T2RVR320Low Power RFID Transceiver

Exavera Technologies Inc.
Low Power RFID Transceiver - FCC ID T2RVR320 - Exavera Technologies Inc.
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Mar 18, 2007
Application Purpose
Original Equipment
Date of Application
Mar 18, 2007
Equipment Note
Low Power RFID Transceiver
Frequency Range
907.80000000 - 922.80000000
Company
Exavera Technologies Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Guide: VeraFi™ and VeraRelay™ PRELIMINARY CONTENT ONLY 2 Copyright © 2005-2006, Exavera Technologies Incorporated All rights reserved. Patents pending. No part of this documentation may be reproduced in any form without written permission from Exavera Technologies Incorporated Exavera Technologies Incorporated reserves the right to revise this documentation and to make changes without notification of such revision or change. THE SYSTEM, DOCUMENTATION AND SERVICES ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND. EXAVERA TECHNOLOGIES INCORPORATED DOES NOT WARRANT THAT THE SYSTEM WILL MEET CUSTOMER'S REQUIREMENTS, OR THAT THEIR OPERATION WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT ANY ERRORS CAN OR WILL BE FIXED. COMPANY HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, WITH RESPECT TO THE SYSTEM AND SERVICES INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF TITLE, NON-INFRINGEMENT, INTEGRATION, MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING OR PERFORMANCE OR USAGE OF TRADE. EXAVERA TECHNOLOGIES INCORPORATED SHALL NOT BE LIABLE CONCERNING THE SYSTEM OR SUBJECT MATTER OF THIS DOCUMENTATION, REGARDLESS OF THE FORM OF ANY CLAIM OR ACTION (WHETHER IN CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE), FOR ANY (A) MATTER BEYOND ITS REASONABLE CONTROL, (B) LOSS OR INACCURACY OF DATA, LOSS OR INTERRUPTION OF USE, OR COST OF PROCURING SUBSTITUTE TECHNOLOGY, GOODS OR SERVICES, (C) INDIRECT, PUNITIVE, INCIDENTAL, RELIANCE, SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF BUSINESS, REVENUES, PROFITS OR GOODWILL, OR (D) DIRECT DAMAGES, IN THE AGGREGATE, IN EXCESS OF THE FEES PAID TO IT HEREUNDER FOR THE SYSTEM OR SERVICE GIVING RISE TO SUCH DAMAGES DURING THE 12-MONTH PERIOD PRIOR TO THE DATE THE CAUSE OF ACTION AROSE, EVEN IF COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THESE LIMITATIONS ARE INDEPENDENT FROM ALL OTHER PROVISIONS OF THIS AGREEMENT AND SHALL APPLY NOTWITHSTANDING THE FAILURE OF ANY REMEDY PROVIDED HEREIN. All Exavera Technologies products are furnished under a license agreement included with the product. If you are unable to locate a copy of the license agreement, please contact Exavera Technologies Incorporated. Exavera® is a registered trademark owned and licensed by Exavera Technologies Incorporated. VeraFi™ and VeraReader™ are trademarks owned and licensed by Exavera Technologies Incorporated. All other company and product names are or may be trademarks of the respective companies with which they are associated. 3 Table of Contents Regulatory Compliance 4 Introduction 6 Audience and Objectives 6 Product Overview 6 How to Get Help 6 Safety 6 Installation 7 Unpack the System 7 Before You Start 9 VeraFi Installation 10 VeraRelay Installation 10 VeraFi Set-up, Connection and Configuration 11 Default IP Address Behavior 11 Accessing the VeraFi Online Web GUI For the First Time 11 Connecting to the VeraFi Locally 12 Assigning an IP Address From the Console Port 12 Assigning Basic Settings 13 LED Display 14 Technical Specifications 15 4 Regulatory Compliance All Exavera devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Exavera Technologies equipment, not expressly approved by Exavera Technologies, could void the user's authority to operate the equipment. When Exavera's devices are professionally installed, the Radio Frequency Output Power will not exceed the maximum allowable limit for the country of operation. Antennas: Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications, or attachments could cause damage and may violate regulations. Country Approvals Regulatory markings are applied to the device signifying the radio(s) are approved for use in the following countries: United States, Canada. Operation of the device without regulatory approval is illegal. Health and Safety Recommendations Warnings for the use of Wireless Devices Please observe all warning notices with regard to the usage of wireless devices Potentially Hazardous Atmospheres You are reminded to observe restrictions on the use of radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles (such as grain, dust, or metal powders) and any other area where you would normally be advised to turn off your vehicle engine. Safety in Hospitals Wireless devices transmit radio frequency energy and may affect medical electrical equipment. When installed adjacent to other equipment, it is advised to verify that the adjacent equipment is not adversely affected. FCC / EU RF Exposure Guidelines Safety Information The device complies with internationally recognized standards covering Specific Absorption Rate (SAR) related to human exposure to electromagnetic fields from radio devices. Reducing RF Exposure—Use Properly It is advisable to use the device only in the normal operating position. 5 Remote and Standalone Antenna Configurations To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons. Power Supply Use only an Exavera approved power supply Operation in the US The use on UNII (Unlicensed National Information Infrastructure) Band 1 5150-5250 MHz is restricted to indoor use only, any other use will make the operation of this device illegal. The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited by firmware. Radio Frequency Interference Requirements—FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection …

Text truncated - open the document above for the full version.

Cover Letter(s)

DATE : 2007-03-16 Equipment Authorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: T2RVR320 Product Name: VR-310, VR-320 Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operational description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 16 th Day of March 2007 By: _ _ _Jason Nixon___ Signature Printed Title: Telecom/Wireless Specialist On behalf of: Exavera Technologies, Inc. Telephone: 603 570 4000 x 203

ID Label/Location Info

VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605BFE VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605BFF VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C00 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C01 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C02 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C03 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C04 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C05 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 06062100605C06 VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmouth, N H 03801 603-570-4000 www.exavera.com Made in NH, USA Input: 120V~ 5WMax IC: 6393A-VR320 FCC ID: T2RVR320 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. VeraRelay™ Model: VR-320 Exavera Technologies, Inc. 195 New Hampshire Ave, Suite 155, Portsmo…

Text truncated - open the document above for the full version.

Test Report

Test Report: 6W58614 Issue 2 Applicant: Exavera Technologies, Inc. 195 New Hampshire Avenue Suite 155 Portsmouth, NH 03801 Equipment Under Test: VeraRelay VR-320 &VR-310 FCC ID: T2R-VR310 In Accordance With: FCC Part 15, Subpart C, 15.249 Tested By: Nemko Canada Inc. 303 River Road, R.R. 5 Ottawa, Ontario K1V 1H2 Authorized By: Jason Nixon, Telecom Specialist Date: March 19, 2007 Total Number of Pages: 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Table Of Contents Section 1. Summary Of Test Results...................................................................................3 Section 2. Summary Of Test Data.......................................................................................4 Section 3. General Equipment Specification......................................................................5 Section 4. Powerline Conducted Emissions........................................................................6 Section 5. Radiated Emissions...........................................................................................11 Section 6. Block Diagrams..................................................................................................17 Section 7. Test Equipment List..........................................................................................18 Page 2 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Section 1. Summary Of Test Results General All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 15.249. All tests were conducted using measurement procedure ANSI C63.4-2003. Radiated Emissions were made on an open area test site. A description of the test facility is on file with the FCC. THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See “ Summary of Test Data”. TESTED BY: _____ ______ Xu Jin, Wireless Specialist Nemko Canada Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Page 3 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Section 2. Summary Of Test Data Summary Of Test Data Name Of Test Para. No. Result Power line Conducted Emissions 15.207(a) Complies Radiated Emissions 15.249 Complies Test Conditions: Indoor Temperature: 21°C Humidity: 50% Outdoor Temperature: -3°C Humidity: 60% Page 4 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Section 3. General Equipment Specification Manufacturer: Exavera Technologies Model No.: VeraRelay VR-320 & VeraRelay VR-310 Date Received In Laboratory: Jan 4, 2006 Frequency Range: Tx 907.8---922.8MHz Rx: 905.3---925.3MHz Modulation: FSK Power Source: 120VAC Antenna Information Integral Antenna Note: Customer declared that Model VeraRelay VR-310 and Model VeraRelay VR-320 have identical RF circuit and antenna. Therefore only Model VeraRelay VR-320 was tested. Page 5 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Section 4. Powerline Conducted Emissions Para. No.: 15.207 (a) Test Performed By: Xu Jin Date of Test: Jan. 10, 2006 Test Results: Complies. Measurement Data: See attached graph(s). Limits For Conducted Disturbance At The Mains Ports Of Class B Limits dB(μV) Frequency Range MHz Quasi-Peak Average Result 0.15 to 0.50 66 to 56 56 to 46 0.5 to 5 56 46 5 to 30 60 50 Complies. Note: 1. The lower limit shall apply at the transition frequency. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50MHz. 3. The test was performed using a peak detector. Page 6 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Conducted Disturbance at Mains Detailed Setup Photos Page 7 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Page 8 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Page 9 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Test Date: Jan 10, 2006 Engineer’s Name: Xu Jin Tested as per: Table Top Mains Input Voltage: 120VAC Mains Input Frequency: 60Hz Port Investigation Data Port under test: AC Mains Input Conductor Frequency (MHz) Detector Emission Level (dBuV) LISN Loss (dB) Cable Loss (dB) Result (dBuV) Limit (dBuV) Margin (dB) Quasi Peak 20.6 0.00 0.20 20.80 56.0 35.2 Neutral 1.1502 Average 15.5 0.00 0.20 15.74 46.0 30.3 Quasi Peak 19.8 0.00 0.19 19.99 56.0 36.0 Phase 1.1482 Average 15.0 0.00 0.19 15.19 46.0 30.8 Notes None Test Result Final Test Result: Pass Page 10 of 18 Nemko Canada Inc. FCC PART 15, SUBPART C, 15.249 PROJECT NO.:6W58614 Issue 2 EQUIPMENT: VeraRelay VR-320 & VR310 FCC ID: T2R-VR310 Section 5. Radiated Emissions Para. No.: 15.249 Test Performed By: Xu Jin Date of Test: Jan 10, 2006 Minimum Standard: 15.209&15.249 Band edge check should comply with 50dBc requirement. Radiated Emission should comply with …

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emissions Photos Conducted Disturbance at Mains Detailed Setup Photos

Contact Information

Applicant

Alexander T. Wilson(VP Product Management & Development)
[email protected]603-570-4000Fax: 603-570-4001

Technical Contact

Exavera Technologies Inc.Keith Hatfiels
[email protected]603-570-4000

195 New Hampshire Avenue · Portsmouth, New Hampshire · United States

Non-Technical Contact

Exavera Technologies Inc.
[email protected]603-570-4000

Test Firm

Nemko Canada Inc. (Ottawa)Charles Neal
[email protected]613-737-9680Fax: 613-737-9691

Technical Specifications

#Rule PartsFrequency RangePower Output
115C907.8 MHz - 922.8 MHz-
Confidentiality
Long Term

Other Applications from Exavera Technologies Inc.

RFID Reader - FCC ID T2RVF2200 - Exavera Technologies Inc.
T2RVF2200

RFID Reader

Sep 18, 2007

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Low Power Transceiver RFID Tag - FCC ID T2RVTS321 - Exavera Technologies Inc.
T2RVTS321

Low Power Transceiver RFID Tag

Mar 18, 2007

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
VERA T ASSET TAG, VTA 311 AND VTA 331 TRANSMITTER - FCC ID T2R-VTA311 - Exavera Technologies Inc.
T2R-VTA311

VERA T ASSET TAG, VTA 311 AND VTA 331 TRANSMITTER

Feb 20, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter