Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may n ot cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesire d operation. Modifications not expressly approved by this company coul d void the user's authority to operate the equipment. This equipment has been tested and found to comply with the lim its for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide r easonable protection against harmful interference in a residen tial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interf erence to radio communications. However, there is no guarantee that interf erence will not occur in a particular inst allation. If this equipment does cause harm ful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to co rrect the interference by one or more of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 1 of 19 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 2 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 3 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 7 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 8 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 9 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 12 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 13 of 19
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 4 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 5 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 6 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 10 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 11 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 14 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 15 of 19
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 15 / SUBPART B and C Test report no.: G4M20501-0358-C-1 FCC ID: SY9PANDALARM870 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 66 ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 1 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 Test Procedure 3 Test Results 3.1 Output power 3.2 Out of band radiated emission 3.3 Transmitter radiated emissions in restricted bands 3.4 Spurious emissions radiated, transmitter 3.5 20 dB bandwidth 3.6 Spurious emissions radiated, receiver 3.7 Automatical deactivation 3.8 Conduted measurement at (AC) power line ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 2 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Futhermore, there is no guarantee that a test sample which has Passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample posseses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extractes from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 23.02.2005 N. Kaspar Date ETS-Lab. Name Signature Technical responsibility for area of testing: 23.02.2005 Dr. Genz Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 3 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straรe 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 66 1.2.2 Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96-30 ACCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96-00 FCC FILED TEST LABORATORY REG. NO. 96970 A2LA Accredited Certification No.1983-01 B LUETOOTH QUALIFICATION TEST FACILITY (BQTF) Accredited by Bluetooth Qualification Review Board INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 1.3 Details of approval holder Name : LFF Security Equipment Co., Ltd. Street : Xiaolan Industrial Area, Xiaolan, Zhongshan, Town : Guangdong Country : China 528415 Telephone : +86-760-2138466 Fax : +86-760-2132886 Contact : Zhong Guo Ping Telephone : +86-760-2138466 ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 4 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 04.02.2005 Date of receipt of test item : 04.02.2005 Date of test : 09.02.2005 โ 10.02.2005 1.5 Test item Description of test item: 886B Car Alarm Type identification: Pandalarm 870 Serial number: Test sample without serial number Transmitting frequency: 433.914 MHz Remote Control Operation mode: simplex Transmitting mode: P1D Voltage supply: 12 V DC (battery) Antenna: integral antenna Photos: see Annex Manufacturer: (if applicable) Name : Street : Town : Country : Additional information: none ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 5 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC RULES PART 15 / SUBPART B ยง15.109/ SUBPART C ยง 15.203, ยง15.231 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests ย performed. 2.2 Test environment Temperature : 23 o C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa Details of power supply : 12 V DC (battery) ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 6 of 28 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment utilized No. Test equipment Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlรถder ETS 0002 Test receiver ESVP Rohde & Schwarz ETS 0003 Diode power sensor NRV-Z2 Rohde & Schwarz ETS 0004 Spectrum and network analyzer FSMS 26 Rohde & Schwarz ETS 0005 Test receiver SMV 11 MEB ETS 0006 Test receiver system SME 12 MEB ETS 0007 Horn antenna AT 4004 ar ETS 0008 Antenna Loop antenna Siemens ETS 0009 Antenna ARA 2 MEB ETS 0010 Antenna Loop antenna MEB ETS 0011 Antenna van Veen/ Frame Rohde & Schwarz ETS 0012 Antenna HK 116 Rohde & Schwarz ETS 0013 Antenna HL 223 Rohde & Schwarz ETS 0014 Antenna HL 025 Rohde & Schwarz ETS 0015 Antenna HL 025 Rohde & Schwarz ETS 0016 Precision antenna kit VHAP Schwarzbeck ETS 0017 Precision antenna kit UHAP Schwarzbeck ETS 0018 Horn antenna BBHA 9120 D Schwarzbeck ETS 0019 Horn antenna BBHA 9120 D Schwarzbeck ETS 0020 Antenna DP 21 MEB ETS 0021 Antenna DP 3 MEB ETS 0022 Antenna SAS-200/ 521 A.H. Systeme+D65 ETS 0023 Antenna DP 1 MEB ETS 0024 Antenna mast AF 2 MEB ETS 0025 Antenna mast AF 2 MEB ETS 0026 Tripod Heinrich Deisel ETS 0027 Tripod Heinrich Deisel ETS 0028 Tripod STA 2 C. Lorenz AG ETS 0029 Tripod Berlebach ETS 0030 Antenna HK 116 Rohde & Schwarz Eโฆ
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 16 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 17 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 18 of 19 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G4M20501-0358-C-1 Page 19 of 19
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.914 MHz - 433.914 MHz | - |

TIRE PRESSURE MONITORING SYSTEM
Equipment Class
DTS - Digital Transmission System
TIRE PRESSURE MONITORING SYSTEM
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
TIRE PRESSURE MONITORING SYSTEM
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
TIRE PRESSURE MONITORING SYSTEM
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter