FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. OFI, Inc./
  3. S9C-1300

S9C-1300SAFEPLUG IN-WALL ELECTRICAL OUTLET

OFI, Inc.
SAFEPLUG IN-WALL ELECTRICAL OUTLET - FCC ID S9C-1300 - OFI, Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jan 21, 2008
Application Purpose
Original Equipment
Date of Application
Jan 20, 2008
Equipment Note
SAFEPLUG IN-WALL ELECTRICAL OUTLET
Frequency Range
13.56000000 - 13.56000000
Company
OFI, Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SafePlug Model 1300 Electrical Outlet Installation Manual Read completely before getting started. SafePlug ™ ® Fire, Shock & Power Protection! Important Information SafePlug® electrical outlets add fire, shock and power-fault protection to your home or office. To deliver electricity to an electrical device with the protection of the safety features found in a SafePlug Model 1300 electrical outlet, use a cord-set plug equipped with RightPlug™ technology. If the electrical device is not equipped with the RightPlug technology, retrofit it with a Model 10XX Series RightPlug compliant Tag. Model 10XX Series RightPlug complaint Tags are available on-line at www. safeplug.com or by calling 1-877-755-7233. Please follow the “SafePlug Model 10XX Tag Installation Manual” for Tag installation instructions. WARNINGS: • Refer to the local building code for additional installation requirements. • SafePlug electrical outlets interrupt the electrical supply to devices plugged into them when an unsafe condition is detected. As such SafePlug electrical outlets must not be used for life sustaining or any other electrical device that could cause an adverse condition if disconnected. Use on a refrigerator or freezer could result in food spoilage if the SafePlug electrical outlet detects an electrical fault. • SafePlug electrical outlets should be installed by a qualified electrician. • Residential electrical systems contain lethal voltages. Disconnect power before installing this product. • Operation of any RF generating equipment, including this product, may interfere with the functionality of near-by inadequately protected medical devices. Consult a physician or the manufacturer of the medical device to answer any questions. Other near-by electronic equipment may also be subject to interference. • Do not touch the plug blades when inserting a plug into any electrical outlet. The SafePlug electrical outlet can deliver high voltages like a standard electrical outlet when a RightPlug equipped cord-set is partially inserted. • SafePlug electrical outlets are designed to have electrical devices plugged into them directly. Use of an extension cord may reduce fire protection provided by the SafePlug electrical outlet for the device(s) plugged into the extension cord. • SafePlug electrical outlets may disconnect power from a computer without warning due to an electrical fire hazard or a power fault. This sudden loss of power can result in loss of computer records, information or documents. For computers, use an uninterruptible power supply between the SafePlug outlet and the computer. NOTES: • This device complies with FCC electromagnetic emission limits for mobile devices. This device complies with Health Canada Safety Code 6 electromagnetic exposure limits for the general public. For maximum safety, we recommend against operating any electronic device within 8 inches (20cm) of your body for extended periods of time, unless the device has been specifically designed and tested for such use. USA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help Warning: Changes or modifications not expressly approved by OFI, Inc. could void the user’s authority to operate the equipment CANADA This Class B digital apparatus complies with Canadian ICES- 003. This device complies with Canadian RSS-210. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Specifications: SafePlug Model 1300 Outlet Wiring For use on 15 Ampere branch circuits and with 14 AWG solid copper conductors only. Electrical Supply 125V 60Hz 15A Max. Load 15A, 1875W resistive, 1000W tungsten, ¾ hp. Temperature 0ºC to 40ºC, (32ºF to 104ºF) Humidity 15% to 95% R.H. (non-condensing) Location Indoor use only RightPlug Interface ISO 14443 type B Frequency 13.56 MHz Power < 90mW Read Range < 10mm Limited Warranty Information Disclaimer 2D2C, Inc.’s products are warranted to be free from defects in material or workmanship for thirty (30) days from the date of sale to the original purchaser. THE FOREGOING LIMITED WARRANTY IS 2D2C, INC’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. 2D2C MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. 2D2C, Inc's liability arising out of the…

Text truncated - open the document above for the full version.

Cover Letter(s)

Jan. 16, 2008 Ultratech Engineering Labs Inc. FCC TCB Division 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Subject: FCC Certification Application Testing under FCC PART 15, Subpart C - Unlicensed Low Power Transmitter operating in the frequency band 13.553-13.567 MHz. Product: SAFEPLUG IN-WALL ELECTRICAL OUTLET Model No.: 1300 FCC ID: S9C-1300 Dear Sir/Madam As appointed agent for OFI, Inc., we would like to submit the application for certification of the above product. Please review all required documents uploaded to your E-Filing web site. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs Ultratech’s Accreditations: 0685 31040/SIT C-1376 46390-2049 200093-0 SL2-IN-E-1119R 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected]

Cover Letter(s)

OFI, Inc „ 1351 Strasburg Road, Kitchener, Ontario N2R 1H2 Canada „ Voice (519) 884-3100, Fax (519) 884-9800 January 9, 2008 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Authority to Act as an Agent to FCC Applicant: OFI, Inc. Product: SafePlug Portable safety Outlet Model: 1300 FCC ID: S9C-1300 Dear Sir/Madam, I hereby appoint UltraTech Engineering Labs Inc. (UltraTech) to act as my agent in preparation of this application to F.C.C. for authorization of equipment under F.C.C. Rules. I also certify that the information provided, properly described the device or system for which authorization is required. Regards Nick Jones V.P. Technology

Cover Letter(s)

OFI, Inc „ 1351 Strasburg Road, Kitchener, Ontario N2R 1H2 Canada „ Voice (519) 884-3100, Fax (519) 884-9800 January 9, 2008 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. Subject: Request for withholding from public disclosure the schematic diagrams and system block diagrams pursuant to an application for certification. Applicant: OFI, Inc. Product: SafePlug In-wall Electrical Outlet Model: 1300 FCC ID: S9C-1300 Dear Sir/Madam, We, OFI, Inc., would like to request that the schematic diagrams, system block diagrams and operational description, submitted with the application for certification be withheld from public disclosure as per Section 0.459 of FCC Rules. This request is made under the provisions of Section 0.457(d) of the Commission's Rules, and Section 552(b)(4) of the Freedom of Information Act. These sections authorize as a withholding from public inspection materials which would be privileged as a matter of law if retained by the person submitting them, and materials which would not customarily be released to the public by that person. If you have any queries, please do not hesitate to contact us by our TOLL FREE numbers: (877) 912 7233 Yours truly, Nick Jones V.P. Technology

External Photos

Annex 2 – External Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 1 FCC ID: S9C-1300 IC: 5850A-1300 Annex 2 – External Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 2 FCC ID: S9C-1300 IC: 5850A-1300

ID Label/Location Info

OFI Inc , . Nick JonesOFI Part No. 13001of2 11/30/07 1.3 ProjectDrawn BySheet DateRevision Title © OFI Inc. If you received this document in electronic format, you may print onehardcopy. Duplication or distribution of this document in hardcopy or electronicformat, and printing of more than one hardcopy is prohibited without writtenpermission from OFI Inc.. This document contains Confidential and ProprietaryInformation of OFI Inc. which may only be used as and when specifically SafePlug Inwall Outlet Dimensions All dimensions in mm (inch), scale 1:1 (100%) unless otherwise noted The frame of this drawing is 406.4mm (16.00) by 254.0mm (10.00) WARRANTY VOID IF UNIT IS OPENED OR T AMPERED WITH. GARANTIE ANNULEE SI OUVERT , OU DANS LES CAS DE HOT NOIR WHITE BLANC G WIRE STRIP WARNING: ATTENTION: MAUVAISE UTILIZA TION. DÉNUDE DE FIL Model 1300 OFCI, PFCI, SFCI Protected Outlet ® Model 1300FCC ID: S9C-1300IC: 5850A-1300125VAC 60 Hz 15 Amp US Pat. 6,049,143 Cdn Pat. 2,341,676Patent(s) pending. This device complies with Part 15 of the FCCRules. Operation is subject to the followingtwo conditions: (1) this device may not causeharmful interference, and (2) this device mustaccept any interference received, includinginterference that may cause undesiredoperation. Made In Canada /Fabriqué au Canada Fire, Shock & Power Protection! ® 230670 R CUS

Internal Photos

Annex 3 – Internal Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 1 FCC ID: S9C-1300 IC: 5850A-1300 Annex 3 – Internal Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 2 FCC ID: S9C-1300 IC: 5850A-1300 Annex 3 – Internal Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 3 FCC ID: S9C-1300 IC: 5850A-1300 Annex 3 – Internal Photographs of SAFEPLUG IN -WALL ELECTRICAL OUTLET, Model 1300 Photo # 4 FCC ID: S9C-1300 IC: 5850A-1300 Loop Antenna

Test Report

Jan. 16, 2008 Ultratech Engineering Labs Inc. FCC TCB Division 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Subject: FCC Certification Application Testing under FCC PART 15, Subpart C - Unlicensed Low Power Transmitter operating in the frequency band 13.553-13.567 MHz. Product: SAFEPLUG IN-WALL ELECTRICAL OUTLET Model No.: 1300 FCC ID: S9C-1300 Dear Sir/Madam As appointed agent for OFI, Inc., we would like to submit the application for certification of the above product. Please review all required documents uploaded to your E-Filing web site. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs Ultratech’s Accreditations: 0685 31040/SIT C-1376 46390-2049 200093-0 SL2-IN-E-1119R 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] Jan. 16, 2008 OFI, Inc. 1351 Strasburg Road Kitchener, Ontario Canada, N2R 1H2 Attn.: Mr. Nick Jones Subject: FCC Certification Application Testing under FCC PART 15, Subpart C - Unlicensed Low Power Transmitter operating in the frequency band 13.553-13.567 MHz. Product: SAFEPLUG IN-WALL ELECTRICAL OUTLET Model No.: 1300 FCC ID: S9C-1300 Dear Mr. Jones, The product sample, as provided by you, has been tested and found to comply with FCC PART 15, Subpart C - Unlicensed Low Power Transmitter operating in the frequency band 13.553-13.567 MHz. Enclosed you will find copies of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs Ultratech’s Accreditations: 0685 31040/SIT C-1376 46390-2049 200093-0 SL2-IN-E-1119R 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] SAFEPLUG IN-WALL ELECTRICAL OUTLET Model No.: 1300 FCC ID: S9C-1300 Applicant: OFI, Inc. 1351 Strasburg Road Kitchener, Ontario Canada, N2R 1H2 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART C Unlicensed Low Power Transmitter operating in the band 13.553-13.567 MHz UltraTech's File No.: OFI-004FCC15-225 This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: Jan. 16, 2008 Report Prepared by: Dan Huynh Tested by: Hung Trinh, RFI Test Technician and Phuong Luu, EMI Technician Issued Date: Jan. 16, 2008 Test Dates: Jan. 07-14, 2008 ƒ The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. ƒ This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Tel.: (905) 829-1570 Fax.: (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected], Email: [email protected] 0685 31040/SIT C-1376 46390-2049 200093-0 SL2-IN-E-1119R FCC PART 15, SUBPART C, Sec. 15.225 - UNLICENSED LOW POWER TRANSMITTER Page 2 SAFEPLUG IN-WALL ELECTRICAL OUTLET, Model No.: 1300 FCC ID: S9C-1300 ULTRATECH GROUP OF LABS File #: OFI-004FCC15-225 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Jan. 16, 2008 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected] , Website: http://www.ultratech-labs.com All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1. INTRODUCTION .................................................................................................................................. 4 1.1. SCOPE ................................................................................................................................................................. 4 1.2. RELATED SUBMITAL(S)/GRANT(S).......................................................................................................................... 4 1.3. NORMATIVE REFERENCES ............................................................................................................................ 4 EXHIBIT 2. PERFORMANCE ASSESSMENT ....................................................................................................... 5 2.1. CLIENT INFORMATION ...................................................................................................................................... 5 2.2. EQUIPMENT UNDER TEST (EUT) INFORMATION............................................................................................... 5 2.3. EUT’S TECHNICAL SPECIFICATIONS........................................................................................................... 6 2.4. LIST OF EUT’S PORTS ...................................................................................................................................... 6 2.5. ANCILLARY EQUIPMENT ............................................................................................................................... 6 2.6. GENERAL TEST SETUP .................................................................................................................................... 7 EXHIBIT 3. EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS ........................ 8 3.1. CLIMATE TEST CONDITIONS................................................................................................................................... 8 3.2. OPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS ............................................................................ 8 EXHIBIT 4. SUMMARY OF TEST RESULTS ........................................................................................................9 4.1. LOCATION OF TESTS ............................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Annex 1 – Photographs of Test Setup Page 1 SAFEPLUG IN-WALL ELECTRICAL OUTLE T, Model 1300 FCC ID: S9C-1300 IC: 5850A-1300 Photo #1: AC Conducted Emissions Measurements Annex 1 – Photographs of Test Setup Page 2 SAFEPLUG IN-WALL ELECTRICAL OUTLE T, Model 1300 FCC ID: S9C-1300 IC: 5850A-1300 Photo #2: AC Conducted Emissions Measurements Annex 1 – Photographs of Test Setup Page 3 SAFEPLUG IN-WALL ELECTRICAL OUTLE T, Model 1300 FCC ID: S9C-1300 IC: 5850A-1300 Photo #3: Radiated Emissions Annex 1 – Photographs of Test Setup Page 4 SAFEPLUG IN-WALL ELECTRICAL OUTLE T, Model 1300 FCC ID: S9C-1300 IC: 5850A-1300 Photo #4: Radiated Emissions

Contact Information

Applicant

Geoff Jones(V.P. Engineering)
[email protected]5198843100Fax: 5198849800

Technical Contact

Ultratech Engineering Labs IncTri M Luu
[email protected]905-829-1570

3000 Bristol Circle · Oakville · Canada

Test Firm

UltraTech Engineering Labs Inc.Tri Luu
[email protected]905-829-1570Fax: 905-829-8050

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from OFI, Inc.

SafePlug Outlet Control Board - FCC ID S9C-3064 - OFI, Inc.
S9C-3064

SafePlug Outlet Control Board

Nov 23, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SafePlug Outlet Control Board - FCC ID S9C-3063 - OFI, Inc.
S9C-3063

SafePlug Outlet Control Board

Jul 07, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter