FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nanotron Technologies GmbH/
  3. SIFCMCBASE0108V2

SIFCMCBASE0108V2CMC TC BS - Wireless Sensor Network

Nanotron Technologies GmbH
CMC TC BS - Wireless Sensor Network - FCC ID SIFCMCBASE0108V2 - Nanotron Technologies GmbH
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 17, 2008
Application Purpose
Original Equipment
Date of Application
Apr 16, 2008
Equipment Note
CMC TC BS - Wireless Sensor Network
Frequency Range
2441.75000000 - 2441.75000000
Company
Nanotron Technologies GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Required Exhibit 12 CMC-TC Wireless I/O-Unit DK 7320.240 User Manual (UserMan) Version 1.01 NA-08-0000-0025-1.01 Document Information CMC-TC Wireless I/O-Unit (UserMan) Page ii NA-08-0000-0025-1.01 © 2008 Nanotron Technologies GmbH. Document Information Document Title: CMC-TC Wireless I/O-Unit (UserMan) Document Version: 1.01 Published (yyyy-mm-dd): 2008-04-17 Current Printing:2008-4-17, 1:39 pm Document ID: NA-08-0000-0025-1.01 Document Status: Released Disclaimer Nanotron Technologies GmbH believes the information contained herein is correct and accurate at the time of release. Nanotron Technologies GmbH reserves the right to make changes without further notice to the product to improve reliability, function or design. Nanotron Technologies GmbH does not assume any liability or responsibility arising out of this product, as well as any application or circuits described herein, neither does it convey any license under its patent rights. As far as possible, significant changes to product specifications and functionality will be provided in product specific Errata sheets, or in new versions of this document. Customers are encouraged to check the Nanotron website for the most recent updates on products. Trademarks nanoNET © is a registered trademark of Nanotron Technologies GmbH. All other trademarks, registered trademarks, and product names are the sole property of their respective owners. This document and the information contained herein is the subject of copyright and intellectual property rights under international convention. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical or optical, in whole or in part, without the prior written permission of Nanotron Technologies GmbH. Copyright © 2008 Nanotron Technologies GmbH. Life Support Policy These products are not designed for use in life support appli- ances, devices, or systems where malfunction of these prod- ucts can reasonably be expected to result in personal injury. Nanotron Technologies GmbH customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Nanotron Technologies GmbH for any damages resulting from such improper use or sale. Electromagnetic Interference / Compatibility Nearly every electronic device is susceptible to electromag- netic interference (EMI) if inadequately shielded, designed, or otherwise configured for electromagnetic compatibility. To avoid electromagnetic interference and/or compatibility conflicts, do not use this device in any facility where posted notices instruct you to do so. In aircraft, use of any radio fre- quency devices must be in accordance with applicable regula- tions. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy. With medical devices, maintain a minimum separation of 15 cm (6 inches) between pacemakers and wireless devices and some wireless radios may interfere with some hearing aids. If other personal medical devices are being used in the vicinity of wireless devices, ensure that the device has been ade- quately shielded from RF energy. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CAUTION! Electrostatic Sensitive Device. Pre- caution should be used when handling the device in order to prevent permanent damage. FCC User Information Statement according to FCC part 15.19: This device complies with Part 15 of the FCC Rules. Opera- tion is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. RF exposure mobil: The internal / external antennas used for this mobile transmit- ter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in con- junction with any other antenna or transmitter." Statement according to FCC part 15.105: This equipment has been tested and found to comply with the limits for a Class A and Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi- dential installation and against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency energy and, if not installed and used in accordance with the instructions as provided in the user manual, may cause harmful interference to radio communications. How- ever, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a resi- dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to connected. •Consult the dealer or an experienced technician for help. ENCMC-TC Wireless I/O-Unit DK 7320.240 Assembly, Installation and Operation A38148 09 IT 74 US Representative Rittal Corporation One Rittal Place Springfield, OH 45504 Telefon: +1(937)399 05 00 Fax: +1(937)390 55 99 eMail: [email protected] Website: www.rittal-corp.com Published: 17/04/2008 Microsoft Windows is a registered trademark of Microsoft Corporation. …

Text truncated - open the document above for the full version.

Cover Letter(s)

11.04.2008 Request for Confidentiality Nanotron Technologies GmbH FCC ID: SIFCMCBASE0108V2 FCC Part 15 Certification Gentlemen, In accordance with 0.459 of CFR 47, Nanotron Technologies GmbH hereby requests confidentiality of all block diagrams, circuit description, circuit diagrams, parts list, operational description attachments for the subject application. These documents contain detailed system and equipment description and related information about the product which Nanotron Technologies considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, Nanotron considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, Dr. F. Schlichting Director Application Engineering Nanotron Technologies GmbH Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Telefon +49 30 399 954 - 0 Fax +49 30 399 954 - 188 E-Mail [email protected] Web www.nanotron.com GeschäftsfĂĽhrer Dr. Jens N. Albers Zbigniew Ianelli Bankverbindung Deutsche Bank BLZ 10070000 Konto 703 777 3 Amtsgericht Berlin-Charlottenburg Abteilung B – Register Nr. 42 324 USt-IdNr. DE 136 768 686 Nanotron Technologies GmbH Alt-Moabit 60 10555 Berlin Germany

Cover Letter(s)

11.04.2008 To whom it may concern: We, the undersigned, hereby authorize Eurofins ETS Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization CMC-TC Base Station including the signing of all documents relating to these matters. Any and all acts carried out by Eurofins ETS Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Dr. F. Schlichting Director Application Engineering Nanotron Technologies GmbH Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Telefon +49 30 399 954 - 0 Fax +49 30 399 954 - 188 E-Mail [email protected] Web www.nanotron.com GeschäftsfĂĽhrer Dr. Jens N. Albers Zbigniew Ianelli Bankverbindung Deutsche Bank BLZ 10070000 Konto 703 777 3 Amtsgericht Berlin-Charlottenburg Abteilung B – Register Nr. 42 324 USt-IdNr. DE 136 768 686 Nanotron Technologies GmbH Alt-Moabit 60 10555 Berlin Germany

External Photos

Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 10 Appendix A. Pictures Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 2 of 10 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 10 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 10

ID Label/Location Info

FCC Required Exhibit 4 CMC-TC Wireless I/O-Unit DK 7320.240 Label Location (LabelLoc) Version 1.01 NA-08-0000-0029-1.01 Document Information CMC-TC Wireless I/O-Unit Label Location (LabelLoc) Page ii NA-08-0000-0029-1.01 © 2008 Nanotron Technologies GmbH. Document Information Document Title: CMC-TC Wireless I/O-Unit Label Location (LabelLoc) Document Version: 1.01 Published (yyyy-mm-dd): 2008-04-17 Current Printing:2008-4-17, 1:20 pm Document ID: NA-08-0000-0029-1.01 Document Status: Released Disclaimer Nanotron Technologies GmbH believes the information contained herein is correct and accurate at the time of release. Nanotron Technologies GmbH reserves the right to make changes without further notice to the product to improve reliability, function or design. Nanotron Technologies GmbH does not assume any liability or responsibility arising out of this product, as well as any application or circuits described herein, neither does it convey any license under its patent rights. As far as possible, significant changes to product specifications and functionality will be provided in product specific Errata sheets, or in new versions of this document. Customers are encouraged to check the Nanotron website for the most recent updates on products. Trademarks nanoNET © is a registered trademark of Nanotron Technologies GmbH. All other trademarks, registered trademarks, and product names are the sole property of their respective owners. This document and the information contained herein is the subject of copyright and intellectual property rights under international convention. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical or optical, in whole or in part, without the prior written permission of Nanotron Technologies GmbH. Copyright © 2008 Nanotron Technologies GmbH. Life Support Policy These products are not designed for use in life support appli- ances, devices, or systems where malfunction of these prod- ucts can reasonably be expected to result in personal injury. Nanotron Technologies GmbH customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Nanotron Technologies GmbH for any damages resulting from such improper use or sale. Electromagnetic Interference / Compatibility Nearly every electronic device is susceptible to electromag- netic interference (EMI) if inadequately shielded, designed, or otherwise configured for electromagnetic compatibility. To avoid electromagnetic interference and/or compatibility conflicts, do not use this device in any facility where posted notices instruct you to do so. In aircraft, use of any radio fre- quency devices must be in accordance with applicable regula- tions. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy. With medical devices, maintain a minimum separation of 15 cm (6 inches) between pacemakers and wireless devices and some wireless radios may interfere with some hearing aids. If other personal medical devices are being used in the vicinity of wireless devices, ensure that the device has been ade- quately shielded from RF energy. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CAUTION! Electrostatic Sensitive Device. Pre- caution should be used when handling the device in order to prevent permanent damage. FCC User Information Statement according to FCC part 15.19: This device complies with Part 15 of the FCC Rules. Opera- tion is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. RF exposure mobil: The internal / external antennas used for this mobile transmit- ter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in con- junction with any other antenna or transmitter." Statement according to FCC part 15.105: This equipment has been tested and found to comply with the limits for a Class A and Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi- dential installation and against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency energy and, if not installed and used in accordance with the instructions as provided in the user manual, may cause harmful interference to radio communications. How- ever, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a resi- dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to connected. •Consult the dealer or an experienced technician for help. Label Location CMC-TC Wireless I/O-Unit Label Location (LabelLoc) © 2008 Nanotron Technologies GmbH.NA-08-0000-0029-1.01 Page 1 1 1 Label Location Figure 1: Label Location Label Location Label Location CMC-TC Wireless I/O-Unit Label Location (LabelLoc) Page 2 NA-08-0000-0029-1.01© 2008 Nanotron Technologies GmbH. 1 Intentionally L…

Text truncated - open the document above for the full version.

ID Label/Location Info

FCC Required Exhibit 3 CMC-TC Wireless I/O-Unit DK 7320.240 Label Sample (LabelSmpl) Version 1.01 NA-08-0000-0030-1.01 Document Information CMC-TC Wireless I/O-Unit Label Sample (LabelSmpl) Page ii NA-08-0000-0030-1.01 © 2008 Nanotron Technologies GmbH. Document Information Document Title: CMC-TC Wireless I/O-Unit Label Sample (LabelSmpl) Document Version: 1.01 Published (yyyy-mm-dd): 2008-04-17 Current Printing:2008-4-17, 1:23 pm Document ID: NA-08-0000-0030-1.01 Document Status: Released Disclaimer Nanotron Technologies GmbH believes the information contained herein is correct and accurate at the time of release. Nanotron Technologies GmbH reserves the right to make changes without further notice to the product to improve reliability, function or design. Nanotron Technologies GmbH does not assume any liability or responsibility arising out of this product, as well as any application or circuits described herein, neither does it convey any license under its patent rights. As far as possible, significant changes to product specifications and functionality will be provided in product specific Errata sheets, or in new versions of this document. Customers are encouraged to check the Nanotron website for the most recent updates on products. Trademarks nanoNET © is a registered trademark of Nanotron Technologies GmbH. All other trademarks, registered trademarks, and product names are the sole property of their respective owners. This document and the information contained herein is the subject of copyright and intellectual property rights under international convention. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical or optical, in whole or in part, without the prior written permission of Nanotron Technologies GmbH. Copyright © 2008 Nanotron Technologies GmbH. Life Support Policy These products are not designed for use in life support appli- ances, devices, or systems where malfunction of these prod- ucts can reasonably be expected to result in personal injury. Nanotron Technologies GmbH customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Nanotron Technologies GmbH for any damages resulting from such improper use or sale. Electromagnetic Interference / Compatibility Nearly every electronic device is susceptible to electromag- netic interference (EMI) if inadequately shielded, designed, or otherwise configured for electromagnetic compatibility. To avoid electromagnetic interference and/or compatibility conflicts, do not use this device in any facility where posted notices instruct you to do so. In aircraft, use of any radio fre- quency devices must be in accordance with applicable regula- tions. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy. With medical devices, maintain a minimum separation of 15 cm (6 inches) between pacemakers and wireless devices and some wireless radios may interfere with some hearing aids. If other personal medical devices are being used in the vicinity of wireless devices, ensure that the device has been ade- quately shielded from RF energy. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CAUTION! Electrostatic Sensitive Device. Pre- caution should be used when handling the device in order to prevent permanent damage. FCC User Information Statement according to FCC part 15.19: This device complies with Part 15 of the FCC Rules. Opera- tion is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. RF exposure mobil: The internal / external antennas used for this mobile transmit- ter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in con- junction with any other antenna or transmitter." Statement according to FCC part 15.105: This equipment has been tested and found to comply with the limits for a Class A and Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi- dential installation and against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency energy and, if not installed and used in accordance with the instructions as provided in the user manual, may cause harmful interference to radio communications. How- ever, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a resi- dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to connected. •Consult the dealer or an experienced technician for help. Label Sample CMC-TC Wireless I/O-Unit Label Sample (LabelSmpl) © 2008 Nanotron Technologies GmbH.NA-08-0000-0030-1.01 Page 1 1 1 Label Sample Figure 1: Label Sample Figure 2: Label Sample - FCC Certification Font type: Helvetica Font Size: 2 mm Font type: Kabel Bold Font Size: 3.5 mm Font type: Helvetica Bold Font Size: 3.0 mm Font t…

Text truncated - open the document above for the full version.

Internal Photos

Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 10 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 10 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 10

Operational Description

FCC Required Exhibit 17 CMC-TC Wireless I/O-Unit Antenna Specification (AntSpec) Version 1.00 NA-08-0000-0028-1.00 Document Information CMC-TC Wireless I/O-Unit Antenna Specifications (AntSpec) Page ii NA-08-0000-0028-1.00 © 2008 Nanotron Technologies GmbH. Document Information Document Title: CMC-TC Wireless I/O-Unit Antenna Specifications (AntSpec) Document Version: 1.00 Published (yyyy-mm-dd): 2008-04-15 Current Printing:2008-4-15, 4:44 pm Document ID: NA-08-0000-0028-1.00 Document Status: Released Disclaimer Nanotron Technologies GmbH believes the information contained herein is correct and accurate at the time of release. Nanotron Technologies GmbH reserves the right to make changes without further notice to the product to improve reliability, function or design. Nanotron Technologies GmbH does not assume any liability or responsibility arising out of this product, as well as any application or circuits described herein, neither does it convey any license under its patent rights. As far as possible, significant changes to product specifications and functionality will be provided in product specific Errata sheets, or in new versions of this document. Customers are encouraged to check the Nanotron website for the most recent updates on products. Trademarks nanoNET © is a registered trademark of Nanotron Technologies GmbH. All other trademarks, registered trademarks, and product names are the sole property of their respective owners. This document and the information contained herein is the subject of copyright and intellectual property rights under international convention. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical or optical, in whole or in part, without the prior written permission of Nanotron Technologies GmbH. Copyright © 2008 Nanotron Technologies GmbH. Life Support Policy These products are not designed for use in life support appli- ances, devices, or systems where malfunction of these prod- ucts can reasonably be expected to result in personal injury. Nanotron Technologies GmbH customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Nanotron Technologies GmbH for any damages resulting from such improper use or sale. Electromagnetic Interference / Compatibility Nearly every electronic device is susceptible to electromag- netic interference (EMI) if inadequately shielded, designed, or otherwise configured for electromagnetic compatibility. To avoid electromagnetic interference and/or compatibility conflicts, do not use this device in any facility where posted notices instruct you to do so. In aircraft, use of any radio fre- quency devices must be in accordance with applicable regula- tions. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy. With medical devices, maintain a minimum separation of 15 cm (6 inches) between pacemakers and wireless devices and some wireless radios may interfere with some hearing aids. If other personal medical devices are being used in the vicinity of wireless devices, ensure that the device has been ade- quately shielded from RF energy. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CAUTION! Electrostatic Sensitive Device. Pre- caution should be used when handling the device in order to prevent permanent damage. FCC User Information Statement according to FCC part 15.19: This device complies with Part 15 of the FCC Rules. Opera- tion is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. RF exposure mobil: The internal / external antennas used for this mobile transmit- ter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in con- junction with any other antenna or transmitter." Statement according to FCC part 15.105: This equipment has been tested and found to comply with the limits for a Class A and Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi- dential installation and against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency energy and, if not installed and used in accordance with the instructions as provided in the user manual, may cause harmful interference to radio communications. How- ever, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a resi- dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to connected. •Consult the dealer or an experienced technician for help. Antenna Specifications for Model IW-144 CMC-TC Wireless I/O-Unit Antenna Specifications (AntSpec) © 2008 Nanotron Technologies GmbH.NA-08-0000-0028-1.00 Page 1 1 1 Antenna Specifications for Model IW-144 This section provides the specifications for the antenna model IW-144 used by the CMC-TC Wire- less I/O-Unit DK 7320.24…

Text truncated - open the document above for the full version.

Test Report

EUROFINS ETS PRODUCT SERVICE GMBH TEST - REPORT FCC RULES PARTS 15.247 IC RADIO STANDARDS RSS-210 - Issue 7 FCC ID: SIFCMCBASE0108V2 Model Name: Base Station - V2 Test report no.:G0M20801-1627-C-1 Certificate #1983.01 Eurofins ETS Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888 0 Germany Fax +49-33631-888 660 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 29 TABLE OF CONTENTS 1 General information 2 1.1 Notes 2 1.2 Testing laboratory 3 1.3 Details of approval holder 4 1.4 Application details 4 1.5 Test item 4 1.6 Test standards 6 2 Technical test 6 2.1 Summary of test results 6 2.2 Test environment 6 2.3 Test equipment utilized 7 2.4 Test Procedure 17 3 Test results 18 3.1 Transmitter parameters 19 3.1.1 RF power output, conducted 19 3.1.2 RF power output, radiated (EIRP) 20 3.1.3 6 db bandwidth; Occupied bandwidth (99% BW) 21 3.1.4 Peak power spectral density 22 3.1.5 Spurious emissions, conducted 23 3.1.6 Spurious emissions, radiated 24 3.1.7 AC power line conducted emissions 27 3.2 Receiver parameters 28 3.2.1 Spurious emissions 28 APPENDIX 29 Test Report No.: G0M20801-1627-C-1 Eurofins ETS Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 2 of 29 1 General information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the the Eurofins ETS Product Service GmbH. …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Gareth Liam Williams(QA Engineer)
[email protected]4917628701874Fax: 4930399954188

Technical Contact

Nanotron Technologies GmbHFrank Schlichting
[email protected]+49 30 399954-202

Alt-Moabit 60 · Berlin · Germany

Non-Technical Contact

Nanotron Technologies GmbHFrank Schlichting
[email protected]+49 30 399954-202

Test Firm

Eurofins Product Service GmbHMichael Howard
[email protected]49-33631-888-300Fax: 49-33631-888-650

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.44 GHz - 2.44 GHz58.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The external antenna used for this mobile transmitter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Nanotron Technologies GmbH

Radio Anchor that localises transmitters - FCC ID SIFANQ03QCS - Nanotron Technologies GmbH
SIFANQ03QCS

Radio Anchor that localises transmitters

Sep 18, 2023

Equipment Class

DTS - Digital Transmission System
RF Tag that is attached to objects and localises them using radio broadcasts - FCC ID SIFASSETTAG - Nanotron Technologies GmbH
SIFASSETTAG

RF Tag that is attached to objects and localises them using radio broadcasts

Sep 18, 2023

Equipment Class

DTS - Digital Transmission System
CMC TC SD - Wireless Sensor Network - FCC ID SIFCMCSENS0108V2 - Nanotron Technologies GmbH
SIFCMCSENS0108V2

CMC TC SD - Wireless Sensor Network

Apr 17, 2008

Equipment Class

DTS - Digital Transmission System
nanoNET TRX 2.4 GHz CSS Transceiver - FCC ID SIFNANONET-TRX - Nanotron Technologies GmbH
SIFNANONET-TRX

nanoNET TRX 2.4 GHz CSS Transceiver

Jan 20, 2005

Equipment Class

DTS - Digital Transmission System