FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zinwave Ltd/
  3. UPO308-0007-2

UPO308-0007-2308-0007-2 Distributed Antenna System Remote Unit

Zinwave Ltd
308-0007-2 Distributed Antenna System Remote Unit - FCC ID UPO308-0007-2 - Zinwave Ltd
Click to zoom

Application Details

Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
Dec 08, 2022
Application Purpose
Original Equipment
Date of Application
Dec 08, 2022
Equipment Note
308-0007-2 Distributed Antenna System Remote Unit
Frequency Range
2496.00000000 - 2690.00000000
Company
Zinwave Ltd
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

In-Building Wireless Solution User Manual Software Version 5.21 Uniwave User Manual Copyright © 2022 Zinwave. All rights reserved. i © 2016-2022 Zinwave Ltd All Rights Reserved Zinwave retains all ownership rights to all computer programs offered by Zinwave, their products, and the contents of this manual. The source code for both software and firmware are confidential trade secrets of Zinwave. You may not attempt to decipher, decompile, develop or otherwise reverse engineer Zinwave software, firmware, or products. Information necessary to achieve interoperability is furnished upon request. This manual is furnished under license and may only be used or copied in accordance with the terms of such license. The information in the manual is furnished for informational use only, is subject to change without notice, and should not be construed as commitment by Zinwave. Zinwave assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording, or otherwise, without the express written permission of Zinwave. Existing artwork or images that you may desire to scan may be protected by copyright law. Be sure to obtain permission for use of existing artwork. Trademarks This product carries the Trademark of Zinwave, Ltd. All the trademarks of component parts used by Zinwave in the manufacture of this product are the property of their respective owners. The Zinwave logo is a registered trademark of Zinwave All brand or product names are trademarks or registered trademarks of their respective companies or organizations. Warranty The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Zinwave disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Zinwave shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Zinwave and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control Copyright © 2022 Zinwave. All rights reserved. ii Table of Contents Safety and Regulatory Information ................................................... vii Safety Information ............................................................................................................................ vii RF Exposure ...................................................................................................................... vii Installation .......................................................................................................................... vii Signal and Input Power ..................................................................................................... vii Fiber Considerations ........................................................................................................ viii Optical Safety Precautions ................................................................................................. ix Software Installation ........................................................................................................... ix Symbols ............................................................................................................................... x Regulatory Information ....................................................................................................................... x UL NRTL Listing ................................................................................................................. xi FCC .................................................................................................................................... xi Innovation, Science and Economic Development Canada Compliance Statement ... Error! Bookmark not defined. CE Information .................................................................... Error! Bookmark not defined. RoHS Information ............................................................... Error! Bookmark not defined. UKCA Information ............................................................... Error! Bookmark not defined. About this Manual ............................................................................. xiii Intended Audience .......................................................................................................................... xiii Conventions xiii Getting Help xiii 1 System Overview ..................................................................... 1-1 1.1 How Does It Work? ................................................................................................... 1-1 1.2 Key Features ............................................................................................................. 1-2 1.3 Network Topologies .................................................................................................. 1-2 1.3.1 Single-Star Configuration ................................................................................. 1-2 1.3.2 Double Star Configuration ............................................................................... 1-3 1.3.3 Mixed Topology Configuration ......................................................................... 1-3 1.3.4 Support for MIMO Services ............................................................................. 1-4 1.4 Understanding Optional Components ....................................................................... 1-5 1.4.1 How the …

Text truncated - open the document above for the full version.

Cover Letter(s)

Sulis Consultants Limited Mead House, Longwater Road, Eversley, Hampshire, RG27 0NW, UK Registered in England & Wales, number 05466247 http://www.sulisconsultants.com 29 November 2022 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: UPO308-0007-2 To whom it may concern Pursuant to sections 0.457(d) and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: • Schematics • Bills of Materials • Block Diagram • Operational Description • Tune-up procedure Zinwave has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Yours Sincerely Charlie Blackham Director

Cover Letter(s)

Zinwave Ltd is registered in England Registered Number: 4587255 VAT Number: GB918532122 Registered office Zinwave Ltd Harston Mill Harston, Cambridge, CB22 7GG November 29, 2022 Agent Authorization Company: Zinwave Ltd Address: Harston Mill, Harston, Cambridge, CB22 7GG, UK Product Name: UNItivity 5000 Remote Unit Model Number(s): 308-0007-2 Product Description: Wideband DAS We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. James Martin VP Operations

Cover Letter(s)

Zinwave Ltd is registered in England Registered Number: 4587255 VAT Number: GB918532122 Registered office Zinwave Ltd Harston Mill Harston, Cambridge, CB22 7GG November 29, 2022 Agent Authorization Company: Zinwave Ltd Address: Harston Mill, Harston, Cambridge, CB22 7GG, UK Product Name: UNItivity 5000 Remote Unit Model Number(s): 308-0007-2 Product Description: Wideband DAS We authorize Sulis Consultants Ltd, Mead House, Longwater Road, Eversley, RG27 0NW, UK, to act on our behalf on all matters concerning the certification of above named equipment. We declare that Sulis Consultants Ltd. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by Sulis Consultants Ltd on our behalf shall have the same effect as acts of our own. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. James Martin VP Operations

RF Exposure Info

FCC EM Field exposure calculation calculation RF Exposure – USA The 308-0007-2 remote unit is installed in a fixed location and designed to be used > 20cm from the body. The device is designed to be used with a variety of antennas and EMF calculations have been done using 8dBi antenna which is higher gain than any of the recommended options so represents worst case for all of them. Demonstration of compliance • As the product is installed in a fixed location, the power density can be calculated at 20cm and compared to the permitted exposure limits • The product operates over a wide frequency range: o Worst case for 30-300 MHz band is operation at 150 MHz o Worst case for 300-1500 MHz region is operation at 406.1 MHz Using the equation S= 푃퐺 4π푅 2 , the exposure level at 20 cm can be calculated and compared against the limit P: power input to antenna in W G: numeric gain of antenna relative to isotropic radiator S: power density limit in W/m 2 R: distance for evaluation in m, which is 0.2 Freq band Freq (MHz) Total rated antenna port power (2 ports) (dBm) EIRP (W) S (W/m 2 ) FCC limit (W/m 2 ) > 1500 MHz 1930.0 27.0 3.16 6.29 10.0 Table 1: Calculated Exposure levels at 20 cm

Test Report

Page 1 of 42 File Name: Zinwave Ltd.13924-1 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 24 2021 Radio Test Report Zinwave Ltd Zinwave UNItivity 5000 Remote Unit 308-0007-2 47 CFR Part 24 Effective Date 1st October 2021 47 CFR Part 2 Effective Date 1st October 2021 Test Date: 7 th to 18 th November 2022 Report Number: 11-13927-1-22 Issue 01 R.N. Electronics Ltd. Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.RNelectronics.com Telephone: +44 (0) 1277 352219 Email: [email protected] This report is not to be reproduced by any means except in full and in any case not without the written approval of R.N. Electronics Ltd. ©2022 RN ELECTRONICS LIMITED REPORT NUMBER: 11-13927-1-22 Issue 01 ALL RIGHTS RESERVED Page 2 of 42 File Name: Zinwave Ltd.13924-1 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 24 2021 Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test 13927-1 The equipment noted below has been fully tested by R.N. Electronics Limited and, where appropriate, conforms to the relevant subpart of FCC Part 24. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment: Zinwave UNItivity 5000 Remote Unit Model Number: 308-0007-2 Unique Serial Number: Sample #2 (T4237) Applicant: Zinwave Ltd Harston Mill, Royston Road Harston, Cambridge CB22 7GG Proposed FCC ID UPO308-0007-2 Full measurement results are detailed in Report Number: 11-13927-1-22 Issue 01 Test Standards: 47 CFR Part 24 Effective Date 1st October 2021 47 CFR Part 2 Effective Date 1st October 2021 NOTE: Certain tests were not performed based upon manufacturer's declarations. Certain other requirements are subject to manufacturer declaration only and have not been tested/verified. For details refer to section 3 of this report. This report only pertains to the operation of the equipment to 47 CFR part 24, for details of testing to other rule parts please see RN report: 11-13927-2-22 (Part 27). DEVIATIONS: No deviations have been applied. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Federal Regulations, particularly under different conditions to those during testing. Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to the FCC and (b) the modes of operation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Date Of Test: 7th to 18th November 2022 Test Engineer: Approved By: Radio Manager Customer Representative: ©2022 RN ELECTRONICS LIMITED REPORT NUMBER: 11-13927-1-22 Issue 01 ALL RIGHTS RESERVED Page 3 of 42 File Name: Zinwave Ltd.13924-1 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 24 2021 1 Contents 1 Contents .......................................................................................................................................................... 3 2 Equipment under test (EUT) ........................................................................................................................... 4 2.1 Equipment specification ......................................................................................................................... 4 2.2 Configurations for testing ....................................................................................................................... 5 2.3 Functional description ............................................................................................................................ 6 2.4 Modes of operation ................................................................................................................................ 6 2.5 Emissions configuration ......................................................................................................................... 7 3 Summary of test results .................................................................................................................................. 7 4 Specifications .................................................................................................................................................. 9 4.1 Relevant standards .................................................................................................................................. 9 4.2 Deviations ................................................................................................................................................ 9 5 Tests, methods and results ........................................................................................................................... 10 5.1 Spurious emissions at antenna terminals ............................................................................................ 10 5.2 RF Power Output ................................................................................................................................. 14 5.3 Frequency stability ............................................................................................................................... 16 5.4 Occupied bandwidth / Input versus output signal ....................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 55 File Name: Zinwave Ltd.13927-2 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 27 Radio Test Report Zinwave Ltd Zinwave UNItivity 5000 Remote Unit 308-0007-2 47 CFR Part 27 Effective Date 1st October 2021 47 CFR Part 2 Effective Date 1st October 2021 Test Date: 7 th to 18 th November 2022 Report Number: 11-13927-2-22 Issue 01 R.N. Electronics Ltd. Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.RNelectronics.com Telephone: +44 (0) 1277 352219 Email: [email protected] This report is not to be reproduced by any means except in full and in any case not without the written approval of R.N. Electronics Ltd. ©2022 RN ELECTRONICS LIMITED REPORT NUMBER: 11-13927-2-22 Issue 01 ALL RIGHTS RESERVED Page 2 of 55 File Name: Zinwave Ltd.13927-3 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 27 2020 Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test 13927-2 The equipment noted below has been fully tested by R.N. Electronics Limited and, where appropriate, conforms to the relevant subpart of FCC Part 27. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment: Zinwave UNItivity 5000 Remote Unit Model Number: 308-0007-2 Unique Serial Number: Sample #2 (T4237) Applicant: Zinwave Ltd Harston Mill, Royston Road Harston, Cambridge CB22 7GG Proposed FCC ID UPO308-0007-1 Full measurement results are detailed in Report Number: 11-13927-2-22 Issue 01 Test Standards: 47 CFR Part 27 Effective Date 1st October 2021 47 CFR Part 2 Effective Date 1st October 2021 NOTE: Certain tests were not performed based upon manufacturer's declarations. Certain other requirements are subject to manufacturer declaration only and have not been tested/verified. For details refer to section 3 of this report. This report only pertains to the operation of the equipment to 47CFR part 27, for details of testing to other rule parts please see RN reports: 11-13927-1-22 (Part 24E). DEVIATIONS: No deviations have been applied. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Federal Regulations, particularly under different conditions to those during testing. Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to the FCC and (b) the modes of operation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Date Of Test: 7th to 18th November 2022 Test Engineer: Approved By: Radio Manager Customer Representative: ©2022 RN ELECTRONICS LIMITED REPORT NUMBER: 11-13927-2-22 Issue 01 ALL RIGHTS RESERVED Page 3 of 55 File Name: Zinwave Ltd.13927-3 Issue 01 QMF21J - Issue 05 - RNE Issue 03; FCC Part 27 2020 1 Contents 1 Contents .......................................................................................................................................................... 3 2 Equipment under test (EUT) ........................................................................................................................... 4 2.1 Equipment specification ......................................................................................................................... 4 2.2 Configurations for testing ....................................................................................................................... 5 2.3 Functional description ............................................................................................................................ 6 2.4 Modes of operation ................................................................................................................................ 6 2.5 Emissions configuration ......................................................................................................................... 7 3 Summary of test results .................................................................................................................................. 8 4 Specifications .................................................................................................................................................. 9 4.1 Relevant standards .................................................................................................................................. 9 4.2 Deviations ................................................................................................................................................ 9 5 Tests, methods and results ........................................................................................................................... 10 5.1 Spurious emissions at antenna terminals ............................................................................................ 10 5.2 RF Power Output ................................................................................................................................. 16 5.3 Frequency stability ............................................................................................................................... 18 5.4 Occupied bandwidth / Input versus output signal ........................................…

Text truncated - open the document above for the full version.

Test Setup Photos

J13927-1 & -2 test set-up Photos 1.1 Below 1GHz 1.2 Above 1GHz

Contact Information

Applicant

Ken Trayling(Design Centre Manager & Principal RF Engineer)
[email protected]01223771350Fax: +44 (0)1223 875243

Technical Contact

Zinwave Ltd
[email protected]

United Kingdom

Test Firm

Kiwa LtdClint Hilling
[email protected]44 1277 352219

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
6272.50 GHz - 2.69 GHz500.00 mWW9WAmp
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted composite power based on one carrier. The transmit antenna must be fixed-mounted on permanent structures, be installed to provide a separation distance of at least 0.2 m from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization.

Other Applications from Zinwave Ltd

Zinwave 2765 Distributed Antenna System - FCC ID UPO2765 - Zinwave Ltd
UPO2765

Zinwave 2765 Distributed Antenna System

Apr 12, 2007

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Zinwave 2700 Distributed Antenna System - FCC ID UPO2760 - Zinwave Ltd
UPO2760

Zinwave 2700 Distributed Antenna System

Nov 16, 2006

Equipment Class

PCB - PCS Licensed Transmitter