TM73250CBEM2Blood Glucose plus Blood Pressure Minitor

TAIDOC TECHNOLOGY CORP.
Blood Glucose plus Blood Pressure Minitor - FCC ID TM73250CBEM2 - TAIDOC TECHNOLOGY CORP.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Mar 11, 2008
Application Purpose
Original Equipment
Date of Application
Mar 11, 2008
Equipment Note
Blood Glucose plus Blood Pressure Minitor
Frequency Range
2402.00000000 - 2480.00000000
Company
TAIDOC TECHNOLOGY CORP.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Version 2 2006/07/04 Table of Contents BEFORE YOU START 04 Warnings and Precautions 04 Intended Use 05 Health Information 06 ABOUT THIS SYSTEM 08 Content of the System 08 Device Overview 09 Button Function & Pressure Cuff 11 LCD Display Description 13 Test Strip Description 14 PREPARATIONS BEFORE USE 16 Battery Installation and Replacement 16 Setting the Monitor 18 HOW TO MEASURE BLOOD GLUCOSE 20 Important Information and Possible Interferences 21 Coding the Monitor 22 Checking the Code 23 Testing With Control Solution 24 Getting a Drop of Blood 27 Taking a Reading 29 Comparing With Laboratory Results 31 HOW TO MEASURE BLOOD PRESSURE 32 Suggestions before Measuring 33 Applying the Pressure Cuff 34 Proper Measurement Position 35 Taking a Reading 36 HOW TO USE THE MEMORY FEATURES 37 Viewing Memory in the Monitor 37 Viewing Results on a Personal Computer 38 2 Deleting memory 39 HOW TO TAKE CARE OF YOUR MONITOR 40 Cleaning 40 Storage 40 ERROR MESSAGE 41 TROUBLESHOOTING 42 SPECIFICATIONS 44 SYMBOLS INFORMATION 45 3 * Before testing, please read all instructions and practice the test. * Be sure to keep this manual for future reference. € Warnings and Precautions ƒ The CLEVER CHEK TD-3250 System is designed for use on individuals age 16 and above. It shall NOT be used: 1. to diagnose newborns with diabetes. 2. on infants or persons who cannot communicate. ƒ This device does not serve as a cure of any symptoms or disease. The data measured are only for reference. Always consult your physician to have the results interpreted. ƒ This device is not able to measure in the presence of common arrhythmia, such as arterial or ventricular premature beats or arterial fibrillation. It may produce reading error. ƒ Use of the device near a mobile phone or microwave oven may cause inaccurate results. ƒ Do not use the device for purposes other than measuring blood glucose and blood pressure for humanbeings. ƒ Do not wrap the pressure cuff on anything besides your arm. 4 BEFORE YOU START € Intended Use What it is: The CLEVER CHEK TD-3250 system is a 2 in 1 system designed to measure blood glucose outside of human body and to measure blood pressure non-invasively. The system performs only one function at a time to avoid any interference problems. The system consists of the CLEVER CHEK TD-3250 monitor, test strips, and check & code strip. The system also comes with control solutions for quality control. How it works: Blood glucose is tested using an Amperometric Biosensor. Capillary action at the absorbent hole of the test strip draws a small amount of blood into the reaction chamber, and then the reading is displayed after 10 seconds. Blood pressure is measured non-invasively at the upper arm based on the oscillometric method. This user’s manual contains important information that you must know about your system. Please read it carefully. For other questions regarding this system, please contact: U.S.A. representative Chunming Shih 4331 Stevens Battle Lane, Fairfax, VA 22033 Customer Care Line: (703) 591-4934 Hours of Operation: 9 am- 4 p.m. EST (14:00 - 21:00 GMT) At all other times, you should contact your health care professional for assistance. A warranty registration card is included with your system. Please complete it and mail it to us; if you prefer to fill it out online, please visit http://www.taidoc.com 5 BEFORE YOU START € Health Information Blood Glucose Blood glucose monitoring plays an important role in diabetes control. A long-term study shows that keeping blood glucose levels close to normal can reduce the risk of diabetes complications by up to 60 %.* The results you get with the CLEVER CHEK TD-3250 can help you and your healthcare professional monitor and adjust your treatment plan to gain better control of your diabetes. The American Diabetes Association (ADA) recommends that you keep your blood sugar levels at: Time of day ADA recommendation Before meals 80-120 mg/dL / 4.5-6.7 mmol/L 1-2 hours after meals Less than 180 mg/dL / 10 mmol/L Bedtime 100-140 mg/dL / 5.6-7.8 mmol/L Source: American Diabetes Association (2005). Standards of medical care in diabetes. Clinical Practice Recommendations 2005. Diabetes Care, 28(Suppl): S4–S36. *Reference: American Diabetes Association: Position Statement on the Diabetes Control and Complications Trial (1993). 6 BEFORE YOU START Blood Pressure Clinical studies show that the adult diabetes is often accompanied by elevated blood pressure. People with diabetes can reduce their heart risk by managing their blood pressure along with diabetes treatment*. Knowing your routine blood pressure trend tells whether your body is in good condition or not. Human blood pressure naturally increases after reaching middle age. This symptom is a result of continuous aging of the blood vessel. Further causes include obesity, lack of exercise, and cholesterol (LDL) adhering to the blood vessels. Rising of blood pressure accelerates hardening of the arteries, and the body becomes more susceptible to apoplexy and coronary infarction. The WHO (world health organization) published the guideline of blood pressure range: Source: 1999 WHO/ISH guidelines for the management of hypertension *Reference: American Diabetes Association: The Diabetes-Heart Disease Link Surveying Attitudes, Knowledge and Risk (2002) 7 € Content of the System 1 Blood glucose and blood pressure monitor x1 6 Sterile lancets X25 2 Pressure cuff x1 7 Lancing device x1 3 Test strip X25 8 Quick guide x1 4 Check & code strip X1 9 User’s manual x1 5 Taidoc control solutions X2 V Sporty bag x1 These products have been designed, tested, and proven to work together as a system to produce accurate blood glucose test results. Use only CLEVER CHEK TD-3250 test strips and control solution with your CLEVER CHEK TD-3250 Monitor. Caution! Check your system to be sure that it is unopened prior to use and that it contains all parts listed above. If either of these conditions occurred, please return your system to the place of pur…

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 02 Declaration of Authorization We Name: Taidoc Technology Corp. Address: 6F, No. 127, Wugong 2nd Rd., Wugu Taipei County 248, Taiwan City: Wugu Taipei County,TAIPEI HSIEN Country: Taiwan Declare that: Name Representative of agent: Wayne Lee (1) Agent Company name: Taidoc Technology Corp. Address: 6F, No. 127, Wugong 2nd Rd., Wugu Taipei County 248, Taiwan City: Wugu Taipei County,TAIPEI HSIEN Country Taiwan is authorized to apply for Certification of the following product(s): Product description: Blood Glucose plus Pressure Minitor Type designation: TD325xC(x=0~9) Trademark: CLEVER CHEK on our behalf. Date: 2008/01/11 City: Wugu Taipei County,TAIPEI HSIEN Name: Paul Tsai (2) Function: Product Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

TaiDoc Technology Corp. 6F, No.127, Wugong 2nd Rd., Wugu,Taipei County 248, Taiwan, Tel:+886-2-6635-8080 Fax:+886-2-6635-5959 http://www.TaiDoc.com.tw Jan. 09, 2008 Federal Communications Commission Authorization and Evaluation Division FCC ID: TM73250CBEM2 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: 1. Schematics 2. Block Diagram 3. Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Wayne Lee/Project Manger Taidoc Technology Corp.

External Photos

Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw APPENDIX 2 EXTERNAL OF EUT Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw All of EUT Adaptor Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Front View of EUT Back View of EUT Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Side View of EUT – 1 Side View of EUT – 2

ID Label/Location Info

FCC ID LABEL FORMAT AND LOCATION Applicant: Taidoc Technology Corp. FCC ID: TM73250CBEM2

Internal Photos

Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw APPENDIX 3 INTERNAL OF EUT Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Open View of EUT Internal of EUT – 1 Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 2 Internal of EUT – 3 Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 4 Internal of EUT – 5 Antenna

RF Exposure Info

Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw RF EXPOSURE „ Standard Applicable According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. „ Measurement Result: This is a portable device and the Max peak output power is 3.73dBm (0.00236 W) lower than low threshold 60/fGHz mW (24.48mW), d<2.5cm in general population category; The SAR measurement is not necessary.

Test Report

Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 Page: 1 of 55 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the con- tent or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意 此條款列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面 許可,不可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Product Name: Blood Glucose plus Blood Pressure Monitor Brand Name: N/A Model Name: TD-325XC, TD-325XD, TD-325XE (X=0~9) Model Difference: X = 0~9 represents for different colors. Model TD-325XC with a Bluetooth key and is able to transfer data by PCL mode; whereas TD-325XD and TD-3250E without this function. FCC ID: TM73250CBEM2 Report No.: ER/2007/A0027 Issue Date: Dec. 26, 2007 FCC Rule Part: §15.247 Prepared for: Taidoc Technology Corp. 6F, No.127, Wugong 2nd Rd., Wugu Township, Taipei County, Taiwan Prepared by: SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei County, Taiwan. Note: This report shall not be reproduced except in full, without the written approval of SGS Taiwan Ltd. This docu- ment may be altered or revised by SGS Taiwan Ltd. person- nel only, and shall be noted in the revision section of the document. Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 Page: 2 of 55 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw VERIFICATION OF COMPLIANCE Applicant: Taidoc Technology Corp. 6F, No.127, Wugong 2nd Rd., Wugu Township, Taipei County, Taiwan Equipment Under Test: Blood Glucose plus Blood Pressure Monitor Brand Name: N/A FCC ID Number: TM73250CBEM2 Model No.: TD-325XC, TD-325XD, TD-325XE (X=0~9) Model Difference: X = 0~9 represents for different colors. Model TD-325XC with a Blue- tooth key and is able to transfer data by PCL mode; whereas TD-325XD and TD-3250E without this function. File Number: ER/2007/A0027 Date of test: Dec. 17, 2007 ~ Dec. 24, 2007 Date of EUT Received: Dec. 17, 2007 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. The test data, data evaluation, test proce- dures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.247 The test results of this report relate only to the tested sample identified in this report. Test By: Date Dec. 26, 2007 Bangde Liu/Engineer Prepared By: Date Dec. 26, 2007 Elisa Chen/Asst. Supervisor Approved By: Date Dec. 26, 2007 Vincent Su/Manager Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 Page: 3 of 55 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Version Version No. Date 00 Dec. 26, 2007 Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 Page: 4 of 55 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the conte…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw APPENDIX 1 PHOTOGRPHS OF SET UP Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Radiated Emission Set up Photo Report No ER/2007/A0027 FCC ID: TM73250CBEM2 Issue Date: Dec. 26, 2007 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. 此報告是遵循本公司訂定之通用服務條款所製作發放, 請注意此條款 列印於背面,亦可在www.sgs.com 中查閱。將本公司之義務,免責,管轄權皆明確規範之。除非另有說明,此報告結果僅對檢驗之樣品負責。本報告未經本公司書面許可,不 可部份複製。對本報告內容或外觀之任何未經授權之變更、偽造、竄改皆屬非法,違犯者將會被依法追訴。 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 台北縣五股工業區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Conducted Emission Set up Photo

Contact Information

Applicant

Jim Jan(Project Management Specialist)
[email protected]+886-2-66258188Fax: +886-2-66258810

Technical Contact

SGS Taiwan Ltd.Vincent Su
[email protected]

134, Wu Kung Rd., Wuku Industrial Zone · Taipei County · Taiwan

Test Firm

SGS TAIWAN LTD.NELSON BAI
[email protected]886-2-22993279Fax: 886-2-22999489

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.36 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This is a portable device. The device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from TAIDOC TECHNOLOGY CORP.

Blood Pressure Monitoring System - FCC ID TM73128B01 - TAIDOC TECHNOLOGY CORP.
TM73128B01

Blood Pressure Monitoring System

Jun 05, 2022

Equipment Class

DTS - Digital Transmission System
TD-9030A - FCC ID TM79030A01 - TAIDOC TECHNOLOGY CORP.
TM79030A01

TD-9030A

Jul 17, 2014

Equipment Class

DTS - Digital Transmission System
Handheld Pulse Oximeter - FCC ID TM78201BEM2 - TAIDOC TECHNOLOGY CORP.
TM78201BEM2

Handheld Pulse Oximeter

Jun 23, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Blood Glucose + Blood Pressure Monitoring System - FCC ID TM7326000M00 - TAIDOC TECHNOLOGY CORP.
TM7326000M00

Blood Glucose + Blood Pressure Monitoring System

Mar 17, 2008

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Blood Glucose Meter - FCC ID TM74111ABEM2 - TAIDOC TECHNOLOGY CORP.
TM74111ABEM2

Blood Glucose Meter

Jan 28, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter