FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Comark Limited/
  3. TVHRF500A

TVHRF500ARF500A Gateway

Comark Limited
RF500A Gateway - FCC ID TVHRF500A - Comark Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 08, 2011
Application Purpose
Original Equipment
Date of Application
May 08, 2011
Equipment Note
RF500A Gateway
Frequency Range
2404.19000000 - 2405.78000000
Company
Comark Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

β†—
β†—

Attestation Statements

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RF500A GATEWAY SYSTEM MANUAL Comark Wireless Monitoring - RF500A System Manual Contents RF500 System Components........................................................................................................................................................1 RF500A Gateway.....................................................................................................................................................................1 RF500 Transmitters.................................................................................................................................................................2 RF512 Temperature Transmitter.........................................................................................................................................2 RF512M Temperature Transmitter Backbone Option..........................................................................................................2 RF513 Temperature and Humidity Transmitter...................................................................................................................2 RF513M Temperature and Humidity Transmitter Backbone Option....................................................................................3 RF515 Analog Input Transmitter and RF515A Connection Box..........................................................................................3 RF515A Connection Box.....................................................................................................................................................3 RF516 Precision Temperature Transmitter..........................................................................................................................3 Optional Accessories...............................................................................................................................................................4 Know your Gateway.................................................................................................................................................................5 Front View with LEDs...........................................................................................................................................................5 Bottom Connections.............................................................................................................................................................7 Side Switches and Connections.........................................................................................................................................8 Know your Transmitter.............................................................................................................................................................9 Transmitter Display............................................................................................................................................................11 Safety Information......................................................................................................................................................................12 Warning..................................................................................................................................................................................12 WEEE....................................................................................................................................................................................13 RF500 Wireless Monitoring System Overview...........................................................................................................................14 Gateway – Introduction..........................................................................................................................................................14 Overview of RF500 Mesh Networking...................................................................................................................................16 Meshing Transmitters and Backbone Transmitters...............................................................................................................18 Automatic Data Retrieval (ADR)............................................................................................................................................18 Equipment Installation................................................................................................................................................................19 i Gateway Fixing......................................................................................................................................................................19 Transmitter Fixing..................................................................................................................................................................19 Mains Wiring..........................................................................................................................................................................19 Ventilation..............................................................................................................................................................................20 Powering On and Off.................................................................................................................................................................21 Switch On...............................................................................................................................................................................21 Gateway Switch OFF.............................................................................................................................................................22 Gateway Reset................................................................................................................................…

Text truncated - open the document above for the full version.

Attestation Statements

Telephone: 0844 (+44 844) 815 6599 Facsimile: 0844 (+44 844) 815 6598 Email: [email protected] – UK & Ireland [email protected] – International Internet: www.comarkltd.com Registered Office: Bury Mead Road Hitchin Hertfordshire SG5 1RT United Kingdom Registration No. 2929930 LETTER OF AGENCY 11 th April 2011 TRaC Global 100 Frobisher Business Park Leigh Sinton Road Malvern Worcestershire WR14 1BX UK To Whom It May Concern: We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application, is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Yours faithfully Comark Instruments David Goulden

Cover Letter(s)

Telephone: 0844 (+44 844) 815 6599 Facsimile: 0844 (+44 844) 815 6598 Email: [email protected] – UK & Ireland [email protected] – International Internet: www.comarkltd.com Registered Office: Bury Mead Road Hitchin Hertfordshire SG5 1RT United Kingdom Registration No. 2929930 REQUEST FOR CONFIDENTIALITY IN ACCORDANCE WITH FCC RULE 0.459 04 th April 2011 TRaC Global 100 Frobisher Business Park Leigh Sinton Road Malvern Worcestershire WR14 1BX UK RE: Certification Application FCC ID:TVHRF500A To Whom It May Concern: Please be advised that the following information is to be held confidential on behalf of Comark Instruments. Parts List Operational Description Schematics Block Diagram The application contains technical information which Comark Instruments deems to be trade secrets and propriety. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Yours faithfully Comark Instruments David Goulden

Test Report

Total number of pages : 50 TRaC Wireless Test Report : TTR-004771WUS1 Applicant : Comark Ltd. Apparatus : RF500A Specification(s) : CFR47 Part 15.247, July 2008 FCCID : TVHRF500A Purpose of Test : Certification Authorised by : : Radio Product Manager Issue Date :28 th April 2011 Authorised Copy Number : PDF Radio Test Report: TTR-004771WUS1 Contents Section 1: Introduction 3 1.1 General 3 1.2 Tests requested by 4 1.3 Manufacturer 4 1.4 Apparatus Assessed 4 1.5 Test Result Summary 5 1.6 Notes relating to the assessment 6 1.7 Deviations from Test Standards 6 Section 2: Measurement Uncertainty 7 2.1 Measurement Uncertainty Values 7 Section 3: Modifications 9 3.1 Modifications Performed During Assessment 9 Appendix A: Formal Emission Test Results 10 A1 6 dB Bandwidth 11 A2 Transmitter Peak Output Power 12 A3 Transmitter Power Spectral Density 13 A4 RF Antenna Conducted Spurious Emissions 14 A5 Radiated Electric Field Emissions within the Restricted Bands of 15.205 15 A6 Power Line Conducted Emissions 18 A7 Antenna Gain 20 A8 Unintentional Radiated Electric Field Emissions - 15.109 21 Appendix B: Supporting Graphical Data 24 Appendix C: Additional Test and Sample Details 39 Appendix D: Additional Information 45 Appendix E: Calculation of the duty cycle correction factor 46 Appendix F: Photograph s and Figures 47 2 Radio Test Report: TTR-004771WUS1 Section 1: Introduction 1.1 General This report contains an a ssessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on samples submitted to the Laboratory. Test performed at: TRaC [ ] Unit E South Orbital Trading Park Hedon Road Hull - HU9 1NJ United Kingdom Telephone: +44 (0) 1482 801801 Fax: +44 (0) 1482 801806 TRaC [X] Unit 1 Pendle Place Skelmersdale - WN8 9PN United Kingdom Telephone: +44 (0) 1695 556666 Fax: +44 (0) 1695 577077 Email: [email protected] Web site: http://www.tracglobal.com Tests performed by: D Winstanley Report author: D Winstanley This report must not be reproduced except in full without prior written permission from TRaC Telecoms & Radio. 3 Radio Test Report: TTR-004771WUS1 1.2 Tests requested by This testing in this report was requested by: Comark Ltd. Comark House Bury Mead Road Hitchin Herts SG5 1RT 1.3 Manufacturer As above. 1.4 Apparatus Assessed The followin g apparatus was assessed between 11 th and 14 th of April 2011: RF500A The above device is an RF Gateway Instrument operating in the 2400 – 2483.5 MHz band. The RF500A uses DSSS modulation and a single channel at 2405 MHz. 4 Radio Test Report: TTR-004771WUS1 1.5 Test Result Summary Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. The statements relating to compliance with the standards below apply ONLY as qualified in the notes and deviations stated in sections 1.6 to 1.7 of this test report. Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. Test Type Regulation Measurement standard Result Radiated spurious emissions (Restricted bands) Title 47 of the CFR: Part 15 Subpart C; 15.247 ANSI C63.10 Pass Conducted spurious emissions (Non-restricted bands) Title 47 of the CFR: Part 15 Subpart C; 15.247 ANSI C63.10 Pass AC Power conducted emissions Title 47 of the CFR: Part 15 Subpart C; 15.207 ANSI C63.10 Pass Occupied Bandwidth Title 47 of the CFR : Part 15 Subpart C; 15.247(a)(2) ANSI C63.10 Pass Conducted Carrier Power Title 47 of the CFR : Part 15 Subpart C; 15.247(b) ANSI C63.10 Pass Power Spectral Density Title 47 of the CFR : Part 15 Subpart C; 15.247(d) ANSI C63.10 Pass Unintentional Radiated Spurious Emissions Title 47 of the CFR: Part 15 Subpart B; 15.109 ANSI C63.10 Pass Digital Modulation Title 47 of the CFR: Part 15 Subpart C; 15.403 - N/A RF Safety Title 47 of the CFR : Part 15 Subpart C; 15.247(b)(5) - N/A Abbreviations used in the above table: Mod : Modification CFR : Code of Federal Regulations ANSI : American National Standards Institution REFE : Radiated Electric Field Emissions PLCE : Power Line Conducted Emissions 5 Radio Test Report: TTR-004771WUS1 1.6 Notes relating to the assessment With regard to this assessment, the following points should be noted: The results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 1.7 of this test report (Deviations from Test Standards). For emissions testing, throughout this test report, β€œPass” indicates that the results for the sample as tested were below the specified limit (refer also to Section 2, Measurement Uncertainty). Where relevant, the apparatus was only assessed using the monitoring methods and susceptibility criteria defined in this report. All testing with the exception of testing at the Open Area Test Site was performed under the following environmental conditions: Temperature : 17 to 23 ο‚°C Humidity : 45 to 75 % Barometric Pressure : 86 to 106 kPa All dates used in this report are in the format dd/mm/yy. This assessment has been performed in accordance with the requirements of ISO/IEC 17025. 1.7 Deviations from Test Standards There were no deviations from the standards test ed to. 6 Radio Test Report: TTR-004771WUS1 Section 2: Measurement Uncertainty 2.1 Measurement Uncertainty Values Radio Testing – General Uncertainty Schedule All statements of uncertainty are expanded standard uncertainty using a coverage factor of 1.96 to give a 95% confidence where no required test level exists. [1] Adjacent Channel Power Uncertainty in test result = 1.86dB [2] Carrier Power Uncertainty in test resul…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David French
[email protected]+448448155699Fax: +448448156598

Test Firm

Element Materials Technology Warwick LtdMax Leach
[email protected]4401482801801Fax: 44 (0) 1482 801 806

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.41 GHz5.90 mW
Confidentiality
Long Term
Grant Notes
Output Power is conducted, The equipment is to be used with an antenn of maximum gain 7dBi as detailed in the test report submitted with this filing.

Other Applications from Comark Limited

RF500LITE Gateway - FCC ID TVHRF500LITE - Comark Limited
TVHRF500LITE

RF500LITE Gateway

Mar 31, 2008

Equipment Class

DTS - Digital Transmission System