Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
F CC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar e designed to provide reasonable protection against harmful interference in a residential installation. T his equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance w ith the instructi o ns, may cause harmful interference to radio communications. However, t here is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference b y one or more of the following measures: • R eorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit dif ferent from that to which the receiver is connected. • Consult the dealer or an experienced radi o/TV technician for help. C aution: A ny changes or modifications to this device not explicitly approved by manufacturer could void your authority to ope r ate this equipment. T his device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesired operation. R F Exposure Information The device has been evaluated to meet general RF exposure requirement. T he device c an be used in portable exposure condition, compliance with exposure r equirements.
MANOVA International Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 7/1/2024 U.S. Agent Designation MA NOVA International Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: UKWMANOVABT208): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of MANOVA International Ltd.. MANOVA International Ltd. with the FRN 0015464795 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Since rely, Signature Wayne Man MANOVA International Ltd. Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
Page1of5FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.4 Fig.3 Page3of5FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of5FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 Page5of5FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9
Page1of1FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.0cmxW3.0cm) LabelLocation WirelessSpeaker TestModel:BT-208S FCCID:UKWMANOVABT208
Page1of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity . Fig.7 Fig.8 Page5of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.9 . Fig.10 BTAntenna Page6of6FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.11 Fig.12
Page1of4FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCRFExposureEvaluation 1.ProductInformation FCCID:UKWMANOVABT208 Productname:WirelessSpeaker TestModel:BT-208T,BT-208S,BT-208,BT-209,BT-180,BT-220,BTS-805, BT-216,BT-711,BTS-89,BT-218,BT-F16,BT-M208,BT-810, BT-816,BT-228,BT-229,BT-238,BT-239,BT-240,BT-241,BT-68 PowerSupply: Input:DC5V200mA Output:DC3.7V250mA HardwareVersion:/ SoftwareVersion/ Bluetooth:2402MHz~2480MHz ChannelNumber:79channelsforBluetoothV5.4(DSS) ChannelSpacing:1MHzforBluetoothV5.4(DSS) ModulationType:GFSK,π/4-DQPSKforBluetoothV5.4(DSS) BluetoothVersion:V5.4 AntennaType:PCBAntenna AntennaGain:1.9dBi Exposurecategory:Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:PortableDevice 2.EvaluationmethodandLimit AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1StandaloneSAR testexclusionconsiderations:“UnlessspecificallyrequiredbythepublishedRFexposureKDB procedures,standalone1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulation exposureconditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition,listedbelow,issatisfied.Thesetest exclusionconditionsarebasedonsource-basedtime-averagedmaximumconductedoutputpower oftheRFchannelrequiringevaluation,adjustedfortune-uptolerance,andtheminimumtest separationdistancerequiredfortheexposureconditions.22Theminimumtestseparationdistance isdeterminedbythesmallestdistancefromtheantennaandradiatingstructuresoroutersurfaceof thedevice,accordingtothehostformfactor,exposureconditionsandplatformrequirements,toany partofthebodyorextremityofauserorbystander(see5)ofsection4.1).ToqualifyforSARtest exclusion,thetestseparationdistancesappliedmustbefullyexplainedandjustifiedbythe operatingconfigurationsandexposureconditionsofthetransmitterandapplicablehostplatform requirements,typicallyintheSARmeasurementorSARanalysisreport,accordingtotherequired publishedRFexposureKDBprocedures.WhennootherRFexposuretestingorreportingis required,astatementofjustificationandcompliancemustbeincludedintheequipmentapproval,in lieuoftheSARreport,toqualifyfortheSARtestexclusion.Whenrequired,thedevicespecific conditionsdescribedintheotherpublishedRFexposureKDBproceduresmustbesatisfiedbefore applyingtheseSARtestexclusionprovisions;forexample,handheldPTTtwo-wayradios,handsets, laptops&tabletsetc.“ [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where: Page2of4FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity •f(GHz)istheRFchanneltransmitfrequencyinGHz •PoweranddistanceareroundedtothenearestmWandmmbeforecalculation •Theresultisroundedtoonedecimalplaceforcomparison •3.0and7.5arereferredtoasthenumericthresholdsinthestep2below Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmaccordingtof)insection4.1isappliedto determineSARtestexclusion. Whenoneofthefollowingtestexclusionconditionsissatisfiedforallcombinationsof simultaneoustransmissionconfigurations,furtherequipmentapprovalisnotrequiredto incorporatetransmittermodulesinhostdevicesthatoperateinthemixedmobileandportablehost platformexposureconditions.ThegranteeisresponsiblefordocumentingthisaccordingtoClassI permissivechangerequirements.AntennasthatqualifyforstandaloneSARtestexclusionmust applytheestimatedstandaloneSARtodeterminesimultaneoustransmissiontestexclusion. a)The[∑of(thehighestmeasuredorestimatedSARforeachstandaloneantennaconfiguration, adjustedformaximumtune-uptolerance)/1.6W/kg]+[∑ofMPEratios]is≤1.0. b)TheSARtopeaklocationseparationratiosofallsimultaneouslytransmittingantennapairs operatinginportabledeviceexposureconditionsareall≤0.04,andthe[∑ofMPEratios]is≤ 1.0. 3.ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication447498D01GeneralRFExposureGuidancev06:MobileandPortableDevices RFExposureProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices Page3of4FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.ConductedPowerResults <BT> ModeChannel Frequency(MHz)PeakConductedOutputPower(dBm) GFSK 02402 0.53 392441-0.31 782480 0.01 π/4DQPSK 02402 0.31 392441 -0.57 782480-0.24 5.ManufacturingTolerance <BT> GFSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 π/4DQPSK(Peak) ChannelChannel0Channel39Channel78 Target(dBm)000 Tolerance±(dB)1.01.01.0 6.EvaluationResults 6.1StandaloneEvaluation Band/Mode f (GHz) Antenna Distance (mm) RFoutputpower SARTest Exclusion Threshold SARTest Exclusion dBmmW BT GFSK 2.480 2 1.0 1.25890.3965<3.0Yes π/4DQPSK 2.441 2 1.0 1.25890.3934<3.0Yes Remark: 1.Outputpowerincludingtuneuptolerance; 2.Whentheminimumtestseparationdistanceis<5mm,adistanceof5mmaccordingtof)insection 4.1isappliedtodetermineSARtestexclusion. 6.2SimultaneousTransmissionforSARExclusion ThesamplesupportoneBTmodular.Noneedconsidersimultaneoustransmission. 7.Conclusion ThemeasurementresultscomplywiththeFCCLimitper47CFR2.1093fortheuncontrolledRF ExposureandSARExclusionThresholdperKDB447498v0…
Text truncated - open the document above for the full version.
Productspecification QuickReferenceDate Antennamoduleonthesystemboard FrequencRange2400~2500MHz Ant.PortInputPwr.(dBm)0(Typ.BTclass2outputpower) Tot.Rad.Pwr.(dBm)-1.2(Inputpwr–losspwr) PeakEIRP(dBm)1.2 Directivity(dBi)1 (alldirectionantenna) Efficiency(dB)60.2% Gain(dBi)1.9(AvgGainXY-plane) MaximumPower(dBm)1.7(XY-plane) MinimumPower(dBm)-4(XY-plane) Avg.Power(dBm)-0.5(XY-plane) InputImpendence(ohm)50 PolarizationTypeVertical&Horizontal V.S.W.R<1.4 Allthetechnicaldataandinformationcontainedhereinaresubjecttochangewithoutpriornotice AntennaLayout&moduleonthesystemboard AntennaGain GainTable [email protected] PeakAvg.PeakAvg.PeakAvg. ModuleBoard 1.2-0.51.9-3.61.1-3.060.2% RetumLoss TheEnvironmentofAntennaRadiationPattem 3Dradiationpatterndiagram XY-planeXZ-planeYZ-plane
Page 1 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixA RF Test Data for BT (ConductedMeasurement) ProductName:WirelessSpeaker Test Model:BT-208S EnvironmentalConditions Temperature: 23.8  C RelativeHumidity:52.1% ATM Pressure:10 0.0 kPa Test Engineer:Paddi Chen Supervisedby:Nick Peng Page 2 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dBBandwidth ConditionModeFrequency(MHz)Antenna-20 dB Bandwidth(MHz)Limit -20 dB Bandwidth(MHz)Verdict NVNT1-DH52402Ant11.018N/APass NVNT1-DH52441Ant10.964N/APass NVNT1-DH52480Ant11.024N/APass NVNT2-DH52402Ant11.278N/APass NVNT2-DH52441Ant11.279N/APass NVNT2-DH52480Ant11.285N/APass Page 3 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dBBandwidthNVNT1-DH52402MHzAnt1 -20dBBandwidthNVNT1-DH52441MHzAnt1 Page 4 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT1-DH52480MHzAnt1 -20dBBandwidthNVNT2-DH52402MHzAnt1 Page 5 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity -20dBBandwidthNVNT2-DH52441MHzAnt1 -20dBBandwidthNVNT2-DH52480MHzAnt1 Page 6 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.2MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT1-DH52402Ant10.5300.5321Pass NVNT1-DH52441Ant1-0.310-0.3121Pass NVNT1-DH52480Ant10.0100.0121Pass NVNT2-DH52402Ant10.3100.3121Pass NVNT2-DH52441Ant1-0.570-0.5721Pass NVNT2-DH52480Ant1-0.240-0.2421Pass Page 7 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PowerNVNT1-DH52402MHzAnt1 PowerNVNT1-DH52441MHzAnt1 Page 8 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT1-DH52480MHzAnt1 PowerNVNT2-DH52402MHzAnt1 Page 9 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity PowerNVNT2-DH52441MHzAnt1 PowerNVNT2-DH52480MHzAnt1 Page 10 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.3 CarrierFrequenciesSeparation ConditionModeAntennaHoppingFreq1(MHz)HoppingFreq2(MHz)HFS (MHz)Limit (MHz)Verdict NVNT1-DH5Ant12401.9622402.96210.679Pass NVNT2-DH5Ant12402.0022402.9380.9360.852Pass Page 11 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs CFS NVNT1-DH52402MHzAnt1 CFS NVNT2-DH52402MHzAnt1 Page 12 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity A.4 DwellTime ConditionModeFrequency (MHz) AntennaPulseTime (ms) Total Dwell Time (ms) Burst Count PeriodTime (ms) Limit (ms) Verdict NVNT1-DH52402Ant12.881299.62410431600400Pass NVNT2-DH52402Ant12.88311.0410831600400Pass Page 13 of 42FCC ID:UKWMANOVABT208ReportNo.: LCSA06034207EA ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 51…
Text truncated - open the document above for the full version.
Page 1 of 37 FCCID:UKWMANOVABT208ReportNo.:LCSA06034207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR MANOVAInternationalLtd. WirelessSpeaker TestModel:BT-208S AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:MANOVAInternationalLtd. Address: FlatA,13thFloor,CenturyIndustrialCentre,33-35AuPuiWan Street,FoTan,N.T,HongKong. Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample: June06,2024 Numberoftestedsamples: 2 SampleNo. : A240531053-1,A240531053-2 Serialnumber: Prototype DateofTest: June06,2024~June20,2024 DateofReport: June20,2024 Page 2 of 37 FCCID:UKWMANOVABT208ReportNo.:LCSA06034207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA06034207EA DateofIssue.......................................:June20,2024 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................: MANOVAInternationalLtd. Address................................................: FlatA,13thFloor,CenturyIndustrialCentre,33-35AuPuiWan Street,FoTan,N.T,HongKong. TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:WirelessSpeaker TradeMark..........................................:N/A TestModel...........................................:BT-208S Ratings.................................................: Input:DC5V200mA Output:DC3.7V250mA Result..................................................:Positive Compiledby:Supervisedby:Approvedby: JokerHu/Administrator CaryLuo/TechniqueprincipalGavinLiang/Manager Page 3 of 37 FCCID:UKWMANOVABT208ReportNo.:LCSA06034207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestResult Positive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA06034207EA June20,2024 Dateofissue TestModel.............................. : BT-208S EUT......................................... : WirelessSpeaker Applicant...............................:MANOVAInternationalLtd. Address...................................:FlatA,13thFloor,CenturyIndustrialCentre,33-35AuPui WanStreet,FoTan,N.T,HongKong. Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:MANOVAInternationalLtd. Address...................................: FlatA,13thFloor,CenturyIndustrialCentre,33-35AuPui WanStreet,FoTan,N.T,HongKong. Telephone...............................:/ Fax..........................................:/ Factory...................................: / Address...................................: / Telephone...............................:/ Fax..........................................:/ Page 4 of 37 FCCID:UKWMANOVABT208ReportNo.:LCSA06034207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000June20,2024InitialIssue--- Page 5 of 37 FCCID:UKWMANOVABT208ReportNo.:LCSA06034207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.GENERALINFORMATION.............................................................................................6 1.1DescriptionofDevice(EUT).....................................................................................................6 1.2HostSystemConfigurationListandDetails.............................................................................7 1.4DescriptionofTestFacility........................................................................................................7 1.5StatementoftheMeasurementUncertainty......................................................................…
Text truncated - open the document above for the full version.
Page1of2FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:UKWMANOVABT208 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.10 mW |

HANDi - Bluetooth Speaker with Power Bank
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
SWiNG Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Stereo Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Portable Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
"CUBIC" BLUETOOTH STEREO SPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter