ–Uœ’ jzh][WlG jzi][WlGG jz{][Wl jjhYZW jjhXYG jui_[WlG jtw_[WGG lhX`V_[WGG lhX\V][WGG lw{[WV_[WGGG jow_[WVokGG jow_[WVozGG jow_[WkGG G jy\V_[WGG jyX]V_[WGG G low_[WGGG jsj`[W j~][WGG jh{YW}z jh{_W|z jh{YW jh{_WGGGGGGGGGG jio`[WG G z•Ž“ŒG—–‹G•›Œ““ŽŒ•›G™ˆ—‹GŠˆ™ŽŒ™SGXXWVYZWG–—Œ™ˆ›–• zŸG—–‹G•›Œ““ŽŒ•›G™ˆ—‹GŠˆ™ŽŒ™SGXXWVYZWG–—Œ™ˆ›–• ZG–™G]G—–‹G‰ˆ››Œ™ GŠ–•‹›–•Œ™Vˆ•ˆ“ šŒ™G YZWG‹™–—G•G›™Š’“ŒGŠˆ™ŽŒ™UGOh“š–Gˆˆ“ˆ‰“ŒGˆšGXXWGTjjhXXWP XYG‹™–—G•G›™Š’“ŒGŠˆ™ŽŒ™ ^U[}GX_WW”hG™ŒŠˆ™ŽŒˆ‰“ŒG“›œ”Tp–•G‰ˆ››Œ™ G—ˆŠ’SGž›G™Œˆ™GŠ“— zœ‰”Œ™š‰“ŒSG•–šŒGŠˆ•ŠŒ““•ŽGš—Œˆ’Œ™G”Š™–—–•ŒGOŒˆ G‹œ› P lˆ™—ŒŠŒG”Š™–—–•ŒGž›Gw{{G‰œ››–•GO–ŸP j–Œ™›Gš› “ŒGŒˆ™V”Š™–—–•ŒGž›G›™ˆ•š—ˆ™Œ•›GˆŠ–œš›ŠG›œ‰Œ i–•ŒGŠ–•‹œŠ›ŒGŒˆ™—ŒŠŒG”Š™–—–•ŒGO–ŸPG oŒˆ G‹œ› G‹–œ‰“ŒGŒˆ™G‹ŒŒ•‹Œ™G–™Gˆ™‹ˆ›Gž›Gw{{GO–ŸP oŒˆ G‹œ› Gš•Ž“ŒGŒˆ™G‹ŒŒ•‹Œ™G–™Gˆ™‹ˆ›Gˆ•‹Gw{{GO–ŸP oŒˆ G‹œ› G‹–œ‰“ŒGŒˆ™G‹ŒŒ•‹Œ™Gž›GŒˆ‹‰ˆ•‹Gˆ•‹Gw{{GO–ŸP z’œ““G”Š™–—–•ŒGO–ŸP {™–ˆ›G”Š™–—–•ŒGO–ŸP G j–Œ™›Gš› “ŒGŒˆ™—ŒŠŒG oŒˆ G‹œ› G“Œˆ›Œ™GŠˆšŒGž›G‰Œ“›G“––—GMGŠˆ™™ Gš›™ˆ— h•›Œ••ˆGˆ‹ˆ—›–™G–™GŒŸ›Œ™•ˆ“GˆŒ™ˆ“GŠ–••ŒŠ›–• z›œ‰‰ Gˆ•›Œ••ˆG}om z›œ‰‰ Gˆ•›Œ••ˆG|om oŽGŒŠŒ•Š Gˆ•›Œ••ˆSG}om oŽGŒŠŒ•Š Gˆ•›Œ••ˆSG|om z—™•ŽG“–ˆ‹Œ‹G™Œˆ™GŠ“— XUZGvw{pvuhsGhjjlzzvyplzGO|UsGjŒ™›Œ‹P hŠŠŒšš–™ŒšGšœ›ˆ‰“ŒG–™G–ŸG–—Œ™ˆ›–•GˆŒG‰ŒŒ•G”ˆ™’Œ‹GO–ŸP uv{laGkvGuv{GjohynlGvyGyltv}lG{olGih{{ly€GwhjrGpuG{olG GGGGGGGGGGGGohhykv|zGhylhGsvjh{pvuU uv{laG{olG|zlGvmGuvuGlu{lsGhwwyv}lkGhjjlzzvyplzG~pssG GGGGGGGGGGGGpu}hspkh{lG€v|yG|UsGpu{ypuzpjhss€GzhmlGhwwyv}hs ] s–Šˆ›ŒGˆŠŠŒšš–™ GŠ–••ŒŠ›–™GŠ–Œ™G”ˆ™’Œ‹GIhjjIGs›GŠ–Œ™Gˆ•‹G ™–›ˆ›ŒGOšŠ™ŒžPG›ŒGŠ–••ŒŠ›–™GŠ“–Š’žšŒU XUZUXGh{{hjopunGh|kpvGhjjlzzvyplz XUGh››ˆŠ•ŽG›ŒG‰Œ“›GŠ“—bGh“Ž•G›ŒG‰Œ“›GŠ“—Gž›G›ŒG—“ˆš›Š GGGGš“–›šG–G›ŒG‰ˆ››Œ™ G—ˆŠ’UGz“‹ŒG›ŒG‰Œ“›GŠ“—G‹–ž•žˆ™‹šG–•›– GGGG›ŒG‰ˆ››Œ™ G—ˆŠ’SG—œš•ŽG™”“ Gœ•›“GˆGŠ“Š’GšGŒˆ™‹U YUGih{{ly€Gyltv}hsVh{{hjotlu{ w™Œ—ˆ™ˆ›–•G—™–™G›–GœšŒ ptwvy{hu{aG~Œ•G•–›Gœš•ŽGˆœ‹–G ˆŠŠŒšš–™ŒšSG’ŒŒ—G›ŒGˆŠŠŒšš–™ G‘ˆŠ’G Š–Œ™G™”“ G—™ŒššŒ‹G•G›šG™ŒŠŒššUG {šGž““G—™ŒŒ•›G›ŒGˆŠŠŒšš–™ š–Š’Œ›G™–”GŠ–™™–𐖕U pG –œGˆ“G›–Gˆ‹Œ™ŒG –œGž““G•ˆ“‹ˆ›Œ –œ™G”ˆ•œˆŠ›œ™Œ™šGžˆ™™ˆ•› U mŽœ™ŒGXUGGh››ˆŠ”Œ•›G›ŒGˆŠŠŒšš–™ GŠ–••ŒŠ›–™ XUG{œ™•G›ŒG›™ˆ•šŠŒŒ™G–U YUGG|š•ŽGˆGŠ–•SG™–›ˆ›ŒG›ŒG‰ˆ››Œ™ GšŠ™ŒžGˆ•›TŠ“–Š’žšŒGYG–™GZG›œ™•šUG GGGGQQl•šœ™ŒG›ˆ›G –œG‹–G•–›G–“‹G›ŒG‰ˆ››Œ™ G—ˆŠ’GžŒ•G GGGGœ•šŠ™Œž•ŽG›ŒG™Œ“ŒˆšŒGšŠ™ŒžH ^ mŽœ™ŒGYU iˆ››Œ™ G™Œ”–ˆ“GVGh››ˆŠ”Œ•› {–G™Œ”–ŒG™–›ˆ›ŒG ›ŒGšŠ™Œž ˆ•›TŠ“–Š’žšŒ ZUG{–Gˆ››ˆŠG›ŒG‰ˆ››Œ™ SG“–Šˆ›ŒG GGGG›ŒG‰–››–”GšŒŠ›–•G–G›ŒG GGGG‰ˆ››Œ™ Gˆ•‹G—™ŒššG›ŒG‰ˆ››Œ™ G GGGGˆŽˆ•š›G›ŒG›™ˆ•šŠŒŒ™SG›Œ•G GGGG™–›ˆ›ŒG›ŒG‰ˆ››Œ™ GšŠ™ŒžG GGGGŠ“–Š’žšŒU XU[Gjvu{yvszGhukGpukpjh{vyz wv~lyGz~p{joV}vs|tlGjvu{yvs w–žŒ™šG›ŒG›™ˆ•šŠŒŒ™G–•Gˆ•‹G–UGh‹‘œš›šG–“œ”ŒG›–G ‹Œš™Œ‹G“ŒŒ“U w|zoG{vG{hsrGz~p{jo o–“‹G‹–ž•G›–G›™ˆ•𔐛SG™Œ“ŒˆšŒG›–G™ŒŠŒŒU |wVkv~uG‰œ››–• zŒ“ŒŠ›G›ŒG‹Œš™Œ‹GŠˆ••Œ“G‰ G—™Œšš•ŽG›ŒG|wVkv~uG‰œ››–•šUG m–™Gˆš›GŠˆ••Œ“GšŒ“ŒŠ›–•G–“‹G‹–ž•G–™G”–™ŒG›ˆ•GXGšŒŠ–•‹U shtwVsvjrG‰œ››–• wXSGwYSGwZSGw[G‰œ››–•š kŒˆ“Œ™G—™–Ž™ˆ””ˆ‰“ŒU GGGGG‰œ››–• kŒˆ“Œ™G—™–Ž™ˆ””ˆ‰“ŒU XU YU ZU [U \U ]U _ tvuG‰œ››–•š kŒˆ“Œ™G—™–Ž™ˆ””ˆ‰“ŒU hu{luuhGjvuulj{vyG j–••ŒŠ›šG›ŒGšœ——“Œ‹G“ŒŸ‰“ŒGˆ•›Œ••ˆG–™Gˆ•G–—›–•ˆ“GŒŸ›Œ™•ˆ“ ˆŒ™ˆ“Gˆ‹ˆ—›–™U ih{{ly€Gwhjr yŒŠˆ™ŽŒˆ‰“ŒG“›œ”T“–•G‰ˆ››Œ™ G—ˆŠ’šUG hjjlzzvy€Gjvuulj{vy {–GŠ–••ŒŠ›Gˆ• Go{_WWGzŒ™ŒšG™ˆ‹–G›–Gˆ•Gl•›Œ“Gˆ——™–Œ‹G ˆœ‹–GˆŠŠŒšš–™ U ^U _U `U XWU mŽœ™ŒGZUGGjvu{yvszGMGpukpjh{vyz ྙGwv~lyGz~p{jo ྚGw{{ ྛG|wVkv~u ྞG ྟGtvu ྜGshtwVsvjr ྠGhu{luuhGjvuulj{vyG ྡGih{{ly€Gwhjr ྡྷGhjjlzzvy€Gjvuulj{vy ྜྷGklhsly GGGGwyvnyhtthisl GGGGOm|uj{pvuP XW johuulsGkpzwsh€ {ŒG–—Œ™ˆ›•ŽGŠˆ••Œ“U h——Œˆ™šGžŒ•G‰“ŒŒ—Gš–œ•‹GšG›œ™•Œ‹G–•U oVsG oG•‹Šˆ›ŒšGŽG—–žŒ™GsG•‹Šˆ›ŒšG“–žG—–žŒ™U zjhu h——Œˆ™šGž…

Text truncated - open the document above for the full version.

Attestation Statements

4 Elstree gate Elstree Way, Borehamwood Hertfordshire WD6 1JD United Kingdom Tel: +44 (0)20 8236 0032 Fax: +44 (0)20 8236 0082 Email: [email protected] www.entel.co.uk Letter of Agency 3 October 2005 TRL Compliance Services Ltd Long Green Forthampton Gloucester GL19 4QH UK To Whom It May Concern: We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Thank you for your attention to these matters. Yours faithfully, Entel UK Limited Full Name Jim Rimington

Cover Letter(s)

4 Elstree gate Elstree Way, Borehamwood Hertfordshire WD6 1JD United Kingdom Tel: +44 (0)20 8236 0032 Fax: +44 (0)20 8236 0082 Email: [email protected] www.entel.co.uk Request for Confidentiality In Accordance with FCC Rule 0.459 03 October 2005 TRL Compliance Services Ltd Long Green Forthampton Gloucester GL19 4QH UK RE: Certification Application FCC ID: RV6HT880 To Whom It May Concern: Please be advised that the following information is to be held confidential on behalf of Entel UK Limited Circuit Diagram Block Diagram Parts List Operational Discription The application contains technical information which Entel UK Limited deems to be trade secrets and propriety. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Yours faithfully, Entel UK Limited Full Name Jim Rimington

External Photos

Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 52 of 55 14. Attachment B – Photos of the EUT • Front View of EUT • Rear View of Product Left View of EUT SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 53 of 55 • Left View of EUT • Right View of EUT SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 54 of 55 • Top View of EUT • Bottom View of EUT SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr

ID Label/Location Info

Entel UK HT 880 FCC ID: RV6HT880 THIS DEVICE COMPLIE S WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE CONDITION THAT THIS DEVICE DEOS NOT CAUSE HARMFUL INTERFERANCE SUBMERSIBLE UHF RADIO

ID Label/Location Info

La bel Afixed Here 12 August 2005 HT780 Label Position

Internal Photos

Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 55 of 55 • Inner View of EUT • Inner View of EUT SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr

RF Exposure Info

SGS TESTING KOREA TEST – REPORT SAR Compliance Test Report Test report no.: STROS-05-010 SAR SGS TESTING KOREA Co., Ltd 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 PHONE +82 31 428 5700 FAX +82 31 427 2371 Report File No. : STROS-05-010 Date of Issue : 11 MAY 2005 Page : 1 of 21 TABLE OF CONTENTS General information 1 Notes 1.1 Testing laboratory 1.2 Details of approval holder 1.3 Manufacturer 1.4 Test item 1.5 Test results 1.6 Test standards 1.7 Technical test 2 Summary of test results 2.1 Test environment 2.2 Test equipment utilized 2.3 Definitions 2.4 Measurement system description 2.5 Test system specification 2.6 Measurement procedure 2.7 Reference positions for handheld radio transmitters 2.8 Measurement uncertainty 2.9 Tissue and system verification 3 Tissue verification 3.1 System verification 3.2 Test Results 4 References 5 Appendix 6 SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROS-05-010 Date of Issue : 11 MAY 2005 Page : 2 of 21 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the SGS Testing Korea. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualification of all persons taking them. Tester: 09.MAY.2005 Elvin Lee Date Name Signature Technical responsibility for area of testing: 10.MAY.2005 James Kwon Date Name Signature SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr 1.2 Location of Testing laboratory SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do Korea Telephone : +82 31 428 5700 Fax : +82 31 427 2371 1.3 Details of approval holder Name Entel UK Ltd. Address 4 Elstree Gate, Elstree Way Borehamwood, Herts. WD6 1JD Country United Kingdom Telephone +44 208 236 0032 Fax +44 208 236 0082 Contact Metin Pallenberg E-Mail [email protected] 1.4 Manufacturer: (if applicable) Name : Street : Town : Country : Report File No. : STROS-05-010 Date of Issue : 11 MAY 2005 Page : 3 of 21 SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr 1.5 Test item FCC ID : RV6HT880 Description of test item : UHF Transceiver Type identification : HT880 Serial number :without; Identical prototype Device category : PCF (Licensed Portable Transmitter Held To Face) Technical data Tx Frequency range : 440 – 470 MHz Rx Frequency range : 440 – 470 MHz Max. Conducted RF output power : 4.0 W Power supply : 7.4 V DC rechargeable battery Antenna Tx : external Antenna Rx : external Antenna type : Whip Antenna Additional information : Tx and Rx. antenna are the same. 1.6 Test Results Max. SAR Measurement : 6.7W/kg (averaged over 1 gram) This EUT has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-200X(Draft 6.5, January 2002). 1.7 Test standards Standards : - IEEE Std. 1528-200X (Draft 6.5, January 2002) FCC Rule Part(s) : -FCC OET Bulletin 65, Supplement C, Edition 01-01 SGS Testing Korea Co., Ltd. Report File No. : STROS-05-010 Date of Issue : 11 MAY 2005 Page : 4 of 21 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr 2 Technical test 2.1 Summary of test results Classification Uncontrolled environment/general population Controlled exposure/occupational environment X Applicable Configuration Handset (Head) Handset (Held to face) X Handset (Body) Headset (Head) Body Worn Equipment X EUT complies with the RF radiation exposure limits of the FCC as shown by the SAR measurement results. These measurements are taken to simulate the RF effects exposure under worst-case conditions. The EUT complies with the requirements in respect to all parameters subject to the test. The test results and statements relate only to the item(s) tested. Please note that the absorption and distribution of electromagnetic energy in the body are very complex phenomena that depend on the mass, shape, and size of the body, the orientation of the body with respect to the field vectors, and the electrical properties of both the body and the environment. Other variables that may play a substantial role in possible biological effects are those that characterize the environment (e.g. ambient temperature, air velocity, relative humidity, and body insulation) and those that characterize the individual (e.g. age, gender, activity level, debilitation, or disease). Because innumerable factors may interact to determine the specific biological ou…

Text truncated - open the document above for the full version.

RF Exposure Info

TRL iss01B Page 1 Memo ENTEL HT 880 SAR Appraisal Criteria The equipment output power level = 4Wmax. The equipment is PTT giving 50% duty factor The equipment will be installed for Occupational Use environment The equipment is for use at > 2.5cms from head I have calculated that the HT 880 radio falls below the low threshold for SAR evaluation and thus does not require SAR evaluation. Paul Harris Telecomms Certification Body TRL Compliance Ltd.

Test Report

Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 1 of 55 TEST REPORT FCC RULES Part 90, Part2 FCC ID : RV6HT880 Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Kind of Product : FM Handheld Transceiver Model Name : HT880 Manufacturer : Entel UK Ltd. Serial No. : - Test Result : Complied The results shown in this report refer only to the sample(s) tested unless otherwise stated. This test report cannot be reproduced, except in full, without prior written permission of company SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 2 of 55 VERIFICATION OF COMPLIANCE Applicant : Entel UK Ltd. Kind of Product : FM Handheld Transceiver Brand Name : Entel Model Name : HT880 Model Difference : - Report File No. : STROR-05-005 Date of test : January 13, 2005 ~ Feb 4, 2005 Receiver EUT : - APPLICABLE STANDARDS STANDARD TEST RESULT FCC RULES Part 90, Part2 Compiled The above equipment was tested by SGS Testing Korea Co., Ltd. for compliance with the requirements set forth in the FCC RULES Part90, Part2. The results of testing in this report apply to the product system that was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Tested By: Date February 10, 2005 Feel Jeong Approved By Date February 10, 2005 James Kwon SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 3 of 55 INDEX CONTENT Page 1. General Description of EUT ----------------------------------------------------------------------- 4 2. General Information of EUT ----------------------------------------------------------------------- 4 3. Test Procedure --------------------------------------------------------------------------------------- 5 Test Results 4. Output Power Conducted------------------------------------------------------------------------- 10 5. Radiated Spurious Emissions--------------------------------------------------------------------- 11 6. Conducted Spurious Emissions------------------------------------------------------------------- 23 7. Audio Frequency Response----------------------------------------------------------------------- 36 8. Audio Low Pass Filter Frequency Response--------------------------------------------------- 37 9. Modulation Limited------------------------------------------------------------------------------- 38 10. Occupied Bandwidth----------------------------------------------------------- ----------------- 40 11. Frequency Stability------------------------------------------------------------- ----------------- 43 12. Transient Frequency Behavior of the Transmitter---------------------------------------- 44 13. Attachment A – Photos of the Test Setup ---------------------------------------------------- 51 14. Attachment B – Photos of the EUT------------------------------------------------------------ 52 SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 4 of 55 1. Description of EUT HT880 has a compact size with various features in range of 440.000~470.000MHz. HT880 has a various features shown as below. The HT880 is constructed with a microprocessor controlled, temperature compensated Phase Locked Loop (PLL)frequency synthesizer. A special integrated circuit provides supports to sub-audible signaling (CTCSS & DCS) and most of the receiving parts are switched off periodically in the power save mode to battery current drain standby. 2. General Information of EUT Transceiver Power Supply DC 7.4V (lithium type of battery) Operating Frequency 440.000MHz ~470.000MHz Transmit Power 1W(low)/4W(high) Modulation of Channels FM Channel spacing 12.5kHz and 25kHz Emission 8K5F3E/ 16K0F3E Communication method Simplex Number of Channels 128 channels Antenna Type External SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 5 of 55 3. Test Procedure The test procedure are performed following the test stands ANSI/EIA-603, if applicable. 3.1 Output Power Conducted FCC 2.1046(a),FCC 90.205 The conducted RF output power is the available power at the output terminals of the transmitter when the output terminals are corrected to the standard transmitter load. The test sample is feeding a 50 ohm coaxial attenuator which is connected to a spectrum analyzer. The power output at the transmitter antenna port is determined by adding the value of the attenuator to the spectrum analyzer reading. The test are performed at the frequencies(low, middle, high channels of the EUT operating band)and full rated power levels of the transmitter. 3.2 Radiated Spurious Emissions FCC 2.1053, FCC 90.210 Radiated spurious emissions are emissions from the EUT when transmitting in non-radiating load on frequencies outside the operating band. ERP measurement of spurious emission the general substitution method as described at 2.4.2. In order to suppress intermodulation products in the spectrum analyzer a notch filter is used, if applicable . SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 6 of 55 3.3 Conducted Spurious Emissions FCC 2.1051 Conducted spurious emissions are emissions at the antenna terminal on frequencies outside the oper…

Text truncated - open the document above for the full version.

Test Setup Photos

Report File No. : STROR-05-005 Date of Issue : February 10, 2005 Page : 51 of 55 13.Attachment A – Photos of the test setup SGS Testing Korea Co., Ltd. 18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea, 435-041 Tel. +82 31 428 5700 / Fax. +82 31 427 2371 http://www.sgstesting.co.kr

Contact Information

Applicant

Metin Pallenberg(Managing Director)
[email protected]+44 2082360032Fax: +44 2082360082

Technical Contact

ENTEL UK LimitedJim Rimington
[email protected]+442082360032

4 Elstree Gate · Boreham Wood, ESSEX · United Kingdom

Test Firm

SGS Korea Co., Ltd.Elan Lee
[email protected]82-31-428-5702Fax: 82-31-427-2370

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
290.21440 MHz - 470 MHz4 W16K0F3E2.5 ppm
Confidentiality
Long Term
Grant Notes
Channel spacing 12.5KHz and 25KHz Output Power 1W(low) and 4W(high) Power listed is Conducted. This device must be restricted to work related operations in an Occupational Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements contained in the equipment user manual. The highest reported SAR values at 50% duty factor are: head - 2.97 W/kg: body-worn - 6.70 W/kg.

Other Applications from Entel UK Limited

Hand held marine radio - FCC ID RV6HT840 - Entel UK Limited
RV6HT840

Hand held marine radio

Mar 02, 2006

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
FM Handheld Submersible Transceiver HT780 - FCC ID RV6HT780 - Entel UK Limited
RV6HT780

FM Handheld Submersible Transceiver HT780

Sep 08, 2005

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face
VHF marine transceiver - FCC ID RV6HT640 - Entel UK Limited
RV6HT640

VHF marine transceiver

Jun 08, 2004

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face