FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Datalogic S.r.l./
  3. U4F-PGSRF

U4F-PGSRFBarcode reader

Datalogic S.r.l.
Barcode reader - FCC ID U4F-PGSRF - Datalogic S.r.l.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Oct 13, 2024
Application Purpose
Original Equipment
Date of Application
Oct 10, 2024
Equipment Note
Barcode reader
Frequency Range
902.75000000 - 927.25000000
Company
Datalogic S.r.l.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Datalogic S.r.l. Via S. Vitalino, 13 40012 Calderara di Reno (BO) Italy Tel. +39 051 3147011 Fax +39 051 3147205 ©2024 Datalogic S.p.A. and/or its affiliates All rights reserved. Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval sys- tem, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates. Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Electronic versions of this document may be downloaded from the Datalogic website (www.datalogic.com). If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or conse- quential damages resulting from the use of this material. Datalogic reserves the right to change any specification at any time without prior notice. Trademarks Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. PowerScan is a trademark of Datalogic S.p.A. and/or its affiliates, registered in the U.S. All other trademarks and brands are property their respective owners. Patents See www.patents.datalogic.com for an updated patent list. PBT9600 RFID This product is covered by one or more of the following patents: Utility patents: EP1873886B1, EP2382502B1, EP2517148B1, EP2577559B1, EP2649555B1, EP2795534B1, EP3607487B1, US7948214, US8517273, US8743263, US8888003, US8915443, US9087251, US9430689, US9482793, US9569653, US9798948, US10025966, US10496858, US10817685, US10915719, US10915476, US11334735, ZL200780030808.2, ZL200880132595.9, ZL200980163411.X, ZL201080071124.9, ZL201180026461.0. Model Numbers: • PBT9600 Type SR RFUS • BC9600-BT • BC9620 REGULATORY INFORMATION All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the fol- lowing two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any change or modification to the product not expressly approved by Datalogic could void the user's authority to operate the device. FCC Class B Compliance Statement The user is cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal- lation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter- mined by turning the equipment off and on, the user is encouraged to try to cor- rect the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio or television technician for help. IC Canada Notice This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Base Charger BC9600-BT/BC9620 FCC To comply with FCC RF exposure compliance requirements, for mobile configura- tions, a separation distance of at least 20 cm must be mantained between the antenna of this device and all persons. IC Canada Notice A separation distance of at least 20 cm must be maintained between the antenna of this device and all persons to comply with the safety requirements for mobile RF exposure conditions in accordance with RSS-102 Issue 5. Une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil et toutes les personnes afin de respecter les exigences de sécurité relatives à l'exposition aux RF dans des conditions d'utilisation mobile, con- formément à la norme RSS-102 Ver…

Text truncated - open the document above for the full version.

Attestation Statements

Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. INTERNAL Datalogic Confidential U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: Datalogic USA, Inc. FRN: 0003789518 Contact person name: Ken Wyman Street address: 959 Terry Street ZIP/City/State Eugene, OR 97402 USA Telephone number: +1 541 302 4084 Email address: [email protected] Signature: Date: September 12, 2024 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Datalogic Grantee Code: U4F FRN Number 0016179699 Contact person name: Ruggero Cacioppo Street address: Via San Vitalino 13 ZIP/City/State/Country 40012 Lippo di Calderara di Reno (BO) – Italy Telephone number: +390513147393 Email address: [email protected] Signature: Date: September 12, 2024

Attestation Statements

Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. INTERNAL Datalogic Confidential Certification Application Attestation Statements Datalogic S.r.l. Via San Vitalino 13 40012 Lippo di Calderara di Reno (BO) - Italy Subject: FCC ID: U4F-PGSRF To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) Datalogic S.r.l. certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) Datalogic S.r.l. (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: September 12, 2024 City: Lippo di Calderara di Reno (BO) – Italy Name (2) : Ruggero Cacioppo Function: Product Quality Senior Manager Telephone number: +390513147393 Email address: [email protected] Signature: Revision Record Sheet: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK”

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. Declaration of Authorization We Name: Datalogic S.r.l. Address: Via San Vitalino, 13 City: 40012 Lippo di Calderara di Reno (BO) Country: Italy Declare that: Name Representative of agent: Luana Parisi (1) Agent Company name: PRSLAB S.r.l. Unipersonale Address: Via Campagna, 92 City: 22020 Faloppio (CO) Country Italy is authorized to apply for Certification of the following product(s): Product description: Barcode Reader Type designation: PBT9600 type SR RFUS Trademark: Datalogic Validity/ expiry date: March 31 st 2025 on our behalf. Date: September 12, 2024 City: Lippo di Calderara di Reno (BO) - Italy Name: Ruggero Cacioppo (2) Function: Product Quality Senior Manager Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure RF_501, Issue 11 Company Name: Datalogic S.r.l. Address: Via San Vitalino 13 City: Lippo di Calderara di Reno (BO) Country: Italy To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: U4F-PGSRF Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Date: September 12 th 2024 Name and signature of applicant: Ruggero Cacioppo Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. External Photos PBT9600 type SR RFUS Bottom view Rear Side Left side Right side Up side

ID Label/Location Info

Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. ID Label / Location info PBT9600 type SR RFUS Label ID Location

Internal Photos

Datalogic S.r.l. Società con socio unico | Gruppo Datalogic | Direzione e Coordinamento Datalogic S.p.A. Sede legale e amministrativa: via San Vitalino, 13 | 40012, Lippo di Calderara di Reno |Bologna | Italy Stabilimento: via Lavino 265 | 40050, Monte San Pietro | Bologna | Italy Tel. +39 051 3147011 | Fax. +39 051 3147288 | www.datalogic.com C.F. - P. IVA - Registro delle Imprese di Bologna 03217801202 R.E.A. Bologna 501477 | Capitale sociale 10.000.000,00 euro i.v. Internal Photos PBT9600 type SR RFUS Antenna RFID Module RFID module + antenna BT module

RF Exposure Info

1 (31) Copyright © Verkotan 2024 Document ID: FCC ISED_SAR report_PowerScan PBT9600 ID6821_08102024.docx SAR Compliance Test Report Date of Report: 8/10/2024 Client’s Contact person: Alberto Gamberini Number of pages: 31 Responsible Test engineer: Kalle Orava Testing laboratory: Verkotan Oy Elektroniikkatie 17 90590 Oulu Finland Client: DATALOGIC S.R.L. Via San Vitalino, 13 40012 Lippo di Calderara di Reno Italy Tested device: PBT9600 type SR RFUS Related reports: - Testing has been carried out in accordance with: 47CFR §2.1093 Radiofrequency Radiation Exposure Evaluation: Portable Devices FCC published RF exposure KDB procedures IEC/IEEE 62209-1528, 2020 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices RSS-102, Issue 6, 2023 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Documentation: The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory Test Results: The EUT complies with the requirements in respect of all parameters subject to the test. The test results relate only to devices specified in this document Date and signatures: 08.10.2024 Laboratory Manager 2 (31) Copyright © Verkotan 2024 Document ID: FCC ISED_SAR report_PowerScan PBT9600 ID6821_08102024.docx TABLE OF CONTENTS 1. SUMMARY OF SAR TEST REPORT ....................................................................................................................................................... 3 1.1 TEST DETAILS ..................................................................................................................................................................................................................... 3 1.2 MAXIMUM RESULTS ........................................................................................................................................................................................................ 4 1.2.1 Standalone SAR .......................................................................................................................................................................................................... 4 1.2.2 Simultaneous Transmission SAR ........................................................................................................................................................................ 5 1.2.3 Maximum Drift ............................................................................................................................................................................................................. 5 1.2.4 Measurement Uncertainty ...................................................................................................................................................................................... 5 2. DESCRIPTION OF THE DEVICE UNDER TEST (DUT) ........................................................................................................................... 6 2.1 SUPPORTED FREQUENCY BANDS AND OPERATIONAL MODES ...................................................................................................................... 6 2.2 TEST EXEMPTIONS ........................................................................................................................................................................................................... 7 2.2.1 FCC .................................................................................................................................................................................................................................. 7 2.2.2 ISED................................................................................................................................................................................................................................. 8 2.3 SIMULTANEOUS TRANSMISSION ............................................................................................................................................................................... 8 3. OUTPUT POWER .................................................................................................................................................................................... 9 3.1 MAXIMUM SPECIFIED CONDUCTED OUTPUT POWER ........................................................................................................................................ 9 3.2 TESTED CONDUCTED POWER ...................................................................................................................................................................................... 9 4. TEST EQUIPMENT ................................................................................................................................................................................ 10 4.1 TEST EQUIPMENT LIST ..................................................................................................................................................................................................11 4.1.1 Isotropic E-field Probe Type EX3DV4.................................................................................................................................................................12 4.2 PHANTOMS ......................................................................................................................................................................................................................12 4.3 TISSUE SIMULANTS .......................................................................................................................................................................................................12 4.4 SYSTEM VALIDATION STATUS ......................................................................…

Text truncated - open the document above for the full version.

Test Report

SF009794 01 DES NoDES RevChange No DATE DESCRIPTION DESIGNED BY APPROVED BY MATERIAL 1:24-05-2024 COLOR 1: SCALE UNIT DATALOGIC AND THE DATALOGIC LOGO ARE REGISTERED TRADEMARKS OF DATALOGIC S.P.A. IN MANY COUNTRIES, INCLUDING THE U.S.A. AND THE E.U., ALL THE TECHNICAL INFORMATION SHOWN ON THE DRAWING ARE INTELLECTUAL PROPERTY OF DATALOGIC S.P.A., ANY UNAUTHORIZED DISCLOSURE IS FORBIDDEN. DATALOGIC PROPRIETARY & CONFIDENTIAL INFORMATION MATERIAL 2: P.QuattriniCOLOR 2: 2:1 mm DESIGN CREATOR: A.Savarese CREATION DATE: MOLD N. PART N.PART REV. PGS-RFID ANTENNA + COAXIAL CABLE 740812000 A PEGASUS PAGE 1 OF 1 SHEET SIZE A3 TOLERANCES TABLE FOR SYMMETRICAL DIMENSIONS LIMITS OF PLASTIC PARTS ACCORDING TO ISO 20457 TOLERANCE GRADE >0 <=3 >3 <=6 >6 <=10 >10 <=18 >18 <=30 >30 <=50 >50 <=80 >80 <=120 >120 <=180 >180 <=250 >250 <=315 >315 <=400 >400 <=500 TG1-NW0,0120,0180,0220,0260,0310,0370,0440,055----- TG2-NW0,0190,0290,0350,0420,0500,0600,0900,1300,1500,1600,1800,2000,220 TG3-NW0,0300,0500,0600,0700,0800,1000,1500,2000,2300,2600,2900,3200,350 TG4-NW*0,0500,0800,0900,1100,1300,1500,2300,3200,3500,4100,4500,4900,550 TG5-NW0,0800,1100,1400,1700,200,2300,3600,5000,5800,6500,7000,7800,880 TG6-NW0,1200,1800,2200,2600,3100,3700,5700,8000,9301,0501,1501,2501,400 TG7-NW0,2000,2900,3500,4200,5000,6000,9001,2501,4501,6001,8002,0002,200 THE ABOVE TABLE IS BASED ON ISO 20457 FOR LINEAR DIMENSIONS. PLEASE REFER TO THE WHOLE ISO 20457 STANDARD FOR ALL DIMENSIONAL AND GEOMETRICAL TOLERANCES. NOT VALID FOR THERMOSET MOLDED RUBBER FOR WHICH REFER TO PRODUCTION PROCESS TABLE. 1 PART & DIMENSIONS 1.1 THIS PART WAS GENERATED FROM 3D CAD MODEL FILE: TC PN SF009794/01. 1.2 FOR GENERAL TOLERANCES REFER TO THE 3D MODEL THEORETICALLY EXACT DIMENSIONS, WITH A GLOBAL SURFACE TOLERANCE OF 0.5ABC ACCORDING TO ISO 22081, A,B AND C REPRESENT THE MAIN CONSTRUCTION REFERENCES OF THE PART. IF DATUMS A,B AND C ARE NOT SPECIFIED, USE BEST FIT ALIGNEMENT. 1.3 UNLESS OTHERWISE SPECIFIED USE TOLERANCES GROUP INDICATED IN TOLERANCES TABLE. GRADE SPECIFIED WITH * ACCORDING WITH ISO 20457 . 1.4 THE MODEL AND THE DRAWING MUST BE USED TOGETHER TO SATISFY MANUFACTURING REQUIREMENTS AS PER ISO 16792:2021-CLASSIFICATION CODE 3. IF THERE ARE CONFLICTS AMONG 3D AND 2D, THE 2D IS THE LEADING. 1.5 3D MODEL AND ALL DIMENSIONS ON THE DRAWING REPRESENT THE FINISHED PART, AFTER SURFACE TREATMENT (EX. TEXTURE) OR PAINTING. 1.6 DIMESIONS AND TOLLERANCES CONNECTED WITH Cpk-n SYMBOL ARE SIGNIFICANT; THEY SHALL BE CONSIDERED FUNDAMENTAL FOR PROCESS CONTROL AND "CONTROL PLAN" DEFINITION. THEIR VERIFICATION IS MANDATORY IN PPAP DOCUMENTATION: "Process Capability Analysis Report". 1.7 Cpk-n SYMBOL REQUIRES A Cpk VALUE OF 1,33."n" IS PROGRESSIVE NUMBER. DIFFERENT Cpk VALUES ARE DEFINED WITH Cpk-n x,xx SYMBOL. DEFAULT Cpk EXPECTED VALUE FOR ALL OTHER DIMENSIONS AND TOLLERANCES IS 1,00. 2 MATERIALS 2.1 REGULATORY CONTROLLED MATERIAL, NO SUBSTITUTIONS ALLOWED. 2.2 IF NOT OTHERWISE SPECIFIEED REGRIND MATERIAL IS NOT ALLOWED, PARTS SHALL BE MOLDED USING 100% VIRGIN MATERIAL. 2.3 MELT VOLUME RATE SHALL BE CARRIED OUT ACCORDING TO ISO 1133; AFTER MOLDING AN INCREASE OF 20% MAX. OF M.V.R. IS ALLOWED COMPARED TO VIRGIN MATERIAL GRAIN OF THE SAME BATCH, OR COMPARED TO THE INFORMATION OF THE CERTIFICATE OF THE SAME BATCH, WHEN AVAILABLE. 2.4 IF COLOR IS NOT A STANDARD FROM SUPPLIER, COLOR SHALL MEET VALUE IN THE "COLOR TABLE". MEASUREMENT SHALL BE TAKEN AT LOCATION P1-Pn. IF NOT SPECIFIED, MEASUREMENT SHALL BE TAKEN ON AT LEAST 10 RANDOM POINTS. FOR EACH POINT DE SHALL BE LESS THAN 2% COMPARED TO GOLDEN SAMPLES, REFERENCE COLOR PLATE OR COLOR COORDINATES. 2.5 MECHANICAL PROPERTIES MUST BE GUARANTEED ACCORDING TO DATALOGIC FALLING WEIGHT IMPACT STANDARD INCLUDED IN GM_SSM_004_SPP. 2.6 ALL EMPLOYED MATERIALS SHALL BE SELECTED AMONG RoHS COMPLIANT MATERIALS: THE EC DIRECTIVES TO BE REFERRED TO 2011/65/EU; THE EU REACH REGULATION EC 1907/2006, DATALOGIC POLICY ASKS FOR AVOID ANY SVHC IN PERCENTAGE GREATER THAN 1% W/W. 3 APPEARANCE 3.1 UNLESS OTHERWISE SPECIFIED SURFACE ROUGHNESS SHALL BE Ra 0,4. 3.2 PART SHALL CONFORM TO DATALOGIC STANDARD GM_SSM_004_SPP. 3.3 UNLESS OTHERWISE SPECIFIED SURFACES MUST BELONG TO CATEGORY "A" ACCORDING TO DATALOGIC STANDARD GM_SSM_004_SPP. 3.4 FINISHED PARTS SHALL BE CLEAN AND FREE DIRT, GREASE, AND OILS. 3.5 UNLESS OTHERWISE SPECIFIED ALL DEFECTS CAUSED BY THE PRODUCTIVE PROCESS SHALL BE ACCORDING TO GM_SSM_004_SPP. 4 PACKAGING 4.1 PACKAGE IN ACCORDANCE WITH DATALOGIC SUPPLIER PACKAGING STANDARD GM_SSM_002_SPP AND GM_SSM_007_SPI. ANY DAMAGE DURING SHIPMENT SHALL BE PREVENTED. 5 GENERAL REQUIREMENTS 5.1 NO MOLD RELEASE AGENTS ALLOWED. 5.2 THE PART SHALL BE MARKED WITH: RECYCLE SYMBOL IN AREA INDICATED (MRC) CAVITY NUMBER IN AREA INDICATED (MCV) DATE CODE IN AREA INDICATED (MDT) PART NUMBER IN AREA INDICATED (P/N) UNLESS OTHERWISE SPECIFIED, USE CHARACTERS HEIGHT 4 mm ON SURFACES OF CATEGORY "B", "C" AND "D" SURFACE, NO PRINTING IS ALLOWED ON CATEGORY "A" SURFACES. 6 GENERAL NOTES 6.1 CHANGES ARE INDICATED BY SYMBOL, WHICH INCLUDES THE PROGRESSIVE "DES Rev" NUMBER. 6.2 DRAWING NOTES SUPERSEDES DATALOGIC STANDARD IF THERE IS CONFLICT. 6.3 VERIFY LAST REVISION OF DL STANDARD AT THE FOLLOWING LINK: http://www.datalogic.com/terms_conditions PLEASE REFER TO THE FOLLOWING SPEC. ACCORDING TO PRODUCTION PROCESSALWAYS APPLICABLE ISO 20457 - PLASTIC MOULDED PARTS - TOLERANCESGM_SSM_002_SPP - SUPPLIER SHIPMENT ROUTING INS. ISO 10110 OPTHOMECHANICAL PARTSGM_SSM_007_SPI - SUPPLIER PACKAGING STD. ISO 10110-8 OPTOMECHANICAL PARTS SURFACE TEXTUREGM_SSM_004_SPP - PLASTIC & RUBBER STD. ISO 10579 - NON RIGID PARTSISO 22081 - GEOM.TOL. - GEN.GEOM.GEN.SIZE SPEC. ISO 3302-1 CLASS M1 AND ISO 3302-2 CLASS P - MOLDED RUBBER PARTSISO 1302 - SURFACE FINISHING ISO 1133 - PLASTICS - MFR & MVR DETERMINATIONISO 16792 - DIGITAL PROD. DEFIN. DATA PRACTICES ISO 10135 - DESIGN STD. FOR MOLDED, CAST AND FORGED PARTSISO 13715 - EDGES OF UNDEFINED SHAPE ADDITIONAL NOTES 1 A 1 A 2 B …

Text truncated - open the document above for the full version.

Test Report

PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev06 Test Report FCCTR Test report n. FCCTR_185482-0 I Date 25/09/2024 Page 1 di 47 TEST REPORT Ref. n. FCCTR_185482-0 Issue Date: 25/09/2024 Pages: 47 Test object Type test according to Standards 47 CFR FCC part 15.247 Applicant DATALOGIC S.r.l. Via S. Vitalino 13 - 40012 Lippo Di Calderara Di Reno - Bologna - Italy Phone. +39 051 3147196 Fax +39 051 3147561 Trade mark Manufacturer DATALOGIC S.r.l. Product Barcode reader Tested model PBT9600 Type SR RFUS FCC Identification number U4F-PGSRF Date of test samples receipt 28/08/2024 No. of tested samples 1 – Sampled by the manufacturer Test date From 02/09/2024 to 23/09/2024 Testing site PRSLAB S.r.l. Unipersonale - Via Campagna 92 - 22020 Faloppio - Como - Italy FCC designation number IT0012 Test results COMPLIANT Verifications carried out by Edoardo AMATI EMC and RADIO Test Engineer Approved by Daniele AOSANI Reviewer The test results reported in this test report shall refer only to the samples tested. The sample has been provided by the customer and the results apply to the sample as received. This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory. PRS refuses any responsibility about information provided by the customer contained in this test report. PRS LAB S.r.l. Unipersonale Sede operativa e Laboratori di prova - Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it Mod 18_48 rev06 Test Report FCCTR Test report n. FCCTR_185482-0 I Date 25/09/2024 Page 2 di 47 TABLE OF CONTENTS 0. RELEASE CONTROL RECORD ..................................................................................................... 3 1. DECISION RULE ........................................................................................................................ 3 2. INFORMATION PROVIDED BY CUSTOMER ................................................................................. 3 3. GENERAL REMARKS ................................................................................................................. 3 4. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ................................................. 4 4.1 EUT Identification ......................................................................................................................... 4 4.2 RFID module technical data ..…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ruggero Cacioppo(Product Quality Leader)
[email protected]+39 051 3147Fax: +39 051 3147 288

Technical Contact

Datalogic S.r.l.Alberto Gamberini
[email protected]390513147562

Via San Vitalino 13 · Italy

Test Firm

PRS LAB S.r.l.Riccardo Pfeiffer
[email protected]+39 031 3500011Fax: +39 031 991309

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 927.25 MHz100.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 0mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for stand-alone and simultaneous transmission exposure conditions are 0.4 W/kg and 0.64 W/kg, respectively.

Other Applications from Datalogic S.r.l.

Wireless charger base station - FCC ID U4F-WLC4600 - Datalogic S.r.l.
U4F-WLC4600

Wireless charger base station

Dec 17, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charger Base Unit - FCC ID U4FBC9620WRLCHR - Datalogic S.r.l.
U4FBC9620WRLCHR

Wireless Charger Base Unit

Dec 19, 2023

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Charger Base Unit - FCC ID U4FWRLCHRP - Datalogic S.r.l.
U4FWRLCHRP

Wireless Charger Base Unit

Dec 03, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
915MHz radio module - FCC ID U4F0022 - Datalogic S.r.l.
U4F0022

915MHz radio module

Feb 16, 2014

Equipment Class

DTS - Digital Transmission System
Star Module PLUS Small 910MHz - FCC ID U4F0021 - Datalogic S.r.l.
U4F0021

Star Module PLUS Small 910MHz

Jan 11, 2011

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified