Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
A73x addWAVE User Guide Valid for A731, A732, A733 and A733GSM RTUs Release 2.0 and higher Rel. 2.3 / September 2006 ADCON TELEMETRY GmbH INKUSTRASSE 24 A-3400 KLOSTERNEUBURG AUSTRIA TEL: +43-2243-38280-0 FAX: +43-2243-38280-6 http://www.adcon.at e-mail: [email protected] ADCON INTERNATIONAL INC 2050 LYNDELL TERRACE SUITE 129, DAVIS, 95616 CALIFORNIA, USA TEL: +1 (530) 753 1458 FAX: +1 (530) 753 1054 http://www.adcon.at email: [email protected] Proprietary Notice: The Adcon logo, the A720 series and addIT™, the A730 series and addWAVE, addVANTAGE and AgroExpert™ are trademarks or registered trademarks of Adcon Telemetry GmbH. All other registered names used throughout this publication are trademarks of their respective owners. This publication contains confidential information that is the property of Adcon Telemetry GmbH. Disclosure to third parties of the information contained herein is prohibited. Neither the whole nor any part of the information contained in this publication may be reproduced in any material form except with the prior written permission of Adcon Telemetry GmbH. Release 2.2 / August 2006 Copyright © 2006 by Adcon Telemetry GmbH. All rights reserved. Table of Contents Table of Contents 1 Introduction.........................................................................7 1.1 About the A73x RTU family..............................................................7 1.2 Compliance Statement and Warnings.............................................8 1.3 Conventions.....................................................................................8 2 Using the A73x RTU..........................................................11 2.1 Opening the packages...................................................................11 2.2 Installing the RTU...........................................................................12 2.3 Special notes for the A733GSM/GPRS RTU.................................13 2.3.1 GPRS usage of an A733GSM/GPRS RTU....................................15 2.4 Field Installation.............................................................................17 2.5 More about the LED tool................................................................19 2.6 Configuring an A73x RTU in the addVANTAGE software..........................................................................................20 2.7 Maintaining and servicing the RTU................................................20 2.7.1 The RTU battery.............................................................................20 2.7.2 Changing the battery......................................................................21 3 Performing Advanced Functions.....................................25 3.1 Understanding connectors.............................................................25 3.1.1 The RTU connectors......................................................................25 3.1.2 The POWER Connector.................................................................26 3.2 Communicating with the RTU........................................................27 3.3 Serial communication protocol.......................................................28 3.3.1 General format of a command.......................................................28 3.3.2 General format of an answer.........................................................28 3.4 Using terminal commands.............................................................29 CMDS.............................................................................................29 3 Table of Contents TIME...............................................................................................29 FREQ.............................................................................................29 RSSI...............................................................................................30 ID....................................................................................................30 SLOT..............................................................................................31 SST................................................................................................31 PMP...............................................................................................31 ANLG.............................................................................................32 ANRT.............................................................................................35 DATA..............................................................................................36 IMME..............................................................................................38 FDEV..............................................................................................38 INFO...............................................................................................39 PORT.............................................................................................40 RX..................................................................................................43 TX...................................................................................................43 B .....................................................................................................44 BLST..............................................................................................44 VER................................................................................................44 SDI.................................................................................................45 DATASDI........................................................................................46 SDA................................................................................................48 FPC................................................................................................48 GSMPIN..............................................................................…
Text truncated - open the document above for the full version.
Coverletter: Adcon Telemetry GmbH wants to get FCC-Certification for the following product: Telemetry transceiver using GSM technology in the Cellular Radiotelephony Service and the broadband PCS Band (FCC Part 22 and 24) A733-GSM-GPRS The unit will get the following FCC-ID: SHXA733GSM-GPRS List of documents: Exhibit Thema File Exhibit 01 Label and placement Label_Placement_A733GSM_GPRS_Tuev1.0.pdf Exhibit 02 Not needed -------------------- Exhibit 03 External Photos Extern_A733GSM_GPRS_Tuev1.0.pdf * Exhibit 04 Block Diagrams Blockdiagram.jpg * Exhibit 05 Schematic Diagrams Schematics_Part1_A733GSM_GPRS_Tuev1.0-2.pdf Schematics_Part2_A733GSM_GPRS_Tuev1.0-2.pdf Exhibit 06 Testreport 06-129_Part1.pdf 06-129_Part2.pdf attachments_06-129.pdf Exhibit 07 Test Set-up Photos setup_06-129.pdf Exhibit 08 User Manual A733_UserGuide_English_V23_GPRS.pdf Exhibit 09 Internal Photos Inside_A733GSM_GPRS_Tuev1.0.pdf *Exhibit 10 Tune-up Info, Parts list A733GSM-GPRS_Tune_Up_Procedure.doc Parts_List_A733GSM_GPRS_Tuev1.0-3.pdf Exhibit 11 RF exposure issues RF exposure compliance issues.doc *Exhibit 12 Operational Description Description_A733GSM_GPRS_Tuev1.0.pdf Software_A733GSM_GPRS_Tuev1.0.pdf Exhibit 13 Cover letter Request for confidentiality This file FCCConfidentiality.doc For the Exhibits marked with ‘*’ Adcon Telemetry GmbH requested Confidentiality according to 47 CFR 0.457 and 0.459 of the FCC rules because these are sensitive parts owned by this company and include much of Know-How or sensitive data, it will not be provided to the public. The labelling on some photos may not be the actual status. The correct labelling you can see in Exhibit 1.
Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 U.S.A. Klosterneuburg, Nov. 27, 2006 Confidentiality Request Our FRN: 0011471562 Our FCC Code 1: SHX TO WHOM IT MAY CONCERN Pursuant to Paragraphs 0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Adcon Telemetry GmbH requests confidentiality for the following product: FCC ID Number Title/Model SHXA733GSM-GPRS A733 addWAVE GSM/GPRS For the product stated above we request that the following information be held confidential: 1. Block Diagram, circuit diagrams, BOM and PCBs submitted as Chapter 2 of the attached “A733GSM-GPRS RTU Technical Reference Manual Quad Band Model”. 2. Software control commandset submitted as Chapter 3.3 of the attached “A733GSM-GPRS Technical Reference Manual Quad Band Model”. The above exhibits contain Adcon Telemetry GmbH trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our wireless data logger. This material is not customarily available to the general public and we request that it be withheld from public inspection. For any and all questions please feel free to contact me at the address shown in the letterhead or under my personal email address [email protected] Sincerely, Bernhard Pacher CEO
CHAPTER2.HARDWARE2.6.A733GSM-GPRSDEVICE'SPHOTOGRAPHS Figure 2.9:A733GSM-GPRS,Frontview. Figure 2.10:A733GSM-GPRS,Backview. 19 2.6.A733GSM-GPRSDEVICE'SPHOTOGRAPHSCHAPTER2.HARDWARE Figure 2.11:A733GSM-GPRS,Topview. Figure 2.12:A733GSM-GPRS,Bottomview. 20
CHAPTER2.HARDWARE2.6.A733GSM-GPRSDEVICE'SPHOTOGRAPHS Figure 2.13:A733GSM-GPRS,Leftview. Figure 2.14:A733GSM-GPRS,Rightview. 21
2.6.A733GSM-GPRSDEVICE'SPHOTOGRAPHSCHAPTER2.HARDWARE Figure 2.15:A733GSM-GPRS,Caseopened. Figure 2.16:A733GSM-GPRSMotherboard,topview. Figure 2.17:A733GSM-GPRSMotherboard,bottomview. 22
RF exposure compliance issues: This telemetry device is normally used only at fixed locations far away from persons. It is collecting data from various sensors and transmitting it through the GSM network. According to OET Bulletin 65 for fixed transmitters operating in the Cellular Radiotelephone Service band or in the broadband PCS band evaluation is not required when the total power of all channels used is below or equal to 1000 W ERP or 2000 W ERP respectively. This device only uses one channel in the Cellular Radiotelephone Service band at 850 MHz with a maximum power output of 2 Watts, and ERP not exceeding 7 Watts or one channel in the PCS 1900 MHz Band with a maximum power output of 1 Watt, and ERP not exceeding 2 Watts. So this device is excluded from routine evaluation. It must be operated only as fixed device, never should be used as mobile or portable device.
Inkustr. 24 · Klosterneuburg · Austria
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 1 W | 243KGXW | 0.1 ppm |

telemetry transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Telemetry transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Telemetry transceiver
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Telemetry GSM/GPRS Transceiver
Equipment Class
PCB - PCS Licensed Transmitter
Telemetry GSM/GPRS Transceiver
Equipment Class
PCB - PCS Licensed Transmitter