Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03/18/2024 Ref: Attestation Statement Part 2.911(d)(7) Filing Grantee Code: SWX Ubiquiti Inc. certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. Ubiquiti Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission- related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 2445 NE Division Street, Suite 202 Bend, OR 97703 United States Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, Ubiquiti Inc. FRN:0012268215 Americas Compliance Consulting LLC dba iCertifi Alex Macon Paul Preston
Ubiquiti Inc. 685 Third Avenue, New York, NY United States 10017 Tel: 385-200-1617 ; Fax: 408-904-7556 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Date: April 22, 2026 Subject: Certifications concerning “covered” equipment pursuant to Part 2.911(d)(5)(i) and (ii) FCC ID: SWX-USLGGH To whom it may concern, Ubiquiti Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not the equipment on the Covered List, as established pursuant to § 1.50002 of CFR Title 47, that is prohibited from obtaining an equipment authorization under this subpart. This includes equipment that: (1) Has been certified as a modular transmitter; or (2) Meets the modular transmitter requirements of § 15.212 of this chapter and could be certified as a modular transmitter. pursuant to section 2.903 resulting the recent adoption of FCC 25-71 (et al., ET Docket No. 21-232, Second Report and Order); or (3) Uncrewed aircraft systems (UAS) and UAS critical components produced in a foreign country and all communications and video surveillance equipment and services listed in Section 1709(a)(1) of the FY25 National Defense Authorization Act (Pub. L. 118-159) Applicant certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Applicant further certifies that no Cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software is installed in the equipment being certified. The above-referenced Covered List is published by the Public Safety and Homeland Security Bureau (PSHSB), pursuant to Section 1.50002 of the Commission’s rules. Sincerely, ________________________ Name: Alex Macon E-mail: [email protected]
Subject: Attestation – Non-Consumer Grade Router Classification To: Federal Communications Commission Office of Engineering and Technology Laboratory Division Date: [6/02/2026] To Whom It May Concern: Pursuant to the Federal Communications Commission’s guidance regarding routers included in the Covered List and the definition of “consumer-grade routers” as referenced in NIST IR 8425A, Ubiquiti hereby provides the following attestation with respect to the device(s) identified below. Device Information ● Product Name: [SuperLink Gateway HA] ● FCC ID: [SWX-USLGGH] ● Model Number(s): [USL-G2-Gateway-HA] Attestation Statement Ubiquiti declares that the above-referenced equipment: 1. Technical Functionality: The product is a LoRa/SuperLink, Thread, and LTE Cat 1 bis IoT gateway for UniFi Protect / sensor and low-power device applications. Its function is to support constrained sensor and Thread endpoints, not to provide Internet access to ordinary customer client devices. The integrated LTE Cat 1 bis interface is used exclusively for IoT data backhaul and remote management backup communication; it does not provide general Internet access to client devices and does not function as a cellular WAN uplink for end-user traffic. Any IP forwarding associated with Thread is constrained to the Thread IoT network and related application/service traffic. It does not provide general-purpose routing between customer LAN and WAN networks, does not advertise itself as a household Internet gateway for Ethernet/Wi-Fi client devices, and does not substitute for a consumer home router. 2. Absence of Routing Features: The product does not provide the ordinary feature set of a consumer-grade router or residential gateway, including NAT, DHCP server for a client LAN, configurable LAN/WAN routing, firewall policy management for household networks, VPN, port forwarding, or household-client traffic management. 3. Exclusion from Router Scope: The device contains no user-configurable consumer distribution matrices, high-throughput consumer Wi-Fi Access Point (AP) routing radios, residential Virtual Private Network (VPN), or firewalls typically inherent to consumer-grade network routers or commercial ISP residential gateways. The LTE Cat 1 bis cellular interface present in this product is limited to IoT backhaul and management backup purposes and does not constitute a consumer-facing WAN interface for general broadband routing. 4. Deployment Context: The device is designed for specific industrial, enterprise, or IoT applications to manage low-power infrastructure and is not intended for residential consumer use, nor installation by typical consumer users. Basis for Classification This determination is based on the FCC's interpretation that consumer-grade routers are devices primarily intended for residential use. With the above-stated technical assumptions and operational realities, despite the “gateway” naming, this product does not meet the definition or functional criteria of a router and should not be considered a consumer-grade router or residential gateway under the referenced determination. Consequently, it should be excluded from the scope of the Covered List regarding consumer-grade network routing devices. Declaration This attestation is made based on information reasonably available to Ubiquiti at the time of submission. Ubiquiti affirms that the statements above are accurate to the best of its knowledge. ____________________ Name: Alex Macon Title: Compliance Director
Ubiquiti Inc. 685 Third Avenue, New York, NY United States 10017 Tel: 385-200-1617 ; Fax: 408-904-7556 Date: April 22, 2026 FCC Laboratory 7435 Oakland Mills Rd Columbia MD 21046 Subject: Request for Confidentiality FCC ID: SWX-USLGGH To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following documents from public disclosure indefinitely. ● Schematic Diagram ● Block Diagram ● Part List ● Operational Description ● Tune-up Procedure Above mentioned documents which contain detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we are requesting the Commission to withhold the following documents for 180 days after the grant of equipment authorization is issued: ● External Photos ● Internal Photos ● Test Setup Photos ● User Manual It is our understanding that all measurement test reports, FCC ID label format cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, _______________________ Alex Macon [email protected]
Ubiquiti Inc. 685 Third Avenue, New York, NY United States 10017 Tel: 385-200-1617 ; Fax: 408-904-7556 FCC Agent Authorization Date: April 22, 2026 To whom it may concern, Ubiquiti Inc. hereby authorize Jones Tsai in Sporton International Inc. to act on our behalf in all matters relating to applications for FCC equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by Jones Tsai in Sporton International Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to section 5301 of the Anti-Drug Abuse Act of 1988. 21 U.S.C. 862. This authorization is limited to the product of as following: FCC ID: SWX-USLGGH This authorization is valid until further written notice from Ubiquiti Inc.. Sincerely, ________________________ Alex Macon [email protected]
Ubiquiti Inc. E-Label Information Model: USL-G2-Gateway-HA A. Information to be displayed 1. The information that will be displayed on the e-label and information that will remain in the user manual is shown below: Information On e-label In Manual FCC/ISED ID number Yes No FCC logo / DoC logo No No 15.19 statement (“This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”) Yes No Class A / B Digital Device user manual statements 1 Yes No Caution to the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment 1 Yes Yes Describe any other FCC regulatory information included in e-label 1 Yes No 1 If the e-label includes information typically included in the manual then the e-label shall clearly differentiate between information required to be on the device’s surface and information required to be in the manual – refer to 784748 D02 e labelling v01 section II D 3(b) The e-label is provided as the below: B. Access to the required information on the e-label 1. Users are able to access the information in no more than three steps in a device’s menu. The actual steps are: E-label and warning statements can be found E-label 3 steps SOP as enclosed No special access codes or permissions are required to go through the above steps beyond entering a user-defined password to protect against unauthorized access to the device. No special access codes or permissions are required to go through the above steps beyond entering a user- defined password to protect against unauthorized access to the device. 2. The information is stored on the device, no special accessories or supplemental plug-ins (e.g., a SIM/USIM card) are required to access the information. Yes 3. Users are provided specific instructions on how to access the information. The information to the user is provided in the last page of user manual. C. Labeling for Importation and Purchasing Products utilizing e-labels are required to have a physical label on the product at the time of importation, marketing and sales. For devices imported in bulk and not packaged individually, a removable adhesive label or, for devices in protective bags, a label on the bags is acceptable for this purpose. Any removable label shall be of a type intended to survive normal shipping and handling and must only be removed by the customer after purchase. For devices imported already in individual packages ready for sale, the information may alternatively be provided on the package. It shall contain: 1. The FCC/ISED ID and/or the DoC logo (if applicable); and 2. Any other information required by specific rule to be provided on the surface of the product unless such information is permitted to be included in the User’s manual or other packaging inserts The FCC ID and model number are present on the product packaging. D. Other considerations 1. The above information must be programmed by the responsible party and the information must be secured in such a manner that third-parties cannot modify it. The e-label information is pre-programmed by the grantee. The user cannot modify the e-label information. 2. All the applicable regulatory information required on the packaging or user instructions must be provided according to the rules even if it is displayed electronically. For example, hearing aid compatibility (HAC) ratings for the phones as specified in 47 C.F.R. § 20.19. Yes, it is provided.
To start, log in to unifi.ui.com, and go to the page. "Site Manager" Finding E-compliance Information for UniFi Click on . "Update Manager" Click on the specific device for which you need information; details will appear in a side panel. Within the side panel, click on "Show Details" You can find the E-compliance information for the UniFi Device here. To start, log in to the device using the device IP address. Finding E-compliance Information for UISP Once on the UISP page, click on . "Settings" Click on . "Regulatory" You can find the E-compliance information for the UISP Device here.
TEL : 886-3-327-3456 Page : 1 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 RF EXPOSURE EVALUATION REPORT FCC ID : SWX-USLGGH Equipment : SuperLink Gateway HA Brand Name : UBIQUITI Model Name : USL-G2-Gateway-HA Applicant : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Manufacturer : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Standard : 47 CFR Part 2.1091 We, SPORTON INTERNATIONAL INC has been evaluated this product in accordance with 47 CFR Part2.1091 and it complies with applicable limit. Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code: 3786) and the FCC designation No. TW3786 under the FCC 2.948(e) by Mutual Recognition Agreement (MRA) in FCC evaluation. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full SPORTON INTERNATIONAL INC. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan Approved by: Cona Huang / Deputy Manager TEL : 886-3-327-3456 Page : 2 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 Table of Contents 1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 4 3. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 5 4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 6 4.1. Standalone Power Density Calculation ............................................................................................. 6 4.2. Collocated Power Density Calculation ............................................................................................... 7 TEL : 886-3-327-3456 Page : 3 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 History of this test report Report No. Version Description Issued Date FA581203 Rev. 01 Initial issue of report Jul. 01, 2026 TEL : 886-3-327-3456 Page : 4 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 1. Description of Equipment Under Test (EUT) Product Feature & Specification EUT Type SuperLink Gateway HA Brand Name UBIQUITI Model Name USL-G2-Gateway-HA FCC ID SWX-USLGGH Wireless Technology and Frequency Range LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 7: 2500 MHz ~ 2570 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 13: 777 MHz ~ 787 MHz LTE Band 25: 1850 MHz ~ 1915 MHz LTE Band 26: 814 MHz ~ 849 MHz LTE Band 38: 2570 MHz ~ 2620 MHz LTE Band 41: 2496 MHz ~ 2690 MHz LTE Band 66: 1710 MHz ~ 1780 MHz Bluetooth: 2400 MHz ~ 2483.5 MHz LoRa FHSS(125 kHz): 915 MHz ~ 928 MHz LoRa DTS(500 kHz): 915 MHz ~ 928 MHz Thread: 2400 MHz ~ 2483.5 MHz Mode LTE: QPSK, 16QAM Bluetooth LE Lora: GFSK Thread: GFSK Reviewed by: Jason Wang Report Producer: Daisy Peng 2. Maximum RF average output power among production units Mode Maximum Average power(dBm) LTE Band 2 23 Band 4 23 Band 5 23 Band 7 23 Band 12 23 Band 13 23 Band 25 23 Band 26 23 Band 38 23 Band 41 23 Band 66 23 LoRa (125kHz) 26.10 LoRa (500kHz) 13.81 BLE 17.97 Thread 17.53 TEL : 886-3-327-3456 Page : 5 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 3. RF Exposure Limit Introduction According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in §1.1310. The MPE was calculated at 20 cm to show compliance with the power density limit. The following formula was used to calculate the Power Density: 퐒= 퐏퐆 ퟒ훑퐑 ퟐ Where: S = Power Density P = Output Power at Antenna Terminals G = Gain of Transmit Antenna (linear gain) R = Distance from Transmitting Antenna TEL : 886-3-327-3456 Page : 6 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 4. Radio Frequency Radiation Exposure Evaluation 4.1. Standalone Power Density Calculation Band Antenna Gain (dBi) Maximum Power (dBm) Maximum EIRP (dBm) Maximum PG (mW) Power Density at 20cm (mW/cm^2) Limit (mW/cm^2) Power Density / Limit LTE Band 2 2.00 23.00 25.0 316.23 0.063 1.000 0.063 LTE Band 4 2.00 23.00 25.0 316.23 0.063 1.000 0.063 LTE Band 5 1.00 23.00 24.0 251.19 0.050 0.549 0.091 LTE Band 7 1.50 23.00 24.5 281.84 0.056 1.000 0.056 LTE Band 12 0.00 23.00 23.0 199.53 0.040 0.466 0.085 LTE Band 13 1.00 23.00 24.0 251.19 0.050 0.518 0.097 LTE Band 25 2.00 23.00 25.0 316.23 0.063 1.000 0.063 LTE Band 26 2.90 23.00 25.9 389.05 0.077 0.543 0.143 LTE Band 38 1.90 23.00 24.9 309.03 0.062 1.000 0.062 LTE Band 41 3.40 23.00 26.4 436.52 0.087 1.000 0.087 LTE Band 66 2.00 23.00 25.0 316.23 0.063 1.000 0.063 LoRa (125kHz) 1.00 26.10 27.1 512.86 0.102 0.610 0.167 LoRa (500kHz) 1.00 13.81 14.8 30.27 0.006 0.610 0.010 Bluetooth 4.00 17.97 22.0 157.40 0.031 1.000 0.031 Thread 4.00 17.53 21.5 142.23 0.028 1.000 0.028 TEL : 886-3-327-3456 Page : 7 of 7 FAX : 886-3-328-4978 Issued Date : Jul. 01, 2026 Form version: 200414 RF EXPOSURE EVALUATION REPORT Report No. : FA581203 4.2. Collocated Power Density Calculation <LTE + BT> WWAN(LTE) Power Density / Limit Bluetooth Power Density / Limit Σ(Power Density / Limit) of WWAN(LTE) + Bluetooth 0.143 0.031 0.174 Note: 1. Σ(Power Density / Limit): This is a summation of [(power density for each transmitter/antenna included in the simultaneous transmissio…
Text truncated - open the document above for the full version.
TEL : 886-3-327-3456 Page Number : 1 of 25 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CWL AC MA Version 2.5 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203A FCC RADIO TEST REPORT FCC ID : SWX-USLGGH Equipment : SuperLink Gateway HA Brand Name : UBIQUITI Model Name : USL-G2-Gateway-HA Applicant : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Manufacturer : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Standard : FCC Part 15 Subpart C §15.247 The product was received on Sep. 16, 2025 and testing was performed from Sep. 18, 2025 to Oct. 09, 2025. We, Sporton International Inc. EMC & Wireless Communications Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) TEL : 886-3-327-3456 Page Number : 2 of 25 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CWL AC MA Version 2.5 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203A Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description .................................................................................................................................... 5 1.1 Product Feature of Equipment Under Test ........................................................................................ 5 1.2 Modification of EUT ........................................................................................................................... 5 1.3 Testing Location ................................................................................................................................ 5 1.4 Applicable Standards ......................................................................................................................... 6 2 Test Configuration of Equipment Under Test .......................................................................................... 7 2.1 Carrier Frequency and Channel ........................................................................................................ 7 2.2 Test Mode .......................................................................................................................................... 8 2.3 Connection Diagram of Test System ................................................................................................. 9 2.4 Support Unit used in test configuration and system .......................................................................... 9 2.5 EUT Operation Test Setup .............................................................................................................. 10 2.6 Measurement Results Explanation Example ................................................................................... 10 3 Test Result ................................................................................................................................................. 11 3.1 6dB and 99% Bandwidth Measurement .......................................................................................... 11 3.2 Output Power Measurement ............................................................................................................ 12 3.3 Power Spectral Density Measurement ............................................................................................ 13 3.4 Conducted Band Edges and Spurious Emission Measurement ..................................................... 14 3.5 Radiated Spurious Emission Measurement .................................................................................... 15 3.6 AC Conducted Emission Measurement........................................................................................... 20 3.7 Antenna Requirements .................................................................................................................... 22 4 List of Measuring Equipment ................................................................................................................... 23 5 Measurement Uncertainty ........................................................................................................................ 25 Appendix A. Conducted Test Results Appendix B. AC Conducted Emission Test Result Appendix C. Radiated Spurious Emission Appendix D. Radiated Spurious Emission Plots Appendix E. Duty Cycle Plots Appendix F. Setup Photographs TEL : 886-3-327-3456 Page Number : 3 of 25 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CWL AC MA Version 2.5 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203A History of this test report Report No. Version Description Issue Date FR581203A 01 Initial issue of report Jul. 01, 2026 TEL : 886-3-327-3456 Page Number : 4 of 25 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CWL AC MA Version 2.5 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203A Summary of Test Result Report Clause Ref Std. Clause Test Items Result (PASS/FAIL) Remark 3.1 15.247(a)(2) 6dB Bandwidth Pass - 3.1 2.1049 99% Occupied Bandwidth Pass - 3.2 15.247(b)(3) Power Output Measurement Pass - 3.3 15.247(e) Power Spectral Density Pass - 3.4 15.247(d) Conducted Band Edges Pass - Conducte…
Text truncated - open the document above for the full version.
TEL : 886-3-327-3456 Page Number : 1 of 24 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CBT4.0 Version 2.4 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203C FCC RADIO TEST REPORT FCC ID : SWX-USLGGH Equipment : SuperLink Gateway HA Brand Name : UBIQUITI Model Name : USL-G2-Gateway-HA Applicant : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Manufacturer : Ubiquiti Inc. 685 Third Avenue, New York, New York 10017, USA Standard : FCC Part 15 Subpart C §15.247 The product was received on Sep. 04, 2025 and testing was performed from Sep. 09, 2025 to Oct. 29, 2025. We, Sporton International Inc. EMC & Wireless Communications Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) TEL : 886-3-327-3456 Page Number : 2 of 24 FAX : 886-3-328-4978 Issue Date : Jul. 01, 2026 Report Template No.: BU5-FR15CBT4.0 Version 2.4 Report Version : 01 FCC RADIO TEST REPORT Report No. : FR581203C Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ................................................................................................................................... 5 1.1 Product Feature of Equipment Under Test ........................................................................................ 5 1.2 Modification of EUT ........................................................................................................................... 5 1.3 Testing Location ................................................................................................................................ 5 1.4 Applicable Standards ......................................................................................................................... 6 2 Test Configuration of Equipment Under Test ......................................................................................... 7 2.1 Carrier Frequency Channel ............................................................................................................... 7 2.2 Test Mode .......................................................................................................................................... 8 2.3 Connection Diagram of Test System ................................................................................................. 9 2.4 Support Unit used in test configuration and system .......................................................................... 9 2.5 EUT Operation Test Setup .............................................................................................................. 10 2.6 Measurement Results Explanation Example ................................................................................... 10 3 Test Result ................................................................................................................................................ 11 3.1 6dB and 99% Bandwidth Measurement .......................................................................................... 11 3.2 Output Power Measurement ............................................................................................................ 12 3.3 Power Spectral Density Measurement ............................................................................................ 13 3.4 Conducted Band Edges and Spurious Emission Measurement ..................................................... 14 3.5 Radiated Band Edges and Spurious Emission Measurement ..................................................…
Text truncated - open the document above for the full version.
2445 NE Division Street, Suite 202 · Bend, 97703 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 94.80 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 86.10 mW |
| 3 | 15C | 915.6 MHz - 927.6 MHz | 42.00 mW |
Digital Transmission Radio
Equipment Class
DTS - Digital Transmission SystemRecessed Entry Sensor
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterG6 Edge Dome
Equipment Class
DTS - Digital Transmission SystemG6 Edge Turret
Equipment Class
DTS - Digital Transmission SystemSmoke and CO Sensor
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter