0, 1 0, 0, 2 3 0, 4 ORIGINAL OPERATING INSTRUCTIONS PS 1000 x‑scan It is essential that the operating instruc- tions are read before the tool is operated for the first time. Always keep these operating instructions together with the tool. Ensure that the operating instructions are with the tool when it is given to other per- sons. ContentsPage 1. General information1 2. Description2 3. Before use2 4. Operation2 5. Settings5 1These numbers refer to the corresponding illustra- tions. The illustrations can be found on the fold-out cover pages. Keep these pages open while studying the operating instructions. Scanner1 @ Grip ; Wheels = Cancel button % Start/stop button Buttons2 & Function buttons ( On/off button ) Rocker switch + Confirmation button (OK) § Home button 1. General information 1.1 Explanation of the pictograms and other information Symbols Read the operating instructions before use. 2. Description 2.1 Use The PS 1000 is used for locating objects embedded in concrete structures. 2.2 Limitations of use The tool complies with the requirements of EN 302066-1 and 302067-2. Prior to planned use of ground or wall penetrating radar equipment, the user/operator should check that there are no sensitive radio sites/systems in the near vicinity (airfields, radio astronomy sites, etc.). These sites may be generally defined in the licence issued by the responsible national administration. If these are present in the area, then liaison with the organization en 1 concerned should take place to obtain agreement, prior to any measurements being performed. 3. Before use 3.1 Inserting the battery pack and switching on the device3 1. Fully charge the PSA 81 battery pack (see Operating instructions for PUA 81 power supply). 2. When charged, insert the battery pack. 3. Switch the tool on by pressing the on/off button. Outside the operating temperature, the fault message no. 00012 is displayed and the device is automatically switched off. Allow the device to cool down or warm up and then switch it on. 3.2 Settings On brand-new devices, you will first be prompted to select the language, country, region and unit. 1. Use the rocker switch to select the desired language and confirm your choice with the "OK" function button. 2. Then use the rocker switch and the confirmation button to select the required parameter and then carry out the settings. 3. After carrying out the settings, use the "OK" function button to confirm them. NOTEYou can also use the "Skip" function button to shift these settings so that they will remain the same the next time the device is switched on. 4. Operation 4.1 Displaying the Operating instructions 1. Press the home button for 3 seconds. The Operating instructions will be shown context-sensitively in the display field. You can then navigate throughout the complete Operating instructions. 2. To close the Operating instructions, press the "Back" function button. 4.2 Basic functions You can use the function buttons to select the available functions. You can use the rocker switch to shift the focus, change parameter values or, depending on the setting, shift the cross hairs, change the layer thickness, etc. You can use the "OK" confirmation button to select the focalized element or start data processing. en 2 4.3 Carrying out Quickscan detection Locating objects embedded in concrete structures in real time mode for direct marking. 1. Switch the device on and navigate to the home screen using the Home button. 2. Select the "Quickscan detection" function. 3. Hold the scanner onto the surface to be examined. 4. Start the measurement with the start/stop button. A beep is heard which signals the start of the measurement and a red recording point appears in the display field. 5. Move the scanner to the left or right (at least 30 cm / 12") and back along the same measurement track over the surface to be scanned in order to locate the embedded objects. If the scanning movement is very fast, an audible and visible warning is issued. If the scanning movement is too fast, the measurement is canceled. 6. You can use the "Color scheme", "Contrast" and "Param." function buttons to adjust the visualization parameters. NOTEYou must set the values for "Param." before measuring (see Operating instructions in the device). 7. End the measurement with the start/stop button. A double beep signals that the measurement has ended. 4.4 Quickscan recording NOTE This function is not available for the PS 1000‑B version. Recording a relatively long measurement scan line in concrete structures. 1. In the home screen, select the "Quickscan recording" function. 2. Set the scanning direction. 3. Hold the scanner onto the surface to be examined. 4. Start the measurement with the start/stop button. A beep is heard which signals the start of the measurement and a red recording point appears in the display field. You must scan a minimum length of 32 cm (13") in order to receive analyzable data. The maximum scanning length is 10 m (30 ft). en 3 5. Move the scanner in the direction which you preset. If the scanning movement is very fast, an audible and visible warning is issued. If the scanning movement is too fast, the measurement is canceled. Do not change the scanning direction. If you move the scanner more than 16 cm (7") in the other direction, the measurement will be automatically canceled. 6. End the measurement with the start/stop button. A double beep signals that the measurement has ended. 7. Check the measurement result with the "Preview" function. Set the control behavior of the rocker switch using the function button at the top on the left. NOTEYou can use the "Contrast", "Param." and "View" function buttons to change the visualization parameters. If you change the "Param.", the data must be recalculated. To do this, press the "OK" confirmation button. 4.5 Image scan4 For a flat view of objects embedded in concrete structures. 1. Carry out a Quickscan detection to evaluate the orientation of t…
Text truncated - open the document above for the full version.
ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 1 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 Photo documentation of the EuT PS1000 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 2 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 3 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 4 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 5 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 16 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 Main Battery ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 17 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 18 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 Ancillary equipment PSA1000 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 19 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 Power Supply
ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 5 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009
408916 26.10.2010 PS 1000 01 Hilti = trademark of Hilti Corp., Schaan, LI Item No.: Serialnumber: 413222 123091256 Power: 7.4V=nom./1.6A This device complies with Part 15 of the FCC Rules and RSS-220 of IC. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: SDL-PS1000R1 IC: 5228-PS1000R1 408916-10.2010 Made in Switzerland Barcode 39 426311 26.10.2010 PS 1000 B 01 Hilti = trademark of Hilti Corp., Schaan, LI 408916-10.2010 Barcode 39 Made in Switzerland Power: 7.4V=nom./1.6A This device complies with Part 15 of the FCC Rules and RSS-220 of IC. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: SDL-PS1000R1 IC: 5228-PS1000R1 Item No.: Serialnumber: 413222 123091256
ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 6 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 7 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 8 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 9 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 10 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 11 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 12 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 13 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 14 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009 ATTACHMENT A to File No.: T33552 mikes-testingpartners gmbh File No. T33962, page 15 of 19 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.0, 2.2.2009
mikes-testingpartners gmbh File No. T33552-01-04KJ, page 1 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 EMI -- T E S T R E P O R T - FCC Part 15B - Test Report No. : T33552-01-04KJ 16. September 2010 ______________________________________________________________________________________________ Date of issue Type / Model Name : PS1000 Product Description : UWB Ground Penetrating Radar / In-wall imaging Device Applicant : Hilti Corporation Address : Feldkircherstrasse 100 FL-9494 Schaan Manufacturer : Escatec Switzerland AG Address : Heinrich-Wild-Strasse CH-9435 Heerbrugg Licence holder : Hilti Corporation Address : Feldkircherstrasse 100 FL-9494 Schaan Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. DAT-P-207/05-00 Registration No. DAT-P-207/05 mikes-testingpartners gmbh File No. T33552-01-04KJ, page 2 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 Contents 1 TEST STANDARDS 3 2 SUMMARY 4 3 EQUIPMENT UNDER TEST 5 3.1 Photo documentation of the EUT – Detailed photos see attachment A 5 3.2 Power supply system utilised 5 3.3 Short description of the Equipment under Test (EUT) 5 4 TEST ENVIRONMENT 6 4.1 Address of the test laboratory 6 4.2 Environmental conditions 6 4.3 Statement of the measurement uncertainty 6 4.4 Measurement protocol for FCC, VCCI and AUSTEL 7 5 TEST CONDITIONS AND RESULTS 9 5.1 Conducted emissions 9 5.2 Radiated emissions 13 6 USED TEST EQUIPMENT AND ACCESSORIES 16 mikes-testingpartners gmbh File No. T33552-01-04KJ, page 3 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 1 TEST STANDARDS The tests were performed according to following standards: FCC Rules and Regulations Part 15 Subpart A - General (October, 2009) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15 Subpart B - Unintentional Radiators (October, 2009) Part 15, Subpart B, Section 15.107 AC Line conducted emissions Class A device Class B device Part 15, Subpart B, Section 15.109 Radiated emissions, general requirements Part 15, Subpart B, Section 15.111 Antenna power conduction ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1:1992 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 mikes-testingpartners gmbh File No. T33552-01-04KJ, page 4 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 2 SUMMARY GENERAL REMARKS: None FINAL ASSESSMENT: Date of receipt of test sample : acc. to storage records Testing commenced on : 12 July 2010 Testing concluded on : 16 July 2010 Checked by: Tested by: Klaus Gegenfurtner Dipl.-Ing.(FH) Manager: Radio Group Josef Knab mikes-testingpartners gmbh File No. T33552-01-04KJ, page 5 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EUT – Detailed photos see attachment A 3.2 Power supply system utilised Power supply voltage: : 115 V / 60 Hz / 1φ Battery 7.4 V DC: 3.3 Short description of the Equipment under Test (EUT) PS 1000 is a field disturbance sensor, designed to examine and map subsurface (or interior wall) structures, which are embedded in (reinforced) concrete. The device is a hand held operated tool, which is designed to operate when in direct contact with the ground (or wall). The device is equipped with a manually operated switch and automatic movement detection provisions that cause the transmitter to cease operation practically instantly when the device is not being operated. The device is equipped with a displayed (LCD) for imaging and evaluation purposes. Number of tested samples: 2 Serial number: R0 000118V319.05.10 003 (Radiated measurements) R0 000118V319.05.10 004 (Conducted measurements) EUT operation mode: The equipment under test was operated during the measurement under the following conditions: - Continuous transmission EUT configuration: (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurements: - Monitor (Rugged PC) Model : PSA 100 - Charger (for Monitor) Model : PRA 85 - Battery Pack Model : PSA 81 - USB Mouse Model : Microsoft IntelliMouse - Interaface Cables Model : PSA 50 / PSA 51 - Model : mikes-testingpartners gmbh File No. T33552-01-04KJ, page 6 of 16 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 17.3.2010 4 TEST ENVIRONMENT 4.1 Address of the test laboratory mikes-testingpartners gmbh Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY 4.2 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 86-106 kPa 4.3 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader may notice that tolerances within the calibration of the equipment and facilities may cause additional uncertainty. The measurement uncertainty is calculated for all measurements listed in this test report acc. to CISPR 16-4-2 „Uncertainties, stati…
Text truncated - open the document above for the full version.
FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 1 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 EMI -- T E S T R E P O R T - FCC Part 15.509 - Test Report No. : T33552-01-02KJ 06. October 2010 ______________________________________________________________________________________________ Date of issue Type / Model Name : PS1000 Product Description : UWB Ground Penetrating Radar / In-wall imaging Device Applicant : Hilti Corporation Address : Feldkircherstrasse 100 FL-9494 Schaan Manufacturer : Escatec Switzerland AG Address : Heinrich-Wild-Strasse CH-9435 Heerbrugg Licence holder : Hilti Corporation Address : Feldkircherstrasse 100 FL-9494 Schaan Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. DAT-P-207/05-00 Registration No. DAT-P-207/05 FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 2 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 Contents 1 TEST STANDARDS 3 2 SUMMARY 4 3 EQUIPMENT UNDER TEST 5 3.1 Photo documentation of the EUT - Detailed photos see attachment A 5 3.2 Power supply system utilised 5 3.3 Short description of the Equipment under Test (EUT) 5 4 TEST ENVIRONMENT 6 4.1 Address of the test laboratory 6 4.2 Environmental conditions 6 4.3 Statement of the measurement uncertainty 6 4.4 Measurement Protocol for FCC, VCCI and AUSTEL 6 5 TEST CONDITIONS AND RESULTS 9 5.1 Conducted emissions 9 5.2 Spurious emissions (magnetic field) 9 kHz – 30 MHz 13 5.3 Spurious emissions radiated (electric field) 15 5.4 Emission bandwidth radiated 25 5.5 Signal deactivation 28 6 USED TEST EQUIPMENT AND ACCESSORIES 32 FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 3 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 1 TEST STANDARDS The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (October, 2009) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (October, 2009) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.509 Technical requirements for ground penetrating radars and wall imaging systems Part 15, Subpart C, Section 15.521 Technical requirements to all UWB devices OET Bulletin 65, 65A, 65B, 65C Edition 97-01, August 1997 – Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ANSI C63.4: 2009 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1: 1992 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 4 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 2 SUMMARY GENERAL REMARKS: None FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 12 July 2010 Testing concluded on : 16 July 2010 Checked by: Tested by: Klaus Gegenfurtner Dipl.-Ing.(FH) Manager: Radio Group Josef Knab FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 5 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EUT - Detailed photos see attachment A 3.2 Power supply system utilised Power supply voltage: : 115 V / 60 Hz / 1φ Battery 7.4 V DC: 3.3 Short description of the Equipment under Test (EUT) PS 1000 is a field disturbance sensor, designed to examine and map subsurface (or interior wall) structures, which are embedded in (reinforced) concrete. The device is a hand held operated tool, which is designed to operate when in direct contact with the ground (or wall). The device is equipped with a manually operated switch and automatic movement detection provisions that cause the transmitter to cease operation practically instantly when the device is not being operated. The device is equipped with a displayed (LCD) for imaging and evaluation purposes. Number of tested samples: 2 Serial number: R0 000118V319.05.10 003 (Radiated measurements) R0 000118V319.05.10 004 (Conducted measurements) EUT operation mode: The equipment under test was operated during the measurement under the following conditions: - Continuous transmission EUT configuration: (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurements: - Monitor (Rugged PC) Model : PSA 100 - Charger (for Monitor) Model : PRA 85 - Battery Pack Model : PSA 81 - USB Mouse Model : Microsoft IntelliMouse - Interaface Cables Model : PSA 50 / PSA 51 - Model : FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 6 of 32 Ohmstrasse 2-4…
Text truncated - open the document above for the full version.
FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 9 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 5 TEST CONDITIONS AND RESULTS 5.1 Conducted emissions For test instruments and accessories used see section 6 Part A 4. 5.1.1 Description of the test location Test location: Shielded Room S2 5.1.2 Photo documentation of the test set-up 5.1.3 Applicable standard According to FCC Part 15, Section 15.207(a): Except as shown in paragraphs (b) and (c) of this Section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the given limits. 5.1.4 Description of Measurement The measurements are performed following the procedures set out in ANSI C63.4 described under item 4.4.3. If the minimum limit margin appears to be less than 20 dB with a peak mode measurement, the emissions are remeasured using a tuned receiver with quasi-peak and average detection and recorded on the data sheets. 5.1.5 Test result Frequency range: 0.15 MHz - 30 MHz Min. limit margin > 5 dB FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 13 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 5.2 Spurious emissions (magnetic field) 9 kHz – 30 MHz For test instruments and accessories used see section 6 Part SER 1. 5.2.1 Description of the test location Test location: OATS1 Test distance: 3 metres 5.2.2 Photo documentation of the test set-up 5.2.1 Applicable standard According to FCC Part 15C, Section 15.209: The emissions from shall not exceed the effective field strength limits. 5.2.2 Description of Measurement The magnetic field strength from the EUT will be measured on an open area test site in the frequency range of 9 kHz to 30 MHz using a tuned receiver and a shielded loop antenna. The set up of the Equipment under test will be in accordance to ANSI C63.4. The antenna was positioned 3, 10 or 30 meters horizontally from the EUT. Measurements have been made in all three orthogonal axes and the shielded loop antenna was rotated to locate the maximum of the emissions. In the case where larger measuring distances are required the results will extrapolated based on the values measured on the closer distances according to Section 15.31(f)(2)(2). The final measurement will be performed with an EMI Receiver set to Quasi Peak detector except for the frequency bands 9 kHz to 90 kHz and 110 to 490 kHz where an average detector will be used according to Section 15.209(d)(2). The resolution bandwidth during the measurement is as follows: 9 kHz – 150 kHz: RBW: 200 Hz 150 kHz – 30 MHz: RBW: 9 kHz FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 15 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 5.3 Spurious emissions radiated (electric field) For test instruments and accessories used see section 6 Part SER 2, SER 3, CPC 3. 5.3.1 Description of the test location Test location: OATS1 Test distance: 3 metres Test location: Anechoic Chamber A1 Test distance: 1 metre 5.3.2 Photo documentation of the test set-up FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 16 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 5.3.3 Applicable standard According to FCC Part 15C, Section 15.209(a) and FCC Part 15F, Section 15.509 (d)(e) 5.3.4 Description of Measurement The radiated power of the spurious emission from the EUT is measured in a test setup following the procedures set out in ANSI C63.4. If the emission level of the EUT in peak mode complies with the average limit is 20 dB lower, then testing will be stopped and peak values of the EUT will be reported, otherwise the emission will be measured in average mode again and reported. The emission >960 MHz were measured in a typical setup, in a sandbox scenario. Instrument settings: 30 MHz – 960 MHz: RBW: 120 kHz 960 MHz – 12000 MHz RBW: 1 MHz 1164 – 1240 MHz and 1559 – 1610 MHz RBW: 1 kHz Example: Frequency Level + Factor = Level - Limit = Delta (MHz) (dBμV) (dB) dB(μV/m) dB(μV/m) (dB) 170.5 5 + 20 = 25 - 30 = -5 5.3.5 Test result f < 960 MHz Frequency (MHz) Level QP (dBμV) Bandwidth (kHz) Correct. factor (dB) Corrected level dB(μV/m) Effective limit dB(μV/m) Delta (dB) 30-960 120 <30 FCC ID: SDL-PS1000R1 mikes-testingpartners gmbh File No. T33552-01-02KJ, page 28 of 32 Ohmstrasse 2-4 x 94342 STRASSKIRCHEN x GERMANY Tel.:+49(0)9424-94810 x Fax: +49(0)9424-9481240 Rev. No. 1.1, 05.11.2008 5.5 Signal deactivation For test instruments and accessories used see section 6 Part MB. 5.5.1 Description of the test location Test location: AREA4 5.5.2 Photo documentation of the test set-up 5.5.3 Applicable standard According to FCC Part 15C, Section 15.509(c): A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter not exceeding the defined on time limit. 5.5.4 Description of Measurement The duration of transmission is measured with the spectrum analyzer. The sweep points were set to maximum for higher the time resolution. The signal is modulated; the marker of the analyzer is set to maximum amplitude at normal temperature and zero span. The analyser was set to single sweep and triggered on the button, the marker was set to the edges in order to measure the duration time and than recorded. 5.5.5 Test result By pressing the start button and not moving the DUT, the GPR emissions cease in approx. 40ms. If user presses start button and moves device for approx. 2 seconds, the device detects that it is not moving anymore and ceases UWB GPR emissions in the before…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15F | 2.44 GHz - 2.44 GHz | - |

Auto-align multi-line laser
Equipment Class
DTS - Digital Transmission System
Laser receiver
Equipment Class
DTS - Digital Transmission System
Ultra-Wideband Wallscanner
Equipment Class
UWB - Ultra Wideband Transmitter
BLE Board
Equipment Class
DTS - Digital Transmission System
inductive application
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter