Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 4 | 90,95A | 406.125 MHz - 469.9875 MHz | 2 W | 10K0F3E | 2
ppm |
Grant NotesMaximum conducted output power is 4.4W according to 90.205(s).
This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip tested for this filing. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Head: 4.79W/kg for 50% Duty Cycle; Body: 7.04W/kg for 50% Duty Cycle.