S491011SSR03Work Area Monitor

GroundProbe Pty Ltd
Work Area Monitor - FCC ID S491011SSR03 - GroundProbe Pty Ltd
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Nov 28, 2011
Application Purpose
Original Equipment
Date of Application
Nov 27, 2011
Equipment Note
Work Area Monitor
Frequency Range
9552.50000000 - 9552.50000000
Company
GroundProbe Pty Ltd
Country
Australia

Documents & Files

Select a file to view

Attestation Statements

↗
↗

External Photos

↗
↗
↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

WAM Antenna Photos 200dpi_part1.doc Commercial in Confidence Photographs of WAM Radar Antenna WAM Antenna Photos 200dpi_part1.doc Commercial in Confidence WAM Antenna Photos 200dpi_part1.doc Commercial in Confidence WAM Antenna Photos 200dpi_part1.doc Commercial in Confidence WAM Antenna Photos 200dpi_part1.doc Commercial in Confidence

External Photos

WAM Antenna Photos 200dpi_part2.doc Commercial in Confidence Photographs of WAM Radar Antenna WAM Antenna Photos 200dpi_part2.doc Commercial in Confidence

External Photos

WAM Antenna Photos 200dpi_part3.doc Commercial in Confidence Photographs of WAM Radar Antenna WAM Antenna Photos 200dpi_part3.doc Commercial in Confidence WAM Antenna Photos 200dpi_part3.doc Commercial in Confidence WAM Antenna Photos 200dpi_part3.doc Commercial in Confidence

ID Label/Location Info

FCC ID Label Format and Label Location GP WAM FCC ID Label Fomat & Label Location - Rev 1.doc Sticker Details Manufacturer : Brady Part Number : PTL-31-486 Dimension : h25.4 x w38.1mm Sticker Type : Permanent Metallized Polyester Temperature Rating : Max 120 o C / 30 Days FCC ID: S491011SSR03 This device complies with Part 90 of the FCC Rules FCC ID Label – Fitted to antenna positioner

Test Report

Page 1 of 40 EMC Technologies Pty Ltd reports apply only to the specific samples tested under stated test conditions. It is the manufacturer’s responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. EMC Technologies Pty Ltd shall have no liability for any deductions, inferences or generalisations drawn by the client or others from EMC Technologies Pty Ltd issued reports. This report shall not be used to claim, constitute or imply product endorsement by EMC Technologies Pty Ltd. Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or measurement included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall only be reproduced in full, with the exception of the certificate on p3 EMC Technologies Pty Ltd ABN 82 057 105 549 176 Harrick Road Keilor Park Victoria Australia 3042 Ph: + 613 9365 1000 Fax: + 613 9331 7455 email: [email protected] EMI TEST REPORT for CERTIFICATION to FCC PART 90 FCC ID: S491011SSR03 Test Sample: Work Area Monitor Model: WAM Tested for: GroundProbe Pty Ltd Report Number: M110920R2_Cert_Tx Issue Date: 16 th November 2011 FCC ID: S491011SSR03 Report No. M110920R2_Cert_Tx Page 2 of 40 Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or measurement included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall only be reproduced in full, with the exception of the certificate on p3 EMI TEST REPORT FOR CERTIFICATION to FCC Part 90 EMC Technologies Report No. M110920R2_Cert_Tx Issue Date: 16 th November 2011 CONTENTS 1.0 INTRODUCTION 2.0 GENERAL INFORMATION 3.0 RF MEASURMENTS 3.1 Power Output, Section 2.1046 3.2 Modulation Characteristic, Section 2.1047 3.3 Occupied Bandwidth, Section 2.1049 3.4 Conducted Spurious Emissions, Section 2.1051 3.5 Frequency Stability, Section 2.1055 4.0 RADIATED SPURIOUS EMISSION MEASUREMENTS 4.1 Test Procedure 4.2 Field Strength Calculation 4.3 Relation between field-strength and E.I.R.P. 4.4 Radiated Spurious, Section 2.1053 5.0 COMPLIANCE STATEMENT 6.0 MEASUREMENT UNCERTAINTY APPENDIX A MEASUREMENT INSTRUMENT APPENDIX B CONDUCTED SPURIOUS GRAPHS APPENDIX C RADIATED SPURIOUS GRAPHS FCC ID: S491011SSR03 Report No. M110920R2_Cert_Tx Page 3 of 40 Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or measurement included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall only be reproduced in full, with the exception of the certificate on p3 EMI TEST REPORT FOR CERTIFICATION to FCC PART 90 Report Number: Report M110920R2_Cert_Tx Test Sample: Work Area Monitor Model Number: WAM FCC ID: S491011SSR03 Equipment Type: Intentional Radiator Manufacturer/ Tested for: GroundProbe Pty Ltd Address: 8 Hockings Street South Brisbane QLD 4101 Australia Phone: (617) 3010 8999 Fax: (617) 3010 8988 Responsible Party: Benny Chen – [email protected] Test Standards: FCC Part 90 - Private Land Mobile Services ANSI/TIA-603-C Test Dates: 20 th to 29 th September 2011 Test Engineer: Chieu Huynh Attestation: I hereby certify that the device(s) described herein were tested as described in this report and that the data included is that which was obtained during such testing. Authorised Signatory: Chieu Huynh Senior EMC Engineer EMC Technologies Pty Ltd Issued by EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au FCC ID: S491011SSR03 Report No. M110920R2_Cert_Tx Page 4 of 40 Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or measurement included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall only be reproduced in full, with the exception of the certificate on p3 EMI TEST REPORT FOR CERTIFICATION to FCC PART 90 1.0 INTRODUCTION This report details the results of RF tests and measurements performed on the Work Area Monitor, model: WAM. Test results were obtained using procedures in accordance with the following Federal Communications Commission (FCC) standards/regulations: The test sample complied with the requirements of FCC Part 90 - Private Land Mobile Services. 1.1 Summary of Results FCC Part 90 Test Performed Result 2.1046 Power Output Noted 2.1047 Modulation Complied 2.1049 Bandwidth Complied 2.1051 Conducted Spurious Complied 2.1053 Radiated Spurious Complied 2.1055 Frequency Stability Complied 2.1057 Frequency Range Noted The measurement procedure used was in accordance with ANSI/TIA-603-C. 1.2 EUT – Voltage Power Conditions Measurements were performed at a voltage of 12 VDC batteries. 1.3 Modifications A ferrite was installed on the Ethernet cable inside a Camera box. FCC ID: S491011SSR03 Report No. M110920R2_Cert_Tx Page 5 of 40 Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or measurement included in this document are traceable to Australian/national standards. NATA is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the equivalence of testing, calibration and inspection reports. This document shall only be reproduced in full, with the exception of the certificate on p3 2.0 GENERAL INFORMATION 2.1 Test Samp…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: S491011SSR03 ______________________________________________________________________ EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au TEST SETUP PHOTOS Radiated Emissions below 30 MHz Radiated Emissions below 1 GHz FCC ID: S491011SSR03 ______________________________________________________________________ EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au TEST SETUP PHOTOS Radiated Emissions below 18 GHz FCC ID: S491011SSR03 ______________________________________________________________________ EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au TEST SETUP PHOTOS Radiated Emissions above 18 GHz FCC ID: S491011SSR03 ______________________________________________________________________ EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au TEST SETUP PHOTOS Conducted Spurious at Antenna Port WAM in Temperature Chamber FCC ID: S491011SSR03 ______________________________________________________________________ EMC Technologies Pty. Ltd., 176 Harrick Road, Keilor Park, VIC, 3042, Australia. Phone: +61 3 9365 1000 Fax: +61 3 9331 7455 www.emctech.com.au TEST SETUP PHOTOS

Contact Information

Applicant

David Noon(VP Marketing & Technology)
[email protected]61 7 3010 8944Fax: 61 7 3010 8988

Test Firm

EMC Technologies Pty. Ltd.Michael Evans
[email protected]617-3875-2455Fax: 617-3875-2466

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1909.55 GHz - 9.55 GHz30.00 mW101MP0N0E-10 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be fixed-mounted on outdoor environment. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3).

Other Applications from GroundProbe Pty Ltd

Slope Stability Radar Module - FCC ID S491225S5SSRXT - GroundProbe Pty Ltd
S491225S5SSRXT

Slope Stability Radar Module

Aug 19, 2026

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Slope Stability Radar - FCC ID S490806SSR02 - GroundProbe Pty Ltd
S490806SSR02

Slope Stability Radar

Nov 05, 2006

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter