FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Goldlok Holdings (Guangdong) Co., Ltd./
  3. UFR230723082309

UFR230723082309Radio Control Thunder Charger

Goldlok Holdings (Guangdong) Co., Ltd.
Radio Control Thunder Charger - FCC ID UFR230723082309 - Goldlok Holdings (Guangdong) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 01, 2010
Application Purpose
Original Equipment
Date of Application
Jun 01, 2010
Equipment Note
Radio Control Thunder Charger
Frequency Range
27.14500000 - 27.14500000
Company
Goldlok Holdings (Guangdong) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

OPEN OFF ON OFF ON Install "AA"/LR6 batteries into each unit that requires batteries: A total of 8 batteries are needed. Insérez des piles "AA"/LR6 dans chaque appareil qui fonctionne sur piles: Au total 8 piles sont nécessaires. Ponga pilas "AA"/LR6 en cada aparato que las requiera: Se necesita un total de 8 pilas. Instala as pilhas "AA"/LR6 em cada uma das unidades que requerem pilhas: São necessárias 8 pilhas no total. Montare le batterie "AA"/LR6 in ogni unità che necessita di batterie: In totale, sono necessarie 8 batterie. Plaats de vereiste "AA"/LR6 batterijen in elke eenheid: In totaal zijn er 8 batterijen nodig. Legen sie in jedes fach, in das batterien gehören, "AA"/LR6 batterien: Insgesamt werden 8 batterien benötigt. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Item No. 2308A Description: RADIO CONTROL THUNDER CHARGER 2308A One pair MADE IN CHINA • FABRIQUÉ EN CHINE • FABRICADO EN CHINA • HERGESTELLT IN CHINA• FABRICADO NA CHINA • FABBRICATO IN CINA • GEFABRICEERD IN CHINA

Block Diagram

Left key Right key Back key TT10s Encoder Q1 Mixer Battery Q2 RF Amplifier Forward key ANT 455 KHz Oscillator 27.145 MHz Oscillator

External Photos

INTERTEK TESTING SERVICE Report No.: HK10040785-1 Equipment Photographs Model : 2308-A (External) FCC ID: UFR230723082309

Internal Photos

INTERTEK TESTING SERVICE Report No.: HK10040785-1 Equipment Photographs Model : 2308-A (Internal) FCC ID: UFR230723082309 INTERTEK TESTING SERVICE Report No.: HK10040785-1 Equipment Photographs Model : 2308-A (Internal) FCC ID: UFR230723082309

Operational Description

FCC ID: UFR230723082309 Technical Description: The brief circuit description is listed as follows : - L, R, B, F are Control Key - TT10S and associated circuit act as Encoder and MCU - TX1 act as Oscillator - Q1 and associated circuit act as Mixer - Q2 and associated circuit act as RF Amplifier Antenna Used : Telescope-type antenna with unique antenna connector.

Schematics

1 2 3 4 ABCD 4 3 2 1 D CBA Title Number Revision Size A4 Date: 20-May-2010 Sheet of File: E:\wt\new production\2308-21-EX\2308-21\GL011T 2308-21 (原原原) .DDB Drawn By: L 2308-21 TX R R11K LED1 C3 104 C11 100UF C1 104 B F R247K R4 10K Q1 1815 TX1 27.145MHz L1 5.6UH C7 471 C10 18PF C6 103 Q2 8050 F1065 C11A 100UF C8 510PF C2 104 L2 5.6UH C9 121 L3 6.8uH BT3V ANT U1 TT10S R3 100R TX2 455KHE C4 20P C5 20P SO/CO A1 161514131211109 87654 NC 3 R 2 A0 1 G NC F L B NC T OSCI VDD OSCO PC

Test Report

INTERTEK TESTING SERVICES Report No.: HK10040785--1 Sample No.: 4/4 (Mod) Code: FCC15C_c / Effective Date: 04 Aug 2009 ( of ) Bandwidth Plot – Pursuant to FCC Part 15 Section 15. 227 Requirement (Pass/Fail)

Test Report

- The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Report No.: HK10040785-1 Goldlok Toys Holdings (Guangdong) Co., Ltd. Application For Certification (FCC ID: UFR230723082309) Transmitter Prepared and Checked by: Approved by: Signed On File Lau Chin Yu, Benny Engineer Chan Chi Hung, Terry Senior Lead Engineer Date: May 28, 2010 INTERTEK TESTING SERVICES Report No.: HK10040785-1 FCC ID: UFR230723082309 i GENERAL INFORMATION Goldlok Toys Holdings (Guangdong) Co., Ltd. MODEL: 2308-A FCC ID: UFR230723082309 Grantee: Goldlok Toys Holdings (Guangdong) Co., Ltd. Grantee Address: Room 701-706, 7/F., Tower B, New Mandarin Plaza, 14 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong. Contact Person: Ms Sandy Mui Tel: 23121577 Fax: 23120490 e-mail: [email protected] Manufacturer: Goldlok Toys Holdings (Guangdong) Co., Ltd. Manufacturer Address: N/A Brand Name: N/A Model: 2308-A Additional Model: 2308-01, 2308-02, 2308-03, 2308-04, 2308-05, 2308-06, 2308-07, 2308-08, 2308-09, 2308-10, 2308-11, 2308-12, 2308-13, 2308-14, 2308-15, 2308-16, 2308-17, 2308-18, 2308-19, 2308-20, 2308-20GF, 2308-21, 2308-22, 2308- 23, 2308-24, 2308-25, 2308-26, 2308-27, 2308-28, 2308- 51, 2308-52, 2308-53, 2308-54, 2308-55, 2308-56, 2308- 57, 2308-58, 2308-59, 2308-60, 2309-01, 2309-02, 2309- 03, 2309-04, 2309-05, 2309-06, 2309-07, 2309-08, 2309- 21, 2309-22, 2309-23, 2309-24, 2309-25, 2309-26, 2309- 51, 2309-52, 2309-53, 2309-54, 2309-55, 2309-56, 2307- 01, 2307-02, 2307-03, 2307-04, 2307-05, 2307-06, 2307- 07, 2307-08, 2307-21, 2307-22, 2307-23, 2307-24, 2307- 25, 2307-26, 2307-51, 2307-52, 2307-53, 2307-54, 2307- 55, 2307-56, 2311-01, 2311-02, 2311-03, 2311-04, 2311- 05, 2311-06, 2311-07, 2311-08, 2311-09, 2311-10, 2311- 51, 2311-52A, 2311-52B, 2311-52C, 2311-52D, 2311- 52E, 2311-52F, 2311-52G, 2311-52H, 2311-52I, 2311- 52J, 2311-52K, 2311-52L, 2311-52M, 2311-52N, 2311- 52O, 2311-52P, 2311-52Q, 2311-52R, 2311-52S, 2311- 52T, 2311-52U, 2311-52V, 2311-52W, 2311-52X, 2311- 52Y, 2311-52Z, 2311-53, 2311-54, 2311-55, 2311-56, 2311-91, 2311-92, 2311-93, 2311-94, 2311-95, 2311-96, 2311-97, 2311-98, 2311-99 Asst. No.: 2308, 2308-21-A, 2308-51-A, 2307, 2307-A, 2307-21-A, 2307-51-A, 2309, 2309-A, 2309-21-A, 2309-51-A, 2311, 2311-A, 2311-52, 2311-52-A Type of EUT: Transmitter Description of EUT: Radio Control Thunder Charger (Radio Control Racing Car), (Radio Control Car) Serial Number: N/A FCC ID: UFR230723082309 Date of Sample Submitted: April 16, 2010 Date of Test: April 23, 2010 Report No.: HK10040785-1 Report Date: May 28, 2010 Environmental Conidtions: Temperature: +10 to 40°C Humidity: 10 to 90% INTERTEK TESTING SERVICES Report No.: HK10040785-1 FCC ID: UFR230723082309 ii SUMMARY OF TEST RESULT Goldlok Toys Holdings (Guangdong) Co., Ltd. MODEL: 2308-A FCC ID: UFR230723082309 TEST SPECIFICATION REFERENCE RESULTS Maximum Peak Output Power 15.247(b), (c) / RSS-210 A8.4 N/A Hopping Channel Carrier Frequencies Separation (for 2.4GHz Digital) 15.247(e) / RSS-210 A8.1 N/A 20dB Bandwidth of the Hopping Channel 15.247(a) / RSS-210 A8.1 N/A Number of Hopping Frequencies 15.247(e) / RSS-210 A8.1 N/A Average Time of Occupancy of Hopping Frequency 15.247(e) / RSS-210 A8.1 N/A Anteann Conducted Spurious Emissions 15.247(d) / RSS-210 A8.5 N/A Radiated Spurious Emissions 15.247(d) / RSS-210 A8.5 N/A RF Exposure Compliance 15.247(i) / RSS-Gen 5.5 N/A Transmitter Power Line Conducted Emissions 15.207 / RSS-Gen 7.2.2 N/A Transmitter Field Strength (for 27MHz) 15.227 / RSS-310 3.8 Pass Transmitter Field Strength (for 40MHz) 15.229 / RSS-210 A2.7 N/A Transmitter Field Strength, Bandwidth and Timing Requirement (for Remote Control) 15.231(a) / RSS-210 A1.1.1 N/A Transmitter Field Strength, Bandwidth and Timing Requirement (for 433MHz) 15.231(e) / RSS-210 A1.1.5 N/A Transmitter Field Strength and Bandwidth Requirement(for 88-108MHz) 15.239 / RSS-210 A2.8 N/A Transmitter Field Strength and Bandwidth Requirement(for 902- 928MHz or 2.4GHz) 15.249 / RSS-210 A2.9 N/A Transmitter Field Strength and Bandwidth Requirement (for 49MHz) 15.235 / RSS-310 3.9 N/A Receiver / Digital Device Radiated Eissions 15.109 / ICES-003 N/A Digital Device Conducted Emissions 15.107 / ICES-003 N/A Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is considered sufficient to comply with the pervisions of this section. 2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained within the frequency band designated (mentioned as above) which the EUT operated. The effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and frequency stability over excepted variations in temperature and supply voltage were considered. INTERTEK TESTING SERVICES Report No.: HK10040785-1 FCC ID: UFR230723082309 iii Ta…

Text truncated - open the document above for the full version.

Test Setup Photos

INTERTEK TESTING SERVICE Report No: HK10040785-1 FCC ID: UFR230723082309 Configuration Photographs Worst-Case Radiated Emissions (Front View) Model : 2308-A Figure 1 INTERTEK TESTING SERVICE Report No: HK10040785-1 FCC ID: UFR230723082309 Configuration Photographs Worst-Case Radiated Emissions (Back View) Model : 2308-A Figure 2

Contact Information

Applicant

Michael Yeung(Director)
[email protected](852) 2312-1577Fax: (852) 2312-0490

Technical Contact

Intertek Testing Services Hong Kong LtdBen Ho
[email protected]852-21738505

2/F Garment Centre · Kowloon · Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong LtdBen Ho
[email protected]852-21738505

Test Firm

Intertek Testing Services Hong Kong Ltd.Billy Chow
[email protected]85221738528Fax: 85227410521

Technical Specifications

#Rule PartsFrequency RangePower Output
115C27.145 MHz - 27.145 MHz-

Other Applications from Goldlok Holdings (Guangdong) Co., Ltd.

Radio Control Construction (Radio Control Dump Truck) - FCC ID UFR2350070809 - Goldlok Holdings (Guangdong) Co., Ltd.
UFR2350070809

Radio Control Construction (Radio Control Dump Truck)

Jun 13, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Full Function Radio Control Simulate Driver - FCC ID UFR2306 - Goldlok Holdings (Guangdong) Co., Ltd.
UFR2306

Full Function Radio Control Simulate Driver

May 05, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter