TM7326000M00Blood Glucose + Blood Pressure Monitoring System

TAIDOC TECHNOLOGY CORP.
Blood Glucose + Blood Pressure Monitoring System - FCC ID TM7326000M00 - TAIDOC TECHNOLOGY CORP.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Mar 17, 2008
Application Purpose
Original Equipment
Date of Application
Mar 17, 2008
Equipment Note
Blood Glucose + Blood Pressure Monitoring System
Frequency Range
2405.00000000 - 2480.00000000
Company
TAIDOC TECHNOLOGY CORP.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Fora Comfort 2 in 1 Blood Glucose plus Blood Pressure Monitoring System Version 1.0 2007/09/03 01 2 IMPORTANT SAFETY INSTRUCTIONS READ THIS BEFORE USING The following basic safety precautions should always be taken. 1. Close supervision is necessary when the device is used by, on, or near children, handicapped persons or invalids. 2. Use the device only for the intended use described in this manual. 3. Do not use strips and control solutions which are not supplied by the manufacturer. 4. Do not use the device if it is not working properly, or if it has suffered any damage. 5. Before using any product to test your blood glucose, read all instructions thoroughly and practice the test. Do all quality control checks as directed and consult with a diabetes healthcare professional. KEEP THESE INSTRUCTIONS 02 3 Table of Contents BEFORE YOU START 05 Warnings and Precautions 05 Health Information 06 ABOUT THIS SYSTEM 08 Intended Use 08 Principle of Measurement 08 Alternative Site Testing (AST) 09 Content of the System 11 Appearance and Key Function of the Monitor 12 LCD Display 14 Appearance of the Test Strip 15 PREPARATIONS BEFORE USE 16 Battery Installation and Replacement 16 Setting the Monitor 18 HOW TO MEASURE BLOOD GLUCOSE 21 Coding the Monitor 22 Checking the Code 23 Checking the System with Control Solutions 24 Important Control Solution Information 25 Doing a Control Solution Test 26 Testing Your Blood Glucose 28 Special Message 35 Comparing Monitor and Laboratory Results 36 HOW TO MEASURE BLOOD PRESSURE 37 Suggestions before Measuring 37 Test Your Blood Pressure 38 HOW TO USE THE MEMORY FEATURES 40 Viewing Memory in the Monitor 40 Deleting memory 41 03 4 HOW TO TAKE CARE OF YOUR MONITOR 42 Cleaning 42 Storage 42 Monitor storage 42 Strip storage 43 Control storage 44 PROBLEM-SOLVING GUIDE 45 ERROR MESSAGE 46 Problem in Opertation 47 SPECIFICATIONS 49 04 5 BEFORE YOU START € Warnings and Precautions ƒ The Fora comfort 2 in 1 blood glucose plus blood pressure monitoring system is designed for use on individuals age 16 and above. It shall NOT be used: 1. To diagnose newborns with diabetes. 2. On infants or persons who cannot communicate. ƒ This device does NOT serve as a cure of any symptoms or disease. The data measured are only for reference. Always consult your physician to have the results interpreted. ƒ This device is NOT able to measure in the presence of common arrhythmia, such as arterial or ventricular premature beats or arterial fibrillation. It may produce reading error. ƒ Do NOT use the device for purposes other than measuring blood glucose and blood pressure for human beings. ƒ Do NOT wrap the pressure cuff on anything besides your arm. 05 6 € Health Information Blood Glucose Blood glucose monitoring plays an important role in diabetes control. A long-term study showed that keeping blood glucose levels close to normal can reduce the risk of diabetes complications by up to 60%* 1 . The results you get with the Fora comfort 2 in 1 blood glucose plus blood pressure monitoring system can help you and your healthcare professional monitor and adjust your treatment plan to gain better control of your diabetes. Time of day Plasma glucose range (mg/dL) for people without diabetes Your target range (mg/dL) Fasting and before meal *1a 70-110 mg/dL (3.9 – 6.1 mmol/L) 2 hours after meals *1b Less than 140 mg/dL (7.8 mmol/L) *1a: Sacks, DB in “Carbohydrates”, Burtis, CA, Ashwood, ER (ed), Tietz Textbook of Clinical Chemistry, Philadelphia, WB Saunders Company, 1999. *1b: ADA Clinical Practice Recommendations 2003 Please work with your doctor to determine a target range that works best for you. 06 7 Blood Pressure Clinical studies show that the adult diabetes is often accompanied by elevated blood pressure. People with diabetes can reduce their heart risk by managing their blood pressure along with diabetes treatment* 2 . Knowing your routine blood pressure trend tells whether your body is in good condition or not. Human blood pressure naturally increases after reaching middle age. This symptom is a result of continuous aging of the blood vessel. Further causes include obesity, lack of exercise, and cholesterol (LDL) adhering to the blood vessels. Rising of blood pressure accelerates hardening of the arteries, and the body becomes more susceptible to apoplexy and coronary infarction. The WHO (world health organization) published the guideline of blood pressure range: Source: 1999 WHO/ISH guidelines for the management of hypertension *2: American Diabetes Association: The Diabetes-Heart Disease Link Surveying Attitudes, Knowledge and Risk (2002) 07 8 ABOUT THIS SYSTEM € Intended Use The Fora Comfort TD-3260 2 in 1 Blood Glucose plus Blood Pressure Monitoring System is indicated for the quantitative measurement of glucose in fresh whole blood (capillary blood from the finger, the palm, the forearm, the upper-arm, the calf and the thigh) for self testing by persons with diabetes in the home or by healthcare professionals in healthcare facilities. The system is also intended to be used to measure non-invasively the systolic and diastolic blood pressure and pulse rate of an adult individual, over age 16, at home. € Principle of Measurement Blood glucose is based on the measurement of electrical current generated by the reaction of glucose with the reagent of the strip. The monitor measures the current and displays the corresponding blood glucose level. The strength of the current produced by the reaction depends on the amount of glucose in the blood sample. Blood pressure is measured non-invasively at the wrist based on the Oscillometric method. Both functions work separately (one measurement either blood glucose or blood pressure at a time) to avoid any interference problems. € Major Features The greatest feature of this system is that you can view results on the PC through wireless connection using Zigbee Gateway technology. It provides a simply way to transmit data into your PC. 08 9 € Altern…

Text truncated - open the document above for the full version.

External Photos

Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 32 of 41 APPENDIX 2 PHOTOGRAPHS OF EUT Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 33 of 41 All View of EUT Front View of EUT Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 34 of 41 Back View of EUT Top View of EUT Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 35 of 41 Side View of EUT-1 Side View of EUT-2 Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 36 of 41 Adaptor (Model number:GS2U-006-060)

Internal Photos

Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 37 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Open View of EUT – 1 Open View of EUT – 2 Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 38 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 1 Internal of EUT – 2 Antenna Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 39 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 3 Internal of EUT – 4 Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 40 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 5 Internal of EUT – 6 Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 41 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Internal of EUT – 7 -- End of Report --

Parts List/Tune Up Info

HIGH FREQUENCY SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 DATA SHEET Product specification – Jul 27, 2004 V.3 Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 2 www.yageo.com QUICK REFERENCE DATA DESCRIPTION VALUE Centre frequency (for different central frequency shifts) 2.45 GHz 02 type/03 type/Default/06 type/07 type Bandwidth >100 MHz Gain 4.1 dBi max. (depends on the special environment) VSWR 2.5 max. (depends on the special environment) Polarization Linear Azimuth beamwidth Omni-directional Impedance 50 Ω Power dissipation 1 W Operating temperature −55 to +85 °C Terminations NiSn Resistance to soldering heat 260 °C for 10 seconds (1) Bluetooth is a trademark owned by Telefonieaktiebolaget L M Ericsson, Sweden. The foil making process uses an environment- friendly aqueous-solvent technology that fully complies with today’s green-product design requirements. All terminations are lead-free. Packing materials can be recycled. ENVIRONMENTAL CARE DESCRIPTION This 2.45 GHz ceramic multilayer antenna has been designed to meet the requirements of the Bluetooth TM(1) and IEEE 802.11b/g wireless communications protocol. It consists of a rectangular block of low-dielectric ceramic material and is fabricated in a water-based non-toxic process. The antenna is capable of providing good connectivity using near 50 Ω microstrip directly onto the PC board. FEATURES • Designed for 2.45 GHz ISM-band • Simplifies antenna circuitry • NiSn lead-free terminations • Suitable for wave and reflow soldering • Supplied in tape on reel. APPLICATIONS • Telecommunications • Computing (PCs, printers, PDAs) • Wireless office data communications including WLAN • Consumer electronics (wireless headphones). Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 MECHANICAL DATA Fig.1. Component outline. L W IWA0011 T S 2 F C F C S 1 S 1 S 2 For dimensions see Table 1. Physical dimensions Table 1 antenna dimensions SYMBOL DETAILS DIMENSIONS (mm) L − 7.8 ±0.25 W − 3.6 ±0.20 T − 0.9 ±0.20 F feed termination 1.25 ±0.25 C − 0.4 ±0.20 S1 − 1.25 ±0.25 S2 − 1.25 ±0.25 2004 Jul 27 Rev.3 3 www.yageo.com Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 4 www.yageo.com Fig.2. Recommend dimension of solder lands IWA0012 L C C Antenna W F S 1 C S 2 C S 2 For dimensions see Table 2. FOOTPRINT DIMENSIONS Physical dimensions Table 2 The dimensions of antenna appearance SYMBOL DETAILS DIMENSIONS (mm) L − 9.0 ±0.1 W − 4.4 ±0.2 F feed pad 1.4 ±0.25 C − 0.8 ±0.20 S1 − 1.4 ±0.25 S2 − 1.6 ±0.25 ELECTRICAL CHARACTERISTICS DESCRIPTION VALUE Centre frequency (for different central frequency shifts) 2.45 GHz 02 type/03 type/Default/06 type/07 type Bandwidth >100 MHz Gain 4.1 dBi max. (depends on the special environment) VSWR 2.5 max. (depends on the special environment) Polarization Linear Azimuth beamwidth Omni-directional Impedance 50 Ω Power dissipation 1 W Operating temperature −55 to +85 °C Terminations NiSn Resistance to soldering heat 260 °C for 10 s Weight 0.0839 g/piece Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 5 www.yageo.com Physical dimensions Table 3 The dimensions of test board SYMBOL DETAILS DIMENSIONS (mm) L1 − 30 L2 − 10 W − 18 T − 0.8 T1 − 5.0 Fig.3. Typical FR4 test board. IWA0013 50 Ω transmisson line SMA connector Ground areaClear area L 1 L 2 W T Antenna chip T 1 For dimensions see Table 3. ANTENNA CHARACTERISTICS IN STANDRD TEST BOARD Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 6 www.yageo.com Fig.4 The measurements of typical SWR and return loss on standard test board . Pre-tuning reference only,after-tuning performance is depending on customer installation. Marker data: 1: Γ= −10 dB; f= 2.35 GHz 2: Γ= −10 dB; f= 2.56 GHz Marker data: 1: SWR= 2.5; f= 2.31 GHz 2: SWR= 2.5; f= 2.62 GHz 2.02.13.0 f (GHz) SWR 1.0 2.0 3.0 5.0 7.0 6.0 8.0 9.0 10.0 4.0 2.22.32.42.52.62.72.82.9 IWA0016 1 2 2.02.13.0 f (GHz) Γ (dB) −45 −40 −35 −25 −15 −20 −10 − 5 0 −30 2.22.32.42.52.62.72.82.9 IWA0038 1 2 Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 7 www.yageo.com Table 4 Max. and avg. antenna gain value of radiation pattern Plane XY (dBi) XZ(dBi) YZ (dBi) Vertical Pol. (max.) −8.9 −4.3 1.4 Vertical Pol. (avg.) −14.6 −9.8 −2.8 Horizontal Pol. (max.) 2.4 4.1 1.1 Horizontal Pol. (avg.) −3.7 −3.1 −5.2 Total gain (max.) 2.4 4.1 1.6 Total gain (avg.) −3.6 −2.8 −1.6 -10 −20 30 −4050 dBi −20−30−40−50 20304050 XYXZYZ dBi For antenna gain value see Table 4. Fig.6 Radiation pattern measurements Vertical Horizontal 0° −90°−270° −180° IWA0052 0° −270° −180° −180° 0° −90°−270°−90° − −-10 -10−−−− dBi XY plane YZ plane XZ plane − 270° −180° − 90° 0° 0° IWA0046 − 270° −180° − 90° 0° 0° − 270° −180° − 90° 0° 0° Fig.5 The definition of X-Y-Z plane and angle for radiation pattern Phycomp Product specification High Frequency SMD type antennas for BT/802.11b/g application 2.45 GHz size 7.8 × 3.6 2004 Jul 27 Rev.3 8 www.yageo.com 4 3 X X 1 1 5 0 0 2 4 5 Centre frequency Tolerance Size 7.8 x 3.6 x 0.9 mm15 Packing 11 13 reel: ∅180 mm; 7", blister, 1000 pcs bulk, 1000 pcs Material 1high-frequency material Family 43antenna IWA0040 2452.45 GHz Default 00 at 100 MHz Impedance Bandwidth 2252.25 GHz 02type 2302.30 GHz 03type 2602.60 GHz 06type 2702.70 GHz 07type Yageo part number EXAMPLE: CAN4311115002451K DESCRIPTION CODE Family CAN43 = antenna products Packing 11 = 180 mm/7” blister Materials 1 = high frequency materials Size 15 = 7.8 × 3.6 × 0.9 mm Tolerance 00 = large than 100 MHz Working Frequency (1) 245 = 2.45 GHz (Default) 220 = 2.25 GHz (02 type) 2…

Text truncated - open the document above for the full version.

Test Report

Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 1 of 41 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Product Name: Blood Glucose plus Blood Pressure Monitoring System Brand Name: N/A Model Name: TD-3260 Model Diffence: TD-326x(x=0~9) for difference customer FCC ID: TM7326000M00 Report No.: ER/2007/C0016 Issue Date: Feb. 25, 2008 FCC Rule Part: 15.249 Prepared for: Taidoc Technology Corp. 6F, No.127, Wugong 2nd Rd., Wugu Township, Taipei County, Taiwan Prepared by: SGS Taiwan Ltd. Electronics & Communication Laboratory No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei County, Taiwan. Note: This report shall not be reproduced except in full, without the written approval of SGS Taiwan Ltd. This document may be altered or revised by SGS Taiwan Ltd. personnel only, and shall be noted in the revision section of the document. Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 2 of 41 VERIFICATION OF COMPLIANCE Applicant: Taidoc Technology Corp. 6F, No.127, Wugong 2nd Rd., Wugu Township, Taipei County, Taiwan Product Description: Blood Glucose plus Blood Pressure Monitoring System Brand Name: N/A FCC ID Number: TM7326000M00 Model No.: TD-3260 Model Difference: TD-326x(x=0~9) for difference customer File Number: ER/2007/C0016 Date of test: Dec. 01, 2007 ~ Feb. 12, 2008 Date of EUT Received: Nov. 30, 2007 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. Electronics & Communication Laboratory The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4 (2003) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.249. The test results of this report relate only to the tested sample identified in this report. Test By: Date Feb. 25, 2008 Jason Wu/ Asst. Supervisor Prepared By: Date Feb. 25, 2008 Alex Hsieh/Sr. Engineer Approved By: Date Feb. 25, 2008 Vincent Su / Manager Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 3 of 41 Version Version No. Date 00 Feb. 25, 2008 01 Mar. 10, 2008 Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 4 of 41 Table of Contents 1. GENERAL INFORMATION ................................................................................................5 1.1 PRODUCT DESCRIPTION.........................................................................................................................5 1.2 RELATED SUBMITTAL(S) / GRANT (S) ....................................................................................................5 1.3 TEST METHODOLOGY.............................................................................................................................5 1.4 TEST FACILITY.......................................................................................................................................5 1.5 SPECIAL ACCESSORIES...........................................................................................................................5 1.6 EQUIPMENT MODIFICATIONS.................................................................................................................5 2. SYSTEM TEST CONFIGURATION ...................................................................................6 2.1 EUT CONFIGURATION............................................................................................................................6 2.2 EUT EXERCISE.......................................................................................................................................6 2.3 TEST PROCEDURE...................................................................................................................................6 2.4 LIMITATION............................................................................................................................................7 2.5 CONFIGURATION OF TESTED SYSTEM....................................................................................................9 3. SUMMARY OF TEST RESULTS ......................................................................................10 4. CONDUCTED EMISSIONS TEST ....................................................................................11 4.1 MEASUREMENT PROCEDURE: ..............................................................................................................11 4.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ......................................................................11 4.3 MEASUREMENT EQUIPMENT USED: .....................................................................................................12 4.4 MEASUREMENT RESULT: .....................................................................................................................12 5. RADIATED EMISSION TEST ...........................................................................................15 5.1 MEASUREMENT PROCEDURE...........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 29 of 39 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw APPENDIX 1 PHOTOGRAPHS OF SET UP Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 30 of 39 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Radiated Emission Setup Photos Report No.: ER/2007/C0016 FCC ID: TM7326000M00 Issue Date: Feb. 25, 2008 Page: 31 of 39 This document is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at www.sgs.com. Attention is drawn to the limitations of liability, indemnification, and Jurisdictional issued defined therein. Unless otherwise stated, the results shown in this test report refer only to the sample(s) tested. This document cannot be reproduced except in full, without prior approval of Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. , 列 www.sgs.com 說不 更 SGS Taiwan Ltd. No. 134, Wu Kung Rd., Wuku Industrial Zone, Taipei Country, Taiwan. / 北路134 t (886-2) 2299-3939 f (886-2) 2298-2698 www.sgs.com.tw Conducted Emission Set up Photos

Contact Information

Applicant

Jim Jan(Project Management Specialist)
[email protected]+886-2-66258188Fax: +886-2-66258810

Technical Contact

SGS Tainwan Ltd.Vincent Su
[email protected]

134, Wu Kung Rd., Wuku Industrial Zone · Taipei County · Taiwan

Test Firm

SGS TAIWAN LTD.NELSON BAI
[email protected]886-2-22993279Fax: 886-2-22999489

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from TAIDOC TECHNOLOGY CORP.

Blood Pressure Monitoring System - FCC ID TM73128B01 - TAIDOC TECHNOLOGY CORP.
TM73128B01

Blood Pressure Monitoring System

Jun 05, 2022

Equipment Class

DTS - Digital Transmission System
TD-9030A - FCC ID TM79030A01 - TAIDOC TECHNOLOGY CORP.
TM79030A01

TD-9030A

Jul 17, 2014

Equipment Class

DTS - Digital Transmission System
Handheld Pulse Oximeter - FCC ID TM78201BEM2 - TAIDOC TECHNOLOGY CORP.
TM78201BEM2

Handheld Pulse Oximeter

Jun 23, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Blood Glucose plus Blood Pressure Minitor - FCC ID TM73250CBEM2 - TAIDOC TECHNOLOGY CORP.
TM73250CBEM2

Blood Glucose plus Blood Pressure Minitor

Mar 11, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Blood Glucose Meter - FCC ID TM74111ABEM2 - TAIDOC TECHNOLOGY CORP.
TM74111ABEM2

Blood Glucose Meter

Jan 28, 2008

Equipment Class