THCQWC-A800Wireless Charger

D&T Inc.
Wireless Charger - FCC ID THCQWC-A800 - D&T Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jun 02, 2021
Application Purpose
Original Equipment
Date of Application
Jun 02, 2021
Equipment Note
Wireless Charger
Frequency Range
0.11000000 - 0.20000000
Company
D&T Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless Charging Pad Input Output Dimension QWC-A800 Micro-USB, DC 5V/2A 5W ( 5V / 1A) 69mm*9mm Compatibility 1.Qi-enabled devices up to 5W 2.Any Qi-compatible smartphones Micro-USB Port How to charge your devices. Connect Micro-USB cable with Charging Pad Insert Micro-USB connector of charging cable to Micro-USB port of charging pad Connect with Power Supply Connect charging cable with charging pad to any power supply for charging. PRODUCT GUIDE Caution Avoid dropping Do not disassemble No metal object between devices and wireless charging stand Thick protective case 5mm or a case includes magnet or metallic material, may not allow proper charging function. Keep wireless charging stand away from any liquids or moisture The maximum ambient temperature during use of this product must not exceed 45°C. Do not place device in fire or other excessively hot environments. Only use dry cloth or brush to clean this product. Do not use if visible defects are observed on the wireless charging stand. Warning Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC Statements This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. **Thick protective case 5mm or a case includes magnet or metallic material, may not allow proper charging function. 1. 5W Qi Changing pad 2. A 3-ft micro-USB to USB charging cable What is in the box? 3. User Manual Get to know your 5W Qi wireless charging pad Begin to charge Do not place any credit card on the charging device. Place your smartphone or any Qi-enabled device on the center of the charging pad Wireless charger 5W Model: QWC-A800 These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any changes or modifications to equipment not expressly approved by the party responsible for compliance could void use's authority to operate the equipment. The antenna(s) used for this device must be installed to provide a separation distance of a least 15 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Need help? We’re here for you every day from 7 a.m. – 9 p.m. South Korea, Give us a call at 82-42-360-8100 If there is any foreign object detected, LED indicator will be flashing. Remove any foreign object (if any) Example: Magnet or holder

Cover Letter(s)

Rev 11/20/07 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea Tel No : +82-42-360-8000 Fax No : +82-42-360-0830 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: THCQWC-A800 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematics Parts List Operational description QWC-A800_Block Diagram.pdf QWC-A800_Schematic.pdf QWC-A800_Part List.pdf QWC-A800_Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Kyutae Park / Principal Research Engineer D&T Inc.

Cover Letter(s)

26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea Tel No : +82-42-360-8000 Fax No : +82-42-360-0830 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: May 6, 2021 SUBJECT: FCC Application for (FCC ID : THCQWC-A800) To Whom It May Concern: We, the undersigned, hereby authorize Kim Gwan-Yong at CTK on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by CTK on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Kyutae Park/ Principal Research Engineer D&T Inc.

External Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT External Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com

ID Label/Location Info

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Label and Location

Internal Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT Internal Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com ANTENNA

RF Exposure Info

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 1 of 8 This Report shall not be reproduced except in full without the written approval of CTK RF EXPOSURE EVALUATION Applicant D&T Inc. Applicant Address 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea FCC ID THCQWC-A800 Product Description Wireless Charger Basic model QWC-A800 Variant Model name - Operating Frequency 110 kHz - 200 kHz Antenna type Coil Antenna Type of Modulation AM Power Source DC 5 V (Adapter & Micro 5pin) RF Power setting Referred the measuring instrument from manufacturer CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 2 of 8 This Report shall not be reproduced except in full without the written approval of CTK CONTENTS 1. Introduction ............................................................................................................ 3 2. Test Set-up .............................................................................................................. 3 2.1 EUT Position ..................................................................................................... 4 2.2 Test configurations ............................................................................................ 4 2.3 Peripheral Devices ............................................................................................. 4 2.4 Measurement procedure ..................................................................................... 4 3. Test Result .............................................................................................................. 5 4. Test Setup Photos ..................................................................................................... 6 5. APPENDIX A – Test Equiment Used For Tests ................................................................ 8 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 3 of 8 This Report shall not be reproduced except in full without the written approval of CTK 1. Introduction This document is prepared to show compliance with the RF Exposure requirements as required in §1.1310 of the FCC Rules and Regulations. The limit for Maximum Permissible Exposure (MPE), specified in FCC §1.1310, is listed in Table 1. According to FCC §1.1310: the criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified in §1.1307(b). Table 1—Limits for Maximum Permissible Exposure (MPE) f = frequency in MHz. * = Plane-wave equivalent power density. Per the guidance of FCC Rule, Emissions between 9 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. 2. Test Set-up CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 4 of 8 This Report shall not be reproduced except in full without the written approval of CTK 2.1 EUT Position Note : ⓐ : Front, ⓑ : Left, ⓒ : Right, ⓓ : Rear, ⓔ : Top, ⓕ : Bottom 2.2 Test configurations In order to check all kinds of possible configurations, EUT was evaluated with appropriate client and under each charging condition as below table. EUT Mode Description Charging (Transmitting mode) Less than 1 % of Battery Less than 50 % of Battery Less than 100 % of Battery 2.3 Peripheral Devices Device Manufacturer Model No. Serial No. AC/DC ADAPTER RFTECH THAI NGUYEN CO.,LTD EP-TA21KBK R37K9D25VY5RT3 Mobile phone SAMSUNG Electronics Co., Ltd. SM-G955N (Galaxy S8+) R39J40GS35 2.4 Measurement procedure CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 5 of 8 This Report shall not be reproduced except in full without the written approval of CTK a) The measurement was investigated between the edge of the charger and center of the field b) Maximum E-field and H-field measurements were made on each of six sides of the EUT that could come in contact with a user. six sides are defined as follows: Front (ⓐ), Left(ⓑ), Right(ⓒ), Rear(ⓓ), Top(ⓔ) and Bottom(ⓕ) Refer to the test set-up position section 2.1 above. c) According to the guidance of KDB 680106 D01 v03 test distance was 15 cm measured from the center of the probe(s) to the edge of the device d) Equipment approval considerations item 5.b) of KDB 680106 D01 v03 (1) Power transfer frequency is less than 1 MHz. - DC 5 V, 110 kHz ~ 200 kHz (2) Output power from each primary coil is less than or equal to 15 watts. - DC 5 V : 5 W (3) The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. - The transfer system includes only single primary coils. (4) Client device is placed directly in contact with the transmitter. - Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). - Not Applicable. (6) The aggregate H-field strengths anywhere at or beyond 15 cm surrounding the device, and 20 cm away from the surface from all coils that by design can simultaneously transmit, and while those coils are simultaneously energized, are demonstrated to be less than 50% of the applicable MPE limit. - Refer to following worst test result (For more detail, please refer to section 3) 1) The worst E-Field Strength levels at 15 cm < 50 % of the MPE E-Field Strength limit 614 V/m. - 5 V Less than 1 % of Battery : 2.60 V/m < 307 V/m 2) The worst H-Field Strength levels at 15 cm < 50 % of the MPE E-Field Strength limit 1.63 A/m. - 100 % full charging of Battery : 0.43 A/m < 0.815 A/m 3. Test R…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (1) / (24) Pages QF-QP15-03 R108 Rev.0 1. Client ◦ Name : D&T Inc. ◦ Address : 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea ◦ Date of Receipt : 2021-04-21 2. Manufacturer ◦ Name : D&T Inc. ◦ Address : 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea 3. Use of Report : For FCC Certification 4. Test Sample / Model: Wireless Charger / QWC-A800 5. Date of Test : 2021-04-28 to 2021-04-29 6. Test Standard(method) used : FCC 47 CFR part 15 subpart C 15.209 ANSI C63.10-2013 7. Testing Environment: Temp.: (23 ± 1) °C, Humidity: (48 ± 5) % R.H. 8. Test Results : Compliance The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full. Affirmation Tested by Gwanyong Kim: (Signature) Technical Manager Young-taek Lee: (Signature) 2021-04-29 Republic of KOREA CTK Co., Ltd. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (2) / (24) Pages QF-QP15-03 R108 Rev.0 REPORT REVISION HISTORY Date Revision Page No 2021-04-29 Issued (CTK-2021-01663) all This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (3) / (24) Pages QF-QP15-03 R108 Rev.0 CONTENTS 1. General Product Description ....................................................................................... 4 1.1 Client Information ............................................................................................. 4 1.2 Product Information ........................................................................................... 4 1.3 Peripheral Devices ............................................................................................. 4 2. Facility and Accreditations .......................................................................................... 5 2.1 Test Facility ...................................................................................................... 5 2.2 Laboratory Accreditations and Listings .................................................................. 5 2.3 Calibration Details of Equipment Used for Measurement .......................................... 5 3. Test Specifications .................................................................................................... 6 3.1 Standards ........................................................................................................ 6 3.2 Mode of operation during the test ........................................................................ 6 3.3 Maximum Measurement Uncertainty .................................................................... 6 4. Technical Characteristic Test ....................................................................................... 7 4.1 Antenna requirement ......................................................................................... 7 4.2 Field strength of fundamental and Spurious emission ............................................. 8 4.3 Emission Bandwidth ......................................................................................... 17 4.4 AC Conducted Emissions .................................................................................. 19 5. APPENDIX A – Test Equipment Used For Tests ............................................................. 24 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (4) / (24) Pages QF-QP15-03 R108 Rev.0 1. General Product Description 1.1 Client Information Company D&T Inc. Contact Point 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, 34113, Korea Contact Person Name : Kyutae Park E-mail : [email protected] Tel : +82-42-360-8000 Fax : - 1.2 Product Information FCC ID THCQWC-A800 Product Description Wireless Charger Basic model QWC-A800 Variant Model name - Operating Frequency 110 kHz - 200 kHz RF Output Power 72.2 dBμV/m @ 3 m Antenna type Coil Antenna Type of Modulation AM Power Source DC 5 V (Adapter & Micro 5pin) RF Power setting Referred the measuring instrument from manufacturer Note : the above eut information was declared by the manufacturer 1.3 Peripheral Devices Device Manufacturer Model No. Serial No. Wireless charging tester BAECOAR WX0405M - CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (5) / (24) Pages QF-QP15-03 R108 Rev.0 2. Facility and Accreditations 2.1 Test Facility The measurement facility is located at (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea. 2.2 Laboratory Accreditations and Listings Country Agency Registration Number USA FCC 805871 CANADA ISED 8737A-2 KOREA NRRA KR0025 2.3 Calibration Details of Equipment Used for Measurement Test equipment and test accessories are calibrated on regular basis. The maximum time between calibrations is one year or what is recommended by the manufacturer, whichever is less. All test equipment calibrations are traceable to the Korea Research Institute of Standards and Science (KRISS), therefore, all test data recorded in this report is traceable to KRISS. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2021-01663 Page (6) / (24) Pages…

Text truncated - open the document above for the full version.

Test Setup Photos

CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page (1) / (5) Pages Test Setup Photo AC Power Line Emissions measurement CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page (2) / (5) Pages Radiated Emissions measurement 9 kHz to 30 MHz 30 MHz to 1 GHz CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page (3) / (5) Pages RF Exposure (E-Field & H-Field) Front Near CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page (4) / (5) Pages Left Right CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 17142, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page (5) / (5) Pages Top Bottom

Contact Information

Applicant

Park Kyutae(Principal Research Engineer)
[email protected]+82-42-360-8000Fax: +82-42-360-0830

Test Firm

CTK Co., Ltd.Young-Joon Park
[email protected]82-31-339-9871Fax: 82-31-624-9501

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.2 MHz-
Confidentiality
Long Term

Other Applications from D&T Inc.

OS-1000CW - FCC ID THCOS-1000CW - D&T Inc.
THCOS-1000CW

OS-1000CW

Jun 26, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
LCD Display - FCC ID THCFS-L1903C - D&T Inc.
THCFS-L1903C

LCD Display

May 15, 2012

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
42" Color TFT LCD Monitor (Model: FS-A4206C) - FCC ID THCFS-A4206 - D&T Inc.
THCFS-A4206

42" Color TFT LCD Monitor (Model: FS-A4206C)

Mar 08, 2012

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
55" Color TFT LCD Monitor for building-in - FCC ID THCFS-S5501F - D&T Inc.
THCFS-S5501F

55" Color TFT LCD Monitor for building-in

Jun 16, 2011

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
23" Color TFT LCD Monitor - FCC ID THCFS-S2301F - D&T Inc.
THCFS-S2301F

23" Color TFT LCD Monitor

Jun 08, 2010