S85-DAS900Antenna Distribution System

Channel D Solutions, Inc.
Antenna Distribution System - FCC ID S85-DAS900 - Channel D Solutions, Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 11, 2013
Application Purpose
Original Equipment
Date of Application
Mar 11, 2013
Equipment Note
Antenna Distribution System
Frequency Range
902.57000000 - 926.65000000
Company
Channel D Solutions, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0534 Manufacturer: Channel D Solutions, Inc. Model: DAS-900 Manual DAS-900 Antenna Distribution System Serial Number: User Manual Documentation and Reference Guide www.channelDsolutions.com Sales - 615-323-2852 Tech Support - 706-622-3589 Customer: Build Date: Serial Number: AC Power fuse – Type GMA 3A Fast Blow (Spare located in connector) Location – Integrated in AC connector AC input requirements: 85 – 250 VAC 50-60 Hz Operating Temperature Range – From -40 to +50 degrees Centigrade. RF Input Connector: RP-TNC Jack RF Output (To Antenna) Connector: RP-N Jack Warranty – One year parts and labor. Physical damage due to use/abuse is not covered under warranty. See Limited Warranty statement at the end of this manual. Customer pays shipping to Channel D Solutions. WARNING – To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Do not use this apparatus near water. Do not expose the apparatus to dripping or splashing. Do not place objects filled with liquids, such as vases, on the apparatus. The DAS-900 shall be connected to a main socket outlet having a protective grounding connection. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarizing or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point of exit on the DAS-900. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to manufacturer. Servicing is required when the apparatus has been damaged in any way, for example if the power-supply cord has been damaged, liquid has been spilled or objects have fallen into the unit, or if it has been exposed to rain, moisture, does not operate normally, or has been dropped. A/C Power Warning: Users should exercise extreme care when working with electricity. Additional care should be used when working with electricity outdoors in inclement weather. When working outdoors or near water, always connect the system into a ground-fault interrupting circuit. There are no user- serviceable parts inside the DAS-900. Opening the case may expose dangerous electrical components, and will void the warranty. Important FCC and Safety Information I. Digital Device Statement A. The DAS-900 been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the Rules and Regulations of the U.S. Federal Communications Commission (the FCC) . This product is marketed as Class B digital device. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. B. This equipment generates, uses, and can radiate radio-frequency energy. If not installed and used in accordance with all instructions, it may cause harmful interference to radio communications. C. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. II. Intentional Radiator Statement A. The DAS-900 is ONLY to be used with the modular, low-power radio transceiver module that operates pursuant to Part 15 of the FCC’s Rules. The DAS-900 can only be operated AS A COMPLETE SYSTEM under FCCID S85-DAS900 B. Operation is subject to the following conditions: 1. The DAS-900 system may not cause harmful interference to other users of the radio spectrum. 2. Upon notification by a representative of the FCC that a DAS-900 system is causing harmful interference, use of the system must be suspended. Operation must not resume until the condition causing the harmful interference has been corrected. 3. The DAS-900 system must accept any interference received, including interference that may cause undesired operation. C. The DAS-900 system must be used with only with the approved antennas listed below. Use of any non-approved antenna, or any modification to any part of the DAS-900 system violates the system’s warranty, and also constitutes a violation of the FCC’s Rules and Regulations and of § 302 of the Communications Act of 1934, as amended. D. To reduce potential radio interference to other…

Text truncated - open the document above for the full version.

Cover Letter(s)

February 26, 2013 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: I hereby appoint Sam Wismer at Advanced Compliance Solutions, Inc. to act as our agent in the preparation of an application for equipment authorization of FCC ID: S85- DAS900 to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which authorization is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name and FCC IDENTIFIER listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. Sincerely, W. Michael Porter W. Michael PorterW. Michael Porter W. Michael Porter W. Michael Porter President Channel D Solutions, Inc. P.O. Box 1073 Brentwood TN 37024

Cover Letter(s)

CONFIDENTIALITY REQUEST Federal Communications CommissionDate: February 28, 2013 Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Channel D Solutions, Inc., respectfully requests confidentiality of certain materials provided with the submission of the DAS-900 under FCC ID: S85-DAS900 in accordance with 47 CFR 0.457(d) and 47 CFR 0.459. The confidentiality request applies to the System Block Diagram and Theory of Operation contained in this filing and included in the following files. 12-0534 – System Block Diagram.pdf 12-0534 – Theory of Operation.pdf The DAS-900 has been developed at considerable effort and expense by Channel D Solutions, Inc. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company's business advantage. I appreciate your assistance in this matter. Sincerely, W. Michael PorterW. Michael Porter PresidentFebruary 28, 2013 Channel D Solutions, Inc. P.O. Box 1073 Brentwood TN 37024

Cover Letter(s)

5015 B. U. Bowman Dr. Buford, GA 30518 February 27, 2013 ACS TCB 5015 B.U. Bowman Drive Buford, GA 30518 Re: FCC ID: S85-DAS900 To Whom It May Concern: The following application is submitted on behalf of our client, Channel D Solutions, Inc., for evaluation of their model DAS-900 for certification under FCC Part 15.247. The DAS-900 is an Antenna Distribution system that provides wireless communications through the use of a frequency-hopping spread-spectrum RF module and a 900 MHz wireless intercom system, which transmits a digitally encoded signal used to expand communications coverage into areas that cannot be covered by a single antenna. The DAS-900 was tested in full to the requirements of the aforementioned rules and was found to be in compliance. Sincerely, Sam Wismer Vice President, Technology Advanced Compliance Solutions, Inc.

Cover Letter(s)

February 28, 2013 DAS-900 Module Certification To Whom It May Concern: Regarding Part 15 Unlicensed Modular Transmitter Approval, the following requirements called out in Part 15.212(a)(1) are observed: 1. The DAS-900 has its own RF shielding. 2. The DAS-900 modular transmitter has buffered modulation/data inputs to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. 3. The DAS-900 employs on board power supply regulation. 4. The DAS-900 employs a MMCX connector on the module, qualifying as a unique antenna coupler. 5. The DAS-900 was tested in a stand-alone configuration. 6. The DAS-900 has a permanently affixed label with the FCC ID: S85-DAS900. 7. An instruction manual is provided with the system authorized under FCC ID: S85-DAS900, detailing proper installation and usage. 8. The DAS-900 complies with RF exposure requirements at a distance of 20 cm from the intentional radiator. J. Michael Motes Chief Engineer Channel D Solutions, Inc. P.O. Box 1073 Brentwood, TN 37024 Channel D Solutions, Inc. P.O. Box 1073 Brentwood TN 37024

Cover Letter(s)

Advanced Compliance Solutions – 5015 B.U. Bowman Drive, Buford, GA 30518 Phone: (770) 831-8048 Fax: (770) 831-8598 March 4, 2013 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Channel D Solutions, Inc. respectfully requests confidentiality of certain materials provided with the submission of the DAS-900 under FCC ID: S85-DAS900 in accordance with 47 CFR 0.457(d) and 47 CFR 0.459. The following documents have been provided by a third party and require confidential treatment: 12-0534 – Schematics – Third Party – RFM.pdf 12-0534 – System Block Diagram – Third Party – RFM.pdf 12-0534 – Theory of Operation – Third Party – RFM.pdf The DAS-900 has been developed at considerable effort and expense by Channel D Solutions, Inc. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company’s business advantage. I appreciate your assistance in this matter. Sincerely, Sam Wismer Vice President, Technology Agent

Cover Letter(s)

Advanced Compliance Solutions – 5015 B.U. Bowman Drive, Buford, GA 30518 Phone: (770) 831-8048 Fax: (770) 831-8598 March 4, 2013 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Channel D Solutions, Inc. respectfully requests confidentiality of certain materials provided with the submission of the DAS-900 under FCC ID: S85-DAS900 in accordance with 47 CFR 0.457(d) and 47 CFR 0.459. The following documents have been provided by a third party and require confidential treatment: 12-0534 – Schematics – Third Party – L-com.pdf 12-0534 – System Block Diagram – Third Party – L-com.pdf 12-0534 – Theory of Operation – Third Party – L-com.pdf The DAS-900 has been developed at considerable effort and expense by Channel D Solutions, Inc. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company’s business advantage. I appreciate your assistance in this matter. Sincerely, Sam Wismer Vice President, Technology Agent

External Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0534 Manufacturer: Channel D Solutions, Inc. Model: DAS-900 External Photos Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 2 Figure 1: Transceiver Figure 2: Transceiver Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 3 Figure 3: Transceiver Figure 4: Transceiver Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 4 Figure 5: Amplifier Figure 6: Amplifier Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 5 Figure 7: Amplifier Figure 8: Amplifier Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 6 Figure 9: Amplifier Figure 10: Amplifier

ID Label/Location Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0534 Manufacturer: Channel D Solutions, Inc. Model: DAS-900 Label Information Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 2 Figure 1: Transceiver Figure 2: Amplifier

Internal Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0534 Manufacturer: Channel D Solutions, Inc. Model: DAS-900 Internal Photos Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 2 Figure 1: Transceiver Figure 2: Transceiver Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 3 Figure 3: Amplifier Figure 4: Amplifier PCB Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 4 Figure 5: Amplifier PCB

RF Exposure Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0534 Manufacturer: Channel D Solutions, Inc. Model: DAS-900 RF Exposure Model: DAS-900FCC ID: S85-DAS900IC: 10899A-DAS900 ACS Project: 12-0534Advanced Compliance SolutionsPage 2 General Information: Applicant:Channel D Solutions, Inc. Device Category:Mobile Environment:General Population/Uncontrolled Exposure Technical Information: Antenna Type / Gain:TerraWave Model M202020R10007 Dipole / 2 dBi TerraWave Model M3030035O11206 Ceiling Mount Omni / 3.5 dBi Max Directional Gain:3.5 dBi + 10*Log(8) = 12.53 dBi Max Conducted Power: 21.05 dBm, 127 mW Max System EIRP:33.58 dBm, 2280 mW Exposure Conditions:Greater than 20 centimeters Note: The directional gain was calculated based on FCC KDB 662911 D01 Multiple Transmitter Output v01r02 as worst case, assuming (8) correlated outputs. However, in a normal operating configuration the antennas cannot be installed such that the patterns overlap. As worst case, even though not achievable for system operation, the directional gain calculation and maximum EIRP calculation were based collocated correlated transmissions. MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: S = 2 4R PG  Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) MPE Calculator for Mobile Equipment Limits for General Population/Uncontrolled Exposure* 914.6121.050.61127.4312.5317.906 200.454 Power Density (mW/cm^2) Distance (cm) Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/Cm2) Radio Power (mW) Antenna Gain (dBi) Antenna Gain (mW eq.) Installation Guidelines The installation manual should contain text similar to the following advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: RF Exposure In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure and the general population.

Test Report

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Test Report FCC ID: S85-DAS900 IC: 10899A-DAS900 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Report Number: 12-0534.W06.1A Manufacturer: Channel D Solutions, Inc. Model: DAS-900 Test Begin Date: January 18, 2013 Test End Date: February 18, 2013 Report Issue Date: February 27, 2013 FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612-0 This report is not be used to claim certification, approval, or endorsement by NVLAP, NIST or any government agency. Reviewed by: Kirby Munroe Director, Wireless Certifications ACS, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 23 pages 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 TABLE OF CONTENTS 1GENERAL ............................................................................................................................................ 3 1.1PURPOSE.......................................................................................................................................... 3 1.2PRODUCT DESCRIPTION................................................................................................................... 3 1.3TESTMETHODOLOGY ANDCONSIDERATIONS................................................................................. 3 2TEST FACILITIES.............................................................................................................................. 4 2.1LOCATION....................................................................................................................................... 4 2.2LABORATORYACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS................................................ 4 2.3RADIATEDEMISSIONSTESTSITEDESCRIPTION.............................................................................. 5 2.3.1Semi-Anechoic Chamber Test Site .......................................................................................... 5 2.3.2Open Area Tests Site (OATS) ................................................................................................. 6 2.4CONDUCTEDEMISSIONSTESTSITEDESCRIPTION........................................................................... 7 3APPLICABLE STANDARD REFERENCES.................................................................................... 7 4LIST OF TEST EQUIPMENT............................................................................................................ 8 5SUPPORT EQUIPMENT .................................................................................................................... 9 6EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 9 7SUMMARY OF TESTS ......................................................................................................................10 7.1ANTENNAREQUIREMENT–FCC:SECTION15.203 ........................................................................10 7.2POWERLINECONDUCTEDEMISSIONS–FCC:SECTION15.207IC:RSS-GEN7.2.4.......................10 7.2.1Measurement Procedure........................................................................................................10 7.2.2Measurement Results .............................................................................................................10 7.3PEAKOUTPUTPOWER-FCCSECTION15.247(B)(2)IC:RSS-210A8.4(1)....................................12 7.3.1Measurement Procedure........................................................................................................12 7.3.2Measurement Results .............................................................................................................12 7.4CHANNELUSAGEREQUIREMENTS.................................................................................................13 7.4.1Carrier Frequency Separation – FCC: Section 15.247(a)(1) IC: RSS-210 A8.1(b)..............13 7.4.1.1Measurement Procedure ..........................................................................................................................13 7.4.1.2Measurement Results ..............................................................................................................................13 7.4.2Number of Hopping Channels – FCC: Section 15.247(a)(1)(i) IC: RSS-210 A8.1(c) ...........14 7.4.2.1Measurement Procedure ..........................................................................................................................14 7.4.2.2Measurement Results ..............................................................................................................................14 7.4.3Channel Dwell Time – FCC: Section 15.247(a)(1)(i) IC: RSS-210 A8.1(c)..........................15 7.4.3.1Measurement Procedure ..........................................................................................................................15 7.4.3.2Measurement Results ..............................................................................................................................15 7.4.420dB / 99% Bandwidth - FCC: Section 15.247(a)(1)(i) IC: RSS-210 A8.1(c) .....................16 7.4.4.1Measurement Procedure ..........................................................................................................................16 7.4.4.2Measurement Results ..............................................................................................................................16 7.5BAND-EDGECOMPLIANCE ANDSPURIOUSEMISSIONS-FCC15.247(D)IC:RSS-210A8.5 ...........18 7.5.1Band-Edge Compliance of RF Conducted Emissions............................................................18 7.5.1.1Measurement Procedure ............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

W Michael Porter(President)
[email protected](615)480-6965Fax: (615)371-5005

Test Firm

Advanced Compliance Solutions, Inc.Randy Abernathy
[email protected]770-831-8048Fax: 770-831-8598

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.57 MHz - 926.65 MHz127.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular Approval Power Output listed is conducted. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. This device must transmit with a source-based time-averaging duty factor not exceeding 0.772%. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Device must be marketed and operated as a complete system.

Other Applications from Channel D Solutions, Inc.

Antenna Distribution System - FCC ID S85-DAS2400 - Channel D Solutions, Inc.
S85-DAS2400

Antenna Distribution System

Jan 14, 2015

Equipment Class

DTS - Digital Transmission System