It indicates tire air pressure and air temperature inside tire detected by sensor unit mounted on each tire and tire position. Detected data are compared with two preset management values, and when they are out of ranges of management values, the lamp at the tire position blinks, and the conditions are shown by figures and change of background color.Detected data can be stored in logger. Data in the logger can be read into PC. 5 Explanation of functions of HiTES Display 5.1. Functions of Display 5.2. Concerning language selection 5.3. Explanation of parts of Display Air pressure display screen TOPFront Tire position Comment indication cell Vehicle selection button * Simulated screen image Initial screen Time and date Repeater is connected or not Logger is connected or not Trailer is connected or not 8 7 Setting when new sensor is mounted and informa-tion updating when tire rotation is implemented, for example, can be carried out.Touch panel is adopted for the indicator. Various operations can be performed by pushing buttons on the screen shown in each display.*Be sure to operate and confirm indicator while vehicle is parked.Language selection screen is displayed only at initial start. Select either Japanese or English.* Language can be selected from setting menu. LED Indicator Occurrence of tire abnor-mality is informed by means of color Tire air pressure (kPa)Background color (state of display position)Blue: NormalYellow or Red: Air pressure is insufficient.White: No received data Air temperature inside tire (°C)Background color (state of display position)Blue: NormalYellow or Red: High temperatureWhite: No received data Position selection buttonPosition to be displayed is selected using and . Switching of initial screen Position indication during display: Position blinks during display. (Background color represents state.) Function of automatic indication of all positions: All positions are sequentially indicated when wheel arrange- ment diagram is touched. Indication of tire air pressureButton for switching display * Simulated screen image Information indication portionInformation concerning State of occurrence of red and yellow, State of idle capacity of logger, Easy help for error, etc. is indicated. Button for switching to setting menu screen(Long push until screen changes.)When separation of trailer is forgotten, it is changed to [Trailer selection] button.
20 20 -00) -10) -00) -10)
Photo CPTLSNSC-00 Photo CPTLSNSC-00 Photo CPTLSNSC-00
Photo CPTLSNSC-10 Photo CPTLSNSC-10 Photo CPTLSNSC-10
COPYRIGHT© YOKOHAMA RUBBER. All rights reserved. CPTLSNSC-00 FCC ID, IC Number Model This device will be installed in vehicle and end-user cannot see the label. According to FCC Rules § 15.19, FCC compliance statement will be included in User Manual, because it is not practical to place it on the device. COPYRIGHT© YOKOHAMA RUBBER. All rights reserved. CPTLSNSC-10 FCC ID, IC Number Model This device will be installed in vehicle and end-user cannot see the label. According to FCC Rules § 15.19, FCC compliance statement will be included in User Manual, because it is not practical to place it on the device.
Test report No. : 10096184S-A Page : 2 of 20 Issued date : December 25, 2013 Revised date : August 27, 2014 FCC ID : UNK-Y001YUA1120 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 REVISION HISTORY Original Test Report No.: 10096184S-A Revision Test report No. Date Page revised Contents - (Original) 10096184S-A December 25, 2013 - - 1 10096184S-A December 26, 2013 6 7 Correction of Test location Addition of Software information 2 10096184S-A August 27, 2014 5 13 16 Correction of Worst Margin Correction of Limit and Margin Correction of title Test report No. : 10096184S-A Page : 3 of 20 Issued date : December 25, 2013 FCC ID : UNK-Y001YUA1120 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Contents Page SECTION 1: Customer information ....................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ......................................................................... 4 SECTION 3: Test specification, procedures & results .......................................................... 5 SECTION 4: Operation of E.U.T. during testing ................................................................... 7 SECTION 5: Automatically deactivate ................................................................................... 8 SECTION 6: Radiated emission (Fundamental and Spurious emission) ............................ 9 SECTION 7: 20dB bandwidth & Occupied bandwidth (99%) ........................................... 11 Contents of APPENDIXES ...................................................................................................... 12 APPENDIX 1: Data of radio tests .......................................................................................... 13 APPENDIX 2: Test instruments ............................................................................................ 17 APPENDIX 3: Photographs of test setup .............................................................................. 18 Test report No. : 10096184S-A Page : 4 of 20 Issued date : December 25, 2013 FCC ID : UNK-Y001YUA1120 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 1: Customer information Company Name : THE YOKOHAMA RUBBER CO.,LTD Address : 2-1 Oiwake, Hiratsuka, Kanagawa 254-8601 Japan Telephone Number : +81-463-35-9574 Facsimile Number : +81-463-35-9756 Contact Person : Yasuhiko Araki SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : HiTES Sensor Model No. : CPTLSNSC-00 Serial No. : Refer to 4.2 in this report. Rating : DC3.0V Receipt Date of Sample : October 29, 2013 Country of Mass-production : Japan Condition of EUT : Production model Modification of EUT : No modification by the test lab. 2.2 Product description Model: CPTLSNSC-00 (referred to as the EUT in this report) is a. HiTES Sensor. Clock frequency(ies) in the system : 9.84MHz, 2MHz <Radio part> Equipment type : Transmitter Frequency of operation : 314.88MHz Type of modulation : FSK Antenna type : Magnetic field type loop antenna Antenna Gain : -24.149dBi max Operating temperature range : -20 to +70 deg.C Emission designation : F1D FCC 15.31 (e) The test was performed with a new battery (DC3.0V) and the stable voltage was supplied to the EUT during the tests. Therefore, the EUT complies with the requirement. FCC 15.203 The equipment and its antenna comply with this requirement since the antenna is mounted inside of the EUT. Test report No. : 10096184S-A Page : 5 of 20 Issued date : December 25, 2013 Revised date : August 27, 2014 FCC ID : UNK-Y001YUA1120 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : Test specification: FCC Part 15 Subpart C: 2013, final revised on September 30, 2013 and effective October 30, 2013 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.207 Conducted limits Section 15.209 Radiated emission limits, general requirements Section 15.231 Periodic operation in the band 40.66 - 40.70 MHz and above 70 MHz 3.2 Procedures & Results Item Test Procedure SpecificationRemarksDeviationWorst Margin Results Conducted emission ANSI C63.4:2009 7. AC powerline conducted emission measurements FCC 15.207 - N/A *1) N/A N/A Automatically deactivate ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.231 (e) RadiatedN/A - Complied Electric field strength of Fundamental emission ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.231(e) RadiatedN/A 13.2dB Freq.: 314.885MHz Polarization: Horizontal Complied Electric field strength of Spurious emission ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.205 FCC 15.209 FCC 15.231 (e) RadiatedN/A 12.8dB Freq.: 944.655MHz Polarization: Horizontal Detector: Peak with Duty Factor Complied 20dB bandwidth ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.231 (c) RadiatedN/A - - Note: UL Japan’s Work Procedures No. 13-EM-W0420 and 13-EM-W0422 *1) The test is not applicable since the EUT does not have AC Mains. 3.3 Addition to standard Item Test Procedure SpecificationRemarksWorst Margin Results Occupied Bandwidth (99%) ANSI C63.4:2009 13. Measurement of intentional radiators, RSS-Gen 4.6.1 RSS-210 A1.1.3 RSS-Gen 4.6.1 Radiated - - Note: UL Japan’s Work Procedures No. 13-EM-W0420 and 13-EM-W0422 * Other than above, no addition, exclusion nor deviation has been made from the standard. Test report No. : 10096184S-A Page : 6 of 20 Issued date : December 25, 2013 Revised date : December 26, 2013 FCC ID : UNK-…
Text truncated - open the document above for the full version.
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 APPENDIX 3: Photographs of test setup Radiated emission Front view Rear view (9kHz-30MHz) Loop antenna: Horizontal Loop antenna: Vertical Report No. : 10096184S-A 18 of 20 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Rear view (30-1000MHz) Rear view (1-4GHz) Report No. : 10096184S-A 19 of 20 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Pre-check of the worst position X-axis Y-axis Z-axis END OF REPORT Report No. : 10096184S-A 20 of 20
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231(e) | 314.88 MHz - 314.88 MHz | - |

AIR PRESSURE TRANSMITTER
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Air Pressure Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter