FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. D&T Inc./
  3. THCFS-L1903C

THCFS-L1903CLCD Display

D&T Inc.
LCD Display - FCC ID THCFS-L1903C - D&T Inc.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
May 15, 2012
Application Purpose
Original Equipment
Date of Application
May 15, 2012
Equipment Note
LCD Display
Company
D&T Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MONITOR FS-L1903C User manual (Rev.01) SMITHS HEIMANN www.smithsdetection.com Page | 2 Table of Contents Safety Instructions ......................................................................................... 5 Accessories ................................................................................................... 8 Power Connections ........................................................................................ 8 Monitor Connections ...................................................................................... 9 Mechanical Drawings ..................................................................................... 9 OSD Buttons ................................................................................................ 10 Power Managements ................................................................................... 11 Adjusting OSD ............................................................................................. 11 Signal connector Pin Assignments ............................................................... 14 Supported Signal Formats ............................................................................ 15 Specifications ............................................................................................... 18 Page | 3 FCC INFORMATION This LCD monitor unit has been tested and found to comply with the limits of a Class B digital Device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against interference. This monitor can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment. There is no guarantee that interference will not occur in a particular installation. If this equipment is found to cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by carrying out one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the distance between the LCD monitor and the subject of interference. 3. Plug the monitor into an outlet on a different electrical circuit than that to which the subject of Interference is connected. 4. Consult the dealer or an experienced radio/TV technician for help. NOTICES TO USER This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any Interference received, including interference that may cause undesired operation. FCC WARNING This LCD monitor generates or uses radio frequency energy. Changes or modifications to this LCD monitor may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose authority to operate this equipment if an unauthorized change or modification is made. Environmental information The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form. (a) For a Class B digital device or peripheral, the instructions furnished the user shall include the following or similar statement, placed in a prominent location in the text of the manual: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, Page | 4 Which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. ENVIRONMENTAL INFORMATION 1. Operating Conditions - Temperature: 0°C~ 40°C - Humidity: 5%~85% non-condensing 2. Transportation Conditions - Temperature: -20°C~ 60°C - Humidity: 5%~95% non-condensing 3. Storage Conditions - Temperature: -20°C~ 60°C - Humidity: 10%~85% non-condensing APPROVALS Safety 1. CE-LVD EN 60950-1:2006+A11:2009+A1:2010+A12:2011 EMC 1. CE-EMC EN 55022 Class B,EN55024 & EN61000-3-2/-3-3 2. FCC Part 15 Class B DISPOSAL INFORMATION Dispose of it as required by local ordinances or regulations. This equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for health and environment. In order to avoid the dissemination of those substances in the environment and to diminish the pressure on natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end-of-life equipment in a sound way. The crossed-out wheeled bin symbol invites you to use those systems. If you need more information on the collection, reuse and recycling syste…

Text truncated - open the document above for the full version.

Block Diagram

LED Driver PowerKeypad LVDS Panel Connector PW338x (Image processor) 8MBits Flash Memory DDR x 2 27 MHz I2C 24LC32 (EEPROM) DC/DC AD9984 5V STB 3.3V STB 1.8V STB RS-232 IN VGA IN DVI-I IN MAX232 LED Driver Board SMPS 115~230V (47Hz~63Hz) T-CON unit (LCD Panel) 30Bits RGB TMDS RS-232 RGB H/V HDMI Port Input Port #0 RxD0/TxD0 24V(LED Power) Dimming On/Off H/V Sync 24V(LED Power) Sub U-com On signal I2C 8 bits 2ch LVDS 107.5MHz 28.322 MHz 20.000 MHz

Cover Letter(s)

Date: May 15, 2012 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 c.c. Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Ms. Misoh Kim/Application Examiner of UL-Korea, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Ms. Misoh Kim of UL- Korea on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Korea as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely, REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database.

Cover Letter(s)

D&T Inc. 59-9, Jang-Dong, Yuseong-Gu, Daejeon City, Korea, 305-343 Tel : +82(42)360-8000 Fax : +82(42)360-8005 CONFIDENTIALITY REQUEST for FCC ID: THCFS-L1903C Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 May 15, 2012 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, D&T Inc. requests confidentiality for the following products: FCC ID Number Product Title/Model THCFS-L1903C 19” Color TFT LCD Monitor / FS-L1903C The following exhibits contain trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our product. This material is not customarily available to the general public and we request that it be withheld from public inspection. We request that the following information submitted be held permanent confidential treatment. Permanent Confidential Request -. Circuit Diagram If you have any questions, please feel free to contact me at the address shown below. Sincerely,

External Photos

Project Number: 12CA20126 File Number TC8312 Page 1 of 2 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. 1. FCC Test Report_12CA20124_Dir_D&T_LCD Monitor_FS_L1903CEUT Photos Front View Project Number: 12CA20126 File Number TC8312 Page 2 of 2 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Rear View

ID Label/Location Info

Project Number: 12CA20126 File Number TC8312 Page 1 of 2 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. 1. Equipment Marking Plate: Project Number: 12CA20126 File Number TC8312 Page 2 of 2 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. 2. Label Location: Product Label Location

Internal Photos

Project Number: 12CA20126 File Number TC8312 Page 1 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. EUT Photos Inside View Project Number: 12CA20126 File Number TC8312 Page 2 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. LCD Panel Front View Project Number: 12CA20126 File Number TC8312 Page 3 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. LCD Panel Rear View Project Number: 12CA20126 File Number TC8312 Page 4 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 5 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 6 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 7 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 8 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 9 of 9 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL.

Operational Description

< Operation description for FS-L1903C> Connect DVI or VGA input signal and AC power cord to the FS-L19 03C Powered on with On/Off switch, t hen Power is supplied to SMPS. SMPS supply LED Driver power and 5VSTB power to Led Driver and main board. Scaler(PW338x) controls all I/O function and outputs generated signal to the LCD Panel, then LCD panel displays the image.

Test Report

UL Korea, Ltd A not-for-profit organization dedicated 33 rd FL, Gangnam Finance Center, 737 to public safety and committed to Yeoksam-dong, Gangnam-gu, Seoul quality service for over 100 years 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Underwriters Laboratories Inc. www.ul.com/emc www.ulk.co.kr Project:12CA20126 File: TC8312 Report: 12CA20126-CE Date:March 26, 2012 Model:FS-L1903C Electromagnetic Compatibility Test Report For LCD display D&T Inc. Daedeok Valley, 59-9, Jang Dong, Yuseong Gu, Daejeon, Korea, 305-343 Copyright  2005 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Only those products bearing the UL Mark should be considered as being covered by UL. Project Number: 12CA20126 File Number TC8312 Page 2 of 14 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Summary of Test Results: The following tests were performed on a sample submitted for evaluation of compliance 47 CFR Part 15.107 (a) / 47 CFR Part 15.109 (g) Class B. Test # Test Name Test Requirement/Specification Compliant Not Compliant See Remark 1 AC Power line Conducted Emission Test X - - 2 Radiated Emission Test X - - No modifications were made to the EUT in order to achieve and maintain compliance to the standards described in this report. Conclusion: The tests listed in the Summary of Testing section of this report have been performed as a witness testing and the results recorded by UL Korea Ltd. in accordance with the procedures stated in each test requirement and specification. The test list was determined by the Applicant as being applicable to the Equipment Under Test. As a result, the subject product has been verified to comply or not comply as noted in the Summary of Testing with each test specification. The test results relate only to the items tested. The equipment under test has Met the technical requirements Met the technical requirements under the limited condition Not met the technical requirements Tested by Sung Hoon Baek, Project Engineer Reviewed by Jeawoon, Choi, Senior Project Engineer UL Verification Services- 3014ASEO UL Verification Services- 3014ASEO UL Korea Ltd. UL Korea Ltd. Apr 30, 2012 Apr 30, 2012 Project Number: 12CA20126 File Number TC8312 Page 3 of 14 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Test Report Details Test report No: 12CA20126-CE File No: TC8312 Tests Performed By: UL Korea Ltd. 33 rd FL. GFC Bldg. 737 Yeoksam-dong, Kangnam-ku, Seoul, 135-984, Korea Test Site: CHUNGBUK TECHNOPARK 685-3 Yangcheong-ri, Ochang-eub,Cheongwon-kun,Chungbuk- province,Republic of Korea The test facility was deemed to have the environment and capabilities necessary to perform the tests included in the test package. Applicant: D&T Inc. Daedeok Valley, 59-9, Jang Dong, Yuseong Gu, Daejeon, Korea, 305-343 Manufacturer: D&T Inc. Daedeok Valley, 59-9, Jang Dong, Yuseong Gu, Daejeon, Korea, 305-343 Factory: D&T Inc. Daedeok Valley, 59-9, Jang Dong, Yuseong Gu, Daejeon, Korea, 305-343 Applicant Contact: Mr. Kyutae Park Phone: 82-42-360-8000 E-mail: [email protected] Product Type: LCD display Model Number: FS-L1903C Multilisting model number: N/A The manufacturer has declared to all the multiple model names into the basic model without any further evaluation by UL. Trademark: N/A Product standards: FCC Part 15 Subpart B Test Procedure: ANSI C63.4 : 2003 Sample Serial Number: N/A Sample Receive Date: Apr 06, 2012 Testing Start Date: Apr 13, 2012 Date Testing Complete: Apr 18, 2012 Test Report Date: Apr 27, 2012 Overall Results: Pass UL Korea Ltd. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. UL Korea Ltd. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from UL Korea Ltd. issued reports. Project Number: 12CA20126 File Number TC8312 Page 4 of 14 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. REPORT DIRECTORY 1. GENERAL PRODUCT DESCRIPTION: ______________________________________________ 5 1.1 EQUIPMENT DESCRIPTION: ________________________________________________ 5 1.2 DETAILS OF EQUIPMENT UNDER TEST (EUT): _______________________________ 5 1.3 TECHNICAL DATA: _________________________________________________________ 5 1.4 EUT INTERNAL OPERATING FREQUENCY: __________________________________ 6 1.5 TECHNICAL DESCRIPTIONS AND DOCUMENTS: _____________________________ 6 1.6 EQUIPMENT MARKING PLATE OF PRODUCT: _______________________________ 6 2. TEST CONDITION: _______________________________________________________________ 7 2.1 EQUIPMENT USED DURING TEST: ___________________________________________ 7 2.2 INPUT/OUTPUT PORTS: _____________________________________________________ 7 2.3 POWER INTERFACE: _______________________________________________________ 7 2.4 TEST OPERATING MODE: __________________________________________________ 8 2.5 MODES OF VIDEO RESOLUTION: __________________________…

Text truncated - open the document above for the full version.

Test Setup Photos

Project Number: 12CA20126 File Number TC8312 Page 1 of 3 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Figure 1. Conducted Emission Test Setup Project Number: 12CA20126 File Number TC8312 Page 2 of 3 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Figure 2. Photo of Radiated emission test setup for 30MHz to 1GHz Project Number: 12CA20126 File Number TC8312 Page 3 of 3 Model Number: FS-L1903C Client Name: D&T Inc. UL Korea, Ltd. 33 rd FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007 Only those products bearing the UL Mark should be considered as being covered by UL. Figure 3. Photo of Radiated emission test setup for 1GHz to 2GHz

Contact Information

Applicant

Park Kyutae(Principal Research Engineer)
[email protected]+82-42-360-8000Fax: +82-42-360-0830

Technical Contact

UL Korea Ltd.Sunghoon Baek
[email protected]+82-2-2009-9345

33 floor, Gangnam Finance Center, 737, Yeoksam-don · Seoul · South Korea

Non-Technical Contact

UL Korea Ltd.Sunghoon Baek
[email protected]+82-2-2009-9345

Test Firm

CHUNGBUK TECHNOPARKYoung Choi
[email protected]82-43-219-5871Fax: 82-43-219-5899

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from D&T Inc.

OS-1000CW - FCC ID THCOS-1000CW - D&T Inc.
THCOS-1000CW

OS-1000CW

Jun 26, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charger - FCC ID THCQWC-A800 - D&T Inc.
THCQWC-A800

Wireless Charger

Jun 02, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
42" Color TFT LCD Monitor (Model: FS-A4206C) - FCC ID THCFS-A4206 - D&T Inc.
THCFS-A4206

42" Color TFT LCD Monitor (Model: FS-A4206C)

Mar 08, 2012

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
55" Color TFT LCD Monitor for building-in - FCC ID THCFS-S5501F - D&T Inc.
THCFS-S5501F

55" Color TFT LCD Monitor for building-in

Jun 16, 2011

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
23" Color TFT LCD Monitor - FCC ID THCFS-S2301F - D&T Inc.
THCFS-S2301F

23" Color TFT LCD Monitor

Jun 08, 2010

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral