305 Commerce Drive Moorestown, NJ 08057-4234 Phone:(856)727-1100 Fax:(856)222-4847 Letter of Agency I appoint Intertek Testing Services NA Inc. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under the FCC rules until further notice. I further certify that no party (as defined in 1.2002 of CFR 47, 1995) to this application, including myself, is subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,853A. Equipment: iBOT, 2032610 Dated this Seventh day of June, two-thousand and seven. Signature Michael Powell Name Senior Member of Technical Staff Title 856-727-1100 ext 2267 Telephone
305 Commerce Drive Moorestown, NJ 08057-4234 Phone:(856)727-1100 Fax:(856)222-4847 Attention: Application Examiner Re: Request for confidentiality Applicant: OPEX Corporation FCC ID: VDM2032610, VDM2033210 To whom it may concern, Request is hereby submitted by OPEX Corporation to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block diagrams • Detailed Operational/Functional Description • Parts list • Internal photos • User manual Rationale for request for confidentiality: OPEX Corporation has invested considerable time and materials in research and development to produce the referenced products. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. Permanent confidentiality of internal photos and User manual of the referenced products is requested due to the specific requirement for licensee appointed service and installation of the referenced products. If you have questions or need further information, please contact the undersigned. Sincerely, Michael Powell Senior Member of Technical Staff OPEX Corporation
305 Commerce Drive Moorestown, NJ 08057-4234 Phone:(856)727-1100 Fax:(856)222-4847 Attention: Application Examiner Re: Request for limited Modular Approval Applicant: OPEX Corporation FCC ID: VDM2032610, VDM2033210 IC ID: 7175A-2032610, 7175A-2033210 This letter requests authorization of an unlicensed, low power “transmitter module” for operation under FCC Part 15 and RSS-210 Rules. Specifically requested is a “Limited Modular Approval.” 1. This modular transmitter doesn’t have its own RF shielding. 2. This modular transmitter has buffered modulation/data inputs. 3. This modular transmitter has its own power supply regulation. 4. This modular transmitter complies with the antenna requirements of Section 15.203 and 15.204(c). The antenna employs a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). 5. The modular transmitter was tested in a stand-alone configuration. The modular transmitter complies with the AC line conducted requirements. AC or DC power lines and data input/output lines connected to the module do not contain ferrites. 6. The modular transmitter is labeled with its own FCC ID and IC ID. 7. The modular transmitter complies with FCC Part 15.249 and RSS-210 Rules. 8. The modular transmitter complies with any applicable RF exposure requirements. Compliance with one or more of the numbered requirements, listed above, could not be demonstrated; therefore a “Limited Modular Approval” (LMA) is requested. The Grantee will retain control over the final installation of the device, such that compliance of the end product is assured. In such a case, an operating condition on the grant of equipment authorization for the module is requested to state that the module is only approved for use when installed in devices produced by a the Grantee. This letter is making clear the fact that LMA is requested. The Grantee is in control of the design, manufacture and installation of the modular transmitter and ensures compliance. Sincerely, Michael Powell OPEX Corporation Compliance Engineer
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TEST REPORT Report Number: 3125815LEX002 Project Number: 3125815 Evaluation of the iBOT Model Number: 2032610 FCC ID: VDM2032610 Industry Canada ID: 7175A-2032610 FCC Part 15 Subpart B & FCC Part 15 Subpart C ICES-003 & RSS-210 Issue 6 For Opex Incorporated Test Performed by: Test Authorized by: Intertek 731 Enterprise Drive Lexington, KY 40510 Opex Incorporated 305 Commerce Drive Moorestown, NJ 08057 Prepared By:_______________________________Date:____11/14/2007________ Jason Centers, Senior Project Engineer Approved By:______________________________Date:____11/14/2007_________ Bryan C. Taylor, Team Leader Intertek 731 Enterprise Drive, Lexington, KY 40510 Telephone: 859-226-1000 Fax: 859-226-1040 Web: www.etlsemko.com 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Opex Incorporated FCC ID: VDM2032610 Model No: 2032610 IC ID: 7175A-2032610 Report Number: 3125815LEX002 Page 2 of 22 FCC Part 15, ICES-003 & RSS-210 Evaluation TABLE OF CONTENTS 1 JOB DESCRIPTION .......................................................................................................................... 3 1.1 COMPANY INFORMATION............................................................................................................ 3 1.2 TEST SAMPLE INFORMATION....................................................................................................... 3 1.3 SYSTEM SUPPORT EQUIPMENT.................................................................................................... 3 1.4 CABLES USED DURING TESTING................................................................................................. 4 1.5 SYSTEM BLOCK DIAGRAM(S) ...................................................................................................... 4 1.6 MODE(S) OF OPERATION / ENGINEERING JUDGMENTS................................................................ 4 2 EXECUTIVE SUMMARY................................................................................................................. 5 2.1 MODIFICATIONS REQUIRED FOR COMPLIANCE............................................................................ 5 3 TEST FACILITY................................................................................................................................ 6 3.1 TEST EQUIPMENT......................................................................................................................... 6 4 FIELD STRENGTH OF SPURIOUS RADIATION ....................................................................... 7 4.1 TEST PROCEDURE........................................................................................................................ 7 4.2 TEST RESULTS............................................................................................................................. 9 5 RADIATED RECEIVER EMISSIONS .......................................................................................... 14 5.1 TEST PROCEDURE...................................................................................................................... 14 5.2 TEST RESULTS........................................................................................................................... 15 6 CONDUCTED VOLTAGE EMISSIONS....................................................................................... 17 6.1 TEST METHOD: .......................................................................................................................... 17 6.2 TEST RESULTS: .......................................................................................................................... 18 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Opex Incorporated FCC ID: VDM2032610 Model No: 2032610 IC ID: 7175A-2032610 Report Number: 3125815LEX002 Page 3 of 22 FCC Part 15, ICES-003 & RSS-210 Evaluation 1 JOB DESCRIPTION 1.1 Company Information Company Information Manufacturer: Opex Incorporated Address: 305 Commerce Drive Moorestown, NJ 08057 Contact Name: Michael Powell Telephone Number: (856) 727-1100 Email Address: [email protected] 1.2 Test Sample Information The Opex iBOT is a small radio controlled robotic vehicle which runs in a track system as part of a larger automated sorting machine. Test sample Model Number: 2032610 Serial Number: Not Labeled FCC ID: VDM2032610 Device Category: Mobile RF Exposure Category: General Population/Uncontrolled Environment Transmission: Zigbee, 0-QPSK Modulation Frequency Range (MHz) 2405-2480 Antenna Type: PCB Antenna Antenna Location: Internal 1.3 System Support Equipment The support equipment used during the evaluation is listed in the table below. Support Equipment Used in Setup Description Manufacturer Model Number Serial Number Laptop Compaq Evo N410c 7E32KX21C02H Exhibit 1 . 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Opex Incorporated FCC ID: VDM2032610 Model No: 2032610 IC ID: 7175A-2032610 Report Number: 3125815LEX002 Page 4 of 22 FCC Part 15, ICES-003 & RSS-210 Evaluation 1.4 Cables Used During Testing Cables Connection Description Length Shielding Ferrites From To CAT…
Text truncated - open the document above for the full version.
305 Commerce Drive · Moorestown · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Wireless Transceiver
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Wireless Transceiver
Equipment Class
DTS - Digital Transmission SystemWireless Transceiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter