To receive further information, please contact OMNIKEY E-Mail: [email protected] or visit our homepage www.omnikey.com CardMan Æ 5121 Userís Guide - Draft - Oct 2004 Subject to change without notice Copyright © 2004 by OMNIKEY RFID Smart Card Reader Technology CardMan Æ 5121 Userís DRAFT This guide describes how to use CardMan 5121 with Windows 98, ME, 2000 or XP for working with contactless or contact smart cards. To install your CardMan 5121 please follow the steps as described in the ìCardMan 5121 Install Guideî If you are developing applications for contactless cards please refer to the ìCardMan 5121 Developerís Guideî for detailed informations about programming the CardMan 5121 and the respective middleware. To receive further information, please contact OMNIKEY E-Mail: [email protected] or visit our homepage www.omnikey.com CardMan Æ 5121 Userís Guide - Draft - Oct 2004 Subject to change without notice Copyright © 2004 by OMNIKEY RFID Smart Card Reader Technology CardMan Æ 5121 Userís DRAFT Diagnostic Tool - Testing your CardMan 5121 After finishing the installation of the OMNIKEY CardMan 5121 driver, you will find a diagnostic tool icon in your Control Panel. Double-click the icon to start the tool. In addition to the ìGeneralî tab sheet, you should see an OMNIKEY CardMan 5121 sheet. Clicking it, you see the status of your reader. Hold a contactless smart card near the OMNIKEY logo on the top side of the housing. You should now see the name of the card and the serial number. The bottom line shows the protocol T=CL (contactless). When inserting a contact smart card in the readerís slot, you see the ATR of the card and the protocol for contact communication (T=0, T=1, synchronous ñ depending on the card). To receive further information, please contact OMNIKEY E-Mail: [email protected] or visit our homepage www.omnikey.com CardMan Æ 5121 Userís Guide - Draft - Oct 2004 Subject to change without notice Copyright © 2004 by OMNIKEY RFID Smart Card Reader Technology CardMan Æ 5121 Userís DRAFT Handling To receive further information, please contact OMNIKEY E-Mail: [email protected] or visit our homepage www.omnikey.com CardMan Æ 5121 Userís Guide - Draft - Oct 2004 Subject to change without notice Copyright © 2004 by OMNIKEY RFID Smart Card Reader Technology CardMan Æ 5121 Userís DRAFT Functional description CardMan 5121 is a device to communicate with contactless smartcards using a radio field at a frequency of 13.56 MHz. The radio communication is translated into wired signals and sent to the connected PC over the USB interface. Ö To receive further information, please contact OMNIKEY E-Mail: [email protected] or visit our homepage www.omnikey.com CardMan Æ 5121 Userís Guide - Draft - Oct 2004 Subject to change without notice Copyright © 2004 by OMNIKEY RFID Smart Card Reader Technology CardMan Æ 5121 Userís DRAFT Conformance Informations FCC: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. CANADA: Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Request for Confidentiality Date: 14 September 2004 PHOENIX TEST-LAB GmbH Königswinkel 10 D32825 Blomberg Germany RE: Certification Application FCC ID: SIYCM5121 Please be advised that the following information is to be held confidential on behalf of Omnikey AG: • Schematics • Parts Lists • Block Diagram • Technical Description The application contains technical information which Omnikey AG deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.
FCC ID SIYCM5121 FCC ID SIYCM5121 FCC ID SIYCM5121 FCC ID SIYCM5121 FCC ID SIYCM5121 FCC ID SIYCM5121
FCC ID SIYCM5121 FCC ID SIYCM5121 FCC ID SIYCM5121
EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 1 of 37 Pages Straubing, 30 August 2004 T E S T - R E P O R T No. 51514-40562 for CardMan 5121 RFID Reader 13.56 MHz Applicant: Omnikey AG Test Specification: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207, 15.209, and 15.225 Industry Canada Radio Standards Specification RSS-210 Issue 5, Section 6.2.2(e) (Category I Equipment) Note: The test data of this report relate only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 2 of 37 Pages Table of Contents 1. Administrative Data.....................................................................................3 2. Identification of Test Laboratory .................................................................4 3. Operation Mode of EUT..............................................................................6 4. Configuration ..............................................................................................7 5. Measuring Methods ....................................................................................8 5.1. Conducted Emission 0.15 MHz - 30 MHz (ß15.207 / IC RSS-210 sec. 6.6, 7.4) ........................................................................9 5.2. Field strength of in-band emissions (ß15.225 (a) / IC RSS-210 Section 6.2.2(e)) and unwanted emissions ≤ 30 MHz (ß15.225 (b) / IC RSS-210 Section 6.2.2(e))..............................11 5.3. Frequency tolerance (ß15.225 (c) / IC RSS-210 Section 6.2.2(e))..............................................................................................12 5.4. Unwanted Emission 30 MHz - 1 GHz (ß15.225 (b) / IC RSS-210 Section 6.2.2(e)) .................................................................14 6. Photographs Taken During Testing ..........................................................16 7. Equipment List ..........................................................................................22 8. Referenced Regulations ...........................................................................27 9. List of Measurements ...............................................................................28 9.1. List of Measurements According To FCC Part 15 Subpart C ...........................................................................................28 9.2. List of Measurements According To Industry Canada RSS-210.............................................................................................28 10. Test Results..............................................................................................29 Charts taken during testing ...............................................................................37 EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 3 of 37 Pages 1. Administrative Data Test item (EUT) Type designation Card Man Serial number(s): 001 Type of equipment: RFID Reader 13.56 MHz Parts/accessories: --- FCC-ID: --- Technical data Frequency range 13.553 - 13.567 MHz Operational frequencies 13.56 MHz Type of modulation 10K0A1D Pulse frequency N/A Pulse width N/A Antenna Integrated Power supply USB interface Applicant: (full address) Omnikey AG Zeulenrodaer Str. 17 D-99091 Erfurt Contract identification: Order no. 02082004/02 Contact person: Mr. Abu Ismail Manufacturer: Omnikey AG Application details Receipt of EUT: 09 August 2004 Date of test: August 2004 Note: --- Responsible for testing: Thomas Eberl Responsible for test report: Thomas Eberl EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 4 of 37 Pages 2. Identification of Test Laboratory DETAILS OF THE TEST LABORATORY COMPANY NAME: Senton GmbH EMI/EMC Test Center ADDRESS: Aeussere Fruehlingsstrasse 45 D-94315 Straubing Germany LABORATORY ACCREDITATION: DAR-Registration No. TTI-P-G 062/94-01 FCC TEST SITE LISTING 90926 INDUSTRY CANADA TEST SITE REGISTRATION IC 3050 NAME FOR CONTACT PURPOSES: Mr. Johann Roidt TELEPHONE: (+49) (0)9421 5522-0 FAX: (+49) (0)9421 5522-99 EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 5 of 37 Pages PERSONNEL INVOLVED IN THIS TEST REPORT LABORATORY MANAGER: Mr. Johann Roidt RESPONSIBLE FOR TESTING: Mr. Thomas Eberl RESPONSIBLE FOR TEST REPORT: Mr. Thomas Eberl SUMMARY OF TEST RESULTS The tested sample complies with the requirements set forth in the Code of Regulations CFR 47, Part 15, Sections 15.205, 15.207, 15.209, and 15.225 and Industry Canada Radio Standards Specification RSS-210 Issue 5, Section 6.2.2(e) (Category I Equipment) EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 6 of 37 Pages 3. Operation Mode of EUT Continuously reading appropriate TAG EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 7 of 37 Pages 4. Configuration Configuration of the EUT Not applicable Cables connected to the EUT USB IF cable Peripheral devices connected to the EUT Laptop PC Dell AC/DC Adapter Printer HP 2225C AC Adapter Hayes EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 8 of 37 Pages 5. Measuring Methods EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 9 of 37 Pages 5.1. Conducted Emission 0.15 MHz - 30 MHz (ß15.207 / IC RSS-210 sec. 6.6, 7.4) Conducted emissions were measured in the frequency range 0.15 MHz to 30 MHz with bandwidth of the EMI-Receiver set to 10 kHz and according to the following procedure: First the whole spectrum of emission caused by equipment under test (EUT) was recorded with detector set to peak. After that all peak levels having less margin than 10 dB to the appropriate lower average limit were re-tested with detector set to quasi-peak. If average limit is kept no additional scan with average detector is necessary. In cases of emission levels be…
Text truncated - open the document above for the full version.
EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 17 of 37 Pages Test setup for conducted power line emission measurement EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 18 of 37 Pages Test setup for conducted power line emission measurement EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 19 of 37 Pages Test setup for radiated emission measurement (fully anechoic room) EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 20 of 37 Pages Test setup for radiated emission measurement (open area test site) EMV-Pr ̧fzentrum EMI/EMC-Testcenter FCC-ID: Test Report No. 51514-40562 Page 21 of 37 Pages Test setup for radiated emission measurement (open area test site)
Aeussere Fruehlingstrasse 45 · Straubing · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Inductive TAG-Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter