Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 6 | 24E | 1.85 GHz - 1.91 GHz | 197.00 mW | 4M20F9W | 2.5
ppm |
Grant NotesOutput power listed is conducted; the maximum ERP measured is 0.87 watt for GSM850 band and the maximum EIRP measured is 1.16 watt for PCS1900 band described in this filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for filings under this FCC ID. For satisfying FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 2.0 cm separation between the device, including its antenna, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for this filing under this FCC ID are: Part 22H-Head: 0.795 W/kg, Body: 0.198 W/kg; Part 24E-Head: 0.992 W/kg, Body 0.279 W/kg.
This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. This device does not contain Personal/Portable Hot-Spot functionality.