Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SAGEM RT1000-V2 Fixed GSM Phone SAGEM RT1000 User Manual _________ 2 User Manual Reference : 251 872 337 March 23, 2005 Issue SAGEM RT1000 User Manual _________ 3 © by SAGEM SA, 2005 All trade marks and product names are trade marks, registered trade marks or product names of the respective title holders. The contents of this manual and technical specifications can be changed without notice. The description of specifications in this manual does not constitute a contract. SAGEM RT1000 User Manual _________ 4 Safety Notes ! General: Please read this manual carefully before using the device. The device is for indoor use only. Keep the device out of the reach of children, especially infants. Do not expose the device to moisture, splashes, drips or spray. To avoid the risk of demagnetisation please do not store diskettes, credit cards or similar objects in the vicinity of the device. Purpose: The sole purpose of the device is to make telephone calls through the GSM radio networks. Use of this device for any other purpose is prohibited and can be dangerous. Installation: Do not switch on the device if any cable or the device itself is damaged. Never use the device in areas where radio transmission is prohibited. Health: The device contains a radio transmitter which may affect the operation of medical electronic devices such as hearing aids or heart pacemakers. Your doctor and the manufacturer of such devices can provide you with further advice. SIM card: Please turn-off the device before you enter or remove the SIM card. Power supply: Only use the manufacturer's original power supply units. Take care that the Power Supply is always easily accessible. The voltage specified on the rating plate of the power supply unit must match that of your mains supply. Disconnect the mains plugs of all devices during thunderstorms. Battery: The device is equipped with a rechargeable or non-rechargeable battery. The battery only serves for short-term bridging of power failures. In case of changing the battery being installed in the device please take notice of the following: To exchange the rechargeable or non-rechargeable battery you need to remove the battery cover. Before removing the battery cover, please make sure to unplug the charger or plug-in power supply. After the installation of the battery, close the cover again in the right position. Caution! Danger of explosion during inappropriate replacement of the battery! The battery must not be short-circuited. If the device is removed from service or during works on it, all connections of the battery are to be disconnected. When replacing the battery, do not dispose of it in the household refuse, but dispose of it properly, in accordance with the local facilities and regulations. !IMPORTANT USER INFORMATION FCC Part 15 This equipment with the delivered antenna has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer / installer or an experienced radio/TV technician for help. FCC part 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC part 15.21 Modifications not expressly approved by SAGEM could void the user's authority to operate the equipment. RF Exposure mobile Keep distance ! Typically, the antenna connected to the transmitter is an omni- directional antenna with max. 3dBi gain. Using this antenna the total composite power in PCS mode is smaller than 1 watt ERP. The internal / external antennas used for this transmitter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter." SAGEM RT1000 User Manual _________ 6 Contents 1PREFACE9 2TECHNICAL CHARACTERISTICS10 3HOUSING13 3.1HOUSING VIEWS13 3.2KEYS DESCRIPTION16 3.3LEDS DESCRIPTION18 3.4SIM CARD SOCKET18 3.5POWER CONNECTOR AND SWITCH18 4ICONS OF THE SCREEN20 5FIRST USE OF THE PHONE22 5.1CHECKING OF THE PACKAGE22 5.2INSTALLATION OF THE BATTERY22 5.3INSTALLATION OF THE SIM CARD23 5.4ANTENNA23 5.5POWER ON THE PHONE23 5.6POWER24 6MAIN FUNCTIONS OF THE SAGEM RT100026 6.1INITIALIZATION OF THE PHONE26 6.2OUTGOING CALLS27 6.3INCOMING CALLS28 6.4SWITCHING BETWEEN HANDSET MODE AND HAND-FREE MODE28 6.5END OF A CALL28 6.6ADJUST VOLUME29 6.7EMERGENCY SERVICE29 6.8INTERNATIONAL CALL29 6.9USE THE PHONE BOOK TO DIAL29 6.10SPEED DIAL29 6.11CALL HOLD, CALL WAITING, MULTI-PARTY CALL29 7CONFIGURATION MENU31 7.1PHONE BOOK31 7.1.1Read Phonebook32 7.1.2Add Contact32 7.1.3Status32 7.1.4Speed dial32 SAGEM RT1000 User Manual _________ 7 7.1.5Delete all33 7.1.6Fixed numbers33 7.2MESSAGES (SMS)33 7.2.1Receiving a Message33 7.2.2Read Message34 7.2.3New Message34 7.2.4Service Center35 7.2.5Delete all35 7.3CALL HISTORY35 7.3.1Dialed36 7.3.2Missed36 7.3.3Received36 7.3.4Return36 7.4PHONE SETTINGS36 7.4.1Contrast37 7.4.2Ring Type37 7.4.3Volume37 7.4.4Set Time37 7.4.5I…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 1 of 19 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 2 of 19
Version: Date: Written by: 1.0 24.3.2005 PAU Location FCC Label SAGEM RT1000 Fixed GSM Phone Dr. Neuhaus Telekommunikation GmbH Doc.-No. : 8136PA010 8136PA010.doc Page 1/1
Version: Date: Written by: 1.0 9.4.2005 PAU FCC ID Label Sample SAGEM RT1000 GSM Gateway Dr. Neuhaus Telekommunikation GmbH Doc.-No. : 8136LB010 8136lb010.doc Page 1/1 FCC ID: RZV8136
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 3 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 4 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 5 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 6 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 7 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 8 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 9 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 10 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 11 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 12 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 13 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 14 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 15 of 19
B 比威通信 BEWEI BWT-1900G CH1 START 1 700 000 000.Hz STOP 2 000 000 000.Hz CH1 A/R SWR MKR 1 : 1.253 U REF 1.000 U 1.000 U/ 1 750 000 000.Hz MARKER 1 1 750 000 000.Hz 1.253 U Cor 1 2 MARKER 2 1 960 000 000.Hz 1.406U [ 803 ] 单位:m m 电性能指标 ELECTRICAL SPECIFICATIONS 机械性能 MECHANICAL SPECIFICATIONS 产品名称 Product Type 活动直拐高增益天线 型号 Model Type BWT-1900 G 频率范围 Frequency 输入阻抗 Impedance 驻波比 VSWR 增益 Gain 方向性 Radiation 最大功率 Max power 极化 Polarization Range 1750-1960MHz 1:1.5 3.0dB 垂直 全向 20 W 50V 最小直径 Min diameter 最大直径 Max Diameter 高度 Height 型号 Model Type 产品名称 Product Type 接口 ConnectorSMA或TNC或按客户要求 165.0mm ?12.0mm ?9.0mm BWT-1900G 活动直拐高增益天线 雷电保护Lighting protection 直流接地 广州市花都区比威通信天线厂 地址:中国 广州市花都区新华镇三华村同福新村 电话/传真:86-020-86875939
Version: Date: Written by: 1.0 27.4.2005 PAU Tuning Procedure SAGEM RT1000V2 GSM Gateway Dr. Neuhaus Telekommunikation GmbH Doc.-No. : 8126PA011 8126PA010.doc Page 1/1 A tuning procedure is not applicable to the SAGEM RT1000V2.
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT SAR Compliance Test Report Test report no.: G0M20501-9196-S-1 SAR ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-S-1 Page 1 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Manufacturer 1.5 Application details 1.6 Test item 1.7 Test results 1.8 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 Definitions 2.5 Measurement system description 2.6 Test system specification 2.7 Measurement procedure 2.8 Reference points 2.9 Test positions 2.10 Measurement uncertainty 3 Tissue and system verification 3.1 Tissue verification 3.2 System verification 4 Test Results 5 References 6 Appendix ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-S-1 Page 2 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualification of all persons taking them. Tester: 04.02.2005 Date ETS-Lab. Name Signature Technical responsibility for area of testing: 04.02.2005 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-S-1 Page 3 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telephone : +49 33631 888 00 Fax : +49 33631 888 660 1.2.2 Details of accreditation status ACCREDITED TESTING LABORATORY DAR- REGISTRATION NUMBER: TTI-P-G 126/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) A CCREDITED BY BLUETOOTH QUALIFICATION REVIEW BOARD INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number 1983-01 1.3 Details of approval holder Name : SAGEM SA Network Devision Street : 27, rue Leblanc Town : 75512 Paris Cedex 15 Country : France Telephone : +33 1 4070 6315 Fax : +33 1 5323 1868 Contact : Mr. Michel Stutzmann E-Mail : [email protected] 1.4 Manufacturer: (if applicable) Name : Street : Town : Country : ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-S-1 Page 4 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.5 Application details Date of receipt of application : 12.01.2005 Date of receipt of test item : 12.01.2005 Date of test : 31.01.-01.02.2005 1.6 Test item FCC ID : RZV8136 Description of test item : Fixed GSM Phone Type identification : Sagem RT1000 V2 Serial number : without; Identical prototype Device category : PCB (Licensed Base Station) Technical data TX Frequency range : 1850,2 - 1909,8 MHz RX Frequency range : 1930,2 - 1989,8 MHz Max. Conducted RF output power : PCS 1900 / 30,4 dBm (1096,48 mW) Power supply : 120 V AC AC/DC adaptor Antenna Tx : external Antenna RX : external Additional information : Tx and Rx. antenna are the same. 1.7 Test Results Max. SAR Measurement : 0,219 W/kg (averaged over 1 gram) This EUT has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-2003, December 2003. ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-S-1 Page 5 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.8 Test standards Standards : - IEEE Std. 1528-2003, December 2003 FCC Rule Part(s) : - FCC OET Bulletin 65, Supplement C, Edition 01-01 2 Technical test 2.1 Summary of test results Applicable Configuration Handset (Head) Handset (Body) X Headset (Head) Body Worn Equipment EUT complies with the RF radiation exposure limits of the FCC as shown by the SAR measurement results. These measurements are taken to simulate the RF effects exposure under worst-case conditions. The EUT complies with the requirements in respect to all parameters subject to the test. The test results and statements relate only to the item(s) tested. Please note that the absorption and distribution of electromagnetic energy in the body are very complex phenomena that depend on the mass, shape, and size of the body, the orientation of the body with respect to the field vectors, and the electrical properties of both the body and the environment. Other variables that may play a substantial role in possible biological effects are those that characterize the environment (e.g. ambient temperature, air velocity, relative humidity, and body insulation) and those that characterize the i…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 24 Test report no.: G0M20501-9196-P-24 FCC ID: RZV8136 Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 66 ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 1 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 3 Test Results 4 RF Power Output, FCC 2.1046 4.1 Test Procedure 4.2 Test Results 5 Radiated Power, FCC 24.232 5.1 Test Procedure 5.2 Test Results 6 Occupied Bandwidth, FCC 2.1049 6.1 Test Procedure 6.2 Test Results 7 Field Strength of Spurious Radiations, FCC 2.1053, 24.238 7.1 Test Procedure 7.2 Test Results 8 Line Conducted Emissions, FCC 15.207 8.1 Test Procedure 8.2 Test Results 9 Frequency Stability vs Temperature, FCC 2.1055, 24.235 9.1 Test Procedure 9.2 Test Results 10 Frequency Stability vs Voltage, FCC 2.1055, 24.235 10.1 Test Procedure 10.2 Test Equipment ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 2 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 31.01.2005 Date ETS-Lab. Name Signature Technical responsibility for area of testing: 31.01.2005 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 3 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 660 1.2.2 Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY: BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number: 1983-01 1.3 Details of approval holder Name : SAGEM SA Network Devision Street : 27, rue Leblanc Town : 75512 Paris Cedex 15 Country : France Telephone : +33 1 4070 6315 Fax : +33 1 5323 1868 Contact : Mr. Michel Stutzmann Email : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 4 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 12.01.2005 Date of receipt of test item : 12.01.2005 Date of test : 12.01.2005 – 26.01.2005 1.5 Test item Description of test item : Fixed GSM Phone Type identification : Sagem RT1000 V2 Serial number : Test model without serial number. Photos : See annex A Technical data Frequency range Tx : 1850.2 - 1909.8 MHz Frequency range Rx : 1930.2 – 1989.8 MHz Antenna transmitter : external antenna Antenna Gain : 3.0 dBi Power supply : 6.5 V DC 120 V AC/DC Adaptor Operating mode : duplex Type of modulation : GMSK (GSM modulation) Emission : GXW Manufacturer: (if applicable) Name : Street : Town : Country : Additional information : none ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 5 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC Part 24 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 23 o C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa Extreme temperature : -30 / 50 °C ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 6 of 30 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment utilized No. Test equipment Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlöder ETS 0002 Test receiver ESVP Rohde & Schwarz ETS 0003 Diode power sensor NRV-Z2 Rohde & Schwarz ETS 0004 Spectrum and network analyzer FSMS 26 Rohde & Schwarz ETS 0005 Test receiver SMV 11 MEB ETS 0006 Test receiver system SME 12 MEB ETS 0007 Horn antenna AT 4004 ar ETS 0008 Antenna Loop antenna Siemens ETS 0009 Antenna ARA 2 MEB ETS 0010 Antenna Loop antenna MEB ETS 0011 Antenna van Veen/ Frame Rohde & Schwarz ETS 0012 Antenna HK 116 Rohde & Schwarz ETS 0013 Antenna HL 223 Rohde & Schwarz ETS 0014 Antenna HL 025 Rohde & Schwarz ETS 0015 Antenna HL 025 Rohde & Schwarz ETS 0016 Precision antenna kit VHAP Schwarzbeck ETS 0017 Precision antenna kit UHAP Schwarzbeck ETS 0018 Horn antenna BBHA 9120 D Schwarzbeck ETS 0019 Horn antenna BBHA 9120 D Schwarzbeck ETS 0020 Antenna DP 21 MEB ETS 0021 Antenna DP …
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 16 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 17 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 18 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20501-9196-P-24 Page 19 of 19
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.85 GHz - 1.91 GHz | 1.09 W | 250KGXW | 38.0000000000 Hz |

GSM/GPRS Network Termination
Equipment Class
PCB - PCS Licensed Transmitter