FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Outsource Industries, Inc./
  3. SZAOSI911P433

SZAOSI911P433EMERGENCY HELP DIALER

Outsource Industries, Inc.
EMERGENCY HELP DIALER - FCC ID SZAOSI911P433 - Outsource Industries, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 27, 2010
Application Purpose
Original Equipment
Date of Application
Jan 27, 2010
Equipment Note
EMERGENCY HELP DIALER
Frequency Range
433.63700000 - 433.63700000
Company
Outsource Industries, Inc.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EMERGENCY HELP DIALER MODEL 911 II Operation and Instruction Manual Suitable for home-alone elderly or single persons, recovering patients, disabled persons, small businesses etc. Important information and instructions for your Emergency Help Dialer ( EHD ) Please keep this booklet in a readily accessible place PLEASE READ CAREFULLY Contents Pg. 2 *Features, Emergency Dialer Components, and DISCLAIMER Pg. 3 *Precautions and Maintenance Pg. 4 *Names and Functions of each part Pg. 5 *Installation and Functioning test of the main unit Pg. 6 *Procedure for storing phone numbers and recording messages Pg. 7 *Procedure for storing phone numbers and recording messages continued Pg. 8 *Procedure for storing phone numbers and recording messages continued Pg. 8 *Retrieving the setting contents, Description of Quick Function commands Pg. 9 *Operation Directions for 2 Way Communication Pg. 10 *Operation Directions for 2 Way Communication continued Pg. 11 *Testing and Replacing Battery Pg. 12 * Specifications and Approvals Pg. 13 *Warranty and contact details 1 Features Congratulations, you have purchased a high quality Emergency Help Dialer (EHD) which is easy to program and lets you call for help when you cannot dial the phone yourself. When you are in need of help, gently, but firmly push the two red panic buttons of the wireless EHD pendant. Using your existing telephone line, the console when activated will receive the signal and dial up to 5 pre-set phone numbers and play the message you have recorded. If a call is not answered, then the console will sequentially move on to dialing the next number, until all 5 numbers have been called. On the unlikely event that none of the numbers called have answered the console will repeat this sequence once more. When a call is answered the receiver will hear your pre-recorded voice message requesting immediate assistance. The console is programmed to recognize that the call is being answered by a live person. Emergency Dialer Components : 1. One main dialing console 2. One Wireless Waterproof Pendant 3. One AC/DC adaptor 4. One modular line cord 5. One rechargeable 9 volt battery 6. One plastic necklace 7. One wrist band 8. One owner’s manual Disclaimer : Under no circumstances should this Emergency Help Dialer (EHD) be solely relied upon in life threatening circumstances. Using EHD completely indemnifies the Manufacturer and/or its selling agents from any legal action for whatever reason. 2 Precautions & Maintenance 1. To reduce the risk of electric shock do not remove cover or back of the console. 2. Keep the product from being installed at places liable to dirt, high temperature, moisture and sun exposure, avoid heavy blows or dropping. 3. The placement of the main unit is closely related to its receiving range. To attain the best efficiency of application, try to avoid placing the main unit on electrical appliances (such as TV sets, computers, motors) as well as metal cabinets. It is also inappropriate to place it in the corner or on the floor. 4. This unit calls out and plays the message through a regular telephone set. If the telephone set has both Tone / Pulse dialing types, set it to "Tone". 5. Dialer will not work with a cordless phone that requires an AC adaptor when their is a power outage. You must use regular phone. 6. To have the surveillance feature, an answering machine will not operate or be able to receive any incoming messages. This is only for incoming calls and does not affect the 2 way communication on out going calls during the emergency operational phase. You can answer your phone during the ringing. It will stop ringing after 5th ring and the surveillance mode will take affect. 3 Yellow Call Button Names and Functions of Each Part 1. Main Unit (Power Supply : 12VDC Adaptor/500mA) 2. Wireless Help Caller (Power Supply : 12V Battery (Alkaline Battery Recommended) Size 23A (Included) 4 Action Indicator / Panic Button Antenna Speaker Internal Mic DC Power jack Function switch Telephone line jack Phone set jack Battery Cap EXT : Alarm jack Action Indicator Red Panic Button Hole Pin Hole Wrist Tape Necklace Installation and Functioning Test of the Main Unit 1. Plug one end of the AC adaptor into the “POWER” jack on the back of the main unit and the other end into an AC outlet that is not switched on or off by a wall switch. 2. Open the battery cap and place the 9V battery inside. 3. Plug one end of the supplied modular line cord into the jack labeled “LINE” on the back of the main unit and the other end into a modular phone jack available in your home. 4. Plug the modular cord line of your home telephone into the jack labeled “TEL” on the back of the main unit. 5. If you have purchased an extra alarm, either a flash siren or a panic switch, you can connect it to the “EXT” jack on the back of the main unit. The interface is on the above. 6. After connecting the main unit, please place the “FUNCTION” switch (on rear of main unit) to “MUTE” or “ALARM” position. If you press the “Call” button on the wireless help caller and the main unit beeps, this indicates that the wireless help caller and the main unit are working. Note: ALARM: When function is set to this position, a 15 second siren will go off when the panic button is pressed and the dialing console will automatically dial out the phone number you pre-set for help. Mute: When function is set to this position, there will be no siren. However, the dialing console will automatically dial out the phone number you pre-set. 5 Procedures For Storing Phone Numbers And Recording Messages 1. Place the “FUNCTION” switch selector on the rear of the main unit to “SET ”. The main unit will give off a long beep sound. A small red dot will appear on the indication window, showing that the main unit is properly connected. 2. Pick up the handset of the telephone that is connected to you Emergency Dialer. 3. Setting the first set of emergency telephone number Procedure: Example: If the first help number …

Text truncated - open the document above for the full version.

Cover Letter(s)

910805 3 Outsource Industries, Inc. 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C. Date: Dec.20,2009 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: We, the undersigned, hereby authorize ELECTRONICS TESTING CENTER, TAIWAN, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by ELECTRONICS TESTING CENTER, TAIWAN on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing ELECTRONICS TESTING CENTER, TAIWAN as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; 910805 4 f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, (signature) Aaron Shrenker President Outsource Industries, Inc. 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C.

Cover Letter(s)

910805 5 Outsource Industries, Inc. 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C. Federal Communications Commission FCC ID: SZAOSI911P433 Product Name: EMERGENCY HELP DIALER Model Name: 911IIP Trade Name: OSI Dear Sir: In accordance with 47 C.F.R. Section 0.459, we would like to request confidentiality on some exhibits we submitted for above application for the reason of trade secret. If those exhibits are available for public inspection, any person who once gets the information contained in those exhibits will be able to design and to make the same products very easily. This is a very serious problem and huge loss for us, because we did invest so much on it. Please be not made the Exhibit Types listed below routinely available for public inspection: Block Diagram and Schematics and Operation Description. By: By: Aaron Shrenker (Signature) (Printed) Title : President Applicant : Outsource Industries, Inc. Address : 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C. Tel : 886-2-27568016 Fax: 886-2-27648940 Date : Dec.20,2009

External Photos

ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Mode : Tx Top View of EUT Side View of EUT ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Front View of EUT Side View of EUT ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Rear View of EUT Bottom View of EUT

ID Label/Location Info

910805 1 LABEL 32mm 22mm Outsoure Industries, Inc. Model : 911IIP FCC ID : SZAOSI911P433 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Internal View of EUT ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 CONSTRUCTED PHOTOS of EUT Component View of PCB Solder View of PCB

Test Report

Rev. No 1.0 FCC Part 15 EMI TEST REPORT of E.U.T. : EMERGENCY HELP DIALER FCC ID : SZAOSI911P433 MODEL : 911IIP Workin g Frequency : 433.637 MHz for APPLICANT : Outsource Industries, Inc. ADDRESS : 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C. Test Performed by ELECTRONICS TESTING CENTER, TAIWAN NO.34, LIN 5, DINGFU TSUEN, LINKOU SHIANG TAIPEI COUNTY, TAIWAN, 24442, R.O.C. TEL : (02)26023052 Fax : (02)26010910 http://www.etc.org.tw ; e-mail: [email protected] Report Number : 09-11-RBF-133 ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 TEST REPORT CERTIFICATION Applicant : Outsource Industries, Inc. 10F/1, No. 175 Sec. 5 Min Sheng E.Rd. Taipei, Taiwan R.O.C. Manufacturer : HOMPET ENTERPRISE CO., LTD. No. 24, Alley 5, Lane 289, Chwang Ching Rd., Taipei, Taiwan, R.O.C. Description of EUT : a) Type of EUT : EMERGENCY HELP DIALER b) Trade Name : OSI c) Model No. : 911IIP d) FCC ID : SZAOSI911P433 e) Working Frequency : 433.637 MHz f) Power Supply : Tx: DC 12 V Battery Regulation Applied : FCC Rules and Regulations Part 15 Subpart C (2008) I HEREBY CERTIFY THAT; The data shown in this report were made in accordance with the procedures given in ANSI C63.4 and the energy emitted by the device was founded to be within the limits applicable. I assume full responsibility for accuracy and completeness of these data. Note : 1. The results of the testing report relate only to the items tested. 2. The testing report shall not be reproduced except in full, without the written approval of ETC. ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 Issued Date : Jan. 25, 2010 Test Engineer : ( Vincent Chang, Engineer ) Check By : ( Charles Wang, Supervisor ) Approve & Authorized Signer : Will Yauo, Manager EMC Dept. II of ELECTRONICS TESTING CENTER, TAIWAN ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 Table of Contents Page 1. GENERAL INFORMATION ............................................................................................................................... 1 1.1 PRODUCT DESCRIPTION.......................................................................................................................................... 1 1.2 CHARACTERISTICS OF DEVICE: ...............................................................................................................................1 1.3 TEST METHODOLOGY............................................................................................................................................. 1 1.4 TEST FACILITY........................................................................................................................................................ 1 2. DEFINITION AND LIMITS ................................................................................................................................ 2 2.1 DEFINITION............................................................................................................................................................. 2 2.2 RESTRICTED BANDS OF OPERATION....................................................................................................................... 2 2.3 LIMITATION............................................................................................................................................................ 2 2.4 LABELING REQUIREMENT....................................................................................................................................... 4 2.5 USER INFORMATION............................................................................................................................................... 4 3 SYSTEM TEST CONFIGURATION ................................................................................................................... 5 3.1 JUSTIFICATION........................................................................................................................................................ 5 3.2 DEVICES FOR TESTED SYSTEM................................................................................................................................5 4. RADIATED EMISSION MEASUREMENT ...................................................................................................... 6 4.1 APPLICABLE STANDARD......................................................................................................................................... 6 4.2 MEASUREMENT PROCEDURE................................................................................................................................... 6 4.3 TEST DATA............................................................................................................................................................. 8 4.4 FIELD STRENGTH CALCULATION.......................................................................................................................... 10 4.5 ACTIVATE TIME.................................................................................................................................................... 10 4.6 CALCULATION OF DUTY FACTOR.......................................................................................................................... 10 4.7 RADIATED TEST EQUIPMENT................................................................................................................................15 4.8 MEASURING INSTRUMENT SETUP......................................................................................................................... 15 4.9 RADIATED MEASUREMENT PHOTOS...................................................................................................................... 16 5. BANDWIDTH OF EMISSION........................................................................................................................... 17 5.1 APPLICABLE STANDARD PLOT GRAPHIC OF BANDWIDTH...................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ETC Report No.:09-11-RBF-133 FCC ID.: SZAOSI911P433 Rev. No 1.0 Radiated Measurement Photos

Contact Information

Applicant

Aaron Shrenker(President)
[email protected]886-2-27568016Fax: 886-2-27648940

Test Firm

Electronics Testing Center, TaiwanWill Yauo
[email protected]886-3-3280026Fax: 886-3-3280034

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.637 MHz - 433.637 MHz-
Confidentiality
Long Term

Other Applications from Outsource Industries, Inc.

Portable Sound Source-Transmitter - FCC ID SZAOSIPSSLTX - Outsource Industries, Inc.
SZAOSIPSSLTX

Portable Sound Source-Transmitter

Oct 22, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Emergency Helper Dialer (Transmitter) - FCC ID SZAOSI911PII - Outsource Industries, Inc.
SZAOSI911PII

Emergency Helper Dialer (Transmitter)

Mar 20, 2005

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter