
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ATTESTATION STATEMENT Applicant: Feit Electric Company Add: 4901 Gregg Road, Pico Rivera, California, United States 90660 Tel: (562) 463-2852 ext. 103 Email: [email protected] Date: 05/04/2023 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statemen ts Part 2.911(d)(5)(i), (ii) Filing FCC ID: SYW-BTA19RGB3KECP Feit Electric Company, certifies t hat t he equipment f or which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. And Feit Electric Company, certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List a s an entity producing “covered” equipment. Sincerely, Signed by (printed name): Aaron Feit Signature:
U.S. AGENT LETTER OF ATTESTATION Date: 05/04/2023 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 R ef: Attestation Statements Part 2.911(d)(7) Filing FCC ID: SYW-BTA19RGB3KECP Feit Electric Company certifies that, as of the date of the filing of the application, Feit Electric Company is our designated U.S. agent for service of process f or the above referenced FCC ID. Feit Electric Company accepts t o maintain an agent for no less t han one year afte r the grantee has t erminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Feit Electric Company accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Feit Electric Company Address: 4901 Gregg Road, Pico Rivera, California, United States 90660 Tel.: (562) 463-2852 ext. 103 Email: [email protected] Signed by (printed name): Aaron Feit Signature: Applic ant: Feit Electric Company Add: 4901 Gregg Road, Pico Rivera, California, United States 90660 Tel: (562) 463-2852 ext. 103 Email: [email protected] Signed by (printed name): Aaron Feit Signature:
QA-FR-170-B Company: Feit Electric Company Add: 4901 Gregg Road, Pico Rivera, California, United States 90660 Tel: (562) 463-2852 ext. 103 Fax: (562) 908-6360 E-mail: [email protected] FCC Authorization Date: 05/04/2023 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , Feit Electric Company, Hereby authorizes China Certification IC T Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification IC T Co., Ltd (Dongguan). on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Print Name: Aaron Feit Title: President
QA-FR-171-A Company: Feit Electric Company Add: 4901 Gregg Road, Pico Rivera, California, United States 90660 Tel: (562) 463-2852 ext. 103 Fax: (562) 908-6360 E-mail: [email protected] FCC Confidential Authorization Date: 0 5/04/2023 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: C onfidentiality Request regarding application for certification of FCC ID: SYW-BTA19RGB3KECP In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Feit Electric Company hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printer Name: Aaron Feit Title :President
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT
SKU# 1009527730 Model BTA19RGB3KECP 8.3W 750 LUMENS RGB+3000K 120V 60Hz 85mA FCC ID: SYW-BTA19RGB3KECP
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS chip ant
China Certification ICT Co., Ltd (Dongguan) Report No.: CR230312406-00B Page 58 of 58 5. RF EXPOSURE EVALUATION 5.1 Applicable Standard According to §1.1307(b)(3)(i) (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Table 1 to § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF Source frequency (MHz) Threshold ERP (watts) 0.3-1.34 1,920 R 2 . 1.34-30 3,450 R 2 /f 2 . 30-300 3.83 R 2 . 300-1,500 0.0128 R 2 f. 1,500-100,000 19.2R 2 . 5.1.2 Measurement Result Operation Modes Frequency (MHz) λ/2π (mm) Distance (mm) Exemption ERP Maximum Conducted Power including Tune-up Tolerance (dBm) Antenna Gain (dBi) ERP (dBm) MPE- Based Exemption (mW)(dBm) BLE 2402-2480 19.88 200 768 28.454 -2.77 -0.92 Compliant BDR/EDR 2402-2480 19.88 200 76828.455-2.77 0.08 Compliant Note: The Maximum Conducted Power including Tune-up Tolerance was declared by manufacturer. Result: The device compliant the MPE-Based Exemption at 20cm distances. ===== END OF REPORT =====
AntennaTestReport LightcontrolV1.1 CustomerIMES Agent Projectname Lightcontrol Model.IC— Model.ANTW50A0F245H07 Onewave 2022/12/19 1 2 LCP/N Ant.W50A0F245H07 12.0pFMurata 21.0pFMurata 35.6nHMurata •AntennaPlacement Ant.Matching •MatchingCircuit Antennaclearancearea:--mm 3 40.00 LogMag10.OOdB/Ref0.OOOdBJ;F1] SWRi.obo/Refi.ooo[FI] 2.4000000 GHZ 2.4500000 GHZ 2.4830000 GHZ 2.4543750 GHZ 10.00 000 -10.00 -20.00 -30.00 -40.00 -50.00j Clrbr仁口, Ant.S11Parameter E5071CNetworkAnalyzer 1ActiveCh/Trace2Response3Stimulus4Mkr/Analysis5InstrStateResize 4 EquipmentofOTAtest LineanalyzerE5071C Comprehensivetester MW500 MicrowavedarkroomFTM-24DMoreprobes ■ 5 10.14 11.98 13.82 15.67 17.51 19.35 21.19 23.03 24.88 26.72 28.56 -30.4 32.24 34.09 [email protected] PassiveTest(freespace) Y Frequency(MHz)2400.02410.02420.02430.02440.02450.02460.02470.02480.02490.02500.0 Gain(dBi) -3.39-3.26-3.29 - 3.41-3.01-2.77 - 2.79-2.92-3.15-3.55 -4.11 Efficiency(%) 12.6013.6714.4014.9515.0814.8714.1913.4012.5311.5110.47 ■ Conclusion -Thetestdatameetscustomerstandards. OnEUJHVE 6
TEST REPORT Applicant: Feit Electric Company Address: 4901 Gregg Road, Pico Rivera, California, United States 90660 FCC ID: SYW-BTA19RGB3KECP Product Name: LED lamp Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230312406-00B Date Of Issue: 2023/4/25 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230312406-00B Page 2 of 58 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230312406-00B Page 3 of 58 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 7 1.2.1 EUT Operation Condition: ............................................................................................................................. 7 1.2.2 Support Equipment List and Details .............................................................................................................. 7 1.2.3 Support Cable List and Details ...................................................................................................................... 7 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 8 1.3 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 2. SUMMARY OF TEST RESULTS .......................................................................................... 10 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 11 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 11 3.1.1 Applicable Standard ..................................................................................................................................... 11 3.1.2 EUT Setup.................................................................................................................................................... 12 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 12 3.1.4 Test Procedure ............................................................................................................................................. 13 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 13 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 14 3.2.1 Applicable Standard ..................................................................................................................................... 14 3.2.2 EUT Setup.................................................................................................................................................... 14 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 15 3.2.4 Test Procedure ............................................................................................................................................. 15 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 15 3.3 20 DB EMISSION BANDWIDTH ........................................................................................................... 16 3.3.1 Applicable Standard ........…
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.90 mW |

Remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Smart TV Backlight
Equipment Class
DTS - Digital Transmission System
Tape Light
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wall light
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter