Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 20, 2015
Application Purpose
Original Equipment
Date of Application
May 20, 2015
Equipment Note
WATER DANCING TOWER SPEAKER
Frequency Range
2402.00000000 - 2480.00000000
Company
Tonika Electronics Technology (Shenzhen) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

ANNEXCEUTPHOTOS C.1AppearanceoftheEUT THEFRONTOFEUT 2 / 7 THEBACKOFEUT 3 / 7 THELEFTOFEUT THERIGHTOFEUT 4 / 7 THEUPOFEUT THEDOWNOFEUT 5 / 7 6 / 7 TheRemoteControl TheAudioLine 7 / 7 TheCharger

ID Label/Location Info

Label: Labellocation:

Internal Photos

ANNEX C EUT PHOTOS C.2 Inside of the EUT EUT UNCOVER VIEW 1 EUT UNCOVER VIEW 2 2 / 5 MAIN BOARD TOP VIEW 1 MAIN BOARD BACK VIEW 1 3 / 5 MAIN BOARD TOP VIEW 2 MAIN BOARD TOP VIEW 3 PCB Antenna 4 / 5 MAIN BOARD BACK VIEW 3 MAIN BOARD TOP VIEW 4 5 / 5 MAIN BOARD BACK VIEW 5 --END OF REPORT--

RF Exposure Info

RFExposureEvaluationForFCCID:SDNTA-440-01; Referusermanualthisdeviceisawaterdancingtowerspeakerthattheminimumdistancebetweenhuman’s bodyis20cm.Basedonthe47CFR2.1091,thisdevicebelongstoMobiledevice.Thedefinitionofthe categoryasfollowing: MobileDerives: CFRTitle47§2.1091(b) (b)Forpurposesofthissection,amobiledeviceisdefinedasatransmittingdevicedesignedtobeusedin otherthanfixedlocationsandtogenerallybeusedinsuchawaythataseparationdistanceofatleast20 centimetersisnormallymaintainedbetweenthetransmitter’sradiatingstructure(s)andthebodyoftheuser ornearbypersons. FCCKDB447498D01GeneralRFExposureGuidancev05r02Limit Devicesoperatinginstandalonemobileexposureconditionsmaycontainasingletransmitterormultiple transmittersthatdonottransmitsimultaneously.Aminimumtestseparationdistance≥20cmisrequired betweentheantennaandradiatingstructuresofthedeviceandnearbypersonstoapplymobiledevice exposurelimits.Thedistancemustbefullysupportedbytheoperatingandinstallationconfigurationsofthe transmitteranditsantenna(s),accordingtothesource-basedtime-averagedmaximumpowerrequirements of§2.1091(d)(2).Incaseswherecablelossesorotherattenuationsareappliedtodeterminecompliance, themostconservativeoperatingconfigurationsandexposureconditionsmustbeevaluated.Theminimum testseparationdistancerequiredforadevicetocomplywithmobileexposureconditionsmustbeclearly identifiedintheinstallationandoperatinginstructions,forallinstallationandexposureconditions,toenable usersandinstallerstocomplywithRFexposurerequirements.Formobiledevicesthathavethepotentialto operateinportabledeviceexposureconditions,similartotheconfigurationsdescribedin§2.1091(d)(4),a KDBinquiryisrequiredtodeterminetheSARtestrequirementsfordemonstratingcompliance. Whenthecategoricalexclusionprovisionof§2.1091(c)applies,theminimumtestseparationdistancemay beestimated,whenapplicable,bysimplecalculationsaccordingtoplane-waveequivalentconditions,to ensurethetransmitteranditsantenna(s)canoperateinmannersthatmeetorexceedtheestimateddistance. Thesource-basedtime-averagedmaximumradiatedpower,accordingtothemaximumantennagain,mustbe appliedtocalculatethefieldstrengthandpowerdensityrequiredtoestablishtheminimumtestseparation distance.Whentheestimatedtestseparationdistancebecomesoverlyconservativeanddoesnotsupport compliance,MPEmeasurementorcomputationalmodelingmaybeusedtodeterminetherequiredminimum separationdistance. RFExposureEvaluationResult: FCC(Worstcase) AccordingtoFCCPart1.1307,systemsoperatingundertheprovisionsofthissectionshallbeoperatedina mannertheensuresthatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe commission’sguidelines. LimitsforGeneralPopulation/UncontrolledExposure FrequencyRange (MHz) ElectricField Strength(E)(V/m) MagneticFieldStrength (H)(A/m) PowerDensity (S)(mW/cm2) 0.3-1.346141.63(100)* 1.34-30824/f2.19/f(180/f2)* 30-30027.50.0730.2 300-1500f/1500 1500-100,0001.0 MPEcalculationformula Where: S=powerdensity P=outputpower(W) G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=Separationdistancebetweenradiatorandhumanbody(m) Testresult Maximumpeakoutputpoweratantennainputterminal(dBm):8.71 Maximumpeakoutputpoweratantennainputterminal(mW):7.43 Predictiondistance(cm):20 Predicationfrequency(MHz):2402 AntennaGain(typical)(dBi):0 Powerdensityatpredicationfrequencyat20cm(mW/cm2):0.00148 MPElimitforRFexposureatpredictionfrequency(mW/cm2):1 FCCVerdict:PASS Note: 1.MorepowerlistpleaserefertoRFtestreport.

Test Report

Report No.: BL-SZ1540120-601 2 Revision History Version Issue Date Revisions Rev. 01 May. 21, 2015 Initial Issue TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) ........................................................................ 5 1.1 Identification of the Testing Laboratory ............................................................................................ 5 1.2 Identification of the Responsible Testing Location ........................................................................... 5 1.3 Announce ........................................................................................................................................ 5 2 PRODUCT INFORMATION ................................................................................................................... 6 2.1 Applicant ......................................................................................................................................... 6 2.2 Manufacturer ................................................................................................................................... 6 2.3 General Description for Equipment under Test (EUT) ..................................................................... 6 2.4 Technical Information ...................................................................................................................... 6 2.5 Ancillary Equipment ......................................................................................................................... 7 3 SUMMARY OF TEST RESULTS ........................................................................................................... 8 3.1 Test Standards ................................................................................................................................ 8 3.2 Verdict ............................................................................................................................................. 8 4 GENERAL TEST CONFIGURATIONS .................................................................................................. 9 4.1 Test Environments .......................................................................................................................... 9 4.2 Test Equipment List ......................................................................................................................... 9 4.3 Test Configurations ....................................................................................................................... 10 4.4 Description of Test Setup .............................................................................................................. 10 4.4.1 For Antenna Port Test ............................................................................................................ 10 4.4.2 For AC Power Supply Port Test .............................................................................................. 11 4.4.3 For Radiated Test (Below 30 MHz) ......................................................................................... 11 4.4.4 For Radiated Test (30 MHz- 1 GHz) ........................................................................................ 12 4.4.5 For Radiated Test (Above 1 GHz) .......................................................................................... 12 4.5 Test Conditions ............................................................................................................................. 13 Report No.: BL-SZ1540120-601 3 4.6 Measurement Results Explanation Example ................................................................................. 14 4.6.1 For conducted test items: ....................................................................................................... 14 4.6.2 For radiated band edges and spurious emission test: ............................................................. 14 5 TEST ITEMS ....................................................................................................................................... 15 5.1 Antenna Requirements .................................................................................................................. 15 5.1.1 Standard Applicable ............................................................................................................... 15 5.1.2 Antenna Anti-Replacement Construction ................................................................................ 15 5.1.3 Antenna Gain ......................................................................................................................... 15 5.2 Number of Hopping Frequency ..................................................................................................... 16 5.2.1 Limit ........................................................................................................................................ 16 5.2.2 Test Procedure ....................................................................................................................... 16 5.3 Peak Output Power ....................................................................................................................... 17 5.3.1 Test Limit ................................................................................................................................ 17 5.3.2 Test Procedure ....................................................................................................................... 17 5.4 Occupied Bandwidth ..................................................................................................................... 18 5.4.1 Limit ........................................................................................................................................ 18 5.4.2 Test Procedure ....................................................................................................................... 18 5.5 Carr ier Frequency Separation .....…

Text truncated - open the document above for the full version.

Test Setup Photos

ANNEX B TEST SETUP PHOTOS B.1 Conducted Test Photo B.2 Conducted Emissions Test Photo B.3 Radiated Test Photo Below 30 MHz 30 MHz to 1 GHz Above 1 GHz

Contact Information

Applicant

XIANG DONG(Sales Manager)
[email protected]86-755-28744138Fax: 86-755-28750222

Test Firm

Shenzhen BALUN Technology Co.,Ltd.Xuewen Wu
[email protected]86-755-66833404Fax: 86-755-61824271

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz7.43 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Tonika Electronics Technology (Shenzhen) Co., Ltd.

Bluetooth Speaker - FCC ID SDNTA-320B-01 - Tonika Electronics Technology (Shenzhen) Co., Ltd.
SDNTA-320B-01

Bluetooth Speaker

Sep 08, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker - FCC ID SDNTA-304DG-01 - Tonika Electronics Technology (Shenzhen) Co., Ltd.
SDNTA-304DG-01

Bluetooth Speaker

Aug 20, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker - FCC ID SDNTA-483-01 - Tonika Electronics Technology (Shenzhen) Co., Ltd.
SDNTA-483-01

Bluetooth Speaker

Aug 09, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLUETOOTH WIRELESS TECHNOLOGY SPEAKER - FCC ID SDNTA-479-01 - Tonika Electronics Technology (Shenzhen) Co., Ltd.
SDNTA-479-01

BLUETOOTH WIRELESS TECHNOLOGY SPEAKER

Jul 20, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker - FCC ID SDNB061231 - Tonika Electronics Technology (Shenzhen) Co., Ltd.
SDNB061231

Bluetooth Speaker

Dec 08, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter