Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: โ Reorient or relocate the receiving antenna. โ Increase the separation between the equipment and receiver. โ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. โ Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Date: 04/17/2018 VCB_F-01: Operating Procedures Form โ FCC Confidentiality v03 Page 1 of 1 ChoisTechnology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: RVBXPG300YN Pursuant to Sections 0.457 and 0.459 of the Commissionโs Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Type of Confidentiality Requested Exhibit Type โShort Term โPermanent Block Diagrams โShort Term External Photos โShort Term โPermanent* Internal Photos โShort Term โPermanent Operation Description โShort Term โPermanent Parts List/BOM โ Short Term โPermanent Schematics โShort Term Test Setup Photos โShort Term โPermanent* User manual *Requires further justification before permanent confidentiality will be allowed. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: Pursuant to DA04-1705 June 15, 2004 of the Commissionโs public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for an initial period of 180 days. Sincerely, Clientโs signature: Clientโs name & title: Oh Gwanseok / Staff Contact information / address: : +82-70-5121-2134/ S-1404, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, 21984, South Korea
Date: 04/17/2018 VCB_F-01: Operating Procedures Form โ FCC Authorization v02 Page 1 of 1 ChoisTechnology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2022-11-14 SUBJECT: FCC Application for (FCC ID: RVBXPG300YN) To Whom It May Concern: We, the undersigned, hereby authorize David Zhang in Vista Laboratories, Inc. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Vista Laboratories, Inc. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, (Must be signed by the person that is listed on the FCC Website) Clientโs signature: Clientโs name & title: Oh Gwanseok / Staff Contact information / address: +82-70-5121-2134/ S-1404, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, 21984, South Korea
FCC ID: RVBXPG300YN Page 1 of 4 Upper Lower FCC ID: RVBXPG300YN Page 2 of 4 Side 1 Side 2 FCC ID: RVBXPG300YN Page 3 of 4 Side 3 Side 4 FCC ID: RVBXPG300YN Page 4 of 4 Ant โก
FCC ID: RVBXPG300YN Copyright โธ 2022, KRL Co., Ltd. SAMPLE LABEL & LOCATION ChoisTechnology Co., Ltd. M/N: X-POINTER FCC ID: RVBXPG300YN
FCC ID: RVBXPG300YN Page 1 of 1 Main Board Main Board
FCC ID: RVBXPG300YN * SAR evaluation - Min. transmitting frequency = 2402 MHz - Min. test separation distance = 5 mm -Max. Power with tune-up tolerance = 2.04 dBm = 1.6 mW (Measured Maximum power = 1.54 dBm ยฑ 0.5dB) Step 1) SAR Test exclusion thresholds for 100MHz to 6GHz at test separation distance โค 50 mm = Used [(max.power of channel, including tune-up torelance, mW)/(min. test separation distance, mm)] * [โf(GHz)] = [ 1.6 / 5 ] * [ โ 2.402 ] = 0.496 โค 3, for 1g SAR Thus, SAR for this device is not required. Step 2) SAR Test exclusion thresholds for 100MHz to 1500MHz at test separation distance > 50 mm = N/A [Threshold at 50mm in step 1) + (test separation distance - 50 mm) * (โf(MHz)/150] mW Step 3) SAR Test exclusion thresholds for 1500MHz to 6GHz at test separation distance > 50 mm = N/A [Threshold at 50mm in step 1) + (test separation distance - 50 mm) * 10] mW
R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 1 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. Test Report 1. Client แName : Chois Technology Co., Ltd. แAddress : S-1404, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, South Korea 2. Use of Report : FCC Approval 3. Sample Description แProduct Name : X-POINTER แModel Name : XPG300YN 4. Date of Receipt : 2022-10-12 5. Date of Test : 2022-10-31 ~ 2022-11-03 6. Test Method : FCC Part 15 Subpart C 15.247 7. Test Results : Refer to the test results This test report must not be reproduced or reproduced in any way. The results shown in this test report are the results of testing the samples provided. This test report is prepared according to the requirements of ISO / IEC 17025. Affirmation Tested by Yong-Min, Won (signature) Technical Manager Jong-Myoung, Shin (signature) Nov 21, 2022 EMC Labs Co., Ltd. (seal) R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 2 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. Contents 1. Applicant & Manufacturer & Test Laboratory Informationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 2. Equipment under Test(EUT) Informationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 3. Test Summaryยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 4. Used equipment on testยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 5. Antenna Requirementยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 6. 6 dB Bandwidthยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 7. Maximum Peak Output Powerยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 8. Peak Power Spectral Densityยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 9. TX Radiated Spurious Emission and Conducted Spurious Emissionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 10. Conducted Emissionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 33 APPENDIX APPENDIX I TEST SETUPยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 36 APPENDIX II UNCERTAINTYยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 38 R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 3 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. Version TEST REPORT NO. DATE DESCRIPTION KR0140-RF2211-002 Nov 03, 2022 Initial Issue KR0140-RF2211-002-R1 Nov 21, 2022 Modified the typo in DCF Calculation for Radiated Spurious Emission R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 4 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. 1. Applicant & Manufacturer & Test Laboratory Information 1.1 Applicant Information Applicant Chois Technology Co., Ltd. Applicant Address S-1404, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, South Korea Contact Person Daeheung, Son Telephone No. +82-70-5118-5568 Fax No. +82-32-246-3406 E-mail [email protected] 1.2. Manufacturer Information Manufacturer Chois Technology Co., Ltd. Manufacturer Address S-1404, 32, Songdogwahak-ro, Yeonsu-gu, Incheon, South Korea 1.3 Test Laboratory Information Laboratory EMC Labs Co., Ltd. Laboratory Address 100, Jangjateo-ro, Hobeop-myeon, Icheon-si, Gyeonggi-do, Republic of Korea Contact Person Yong-Min, Won Telephone No. +82-31-637-8895 Fax No. +82-505-116-8895 FCC Designation No. KR0140 FCC Registration No. 58000 R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 5 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. 2. Equipment under Test(EUT) Information 2.1 General Information Product Name X-POINTER Model Name XPG300YN FCC ID RVBXPG300YN Power Supply DC 3.7 V 2.2 Additional Information Operating Frequency 2 402 MHz ~ 2 480 MHz Number of channel 40 Modulation Type GFSK Antenna Type PCB Pattern Antenna Antenna Gain -2.26 dBi Firmware Version 1.0 Hardware Version 1.0 Test software nRF_DTM v2.4.0 2.3 Test Frequency Test mode Test Frequency (MHz) Low Frequency Middle Frequency High Frequency BLE 2 402 2 442 2 480 2.4 Used Test Software Setting Value Test Mode Setting Item Power BLE -16 2.5 Mode of operation during the test - The EUT continuous transmission mode during the test with set at Low Channel, Middle Channel, and High Channel. To get a maximum radiated emission levels from the EUT, the EUT was moved throughout the XY, YZ, XZ planes. 2.6 Modifications of EUT - None R Report No.: KR0140-RF2211-002-R1 EMCLabs-QPF-26-25 [Enactment_00 / 2022. 09. 07] Page 6 / 39 This test report shall not be reproduced except in full, Without the written approval. ๋ณธ ์ํ์ฑ์ ์๋ (แแ ฎ)ABCD์ ์๋ฉด ๋์ ์์ด ๋ฌด๋จ ์ ์ ๋ฐ ๋ณต์ฌ๋ฅผ ํ ์ ์์ต๋๋ค. 3. Test Summary Applied FCC Rule IC Rule Test Items Test Condition Result 15.203 - Antenna Requirement Conducted C 15.247(a) RSS-247 (5.2) 6 dB Bandwidth C - RSS GEN (6.7) Occupied Bandwidth (99%) C 15.247(b) RSS-247 (5.4) Maximum Peak Output Power C 15.247(e) RSS-247 (5.2) Peak Power Spectral Density C 15.247(d) RSS-247 (5.5) Conducted Spurious Emission C 15.247(d) 15.205 & 15.209 RSS-247 (5.5) RSS-GEN (8.9 & 8.10) Radiated Spurious Emission Radiated C 15.207 RSS-GEN (8.8) Conducted Emissions AC Line Conducted C Note 1: C=Complies NC=Not Complies NT=Not Tested NA=Not Applicable The sample was tested according to the following specification: ANSI C63.10:2013. Compliance was determined by specification limits of the applicable standard according to customer requirements. R Report No.: KR0140-RF22โฆ
Text truncated - open the document above for the full version.
Below 30 MHz Below 1 GHz Above 1 GHz Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.43 mW |
Thermosafer
Equipment Class
DTS - Digital Transmission SystemX-pointer
Equipment Class
DTS - Digital Transmission System
X-POINTER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
X-POINTER
Equipment Class
DTS - Digital Transmission System
X-POINTER
Equipment Class
DTS - Digital Transmission System