
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Senao IAP2300M AX3000 Indoor Ceiling/Wall Mount AP QSG Mounting Method The access point can be mounted on the Ceiling and Wall. Please perform the following steps to install the device. Ceiling Mount 1. Screw the clips onto the bottom of the device. 2. Hook the clips onto T-Rail until you hear a click. Wall Mount 1. Determine where the Access Point will be placed and mark the location on the surface for two mounting holes. Use appropriate drill bit to drill two 8.1mm diagram and 26mm-deep holes on the marks. 2. Screw the Anchors into the holes until they are flush with the wall; screw the Screws into the Anchors but leave the screw head sticking out so you can hang the Access Point on it. 3. Hang the Access Point against the wall onto the Screw heads. (Anchors size: Φ 8.00mm x L 25mm / Screws size: Φ 5.00mm x L 16mm) Statement Senao Networks, Inc. AX3000 Indoor Ceiling/Wall Mount AP FCC ID: U2M-IAP2300M 1. USA—Federal Communications Commission (FCC) FCC COMPLIANCE STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. INFORMATION TO USER: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: ‐Reorient or relocate the receiving antenna ‐Increase the distance between the equipment and the receiver. ‐Connect the equipment to outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Country Code selection feature to be disabled for products marketed to the US. Operation of this device is restricted to indoor usage only.
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC regulations restrict the operation of this device to indoor use only
Senao Networks, Inc. 3F., No.529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan Date: 2024-06-19 FCC ID: U2M-IAP2300M To the attention of Federal Communications Commission Authorization and Evaluation Division Attestation Statements Attestation Statements Part 2.911(d)(5)(i) Filing Senao Networks, Inc. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization according to section 2.903 of the FCC rules. Attestation Statements Part 2.911(d)(5)(ii) Filing Senao Networks, Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely yours, ----------------------------------------------- Iris Chang/ Compliance Manager Telephone Number: +886-3-3289289 Ext:2620 Fax Number: +886-3-3961112 E-mail Address: [email protected]
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 2, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing Grantee Code: U2M Senao Networks, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, EnGenius Technologies Inc. is our designated U.S. agent for service of process for the above referenced Grantee Code. Senao Networks, Inc. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. EnGenius Technologies Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced Grantee Code. Designated U.S. Agent Information: Name: EnGenius Technologies Inc. FRN: 0021371836 Address: 1580 Scenic Avenue, Costa Mesa, California, United States, 92626 Contact Person: Meng Chee Leo Email: [email protected] Sincerely, Senao Networks, Inc. EnGenius Technologies Inc. Iris Chang Meng Chee Leo [Applicant signature] [U.S. Agent signature]
Senao Networks, Inc. 3F., No.529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan Date: 2024-06-198 FCC ID: U2M-IAP2300M We, Senao Networks, Inc. here declare that the device does not support channel 12 ~ 13 in 2.4GHz band and any non-US channels in all the operational mode(s) for the following product. If you should have any question(s) regarding this declaration, please don’t hesitate to contact us. Thank you! ----------------------------------- Iris Chang/ Compliance Manager Telephone Number: +886-3-3289289 Ext:2620 Fax Number: +886-3-3961112 E-mail Address: [email protected]
Senao Networks, Inc. 3F., No.529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan P O W E R O F A T T O R N E Y Date: 2022/04/25 FCC ID: U2M-IAP2300M To whom it may concern: We, the undersigned, hereby authorize Debby Lin of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to the FCC application for equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Debby Lin of BV CPS Taoyuan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to Contact us. Thank you! Sincerely yours, ------------------------------------------------------ Iris Chang/ Compliance Manager Telephone Number: +886-3-3289289 Ext:2620 Fax Number: +886-3-3961112 E-mail Address: [email protected]
Senao Networks, Inc. 3F., No.529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan Date: 2020/05/19 FCC ID: U2M-IAP2300M Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description Software Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ------------------------------------------------------ Iris Chang/ Compliance Manager Telephone Number: +886-3-3289289 Ext:2620 Fax Number: +886-3-3961112 E-mail Address: [email protected]
Reference No.: BDYS-WTW-P24030044_EXT Page 1/5 Brand: Senao, Model: IAP2300M Reference No.: BDYS-WTW-P24030044_EXT Page 2/5 Reference No.: BDYS-WTW-P24030044_EXT Page 3/5 Reference No.: BDYS-WTW-P24030044_EXT Page 4/5 Reference No.: BDYS-WTW-P24030044_EXT Page 5/5
Reference No.: BDYS-WTW-P24030044-1_EXT Page 1/11 Brand: NETGEAR, Model: WAX210 Reference No.: BDYS-WTW-P24030044-1_EXT Page 2/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 3/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 4/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 5/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 6/11 Adapter 1 (Brand: NETGEAR, Model: 2AAJ018FC) Reference No.: BDYS-WTW-P24030044-1_EXT Page 7/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 8/11 Adapter 2 (Brand: NETGEAR, Model: ADS-18FQC-12 12018E) Reference No.: BDYS-WTW-P24030044-1_EXT Page 9/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 10/11 Reference No.: BDYS-WTW-P24030044-1_EXT Page 11/11
Label & Label Location
Reference No.: BDYS-WTW-P24030044_INT Page 1/7 Brand: Senao, Model: IAP2300M Ant. 1 Ant. 2 Reference No.: BDYS-WTW-P24030044_INT Page 2/7 Reference No.: BDYS-WTW-P24030044_INT Page 3/7 Reference No.: BDYS-WTW-P24030044_INT Page 4/7 Reference No.: BDYS-WTW-P24030044_INT Page 5/7 Reference No.: BDYS-WTW-P24030044_INT Page 6/7 Reference No.: BDYS-WTW-P24030044_INT Page 7/7
Reference No.: BDYS-WTW-P24030044-1_INT Page 1/7 Brand: NETGEAR, Model: WAX210 Ant. 1 Ant. 2 Reference No.: BDYS-WTW-P24030044-1_INT Page 2/7 Reference No.: BDYS-WTW-P24030044-1_INT Page 3/7 Reference No.: BDYS-WTW-P24030044-1_INT Page 4/7 Reference No.: BDYS-WTW-P24030044-1_INT Page 5/7 Reference No.: BDYS-WTW-P24030044-1_INT Page 6/7 Reference No.: BDYS-WTW-P24030044-1_INT Page 7/7
Report No.: MFBDYS-WTW-P24030044 Page No. 1 / 9Report Format Version: 7.1.0 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1091) Report No.: MFBDYS-WTW-P24030044 FCC ID: U2M-IAP2300M Product: AX3000 Indoor Ceiling/Wall Mount AP, AX1800 Dual Band PoE WiFi 6 Access Point Brand: Senao, NETGEAR Model No.: IAP2300M, WAX210 Received Date: 2024/3/3 Test Date: 2024/4/1 Issued Date: 2024/6/19 Applicant: Senao Networks, Inc. Address: 3F., No. 529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kewi Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Desi gnation Number: 788550 / TW0003 Approved by: , Date:2024/6/19 Jeremy Lin / Project Engineer This test report consists of 9 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Pettie Chen / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBDYS-WTW-P24030044 Page No. 2 / 9Report Format Version: 7.1.0 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 3 Test Results ................................................................................................................................................................ 7 4 Conclusion .................................................................................................................................................................. 8 5 Information of the Testing Laboratories .................................................................................................................. 9 Report No.: MFBDYS-WTW-P24030044 Page No. 3 / 9Report Format Version: 7.1.0 Release Control Record Issue No. Description Date Issued MFBDYS-WTW-P24030044 Original release. 2024/6/19 Report No.: MFBDYS-WTW-P24030044 Page No. 4 / 9Report Format Version: 7.1.0 1 Certificate Product: AX3000 Indoor Ceiling/Wall Mount AP, AX1800 Dual Band PoE WiFi 6 Access Point Brand: Senao, NETGEAR Test Model: IAP2300M, WAX210 Sample Status: Engineering sample Applicant: Senao Networks, Inc. Test Date: 2024/4/1 FCC Rule Part: FCC Part 2 (Section 2.1091) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBDYS-WTW-P24030044 Page No. 5 / 9Report Format Version: 7.1.0 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatial-average SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit for occupational/controlled exposure is 20 W/kg, averaged over any 10 grams of tissue (defined as a tissue vol…
Text truncated - open the document above for the full version.
Address: No. 500&520, Fusing 3rd Rd., Hwa-Ya Technology Park Kuei-Shan Dist., Taoyuan City 33383, Taiwan IAP2300M AntennaDVT Test Report CustomerNetgear ProjectIAP2300M Project Description Dualband antenna *2 Date2024/06/18 Prepared byDaniel CheckedTony Report VersionA04 Executive Summary •Agenda –Antenna Development Resource –Antenna Testing Set Up –Placement and Specification –S11 & Isolation –RadiationPattern –Efficiency and Gain Antenna Development Resource 3D Anechoic Chamber - BWANT •Size: 7.32M(L)x3.66M(W)X3.66M(H) •Testing range from 400MHz to 7GHz •Chamber Isolation : 10KHz to 10GHz >100dB (NSA 94-106) •Calibration antenna : BWANT SD650 /SD740 /SD900 /SD1150 /SD1575 /SD1800 /SD2140 /SD2450 /SD3200 /SD3600 /SD4550 /SD5400 /HA-0508 •Calibration date: 2022/10/27 •Test software : BWANT 3D Passive 3D Anechoic Chamber DUT Setup DUT •The DUT is set up on the test fixture and the antenna is connected to the test cable to measure the antenna performance. X Z Y Test Degree ThetaPhi START 0 START 0 END 165 END 345 INCREMENT 15 INCREMENT 15 Placement and specification Ant No. Senao PN (VenderPN) Operating BandGain (dBi)Efficiency (%)Ant typeMaterial FeedingDimension Ant.1 7102A1229000 (98-019141-00) 2400MHz ~ 2500 MHz2.7~3.163~68 PIFAFR4Cable30*13*0.8mm 5150MHz ~ 5900 MHz3.4~4.263~68 Ant.2 7102A1230000 (98-019141-01) 2400MHz ~ 2500 MHz3.3~4.161~64 MonopoleFR4Cable29*13*0.8mm 5150MHz ~ 5900 MHz3.3~4.660~66 Ant.2 Ant.1 S-Parameter Freq. (MHz)S11S22S21 2400 -16.05 -10.80 -17.44 2450 -12.57 -12.75 -17.40 2500 -10.99 -14.54 -17.72 5150 -25.58 -16.83 -30.41 5550 -17.75 -25.55 -34.37 5850 -19.73 -15.43 -29.64 5900 -21.90 -15.96 -29.40 2D Radiation Pattern – Ant.1 @ 2GHz LED Ant.1 X Z Y LED LED LED 2D Radiation Pattern – Ant.1 @ 5GHz LED Ant.1 X Z Y LED LED LED 2D Radiation Pattern – Ant.2 @ 2GHz LED Ant.2 X Z Y LED LED LED 2D Radiation Pattern – Ant.2 @ 5GHz LED Ant.2 X Z Y LED LED LED Combine pattern – @ 2GHz LED Ant.2 Ant.1 X Z Y LED LED LED Combine pattern – @ 5GHz LED Ant.2 Ant.1 X Z Y LED LED LED Antenna Efficiency and Gain Antenna Performance Freq. (MHz) Ant.1Ant.2 Efficiency (%)Peak Gain (dBi)Efficiency (%)Peak Gain (dBi) 2400 632.7633.3 2450 683.1644.0 2500 673.0614.1 5150 674.0604.6 5500 633.4623.4 5850674.2663.3 5900684.1663.4
Address: No. 500&520, Fusing 3rd Rd., Hwa-Ya Technology Park Kuei-Shan Dist., Taoyuan City 33383, Taiwan WAX210 AntennaDVT Test Report CustomerNetgear ProjectWAX210 Project Description Dualband antenna *2 Date2024/06/18 Prepared byDaniel CheckedTony Report VersionA04 Executive Summary •Agenda –Antenna Development Resource –Antenna Testing Set Up –Placement and Specification –S11 & Isolation –RadiationPattern –Efficiency and Gain Antenna Development Resource 3D Anechoic Chamber - BWANT •Size: 7.32M(L)x3.66M(W)X3.66M(H) •Testing range from 400MHz to 7GHz •Chamber Isolation : 10KHz to 10GHz >100dB (NSA 94-106) •Calibration antenna : BWANT SD650 /SD740 /SD900 /SD1150 /SD1575 /SD1800 /SD2140 /SD2450 /SD3200 /SD3600 /SD4550 /SD5400 /HA-0508 •Calibration date: 2022/10/27 •Test software : BWANT 3D Passive 3D Anechoic Chamber DUT Setup DUT •The DUT is set up on the test fixture and the antenna is connected to the test cable to measure the antenna performance. X Z Y Test Degree ThetaPhi START 0 START 0 END 165 END 345 INCREMENT 15 INCREMENT 15 Placement and specification Ant No. Senao PN (VenderPN) Operating BandGain (dBi)Efficiency (%)Ant typeMaterial FeedingDimension Ant.1 7102A1229000 (98-019141-00) 2400MHz ~ 2500 MHz2.7~3.163~68 PIFAFR4Cable30*13*0.8mm 5150MHz ~ 5900 MHz3.4~4.263~68 Ant.2 7102A1230000 (98-019141-01) 2400MHz ~ 2500 MHz3.3~4.161~64 MonopoleFR4Cable29*13*0.8mm 5150MHz ~ 5900 MHz3.3~4.660~66 Ant.2 Ant.1 S-Parameter Freq. (MHz)S11S22S21 2400 -16.05 -10.80 -17.44 2450 -12.57 -12.75 -17.40 2500 -10.99 -14.54 -17.72 5150 -25.58 -16.83 -30.41 5550 -17.75 -25.55 -34.37 5850 -19.73 -15.43 -29.64 5900 -21.90 -15.96 -29.40 2D Radiation Pattern – Ant.1 @ 2GHz LED Ant.1 X Z Y LED LED LED 2D Radiation Pattern – Ant.1 @ 5GHz LED Ant.1 X Z Y LED LED LED 2D Radiation Pattern – Ant.2 @ 2GHz LED Ant.2 X Z Y LED LED LED 2D Radiation Pattern – Ant.2 @ 5GHz LED Ant.2 X Z Y LED LED LED Combine pattern – @ 2GHz LED Ant.2 Ant.1 X Z Y LED LED LED Combine pattern – @ 5GHz LED Ant.2 Ant.1 X Z Y LED LED LED Antenna Efficiency and Gain Antenna Performance Freq. (MHz) Ant.1Ant.2 Efficiency (%)Peak Gain (dBi)Efficiency (%)Peak Gain (dBi) 2400 632.7633.3 2450 683.1644.0 2500 673.0614.1 5150 674.0604.6 5500 633.4623.4 5850674.2663.3 5900684.1663.4
Report No.: RFBDYS-WTW-P24030044 Page No. 1 / 74Report Format Version: 7.1.0 TEST REPORT CERTIFICATE OF CONFORMITY Standard: 47 CFR FCC Part 15, Subpart C (Section 15.247) Report No.: RFBDYS-WTW-P24030044 FCC ID: U2M-IAP2300M Product: AX3000 Indoor Ceiling/Wall Mount AP, AX1800 Dual Band PoE WiFi 6 Access Point Brand: Senao, NETGEAR Model No.: IAP2300M, WAX210 (Refer to item 3.1 for more details) Received Date: 2024/3/3 Test Date: 2024/3/7 ~ 2024/5/28 Issued Date: 2024/6/19 Applicant: Senao Networks, Inc. Address: 3F., No. 529, Zhongzheng Rd., Xindian Dist., New Taipei City, Taiwan Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kewi Shan Dist., Taoyuan City 33383, Taiwan FCC Registration / Desi gnation Number: 788550 / TW0003 Approved by: , Date:2024/6/19 Jeremy Lin / Project Engineer This test report consists of 74 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Pettie Chen / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBDYS-WTW-P24030044 Page No. 2 / 74Report Format Version: 7.1.0 Table of Contents Release Control Record ....................................................................................................................................................... 4 1 Certificate .................................................................................................................................................................... 5 2 Summary of Test Results .......................................................................................................................................... 6 2.1 Measurement Uncertainty ........................................................................................................................................ 6 2.2 Supplementary Information ...................................................................................................................................... 6 3 General Information ................................................................................................................................................... 7 3.1 General Description .................................................................................................................................................. 7 3.2 Antenna Description of EUT ..................................................................................................................................... 8 3.3 Channel List .............................................................................................................................................................. 9 3.4 Test Mode Applicability and Tested Channel Detail ................................................................................................ 10 3.5 Duty Cycle of Test Signal........................................................................................................................................ 11 3.6 Test Program Used and Operation Descriptions .................................................................................................... 13 3.7 Connection Diagram of EUT and Peripheral Devices ............................................................................................ 13 3.8 Configuration of Peripheral Devices and Cable Connections ................................................................................ 14 4 Test Instruments ...................................................................................................................................................... 15 4.1 RF Output Power .................................................................................................................................................... 15 4.2 Power Spectral Density .......................................................................................................................................... 15 4.3 6 dB Bandwidth ...............................…
Text truncated - open the document above for the full version.
Reference No.: BDYS-WTW-P24030044_TSup Page 1/7 PHOTOGRAPHS OF THE TEST CONFIGURATION AC Power Conducted Emissions (Test Mode A) Reference No.: BDYS-WTW-P24030044_TSup Page 2/7 (Test Mode B) Reference No.: BDYS-WTW-P24030044_TSup Page 3/7 (Test Mode C) Reference No.: BDYS-WTW-P24030044_TSup Page 4/7 Unwanted Emissions below 1 GHz (Test Mode A) Reference No.: BDYS-WTW-P24030044_TSup Page 5/7 (Test Mode B) Reference No.: BDYS-WTW-P24030044_TSup Page 6/7 (Test Mode C) Reference No.: BDYS-WTW-P24030044_TSup Page 7/7 Unwanted Emissions above 1 GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 412.00 mW |

Ceiling Mount Access Point
Equipment Class
DTS - Digital Transmission SystemCloud Managed Wi-Fi 7 2x2 Wall-Plate Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WiFi 7 Tri-radio concurrent indoor ceiling mount AP, Cloud Lite 802.11be 2x3x3 Tri-Band Managed Indoor Wireless Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TXWiFi 7 Tri-radio concurrent indoor ceiling mount AP
Equipment Class
NII - Unlicensed National Information Infrastructure TXWireless Access Point
Equipment Class
DTS - Digital Transmission System