Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Digi International, Inc. User’s Guide - 1 - Digi Wi-Point 3G Wireless Cellular Data Gateway User’s Guide 90000906_A Digi International, Inc. User’s Guide - 2 - Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Digi International, Inc. declares that Digi Wi-Point 3G (FCC ID:SUMMB8600D) is limited in CH1~CH11 for 2.4GHz by specified firmware controlled in U.S.A. Digi International, Inc. User’s Guide - 3 - Table of Contents 1 ABOUT THIS GUIDE.................................................................................................................... 4 1 INTRODUCTION........................................................................................................................... 5 2 INSTALLING THE DIGI WI-POINT 3G...................................................................................... 6 2.1 VERIFY KIT CONTENTS............................................................................................................. 7 2.2 WRITE PRODUCT IDENTIFICATION............................................................................................ 8 2.3 POWER UP THE DIGI WI-POINT 3G............................................................................................ 8 2.4 LED INDICATORS................................................................................................................... 10 2.5 INITIALIZE THE DIGI WI-POINT 3G UNIT................................................................................ 11 3 USER INTERFACE OVERVIEW.............................................................................................. 13 3.1 MENU COMPONENTS.............................................................................................................. 15 3.1.1 Configuration...............................................................................................................15 3.1.2 Management..............................................................................................................27 3.1.3 Administration..............................................................................................................29 4 TROUBLESHOOTING............................................................................................................... 33 4.1 OVERVIEW.............................................................................................................................. 33 4.2 INTRODUCTION....................................................................................................................... 33 4.3 RESET TO FACTORY DEFAULT PROCEDURE............................................................................. 33 4.4 FORCED RELOAD PROCEDURE................................................................................................ 34 4.5 FREQUENTLY ASKED QUESTIONS............................................................................................ 35 5 DEFAULT DIGI WI-POINT 3G SETTINGS............................................................................. 39 Digi International, Inc. User’s Guide - 4 - 1 About This Guide This section describes the objectives, audience and conventions of the Digi Wi-Point 3G User’s Guide. Objectives This document explains the steps for initial setup and basic configuration of the Digi Wi-Point 3G. This document also provides troubleshooting information and detailed specifications. Audience This document is for the person installing and configuring the Digi Wi-Point 3G for the first time. The installer should be familiar with network structures, terms and concepts. Conventions This document uses the following conventions to convey instructions and information: Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual. Warning The warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Obtaining Documentation You can access the latest Digi International, Inc. d…
Text truncated - open the document above for the full version.
Top Global USA, Inc Date: February 19, 2008 Federal Communications Commission Authorization and Evaluation Division FCC ID: SUMMB8600D ATTESTATION FCC ID: SUMMB8600D Product: Digi Wi-Point 3G Model: Digi Wi-Point 3G We don't provide any controls or software to allow operation outside the USA frequency band when we sell this product in USA. Sincerely, Yu Yang/ Manager Top Global USA, Inc. ____________________________
RF_160, Issue 01 Declaration of Authorization We Name: Top Global USA,Inc. Address: 4605 Barranca Parkway Suit 101G, Irvine City, California, 92604 USA City: California .................................................................. . Country: USA ........................................................................... . Declare that: Name: QuieTek Corp. Address: Fl.2, No.345, Xin-hu 2 nd Rd., Nei-hu District City: Taipei Country Taiwan R.O.C. is authorized to apply for Certification of the following product(s): Product description: Digi Wi-Point 3G ................................. . Type designation: Digi Wi-Point 3G ....................................... . Trademark: Digi on our behalf. Date: ...... 2008/02/17 ............... .. City: ...... Irvine ........................ .. Name: ...... Yu Yang ..................... .. Signature: ...... ......... .
Top Global USA,Inc. Date: February 19, 2008 Federal Communications Commission Authorization and Evaluation Division FCC ID: SUMMB8600D Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: 1 Schematics 2 Block Diagram 3 Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Yu Yang/ Manager Top Global USA, Inc.
Digi Wi-Point 3G (M/N: Digi Wi-Point 3G) ¾ EUT Photograph – External Photographs (1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo (5) (6) (7) (8) (9) (10) EUT Photo
Digi Wi-Point 3G FCC ID Label FCC ID Label SUMMB8600D
Digi Wi-Point 3G (M/N: Digi Wi-Point 3G) FCC Label Position
Digi Wi-Point 3G (M/N: Digi Wi-Point 3G) ¾ EUT Photograph – internal Photographs (1) EUT Photo (2) (3) EUT Photo (4) EUT Photo (5) (6) (7) (8)
RF Exposure Evaluation Declaration Product Name : Digi Wi-Point 3G Model No. : Digi Wi-Point 3G FCC ID : SUMMB8600D Applicant : Top Global USA. Inc Address : 4605 Barranca Parkway Suit 101G, Irvine City, California, 92604 USA Date of Receipt : 2008/01/24 Issued Date : 2008/02/18 Report No. : 081S007-RF-US The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by CNLA, NVLAP, NIST or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Report No: 081S007-RF-US Page: 2 of 6 Test Report Certification Issued Date : 2008/02/18 Report No. : 081S007-RF-US Product Name : Digi Wi-Point 3G Applicant : Top Global USA. Inc Address : 8/F Reward Building, No.203 Wangjing Lizezhongyuan, Chaoyang District, Beijing, China Manufacturer : Top Global USA. Inc Address : 8/F Reward Building, No.203 Wangjing Lizezhongyuan, Chaoyang District, Beijing, China Model No. : Digi Wi-Point 3G FCC ID : SUMMB8600D Rated Voltage : AC 120 V / 60 Hz EUT Voltage : DC 5.0V Trade Name : Digi Applicable Standard : FCC OET 65 Test Result : Complied Performed Location : SuZhou EMC laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392 Documented By : ( Any Liu ) Reviewed By : ( Dream Cao ) Approved By : ( Murphy Wang ) Report No: 081S007-RF-US Page: 3 of 6 Laboratory Information We , QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited by the following accreditation Bodies in compliance with ISO 17025, EN 45001 and Guide 25: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site : http://tw.quietek.com/modules/myalbum/ The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : +886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, DGT, CNLA Germany :TUV Rheinland Norway :Nemko, DNV USA :FCC, NVLAP Japan :VCCI Report No: 081S007-RF-US Page: 4 of 6 1. RF Exposure Evaluation 1.1. Limits According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm2) Average Time (Minutes) (A) Limits for Occupational/ Control Exposures 300-1500 -- -- F/300 6 1500-100,000 -- -- 5 6 (B) Limits for General Population/ Uncontrolled Exposures 300-1500 -- -- F/1500 6 1500-100,000 -- -- 1 30 F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4*pi*r2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Report No: 081S007-RF-US Page: 5 of 6 1.2. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. The temperature and related humidity: 18°Cand 78% RH. 1.3. Test Result of RF Exposure Evaluation Product : Digi Wi-Point 3G Test Item : RF Exposure Evaluation Test Site : AC-3 Test Mode : Mode 1: Transmitter by 802.11b Antenna Gain: Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 dBi or 1.58 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm2) 01 2412.00 17.1002 0.005392 06 2437.00 16.7494 0.005281 11 2462.00 14.3549 0.004526 Note: The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm2. Report No: 081S007-RF-US Page: 6 of 6 Product : Digi Wi-Point 3G Test Item : RF Exposure Evaluation Test Site : AC-3 Test Mode : Mode 2: Transmitter by 802.11g Antenna Gain: Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 dBi or 1.58 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel Channel Frequency (MHz) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm2) 01 2412.00 15.2405 0.004805 06 2437.00 16.5577 0.005221 11 2462.00 15.2757 0.004816 Note: The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm2.
Test Report Product Name : Digi Wi-Point 3G Model No. : Digi Wi-Point 3G FCC ID : SUMMB8600D Applicant : Top Global USA. Inc Address : 4605 Barranca Parkway Suit 101G, Irvine City, California, 92604 USA Date of Receipt : 2008/01/24 Issued Date : 2008/02/18 Report No. : 081S007-RF-US-P05V01 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by CNLA, NVLAP or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Report No: 081S007-RF-US-P05V01 Page: 2 of 123 Test Report Certification Issued Date : 2008/01/24 Report No. : 081S007-RF-US-P05V01 Product Name : Digi Wi-Point 3G Applicant : Top Global USA. Inc Address : 8/F Reward Building, No.203 Wangjing Lizezhongyuan, Chaoyang District, Beijing, China Manufacturer : Top Global USA. Inc Address : 8/F Reward Building, No.203 Wangjing Lizezhongyuan, Chaoyang District, Beijing, China Model No. : Digi Wi-Point 3G FCC ID : SUMMB8600D Rated Voltage : AC 120 V / 60 Hz EUT Voltage : DC 5.0V Trade Name : Digi Applicable Standard : FCC CFR Title 47 Part 15 Subpart C: 2007 ANSI C63.4: 2003 Test Result : Complied Performed Location : SuZhou EMC laboratory No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392 Documented By : ( Any Liu ) Reviewed By : ( Dream Cao ) Approved By : ( Murphy Wang ) Report No: 081S007-RF-US-P05V01 Page: 3 of 123 Laboratory Information We , QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited by the following accreditation Bodies in compliance with ISO 17025, EN 45001 and Guide 25: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site : http://tw.quietek.com/modules/myalbum/ The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : +886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, DGT, CNLA Germany :TUV Rheinland Norway :Nemko, DNV USA :FCC, NVLAP Japan :VCCI Report No: 081S007-RF-US-P05V01 Page: 4 of 123 TABLE OF CONTENTS Description Page 1. General Information .......................................................................................................6 1.1. EUT Description .........................................................................................................6 1.2. Mode of Operation .....................................................................................................8 1.3. Tested System Details................................................................................................9 1.4. Configuration of Tested System ...............................................................................10 1.5. EUT Exercise Software ............................................................................................ 11 2. Technical Test ..............................................................................................................12 2.1. Summary of Test Result ...........................................................................................12 2.2. Test Environment.....................................................................................................13 3. Conducted Emission ....................................................................................................14 3.1. Test Equipment ........................................................................................................14 3.2. Test Setup ................................................................................................................14 3.3. Limit.... .....................................................................................................................15 3.4. Test Procedure.........................................................................................................15 3.5. Uncertainty ...............................................................................................................15 3.6. Test Result...............................................................................................................16 3.7. Test Photograph.......................................................................................................28 4. Radiated Emission.......................................................................................................30 4.1. Test Equipment ........................................................................................................30 4.2. Test Setup ................................................................................................................31 4.3. Limit.... .....................................................................................................................32 4.4. Test Procedure.........................................................................................................32 4.5. Uncer…
Text truncated - open the document above for the full version.
Page: 1 of 7 Digi Wi-Point 3G (M/N: Digi Wi-Point 3G) ¾ Test Setup Photographs for Conducted Emission Test Mode: Mode 1: Transmit by 802.11b Description: Front View of Conducted Emission Test Setup Page: 2 of 7 Test Mode: Mode 1: Transmit by 802.11b Description: Back View of Conducted Emission Test Setup Test Mode: Mode 2: Transmit by 802.11g Description: Front View of Conducted Emission Test Setup Page: 3 of 7 Test Mode: Mode 2: Transmit by 802.11g Description: Back View of Conducted Emission Test Setup Page: 4 of 7 ¾ Test Setup Photographs for Radiated Emission Test Mode : Mode 1: Transmit by 802.11b Description : Front View of Radiated Emission Test Setup for Under 1GHz Test Mode : Mode 1: Transmit by 802.11b Description : Back View of Radiated Emission Test Setup for Under 1GHz Page: 5 of 7 Test Mode : Mode 1: Transmit by 802.11b Description : Front View of Radiated Emission Test Setup for Above 1GHz Test Mode : Mode 1: Transmit by 802.11b Description : Back View of Radiated Emission Test Setup for Above 1GHz Page: 6 of 7 Test Mode : Mode 2: Transmit by 802.11g Description : Front View of Radiated Emission Test Setup for Under 1GHz Test Mode : Mode 2: Transmit by 802.11g Description : Back View of Radiated Emission Test Setup for Under 1GHz Page: 7 of 7 Test Mode : Mode 2: Transmit by 802.11g Description : Front View of Radiated Emission Test Setup for Above 1GHz Test Mode : Mode 2: Transmit by 802.11g Description : Back View of Radiated Emission Test Setup for Above 1GHz
No.99 Hongye RD.Suzhou Industrial Park · Suzhou · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 17.10 mW |

Mobile Bridge
Equipment Class
DTS - Digital Transmission System
802.11g Mini PCI Card
Equipment Class
DTS - Digital Transmission System
Mobile Bridge
Equipment Class
DTS - Digital Transmission System
2.4GHz Mobile Bridge
Equipment Class
DTS - Digital Transmission System