Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operation Instruction SPECIFICATION Remote Control Outlet Model: RCS-13U+RC-13U Voltage: 125VAC, 60Hz Max.load: 15A Resistive or General purpose, 10A/1250W Tungsten, TV-5, 1/2HP Remote battery: 1PC CR2032 3V Radio frequency: 433.92MHz Transmitter duty cycle<10% Receiver category: Class 3 Operation distance:about 80 feet in open area DIAGRAM OPERATION 1.Put battery in the transmitter. Open battery cover of the transmitter and put 1PC CR2032 3V battery in it.Then press ON or OFF button of the transmitter once to check whether it can work. If LED indicator turns on, it means this transmitter works well. 2.Plug the receiver into an outlet. This receiver is a “grounded” device. It is only intended for use with a three-pronged grounded outlet. 3.Pairing with transmitter a.Once the receiver is plugged into the receptacle. LED indicator in the front right corner of the receiver is slowly flash. Enter into leaning mode. Please note: The receiver will exit leaning mode after 29 seconds without any operation. Then please pull the receiver out and put it into the outlet again to pair. b.Press ON button of the transmitter once to pair with the receiver. Once successfully, LED indicator of the receiver stops flash and keeps on. c.Now you can turn the receiver on/off by pressing button of the transmitter. LED indicator of the receiver turns on, it means power is on. In contrast, power is off. 4.Clear the pairing 1.Pull receiver out and put it into the outlet again (LED indicator is slowly flash as learning mode). 2.Press OFF button of the transmitter, then LED indicator of receiver flashes quickly (3-4 seconds), which means pairing is cleared. After that, receiver returns to learning mode. Total time is 29 seconds. 3.Unplug the receiver. 4.The receiver should now be unpaired with the remote HELPFUL TIPS 1.The transmitted coded pattern is random/learning code. Repeat probability is 1/1,048,575. 2.One receiver can memorize maximum 10 different transmitters. If pair the eleventh transmitter, the first paired transmitter will be cleared. 3.One transmitter can pair multiple different receivers and turn them on/off simultaneously. WARNINGS Risk of Electric Shock - Keep children away. - Do not use in wet locations. - Do not plug two or more timers together. - Always ensure the plug of any appliance is fully inserted into the timer outlet. - If cleaning of the timer is required, remove from mains power and wipe timer with a dry cloth. - Do not immerse timer in water or any other liquid. - For indoor use only. Risk of Fire - Don't plug in an appliance where the load exceeds rated capacity. - Do not use with extension cords. - Do not use to control appliances that contain heating elements (cooking appliances, heaters, irons, etc.). AVERTISSEMENT Risque de choc électrique - Gardez les enfants à l’écart. - N’utilisez pas l’article dans des endroits humides. - Ne pas ficher a deux minuteries ou plus ensemble. - Toujours faites attention que la prise de tout appareil est entièrement insérée dans la prise de la minuterie. - Si le nettoyage de la minuterie est exigé, retirez la minuterie du pouvoir secteur et l’essuyez avec un chiffon sec. - Ne pas plonger la minuterie dans l’eau ou dans tout autre liquide. - Pour usage à l’intérieur seulement. Risque d’incendie - Ne branchez pas un appareil où la charge dépasse capacités électriques. - Ne pas utiliser avec des rallonges électriques. - N’utilisez pas cet article pour commander des appareils qui contiennent des éléments chauffants (appareils de cuisson, radiateurs, fers, etc.). CAUTION: Do not install/operate this product unless it could be wired with minimum 15Amp circuit breaker. Ne pas installer / utiliser ce produit à moins qu'il ne puisse être câblé avec un disjoncteur de 15A minimum. Suggestion: Do not plug the device into RCS-13U directly, please using circuit breaker between these two. This device complies with Part 15 of the FCC Rules. Operatin is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the ant…
Text truncated - open the document above for the full version.
CIXICITYYIDONGELECTRONICCO.,LTD. 012916–09 AuthoritytoActasAgent Date:_August28,2020_ AmericanCertificationBody,Inc. 6731WhittierAvenue SuiteC110 McLean,VA22101 ToWhomItMayConcern: _____IntertekTestingServiceShanghai______isauthorizedtoactonourbehalf,untilotherwise notified,forapplicationstoAmericanCertificationBody,Inc.(ACB). Wecertifythatwearenotsubjecttodenialoffederalbenefits,thatincludesFCCbenefits,pursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.862.Further,noparty,asdefinedin47 CFR1.2002(b),totheapplicationissubjecttodenialoffederalbenefits,thatincludesFCCbenefits. Thankyou, AgencyAgreementExpirationDate:____2020/12/31_____ By:________________MengjieShen____ (Signature 1 )(Printname) Title:____Manager_____ Onbehalfof:_____CixiCityYidong_ElectronicCo.,Ltd._____ (CompanyName) Telephone:______+86-574-63630755_________ 1 -Ifagroup“entity”isdesignatedastheauthorizedagent,theletterofauthorizationmustidentifythoseindividualswithin thegroupwhoareauthorizedtotakeactionontheapplication;oralternativelyastatementmustbeprovidedindicating thatastheauthorizedagent,anyindividualwithinthegroup“entity”isauthorizedtoactonbehalfoftheapplicant/ granteeandtakeactionontheapplication.See https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=33316. 2 -MustbesignedbyapplicantcontactgivenforapplicantontheFCCsite,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Lettersshouldbeplacedonappropriateletterhead.
CIXICITYYIDONGELECTRONICCO.,LTD. RequestforConfidentiality Date:August28,2020 Subject:ConfidentialityRequestfor:FCCID:S72-RC13U PursuanttoFCC47CRF0.457(d)and0.459andICRSP-100,Section9.4,theapplicantrequeststhatapartofthe subjectFCCapplicationbeheldconfidential. TypeofConfidentialityRequestedExhibit ShortTermPermanentBlockDiagrams ShortTermExternalPhotos ShortTermPermanent* 1 InternalPhotos ShortTermPermanentOperationDescription/TheoryofOperation ShortTermPermanentPartsList&Placement/BOM ShortTermPermanentTune-UpProcedure ShortTermPermanentSchematics ShortTermTestSetupPhotos ShortTermPermanent*User’sManual *Note:______(InsertExplanationasNecessary)______ CixiCityYidong_ElectronicCo.,Ltd.hasspentsubstantialeffortindevelopingthisproductanditis oneofthefirstofitskindinindustry.Havingthesubjectinformationeasilyavailableto"competition"wouldnegate theadvantagetheyhaveachievedbydevelopingthisproduct.Notprotectingthedetailsofthedesignwillresultin financialhardship. PermanentConfidentiality: Theapplicantrequeststheexhibitslistedaboveaspermanentlyconfidentialbepermanentlywithheldfrompublic reviewduetomaterialsthatcontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic. Short-TermConfidentiality: Theapplicantrequeststheexhibitsselectedaboveasshorttermconfidentialbewithheldfrompublicviewfora periodof___(specifynumberofdaysnottoexceed180) 2 ___daysfromthedateoftheGrantofEquipment Authorizationandpriortomarketing.Thisistoavoidprematurereleaseofsensitiveinformationpriortomarketing orreleaseoftheproducttothepublic.ApplicantisalsoawarethattheyareresponsibletonotifyACBintheevent informationregardingtheproductortheproductismadeavailabletothepublic.ACBwillthenreleasethe documentslistedaboveforpublicdisclosurepursuanttoFCCPublicNoticeDA04-1705. NOTEforIndustryCanadaApplications: TheapplicantunderstandsthatuntilsuchtimethatICdistinguishesbetweenShortTermandPermanent Confidentiality,eithertypeofmarkedexhibitabovewillsimplybemarkedConfidentialwhensubmittedtoIC. Sincerely, By:________________MengjieShen_________ (Signature/Title 3 )(Printname) 1 -Theasteriskeditems(*)requirefurtherjustificationbeforepermanentconfidentialitywillbeallowed.Thesealsocurrently requirereviewbytheFCCundertheirPermit-But-Askpolicybeforethegrantisissuedandcandelaycompletionofan application.Furtherjustificationshouldbeaddedtothenoteabove.Onesuchexampleforapotteddevicewouldbe:“The EUTisFULLYpottedusinganon-removableepoxybasedmaterial.Removalofpottingmaterialcausesirreparable damagetointernalcircuitry.Seephotographsexhibitsthatoutlinethedevicebeforeandafterpotting.” 2 -Pleaserefertohttp://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdfforcomplete details. 3 -MustbesignedbyapplicantcontactgivenforapplicantontheFCCsite,orbytheauthorizedagentifanappropriate authorizedagentletterhasbeenprovided.Lettersshouldbeplacedonappropriateletterhead.
External Photo
Label unit: mm Location Location
Internal Photo Antenna location
Cixi City Yidong Electronic Co., Ltd. SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: RC-13U REPORT NUMBER 200700620SHA-002 ISSUE DATE August 28, 2020 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCSAR-01_V1© 2018 Intertek Page 2 of 8 Report no.: 200700620SHA-002 Applicant: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China Manufacturer: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China Manufacturing site: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China FCC ID: S72-RC13U IC: 10931A-RC13U SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1091, FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Eric Li Reviewer Daniel Zhao Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 3 of 8 Revision History Report No. Version Description Issued Date 200700620SHA-002 Rev. 01 Initial issue of report August 28, 2020 Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 4 of 8 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: Wireless remote transmitter Type/Model: RC-13U Description of EUT: The EUT is Wireless Remote Control which supports SRD function. It works at 433.92MHz Frequency, there is only one model, we test it and list the worst results in this report. Rating: 3VDC EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample received date: 2020.8.25 Date of test: 2020.8.25~2020.8.27 1.2 Technical Specification Operating Frequency: 433.92MHz Type of Modulation: ASK Antenna: PCB Antenna, 0dBi Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 5 of 8 1.3 Description of Test Facility Name: Intertek Testing Services Shanghai Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L0139 FCC Accredited Lab Designation Number: CN1175 IC Registration Lab Registration code No.: 2042B-1 VCCI Registration Lab Registration No.: R-4243, G-845, C-4723, T-2252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 6 of 8 2 SAR Assessment Test result: Pass 2.1 SAR Test Exclusion Limit 100 MHz – 6 GHz and ≤ 50 mm Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 7 of 8 100 MHz – 6 GHz and > 50 mm < 100 MHz and < 200 mm Report No.: 200700620SHA-002 TEST REPORT TTRFFCCSAR-01_V1© 2018 Intertek Page 8 of 8 2.2 Assessment Results The highest EIRP adjusted with tune-up tolerance is 89.30-95.3= -6.0dBm =0.25mW < 22mW (Test Exclusion Thresholds of 450MHz at 5mm). Therefore, the SAR requirement is deemed to be satisfied without test. ******************************************* END ************************************
Cixi City Yidong Electronic Co., Ltd. RF TEST REPORT Report Type: FCC Part 15.231 & ISED RSS-210 RF report Model: RC-13U REPORT NUMBER: 200700620SHA-001 ISSUE DATE: August 28, 2020 DOCUMENT CONTROL NUMBER: TTRF15.231_V1 © 2018 Intertek Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.231_V1 © 2018 Intertek Page 2 of 30 Report no.: 200700620SHA-001 Applicant: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China Manufacturer: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China Manufacturing site: Cixi City Yidong Electronic Co., Ltd. Guanhaiwei Industrial West Zone, Cixi City, Ningbo 315315, P.R. China FCC ID: S72-RC13U IC: 10931A-RC13U SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2019): Radio Frequency Devices (Subpart C) ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-210 Issue 10 (December 2019): Licence-Exempt Radio Apparatus: Category I Equipment RSS-Gen Issue 5 Amendment 1 (March 2019): General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Eric Li Reviewer Daniel Zhao Report No.: 200700620SHA-001 TEST REPORT TTRF15.231_V1 © 2018 Intertek Page 3 of 30 Content REVISION HISTORY................................................................................................................................................ 4 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 5 1 GENERAL INFORMATION ............................................................................................................................. 6 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 6 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 7 2 TEST SPECIFICATIONS ................................................................................................................................... 8 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 8 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 8 2.3 TEST SOFTWARE LIST ............................................................................................................................................ 8 2.4 TEST PERIPHERALS LIST ......................................................................................................................................... 8 2.5 TEST ENVIRONMENT CONDITION: ............................................................................................................................ 9 2.6 INSTRUMENT LIST .............................................................................................................................................. 10 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 11 3 FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ...................................... 12 3.1 LIMIT .............................................................................................................................................................. 12 3.2 MEASUREMENT PROCEDURE ............................................................................................................................... 13 3.3 TEST CONFIGURATION ........................................................................................................................................ 14 3.4 TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 16 4 POWER LINE CONDUCTED EMISSION ......................................................................................................... 22 4.1 LIMIT .............................................................................................................................................................. 22 4.2 TEST CONFIGURATION ........................................................................................................................................ 22 4.3 MEASUREMENT PROCEDURE ..................................................................................…
Text truncated - open the document above for the full version.
Test Setup
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Wireless remote transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wi-Fi Smart Adaptor
Equipment Class
DTS - Digital Transmission System