
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Note: Product images shown may be different than actual product received. Cable connectors at the other end of the cable provide an interface to other systems for communications, to allow local downloading and to provide power. Additionally some cables allow connecting peripherals such as check readers and printers. All of the cable connectors are labeled and color-coded, as follows: • DC Power - Connects AC power adapter to the Q30 • RS232A (Blue, RJ11 6P4C), RS232B (Yellow, RJ11 6P4C), or RS232 on C302 hub cable (RJ11 6P6C) - Connects an external POS device or check reader • RS232 (Black, DB9-F) – Used to connect to POS terminal • USB-Host (Type A) or Micro USB 2.0 - Used for local terminal downloads or external peripherals • LAN (Red, Ethernet, RJ45-F) - Used for bi-directional Ethernet connections, TMS, and/or payment processing • Powered USB - to connect to POS/ECR systems Quick Setup Guide PAX™ Q30 Payment Terminal Box Contents Box Contents Communication cable (cable type varies by configuration) AC power adapter (included in some configurations) • 1 - PAX™ Q30 payment terminal • 1 - Communication cable (varies by configuration) • 1 - AC power adapter (not included with PUSB configurations) • 1 - Privacy shield • 1 - Quick Setup Guide Product Description Product Description Stylus pen Contactless reader Camera Touch screen Speaker(inside) Magnetic stripe reader Privacy shield Keypad Smart card reader Back cover MAC label Regulatory label Part number/ serial number label Screw Screw(under rubber foot) Reset button Audio jack Cable Connectors Cable Connectors 3 2x7P connector The 2x7P connector end of the provided communication cable connects to the underside of the Q30. A combination of the following ports are available on the communication cable (depending on the Q30 configuration): Privacy shield Note: Stylus pen is an optional configuration for the terminal, it may be not support on actual product received. P/N:200312000000402 9 10 Power down and remove all power from the Q30. Unscrew and open back cover. Gently press and slide SIM or Micro SD door toward outer edge of terminal and open hinged door. Seat card with gold connectors down into slot, aligning with opening. Gently press and slide door toward center of terminal to lock door closed. Close Q30 back cover and tighten back cover screw. Audio JackAudio Jack WARNING: Power down the terminal before installing SIM cards or Micro SD cards. If the terminal is still powered on during an attempted SIM or SD card installation or removal, both the terminal and the card can be damaged irreparably. Audio Jack is an optional configuration for the terminal, it may be not support on actual product received. If required, a visually disabled person can connect a headphone to the terminal for audio prompting if the terminal application supports this using the 3.5mm output audio jack. Terminal Location 11 Terminal Location Insert metal stand prongs into three stand slots on underside of terminal. Slide terminal firmly into place on stand. Stand Installation 12 Stand Installation Do not use industrial strength or abrasive cleaner as it may damage or scratch the screen. • Do not immerse device in water (or liquid). • Do not spray water or cleaner into EMV Card Reader or ports. • To clean screen, apply distilled water or mild glass cleaner onto a soft, lint-free cloth and gently wipe terminal screen. • To clean terminal, apply distilled water or plastic-safe cleaner onto a soft, lint-free cloth and gently wipe terminal. Attach 2x7P Connector Attach 2x7P Connector 4 To connect 2x7P end of cable: 1. Loosen the screw on the underside of the Q30 using a Philips head screwdriver. 2. Open the back cover. 3. Place the 2x7P end of the provided communication cable over its port, but do not push into place. 4. Align rubber sliding pull restraint so that it seats into its notch on the Q30. 5. Firmly press the 2x7P end of the cable into the port. 6. Close the back cover and tighten the screw, ensuring the gasket is properly seated in the opening. DO NOT connect the other end to the AC power source until all the other cables are connected first. Plugging in the AC power cord to the power source before the other cables are installed may result in damage to the terminal or connected devices. WARNING: Power Connections Power Connections 5 Power can be supplied to the Q30 by connecting the AC power adapter to the data cable, as in the case of RS232 or USB configurations, or via a powered USB cable (12V Powered USB) where the connected POS terminal provides the power. The Q30 supports the following types of communications: • RS232 • High Speed Ethernet • USB 2.0 • Powered USB • Bluetooth BLE 4.0 + Wi-Fi (optional) Terminal Communications Terminal Communications 6 SIM and Micro SD Card Installation 8 SIM and Micro SD Card Installation To install a SIM and/or Micro SD card: Reset Button 9 Reset Button To reset the terminal, press and hold the reset button for 4-6 seconds. using a pen or similar item. An example of when this may be used is when you are performing a download via USB stick. Locate the terminal on a counter top, desktop, or table top. It is recommended to keep the terminal away from direct sunlight, excessive dust, moisture, and heat. Avoid locating the terminal near electrical devices that might introduce interference such as microwave ovens and blow dryers. Cleaning the Device 13 Cleaning the Device WARNING: Caution: Changes or modifications not expressly approved by PAX Technology could void the user’s authority to operate the equipment. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Certifications 14 Certifications The Q30 passed the following certifications: • PCI PTS 5.x, SRED • EMV L1 & L2 • EMV CL L1 • Mastercard PayPass • American Express Expresspay • Discover D-PAS • Visa payWave • JCB J/Speedy • Interac Flash • FCC • IC • CE • UL • RoHS 10 CAUTION: If the…
Text truncated - open the document above for the full version.
PAX Technology Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020-10-28 Subject; Request for Confidentiality FCC ID: V5PQ30LRC To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Xudong An Title: Manager
Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 24 of 39 8 EUT Constructional Details Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 25 of 39 Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 26 of 39 Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 27 of 39 Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 28 of 39 Report No: JYTSZE200903401 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009034 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 29 of 39
label location label location
Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 29 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 30 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 31 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 32 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 33 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 34 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 35 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 36 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 37 of 38 Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 38 of 38 ------End of report------
JianYan Testing Group Shenzhen Co., Ltd. Report No: JYTSZE200903201V01 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT Applicant: PAX Technology Limited Address of Applicant: Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road, Wanchai, Hong Kong Equipment Under Test (EUT) Product Name: POS Terminal Model No.: Q30 Trade mark: PAX FCC ID: V5PQ30LRC Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.225 Date of sample receipt: 11 Sep., 2020 Date of Test: 11 Sep., to 27 Oct., 2020 Date of report issue: 28 Oct., 2020 Test Result: PASS* * In the configuration tested, the EUT complied with the standards specified above. Report No: JYTSZE200903201V01 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 40 2 Version Version No. Date Description 00 28 Oct., 2020 Original 01 10 Nov., 2020 Update Chapter 4 Tested by: Date: 28 Oct., 2020 Test Engineer Reviewed by: Date: 28 Oct., 2020 Project Engineer Report No: JYTSZE200903201V01 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 40 3 Contents Page 1 COVER PAGE ................................................................................................................................................... 1 2 VERSION ........................................................................................................................................................... 2 3 CONTENTS ....................................................................................................................................................... 3 4 TEST SUMMARY .............................................................................................................................................. 4 5 GENERAL INFORMATION .............................................................................................................................. 5 5.1 CLIENT INFORMATION ............................................................................................................................................ 5 5.2 GENERAL DESCRIPTION OF E.U.T. ....................................................................................................................... 5 5.3 TEST MODE AND TEST SAMPLES PLANS ................................................................................................................ 5 5.4 DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5 5.5 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ...................................................................... 6 5.7 LABORATORY FACILITY.......................................................................................................................................... 6 5.8 LABORATORY LOCATION ....................................................................................................................................... 6 5.9 TEST INSTRUMENTSLIST ........................................................................................................................................ 7 6 TEST RESULTS AND MEASUREMENT DATA ............................................................................................. 8 6.1 ANTENNA REQUIREMENT ....................................................................................................................................... 8 6.2 RADIATED EMISSION ............................................................................................................................................. 9 6.3 20DB BANDWIDTH ............................................................................................................................................... 16 6.4 FREQUENCY TOLERANCE .................................................................................................................................... 18 6.5 CONDUCTED EMISSION ....................................................................................................................................... 20 7 TEST SETUP PHOTOS .................................................................................................................................. 23 8 EUT CONSTRUCTIONAL DETAILS ................................................................................................................... 25 Report No: JYTSZE200903201V01 JianYan Testing Group Shenzhen C…
Text truncated - open the document above for the full version.
Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 23 of 38 7 Test Setup Photos Radiated Emission 9kHz-30MHz 30MHz-1000MHz Report No: JYTSZE200903201 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZE2009032 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 24 of 38 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
UNATTENDED PAYMENT TERMINAL
Equipment Class
DTS - Digital Transmission SystemSmart Multilane
Equipment Class
DTS - Digital Transmission SystemUnattended Payment Terminal
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterPOS Terminal
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSmart Payment Terminal
Equipment Class
DTS - Digital Transmission System