TXL-STI-ED55motion detection device that plays selectable sounds

Safety Technology International, Inc.
motion detection device that plays selectable sounds - FCC ID TXL-STI-ED55 - Safety Technology International, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 09, 2012
Application Purpose
Original Equipment
Date of Application
Sep 05, 2012
Equipment Note
motion detection device that plays selectable sounds
Frequency Range
2452.58000000 - 2452.58000000
Company
Safety Technology International, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix J: Manual Please see the following pages.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix A: FCC/TCB Agency Authorization Letter Please refer to the following page. iafety lechnology Intemational, Inc. 2306 Akport noid, W.terford, H {832t U.Sl. Fhoa€: ?tl8-673-9E98. SAI:118-673-1246. WGb: www.rtFu6..(ofl!. E-ffr{: lnfu@rtl-usr,ce{B Authoritv to Act as Aqent Date Mar 12, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, YA 22101 To Whom lt May Concern: Rhein Tech Laboratories, Inc. is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: Feb 28,2013 (Typically 8- 12 months) By: Title: On behalt of: Safetv Technoloqv International. lnc. Telephone: (Company Name) 248€73-9898 John Taylor (Print name) Executive Vice President

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix B: FCC Confidentiality Request Letter Please refer to the following page. 2306 ALrport Road Tel: (248) 673-9898 Waterford, Michigan Fax: (24a) 673-1246 48327 1209 Safety Technology International, Inc. July 19, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite Cl 10 Mclean, VA 22101 To Whom lt May Concern: The following information is to be held confidential pursuant to FCC 47 CFR S0 457(d) and $0.459, becJuse the information provided contains trade secrets and is proprietary. lf made iublic, the information might be used to the disadvantage ofthe applicant in the market place. o Schematics . Technical Product Description . Block Diagram Sincrrelfi (A^-cb"/z-<- y'5ot+t Tn,nlLoa u .?' www.sti-usa.com We protect the things that protect yau.

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix F: ID Label and Label Location Please refer to the following page. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. FCC ID: TXL-STI-ED55 IC: 6335A- STIED55 Model: ED-55

Internal Photos

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix M: Internal Photographs Please refer to the following pages. Front Wiring Wiring PCB Top PCB Bottom Microwave PCB

Test Report

Engineering Solutions & Electromagnetic Compatibility Services 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com FCC Part 15.249 & IC RSS-210 Certification Application Report Test Lab: Rhein Tech Laboratories, Inc. Tel: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 Web: www.rheintech.com Herndon, VA 20170 Email: [email protected] Applicant: Safety Technology International, Inc. 2306 Airport Road Waterford, MI 48327 Contact: John Taylor FCC ID IC TXL-STI-ED55 6335A-STIED55 Test Report Date August 30, 2012 Platform N/A RTL Work Order Number 2012241 Model ED-55 RTL Quote Number QRTL12-241A FCC Classification DXX – Part 15 Low Power Communication Device Transmitter FCC Rule Part(s) Part 15.249: Operation within the bands 902–928 MHz, 2400–2483.5 MHz, 5725–5875 MHz, and 24.0–24.25 GHz. (10-01-11) IC Standard RSS-210 Issue 8: Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment Procedure or Other Guidance ANSI C63.4-2003 Standard for Methods of Measurement of Radio-Noise Emissions Digital Interface Information N/A Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 2400-2483.5 N/A N/A 2M88F0N I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. Modifications made to the equipment during testing in order to achieve compliance with these standards are listed in the report. Furthermore, there was no deviation from, additions to, or exclusions from the applicable parts of FCC Part 2, FCC Part 15, IC RSS- 210 and ANSI C63.4. Signature: Date: August 30, 2012 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. and Safety Technology International, Inc. The test results reported relate only to the item tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Table of Contents 1 General Information .............................................................................................................................. 4 1.1 Scope ............................................................................................................................................ 4 1.2 Modifications ................................................................................................................................. 4 1.3 Test Facility ................................................................................................................................... 4 1.4 Related Submittal(s)/Grant(s) ....................................................................................................... 4 2 Test Information .................................................................................................................................... 5 2.1 Test Justification............................................................................................................................ 5 2.2 Exercising the EUT ....................................................................................................................... 5 2.3 Test Result Summary .................................................................................................................... 5 2.4 Test System Details ...................................................................................................................... 5 2.5 Configuration of Tested System .................................................................................................... 6 3 Duty Cycle Calculation - FCC 15.35(c) ................................................................................................. 7 4 Radiated Emissions – FCC 15.209, 15.249(a), RSS-210 A2.9 ............................................................ 8 4.1 Radiated Emission Limits Test Procedure .................................................................................... 8 4.2 Radiated Emission Limits Test Data ............................................................................................. 8 4.2.1 Radiated Fundamental Emissions Limits Test Data ................................................................. 8 5 Radiated Emission Limits Radiated Harmonics – FCC 15.249 ............................................................ 9 5.1 Radiated Emission Limits Test Procedure .................................................................................... 9 6 In -Band Emissions Requirement – FCC 15.215(c) ............................................................................. 11 6.1 Test Procedure ............................................................................................................................ 11 6.2 FCC 15.215(c) Requirement ....................................................................................................... 11 6.3 Test Data ..................................................................................................................................... 12 7 Occupied Bandwidth – RSS-Gen 4.6.1 .............................................................................................. 14 7.1 Modulated Bandwidth Test Procedure ........................................................................................ 14 8 Conducted Emissions ......................................................................................................................... 16 8.1 Site and Test Description ......................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Appendix K: Test Photographs Photograph 1: Radiated Emissions – Front View Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Photograph 2: Radiated Emissions – Side View Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Photograph 3: Conducted Emissions – Front View Rhein Tech Laboratories, Inc. Client: STI, Inc. 360 Herndon Parkway Model: ED-55 Suite 1400 Standards: FCC 15.249/IC RSS-210 Herndon, VA 20170 ID’s: TXL-STI-ED55/6335A-STIED55 http://www.rheintech.com Report #: 2012241 Photograph 4: Conducted Emissions – Rear View

Contact Information

Applicant

John F. Taylor(Executive Vice President)
[email protected]248-673-9898Fax: 248-673-1246

Technical Contact

Rhein Tech LabsRick McMurray
[email protected]7036890459

360 Herndon Parkway · Herndon · United States

Test Firm

Rhein Tech Laboratories, Inc.Richard McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.45 GHz - 2.45 GHz-
Confidentiality
Long Term

Other Applications from Safety Technology International, Inc.

Wireless Doorbell Extender - FCC ID TXL3331 - Safety Technology International, Inc.
TXL3331

Wireless Doorbell Extender

Jun 20, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Doorbell Chime Sensor - FCC ID TXL3301 - Safety Technology International, Inc.
TXL3301

Wireless Doorbell Chime Sensor

May 08, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Entry Alert Sensor - FCC ID TXL3551 - Safety Technology International, Inc.
TXL3551

Wireless Entry Alert Sensor

May 08, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Motion-Activated Sensor - FCC ID TXL3601 - Safety Technology International, Inc.
TXL3601

Wireless Motion-Activated Sensor

May 08, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Transmitter for use in a wireless alert system - FCC ID TXL34080 - Safety Technology International, Inc.
TXL34080

Transmitter for use in a wireless alert system

Jan 07, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter