User Guide © 2007 FlipStart Labs. All rights reserved. Reproduction of any part of this manual without the prior written permission of Vulcan Portals Inc. is strictly prohibited. Information in this document is subject to change without notice. Screen images simulated. Actual product may differ. FlipStart, the FlipStart logo, InfoPane, FlipStart Navigator, FlipStart Zoom, and FlipStart Control Center are trademarks of Vulcan Portals Inc. Microsoft, Windows, Vista and Outlook are trademarks of Microsoft Corporation. The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Vulcan Portals Inc. is under license. Other trademarks and trade names in this document refer to the entities claiming the marks and names or their products. FlipStart Labs disclaims any proprietary interest in trademarks and trade names other than its own. The FlipStart ® device, accessories bearing the FlipStart logo and FlipStart proprietary software are protected by copyright, international treaties and patents, including the following U.S. patents: 6,839,231 and 6,977,811. Additional patents are registered or pending in countries around the world. Part no. 600-0118-01 i Contents Introduction 1 Typographical conventions and icons used in this manual ........................................................... 2 Safety precautions .............................................................................................................................................. 3 General precautions ............................................................................................................................... 3 AC adapter.................................................................................................................................................. 4 Batteries ....................................................................................................................................................... 4 Airplane travel and hospitals ............................................................................................................. 4 Using FlipStart Help Central ........................................................................................................................... 5 Getting help from FlipStart ............................................................................................................................. 6 Getting to know your FlipStart 7 Welcome to FlipStart! ....................................................................................................................................... 7 The productivity of a PC ...................................................................................................................... 7 Familiar form factor ............................................................................................................................... 7 Easy access ................................................................................................................................................ 7 Straightforward connectivity ............................................................................................................ 7 What's in the box? ............................................................................................................................................... 9 Front view with display open ...................................................................................................................... 10 Top view with display closed ....................................................................................................................... 12 Right side view ..................................................................................................................................................... 13 Back view ............................................................................................................................................................... 14 Setting up 15 Quick Start ............................................................................................................................................................ 16 Turning the FlipStart on for the first time .............................................................................................. 17 Charging the battery before using unplugged .......................................................................18 How to hold the FlipStart .............................................................................................................................. 19 Using input devices .......................................................................................................................................... 20 Using the keyboard ............................................................................................................................. 20 Using the mouse controls ................................................................................................................ 23 Direction pad (D-pad) ....................................................................................................................... 23 Zoom key .................................................................................................................................................. 24 Using the Jog Dial ................................................................................................................................ 24 Getting connected to the Internet ........................................................................................................... 26 Connecting for the first time .......................................................................................................... 26 Configuring Wi-Fi (802.11b/g) wireless networking ........................................................... 26 Configuring cellular wireless broadband networking .........…
Text truncated - open the document above for the full version.
Non-Conformities FCC ID: UIQE1500 (CKC CS Ref # E0 7-000118-FCC-01) The items listed below represent requests for infor mation following review of this application for cer tification under United States (FCC) regulations. Further question may arise pending review of responses to t hese items. OK # Non-Conformity or Comment Submitted Response Respondent / Date of Response * FCC Notes: HSPA Release 5 (see operational descr iption) x 1 For the RF exposure report: TCB understands WWA N and WiFI / BT do not have simultaneous cotransmission. However, does th e WiFI and BT have simultaneous cotransmission? If so, was SAR evalua ted in the operational configuration? 12/13/07 comments: Regarding your response to item 1; the SAR testing report does not mention cotransmission. It appears that the SAR test report treats the WWAN and the WiFi and BT devices separat ely. Please keep in mind that the TCB is not allowed to review SAR repo rts where RF output power of the secondary device exceeds a certain lim it, if the device is capable of simultaneous cotransmission of the WiFi and WWAN radios RF exposure may require to be addressed and the application wil l require FCC intervention which will cause an additional delay for final cert ification. Please clarify whether the equipment operates with simultaneous co transmission of the WiFi and BT modules. SAR was evaluated for WiFi and BT simultaneous cotransmission. From: Erik Fierce [mailto:[email protected]] Sent: Friday, December 14, 2007 1:11 PM To: Report Department Subject: RE: Vulcan WO 86709 Model E-1501 Series It does not operate with simultaneous cotransmission of the WWAN and WiFi CKC Labs 12/13/07 X 2 On the Block diagram of the Carlo PCB, please i dentify the frequencies used in each block as required by 2.1033(b)(5). Please use the information from the previous submittal E07-000020. CKC Labs 12/13/07 X 3 The temporary confidentiality request does not include a proper reference to DA04-1705 (there appears to have been a typo omitti ng the “5”). Additionally, this request is not legitimate. The references to RF Exposure report, test report and ID Label exhibits are not e ligible for short term confidentiality. Please also note that your reques t identifies a date which has already expired. Please revise your request and/or provided documentation accordingly. Please delete the request for temporary confidentiality. CKC Labs 12/13/07 X 4 Please provide proper emissions designators as required by form 731 for the PCB application information. Please use the emissions designators from the uploaded TCB grant. CKC Labs 12/13/07 X 5 Please provide proper frequency tolerance as re quired by form 731 for the PCB application information. Please use the frequency tolerance from the uploaded TCB grant. CKC Labs 12/13/07 X 6 The frequency range listing provided include th e whole band of operation, Please use the frequency range from the CKC Labs 12/13/07 please provide the frequency range from center freq uency of the lowest channel to the center frequency of the highest oper ating channel. uploaded TCB grant. X 7 This equipment additionally has a WiFi and BT c omponents included, however no operational details have been given supp orting operation of this equipment. Please provide operational details for inclusion in form 731. Please note, CKC CS has on file the original applic ation documentation. If some of this documentation may be used, please indi cate which files continue to be applicable to this equipment (eg, CKC CS cann ot assume that the files for the WiFi and BT filings are applicable without express direction from the client.) Please use the information from the previous submittal E07-000020. CKC Labs 12/13/07 X 8 Power output measurements: in the test report o n pages 9, 11-15, and 22-23 the WCDMA measurements are performed with a RBW of 3MHz. Please explain how this measurement technique properly acc ounts for the channel power measured since the occupied bandwidth of the signal is 4.5 MHz. A revised test report has been uploaded. CKC Labs 12/13/07 X 9 The internal and external photos of the equipme nt provided do not appear to fulfill the requirements of 2.1033, please provide photos as required or in conjunction with item 7 above. Additional photos have been uploaded. CKC Labs 12/1 3/07
External Photos Flipstart Top Flipstart Top - with port replicator Flipstart Bottom, Battery on Flipstart Bottom, Battery removed Flipstart Bottom - with port replicator Flipstart Front Flipstart Back - with port replicator Flipstart Back - no port replicator Flipstart Left side Flipstart Left side - with port replicator Flipstart Right side Flipstart Right side - with port replicator Flipstart Open - inside Flipstart Open, outside - with battery Flipstart Open, outside - without battery Flipstart Battery label sample
Open outside with battery Open outside without battery Open inside Battery label sample WAN antenna placement in lid Rear WiFi and BT antenna and shield WiFi diversity antenna in front of unit WiFi diversity antenna shield Diversity antenna on front of motherboard Carlo board top Carlo bottom with RF shields on Carlo bottom under RF shields Carlo board removed from motherboard Dino top overview with WAN module Note: This is an example of placement of the module, not the actual module used in this product. The actual module used is MC5725. Dino top WAN module and LCD removed Dino top under RF shield Dino top left side Dino bottom center Dino bottom left side Dino bottom right side
WWAN Antenna Location Overview WWAN Module Location Overview WWAN Module Socket and Underside
Internal Photos Flipstart rear WiFi and BT antenna and shield WiFi diversity antenna shield WiFi diversity antenna in front of unit Dino top - under RF shield Dino board top - WAN module and LCD removed Diversity antenna on front of motherboard Carlo board removed from motherboard Carlo board top Carlo board bottom - RF shields on Carlo Bottom - under RF shields
© 2007 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 2867 Progress Place, Suite 4D • Escondido, CA 92029 • U.S.A. TEL (760) 737-3131 • FAX (760) 737-9131 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Vulcan Portals Inc. Dates of Test: August 24-31, 2007 505 Fifth Ave. S Test Report Number: SAR.20070804 Seattle, WA 98104 Revision B This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1999 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2003, OET Bulletin 65 Supp. C, RSS-102 and Safety Code 6 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Certificate # 2387.01 FCC ID: UIQE1500 Model(s): E-1501a Novatel WWAN Modules: Model: EU860D, FCC ID: NBZNRM-EU860D Test Sample: Production Serial No.: MVT1-107 Equipment Type: Mini-Laptop with WWAN and WLAN Classification: Portable Transmitter Next to Body TX Frequency Range: 824 – 849 MHz, 1850 – 1910 MHz, 2412 – 2462 MHz Frequency Tolerance: ± 25 ppm Maximum RF Output: 850 MHz (GSM) – 24.3 dBm, 850 MHz (GPRS) – 27.4 dBm, (average rms) 850 MHz (WCDMA) – 24.6 dBm, 1900 MHz (GSM) – 21.3 dBm, 1900 MHz (GPRS) – 24.4 dBm, 1900 MHz (WCDMA) – 24.5 dBm, 2450 MHz – 14.0 dBm, Conducted Maximum RF Output: 850 MHz (GSM) – 33.3 dBm, 835 MHz (GPRS) – 33.4 dBm, (Peak Power) 850 MHz (WCDMA) – 27.6 dBm, 1900 MHz (GSM) – 30.6 dBm, 1900 MHz (GPRS) – 30.4 dBm, 1900 MHz (WCDMA) – 27.5 dBm Conducted Signal Modulation: DSSS, OFDM, GMSK, 8-PSK, WCDMA Antenna Type (Length): Internal 2450 MHz(Universal Scientific Industrial Co., Ltd P/N 200-0038-01{Main}, 200-0039-01{Aux}), 835/1900 MHz(Located on Mother Board) Battery: Std. (Vulcan P/N 200-0026-xx), Ext. (Vulcan P/N 200-0251-xx) Battery Pack Application Type: Class II FCC Rule Parts: Part 22, 24, 15.247 Industry Canada: RSS-102 FCC ID: UIQE1500 © 2007 RF Exposure Lab, LLC Page 2 of 250 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ...........................................................................................................................3 SAR Definition [5]......................................................................................................................3 2. SAR Measurement Setup .....................................................................................................4 Robotic System .........................................................................................................................4 System Hardware .....................................................................................................................4 System Description ...................................................................................................................4 E-Field Probe ............................................................................................................................5 3. Robot Specifications .............................................................................................................7 4. Probe and Dipole Calibration ................................................................................................8 5. Phantom & Simulating Tissue Specifications........................................................................9 SAM Phantom ...........................................................................................................................9 Brain & Muscle Simulating Mixture Characterization ................................................................9 Device Holder ...........................................................................................................................9 6. Definition of Reference Points.............................................................................................10 Ear Reference Point................................................................................................................10 Device Reference Points ........................................................................................................10 7. Test Configuration Positions ...............................................................................................11 Positioning for Cheek/Touch [5] ..............................................................................................11 Positioning for Ear / 15 ̊ Tilt [5]................................................................................................12 Body Worn Configurations ......................................................................................................13 8. ANSI/IEEE C95.1 – 1999 RF Exposure Limits [2]...............................................................14 Uncontrolled Environment.......................................................................................................14 Controlled Environment .......................................................................................................... 14 9. Measurement Uncertainty ...................................................................................................15 10. System Validation ........................................................................................................... 16 Tissue Verification................…
Text truncated - open the document above for the full version.
FCC ID: UIQE1500 © 2007 RF Exposure Lab, LLC Page 184 of 250 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Appendix D – Probe Calibration Data Sheets NCL CALIBRATION LABORATORIES Calibration File No.: CP-722 Client.: RFEL C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized procedures and using transfer standards traceable to NRC/NIST. Equipment: Miniature Isotropic RF Probe 835 MHz BODY Calibration Manufacturer: APREL Laboratories Model No.: E-020 Serial No.: 215 Calibration Procedure: SSI/DRB-TP-D01-032-E020-V2 Project No: RFEB-E020CAL-5261 Calibrated: 14 th February 2007 Released on: 14 th February 2007 APREL Laboratories Certified Under Laboratory 48 of SCC This Calibration Certificate is Incomplete Unless Accompanied with the Calibration Results Summary Released By: ______________________________________________________ NCL CALIBRATION LABORATORIES 51 SPECTRUM WAY Division of APREL Lab. NEPEAN, ONTARIO TEL: (613) 820-4988 CANADA K2R 1E6 FAX: (613) 820-4161 NCL Calibration Laboratories Division of APREL Laboratories. Page 2 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Introduction This Calibration Report reproduces the results of the calibration performed in line with the SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure. The results contained within this report are for APREL E-Field Probe E-020 215. References SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure IEEE 1528 “Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body Due to Wireless Communications Devices: Experimental Techniques” SSI-TP-011 Tissue Calibration Procedure IEC 62209 “Human exposure to radio frequency fields from hand-held and body- mounted wireless communication devices – Human models, instrumentation, and procedures –Part 1 & 2: Procedure to determine the Specific Absorption Rate (SAR) for hand-held devices used in close proximity of the ear (frequency range of 300 MHz to 3 GHz)” IEEE 1309 Draft Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9kHz to 40GHz Conditions Probe 215 was a re-calibration. Ambient Temperature of the Laboratory: 22 °C +/- 0.5°C Temperature of the Tissue: 21 °C +/- 0.5°C We the undersigned attest that to the best of our knowledge the calibration of this probe has been accurately conducted and that all information contained within this report has been reviewed for accuracy. ------------------------------------------------------------ Stuart Nicol ------------------------------------------------------------ Jesse Hones NCL Calibration Laboratories Division of APREL Laboratories. Page 3 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Calibration Results Summary Probe Type: E-Field Probe E-020 Serial Number: 215 Frequency: 835 MHz Sensor Offset: 1.56 mm Sensor Length: 2.5 mm Tip Enclosure: Ertalyte* Tip Diameter: <5 mm Tip Length: 60 mm Total Length: 290 mm *Resistive to recommended tissue recipes per IEEE-1528 Sensitivity in Air Channel X: 1.2 μV/(V/m) 2 Channel Y: 1.2 μV/(V/m) 2 Channel Z: 1.2 μV/(V/m) 2 Diode Compression Point: 95 mV NCL Calibration Laboratories Division of APREL Laboratories. Page 4 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Sensitivity in Body Tissue Frequency: 835 MHz Epsilon: 55.3 (+/-5%) Sigma: 1.08 S/m (+/-10%) ConvF Channel X: 6.3 Channel Y: 6.3 Channel Z: 6.3 Tissue sensitivity values were calculated using the load impedance of the APREL Laboratories Daq-Paq. Boundary Effect: Uncertainty resulting from the boundary effect is less than 2% for the distance between the tip of the probe and the tissue boundary, when less than 2.44mm. Spatial Resolution: The measured probe tip diameter is 5 mm (+/- 0.01 mm) and therefore meets the requirements of SSI/DRB-TP-D01-032 for spatial resolution. NCL Calibration Laboratories Division of APREL Laboratories. Page 5 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Receiving Pattern 835 MHz (Air) Receiving Pattern Probe s/n 215 835MHz 0 0.2 0.4 0.6 0.8 1 1.2 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 Ch1Ch2Ch3Tot NCL Calibration Laboratories Division of APREL Laboratories. Page 6 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Isotropy Error 835 MHz (Air) Isotropy Error Probe s/n 215 835MHz -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 0100200300 Error [dB] Isotropy Plot Probe s/n 215 835MHz 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0100200300 Degrees (x10) Voltage (mV) Ch1Ch2Ch3 Isotropicity Tissue: 0.10 dB NCL Calibration Laboratories Division of APREL Laboratories. Page 7 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Dynamic Range Probe 215 Dynamic Range 0.01 0.1 1 10 100 1000 10000 1.0010.00100.001,000.0010,000.00100,000.001,000,000.0010,000,000.00 Electric Field [(V/m)^2] Voltage [microV] Uncompensated Compensated NCL Calibration Laboratories Division of APREL Laboratories. Page 8 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Video Bandwidth Probe Frequency Characteristics -6 -5 -4 -3 -2 -1 0 1 110100100010000 Frequency (Hz) Probe output level (dB) Video Bandwidth at 500 Hz 1 dB Video Bandwidth at 1.02 KHz: 3 dB NCL Calibration Laboratories Division of APREL Laboratories. Page 9 of 10 This page has been reviewed for content and attested to on Page 2 of this document. Conversion Factor Uncertainty Assessment Sensitivity in Body Tissue Frequency: 835 MHz Epsilon: 55.3 (+/-5%) Sigma: 1.08 S/m (+/-10%) ConvF Channe…
Text truncated - open the document above for the full version.
Page 1 of 122 Report No: FC07-014 VULCAN PORTALS, INC. TEST REPORT FOR THE FLIPSTART E-1000 SERIES FCC PART 15 SUBPART C SECTIONS 15.247& 15.207, SUBPART B SECTIONS 15.107 & 15.109 CLASS B AND RSS-210 COMPLIANCE DATE OF ISSUE: MARCH 7, 2007 PREPARED FOR: Vulcan Portals, Inc. 505 5th Ave. South, Ste. 900 Seattle, WA 98104 PREPARED BY: Mary Ellen Clayton CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 P.O. No.: W.O. No.: 20185-00778 85535 Date of test: August 29, 2006 – March 7, 2007 Report No.: FC07-014 This report contains a total of 122 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein. Page 2 of 122 Report No: FC07-014 TABLE OF CONTENTS Administrative Information .............................................................................................4 FCC to Canada Standard Correlation Matrix...................................................................5 Conditions for Compliance ..............................................................................................6 Approvals .........................................................................................................................6 Equipment Under Test (EUT) Description ......................................................................7 FCC 15.31(e) Voltage Variation......................................................................................7 FCC 15.31(m) Number Of Channels ...............................................................................7 FCC 15.33(a) Frequency Ranges Tested .........................................................................7 FCC 15.203 Antenna Requirements ................................................................................7 EUT Operating Frequency ...............................................................................................7 Equipment Under Test (EUT) Description ......................................................................8 Equipment Under Test .....................................................................................................8 Peripheral Devices ...........................................................................................................9 Report of Measurements ..................................................................................................10 Table 1: FCC 15.107 Six Highest Conducted Emission Levels ..........................10 Table 2: FCC 15.109 Six Highest Radiated Emission Levels: 30-1000 MHz.....11 Table 3: FCC 15.109 Six Highest Radiated Emission Levels: 1-6 GHz .............12 Table 4: FCC 15.207 Six Highest Conducted Emission Levels ..........................13 FCC 15.247(a)(1) Frequency Separation .............................................................14 FCC 15.247(a)(1) Number Of Hopping Channels...............................................15 FCC 15.247(a)(1)(iii) Average Time Of Occupancy...........................................16 FCC 15.247(a)(1)(iii) Average Time Of Occupancy...........................................18 FCC 15.247(a)(2) 6 dB Bandwidth......................................................................24 FCC 15.247(b) Conducted RF Output Power......................................................30 Table 5: FCC 15.247(d) Six Highest Antenna Conducted Emission Levels .......33 Table 6: FCC 15.247(d) Six Highest Radiated Emission Levels.........................34 FCC 15.247(b) Output Power ..............................................................................35 Bandedge..............................................................................................................62 RSS-210 99% Bandwidth ....................................................................................68 Temperature And Humidity During Testing....................................................................77 EUT Setup........................................................................................................................77 Correction Factors............................................................................................................77 Table A: Sample Calculations .............................................................................77 Test Instrumentation and Analyzer Settings ....................................................................78 Spectrum Analyzer Detector Functions ...............................................................78 Peak..........................................................................................................78 Quasi-Peak ...............................................................................................78 Average ....................................................................................................78 EUT Testing.....................................................................................................................79 Mains Conducted Emissions................................................................................79 Antenna Conducted Emissions ............................................................................79 Radiated Emissions ..............................................................................................79 Page 3 of 122 Report No: FC07-014 Appendix A: Test Setup Photographs..............................................................................80 Photograph Showing Voltage Variation ..............................................................81 Photograph Showing Mains Conducted Emissions .............................................82 Photograph Showing Radiated Emissions ...........................................................83 Photograph Showing Radiated Emissions ...........................................................84 Photograph Showing Radiated Emissions ...................…
Text truncated - open the document above for the full version.
Module 5725 Part…
Text truncated - open the document above for the full version.
5046 Sierra Pines Dr. · Mariposa · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 24.00 mW |

FlipStart E-1000 Series
Equipment Class
PCB - PCS Licensed Transmitter
FlipStart E-1000 Series
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter