VGYAP962C802.11ax Ceiling-mount Access Point

Draytek Corporation
802.11ax Ceiling-mount Access Point - FCC ID VGYAP962C - Draytek Corporation
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jun 19, 2024
Application Purpose
Original Equipment
Date of Application
Jun 18, 2024
Equipment Note
802.11ax Ceiling-mount Access Point
Frequency Range
5570.00000000 - 5570.00000000
Company
Draytek Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 VigorAP 962C 802.11ax Ceiling-mount Access Point Quick Start Guide Version: 1.0 Firmware Version: V1.5.4 (For future update, please visit DrayTek web site) Date: June 12, 2024 2 Intellectual Property Rights (IPR) Information Copyrights © All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders. Trademarks The following trademarks are used in this document:  Microsoft is a registered trademark of Microsoft Corp.  Windows, Windows 8, 10, 11 and Explorer are trademarks of Microsoft Corp.  Apple and Mac OS are registered trademarks of Apple Inc.  Other products may be trademarks or registered trademarks of their respective manufacturers. Safety Instructions and Approval Safety Instructions  Read the installation guide thoroughly before you set up the device.  The device is a complicated electronic unit that may be repaired only be authorized and qualified personnel. Do not try to open or repair the device yourself.  Do not place the device in a damp or humid place, e.g. a bathroom.  Do not stack the devices.  The device should be used in a sheltered area, within a temperature range of 0 to +40 Celsius.  Do not expose the device to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources.  Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards.  Do not power off the device when saving configurations or firmware upgrades. It may damage the data in a flash. Please disconnect the Internet connection on the device before powering it off when a TR-069/ ACS server manages the device.  Keep the package out of reach of children.  When you want to dispose of the device, please follow local regulations on conservation of the environment. Warranty We warrant to the original end user (purchaser) that the device will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore-store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value, and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects which do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes. 3 Declaration of Conformity Hereby, DrayTek Corporation declares that the equipment type VigorAP 962C is in compliance with Radio Equipment Directive 2014/53/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://fw.draytek.com.tw/VigorAP%20962C/Document/CE/ Manufacturer: DrayTek Corp. Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan Product: VigorAP 962C Frequency Information for Europe area: 2.4GHz WLAN 2412MHz - 2472 MHz, max. TX power: 19.23 dBm 5GHz WLAN 5160MHz - 5340 MHz, max. TX power: 22.92 dBm 5480MHz - 5720 MHz, max. TX power: 29.94 dBm Requirements in AT/BE/BG/CZ/DK/EE/FR/DE/IS/IE/IT/EL/ES/ CY/LV/LI/LT/LU/HU/MT/NL/NO/PL/PT/RO/SI/SK/TR/FI/SE/CH/HR/UK(NI). 5150MHz~5350MHz is for indoor use only. This product is designed for 2.4GHz and 5GHz WLAN network throughout the EC region. Declaration of Conformity Hereby, DrayTek Corporation declares that the equipment type VigorAP 962C is in compliance with the Radio Equipment Regulations 2017 (SI 2017 No.1206) , The Electrical Equipment (Safety) Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032). The full text of the UKCA Declaration of Conformity is available at the following internet address: https://fw.draytek.com.tw/VigorAP%20962C/Document/CE/ Manufacturer: DrayTek Corp. Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan Product: VigorAP 962C Frequency Information for UK area: 2.4GHz WLAN 2412MHz - 2472 MHz, max. TX power: 19.23 dBm 5GHz WLAN 5160MHz - 5340 MHz, max. TX power: 22.92 dBm 5480MHz - 5720 MHz, max. TX power: 29.94 dBm Requirements in UK. 5150MHz~5350MHz is for indoor use only. This product is designed 2.4GHz and 5GHz WLAN network use in the UK & Ireland. Importer UK - CMS Distribution Limited, 15 Worship Street, London, EC2A 2DT Ireland - CMS Distribution Limited, Bohola Road, Kiltimagh, Co Mayo, Ireland 4 UK PSTI STATEMENT OF COMPLIANCE We, DrayTek Corp., office at No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole responsibility that the product The full text of the PSTI Declaration of Conformity is available at the following internet address: https://fw.draytek.com.tw/UK/PSTI/  Product name: 802.11ax Ceiling-mount Access Point  Model number: VigorAP 962C  Manufacturer: DrayTek Corp.  Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan is in conformity with the relevant UK Statutory Instruments: Th…

Text truncated - open the document above for the full version.

Attestation Statements

Draytek Corporation CERTIFICATIONS CONCERNING “COVERED” EQUIPMENT Date: 2024-05-31 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 FCC ID: VGYAP962C To Whom It May Concern: As required by section 2.911(d)(5)(i), [Draytek Corporation] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. As required by section 2.911(d)(5)(ii), [Draytek Corporation] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Thank you for your attention to this matter. Sincerely yours, Signature Printed Name: Abbott Yu Company: Draytek Corporation Job Title: Director Email: ayu@draytekcom Telephone: 03-5972727

Attestation Statements

2024/6/6

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 (Draytek Corporation) Declaration of Authorization We Name:Draytek Corporation Address:No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park City:Hsinchu Country:Taiwan Declare that: Name Representative of agent: Ms. Rose Liu (1) Agent Company name:BTL Inc. Address:No.3 Jinshagang 1st Road, Shixia, Dalang Town City:Dong Guan CountryChina is authorized to apply for Certification of the following product(s): Product description: 802.11ax Ceiling-mount Access Point Type designation: VigorAP 962C Trademark: DrayTek Validity/ expiry date: 2025-05-31 on our behalf. Date:2024-05-31 City:Hsinchu Name:Abbott Yu (2) Function: Director Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 Company Name:Draytek Corporation Address:No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park City:Hsinchu Country:Taiwan To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: VGYAP962C Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. Date: 2024-05-31Name and signature of applicant: Abbott Yu Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Project No.: 2312G131A Page 2 of 16 Project No.: 2312G131A Page 3 of 16 Project No.: 2312G131A Page 4 of 16 Project No.: 2312G131A Page 5 of 16

Internal Photos

Project No.: 2312G131A Page 6 of 16 2.4G Ant.2 5G Ant.3 2.4G Ant.1 5G Ant.2 5G Ant.1 Project No.: 2312G131A Page 7 of 16 Project No.: 2312G131A Page 8 of 16 Project No.: 2312G131A Page 9 of 16 Project No.: 2312G131A Page 10 of 16 Project No.: 2312G131A Page 11 of 16 Project No.: 2312G131A Page 12 of 16 Project No.: 2312G131A Page 13 of 16 Project No.: 2312G131A Page 14 of 16 Project No.: 2312G131A Page 15 of 16 Project No.: 2312G131A Page 16 of 16

RF Exposure Info

Report No.: BTL-FCCP-4-2312G131A Page 1 of 5 FCC RF EXPOSURE REPORT FCC ID: VGYAP962C This report concerns: Original Grant Project No. Equipment Brand Name Test Model Series Model Applicant Address : 2312G131A : 802.11ax Ceiling-mount Access Point : DrayTek : VigorAP 962C : N/A : Draytek Corporation : No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park,Hsinchu, Taiwan 303 Manufacturer : Shenzhen Cudy Technology Co., Ltd. Address : Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, Shenzhen, China Factory : Shenzhen Cudy Technology Co., Ltd. Address : Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, Shenzhen, China Date of Receipt : Feb. 04, 2024 Date of Test : Feb. 21, 2024 ~ May 22, 2024 Jun. 14, 2024 Issued Date : Jun. 17, 2024 Report Version : R01 Test Sample : Engineering Sample No.: SSL2024020480 Standard(s) : FCC Guidelines for Human Exposure IEEE C95.1 & FCC Part 2.1091 FCC Title 47 Part 2.1091 & KDB 447498 D01 v06 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Grani Zhou Approved by : Chay Cai Room 108, Building 2, No.1, Yile Road, Songshan Lake Zone, Dongguan City, Guangdong, People’s Republic of China Te l : +86- 769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-4-2312G131A Page 2 of 5 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-FCCP-4-2312G131A R00 Original Report. May 31, 2024 Invalid BTL-FCCP-4-2312G131A R01 Modified the comments. Jun. 17, 2024 Valid Report No.: BTL-FCCP-4-2312G131A Page 3 of 5 1. MPE CALCULATION METHOD Calculation Method of RF Safety Distance: w here: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna 2. ANTENNA SPECIFICATION For 2.4GHz: Ant. Brand P/N Antenna Type Connector Gain (dBi) 1 3.N101.1181 PIFA N/A 4.29 2 3.N101.1182 PIFA N/A 4.33 Note: 1)This EUT supports MIMO, any transmit signals are correlated with each other, so Directional gain=10log[(10 G1/20 +10 G2/20 +...10 GN/20 ) 2 /N]dBi, that is Directional gain=10log[(10 4.29/20 +10 4.33/20 ) 2 /2]dBi =7.32. 2)Beamforming Gain is 3dBi. So direction gain = 3+4.33=7.33. 3)The antenna gain and beamforming gain are provided by the manufacturer. F or 5GHz: Ant. Brand P/N Antenna Type Connector Gain (dBi) 1 3.N101.1183 PIFA N/A 5.18 2 3. N101.1184 Monopole N/A 6.83 3 3.N101.1185 PIFA N/A 4.96 Note: 1)This EUT supports MIMO, any transmit signals are correlated with each other, so Directional gain=10log[(10 G1/20 +10 G2/20 +...10 GN/20 ) 2 /N]dBi, that is Directional gain=10log[(10 5.18/20 +10 6.83/20 +10 4.96/20 ) 2 /3 ]dBi =10.47. 2) Beamforming Gain is 4.77dBi. So direction gain = 4.77+6.83=11.60. 3)The antenna gain and beamforming gain are provided by the manufacturer. Report No.: BTL-FCCP-4-2312G131A Page 4 of 5 3. TABLE FOR ANTENNA CONFIGURATION For 2.4GHz_Non Beamforming: Operating Mode TX Mode 2TX IEEE 802.11b V(Ant. 1 + Ant. 2) IEEE 802.11g V(Ant. 1 + Ant. 2) IEEE 802.11n(HT20) V(Ant. 1 + Ant. 2) IEEE 802.11n(HT40) V(Ant. 1 + Ant. 2) IEEE 802.11ax(HE20) V(Ant. 1 + Ant. 2) IEEE 802.11ax(HE40) V(Ant. 1 + Ant. 2) F or 2.4GHz_Beamforming: Operating Mode TX Mode 2TX IEEE 802.11n(HT20) V(Ant. 1 + Ant. 2) IEEE 802.11n(HT40) V(Ant. 1 + Ant. 2) IEEE 802.11ax(HE20) V(Ant. 1 + Ant. 2) IEEE 802.11ax(HE40) V(Ant. 1 + Ant. 2) For 5GHz_Non Beamforming: Operating Mode TX Mode 3TX IEEE 802.11a V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11n(HT20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11n(HT40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT80) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT160) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE80) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE160) V (Ant. 1 + Ant. 2 + Ant. 3) F or 5GHz_ Beamforming: Operating Mode TX Mode 3TX IEEE 802.11n(HT20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11n(HT40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT80) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ac(VHT160) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE20) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE40) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE80) V (Ant. 1 + Ant. 2 + Ant. 3) IEEE 802.11ax(HE160) V (Ant. 1 + Ant. 2 + Ant. 3) Report No.: BTL-FCCP-4-2312G131A Page 5 of 5 4. CALCULATED RESULT F or 2.4GHz_ Non Beamforming: Directional gain (dBi) Directional gain (numeric) Max. Output Power (dBm) Max. Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 7.32 5.3951 25.62 364.7539 0.32372 1 Complies F or 2.4GHz_ Beamforming: Directional gain (dBi) Directional gain (numeric) Max. Output Power (dBm) Max. Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 7.33 5.4075 24.12 258.2260 0.22970 1 Complies Fo r 5GHz_ Non Beamforming: Directional gain (dBi) Directional gain (numeric) Max. Output Power (dBm) Max. Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 10.47 11.1429 25.50 354.8134 0.65038 1 Complies Fo r 5GHz_ Beamforming: Directional gain (dBi) Directional gain (numeric) Max. Output Power (dBm) Max. Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 11.60 14.4544 24.37 273.5269 0.65038 1 Complies For t he max simultaneous transmission MPE: Ratio Total Limit of Ratio Test Result 2.4GHz 5GHz 0.32372 0.65038 0.9741 1 Complies N ote: The calculated distance is 22 cm. E nd of Test Report

Test Report

Report No.: BTL-FCCP-2-2312G131A Page 1 of 351 FCC Radio Test Report FCC ID: VGYAP962C This report concerns: Original Grant Project No. : 2312G131A Equipment : 802.11ax Ceiling-mount Access Point Brand Name : DrayTek Test Model : VigorAP 962C Series Model : N/A Applicant : Draytek Corporation Address : No.26, Fu Shing Rd., HuKou County, Hsinchu Industrial Park,Hsinchu, Taiwan 303 Manufacturer : Shenzhen Cudy Technology Co., Ltd. Address : Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, Shenzhen, China Factory : Shenzhen Cudy Technology Co., Ltd. Address : Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan District, Shenzhen, China Date of Receipt : Feb. 04, 2024 Date of Test : Feb. 21, 2024 ~ May 22, 2024 Jun. 14, 2024 Issued Date : Jun. 17, 2024 Report Version : R01 Test Sample : Engineering Sample No.: SSL2024020480 Standard(s) : FCC CFR Title 47, Part 15, Subpart E The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Grani Zhou Approved by : Chay Cai Room 108, Building 2, No.1, Yile Road, Songshan Lake Zone, Dongguan City, Guangdong, People’s Republic of China Te l : +86-769-8318-3000 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-2-2312G131A Page 2 of 351 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025: 2017 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-2-2312G131A Page 3 of 351 Table of Contents Page REPORT ISSUED HISTORY 6 1 . APPLICABLE STANDARDS 7 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 2.3 TEST ENVIRONMENT CONDITIONS 9 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 TEST MODES 14 3.3 PARAMETERS OF TEST SOFTWARE 20 3.4 DUTY CYCLE 24 3.5 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 27 3.6 SUPPORT UNITS 27 3.7 CUSTOMER INFORMATION DESCRIPTION 27 4 . AC POWER LINE CONDUCTED EMISSIONS 28 4.1 LIMIT 28 4.2 TEST PROCEDURE 28 4.3 DEVIATION FROM TEST STANDARD 28 4.4 TEST SETUP 29 4.5 EUT OPERATION CONDITIONS 29 4.6 TEST RESULTS 29 5 . RADIATED EMISSIONS 30 5.1 LIMIT 30 5.2 TEST PROCEDURE 31 5.3 DEVIATION FROM TEST STANDARD 32 5.4 TEST SETUP 32 5.5 EUT OPERATION CONDITIONS 34 5.6 TEST RESULTS - 9 KHZ TO 30 MHZ 34 5.7 TEST RESULTS - 30 MHZ TO 1000 MHZ 34 5.8 TEST RESULTS - ABOVE 1000 MHZ 34 6 . BANDWIDTH 35 6.1 LIMIT 35 6.2 TEST PROCEDURE 35 Report No.: BTL-FCCP-2-2312G131A Page 4 of 351 Table of Contents Page 6.3 DEVIATION FROM STANDARD 35 6.4 TEST SETUP 36 6.5 EUT OPERATION CONDITIONS 36 6.6 TEST RESULTS 36 7 . MAXIMUM OUTPUT POWER 37 7.1 LIMIT 37 7.2 TEST PROCEDURE 37 7.3 DEVIATION FROM STANDARD 37 7.4 TEST SETUP 37 7.5 EUT OPERATION CONDITIONS 37 7.6 TEST RESULTS 37 8 . POWER SPECTRAL DENSITY 38 8.1 LIMIT 38 8.2 TEST PROCEDURE 38 8.3 DEVIATION FROM STANDARD 38 8.4 TEST SETUP 39 8.5 EUT OPERATION CONDITIONS 39 8.6 TEST RESULTS 39 9 . FREQUENCY STABILITY 40 9.1 LIMIT 40 9.2 TEST PROCEDURE 40 9.3 DEVIATION FROM STANDARD 40 9.4 TEST SETUP 40 9.5 EUT OPERATION CONDITIONS 40 9.6 TEST RESULTS 40 10 . MEASUREMENT INSTRUMENTS LIST 41 11 . EUT TEST PHOTOS 44 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 50 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 53 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 58 APPENDIX D - RADIATED EMISSION - ABOVE 1000 MHZ 61 APPENDIX E - BANDWIDTH 188 APPENDIX F - MAXIMUM OUTPUT POWER 221 Report No.: BTL-FCCP-2-2312G131A Page 5 of 351 Table of Contents Page APPENDIX G - POWER SPECTRAL DENSITY 282 APPENDIX H - FREQUENCY STABILITY 347 Report No.: BTL-FCCP-2-2312G131A Page 6 of 351 REPORT ISSUED HISTORY Report No. Version Description Issued Date Note BTL-FCCP-2-2312G131A R00 Original Report. May 31, 2024 Invalid BTL-FCCP-2-2312G131A R01 Modified the comments. Jun. 17, 2024 Valid Report No.: BTL-FCCP-2-2312G131A Page 7 of 351 1. APPLICABLE STANDARDS According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: ANSI C63.10-2013 The following reference test guidance is not within the scope of accreditation of A2LA: KDB 789033 D02 General UNII Test …

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-2-2312G131A Page 146 of 351 Test Mode UNII-2C_TX AX(HE40) Mode 5510 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 147 of 351 Test Mode UNII-2C_TX AX(HE40) Mode 5510 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 148 of 351 Test Mode UNII-2C_TX AX(HE40) Mode 5550 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 149 of 351 Test Mode UNII-2C_TX AX(HE40) Mode 5670 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 150 of 351 Test Mode UNII-2C_TX AX(HE40) Mode 5670 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 151 of 351 Test Mode UNII-2C_TX AX(HE80) Mode 5530 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 152 of 351 Test Mode UNII-2C_TX AX(HE80) Mode 5530 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 153 of 351 Test Mode UNII-2C_TX AX(HE80) Mode 5610 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 154 of 351 Test Mode UNII-2C_TX AX(HE80) Mode 5610 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 155 of 351 Test Mode UNII-2C_TX AX(HE160) Mode 5570 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 156 of 351 Test Mode UNII-2C_TX AX(HE160) Mode 5570 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 157 of 351 Test Mode UNII-3_TX A Mode 5745 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 158 of 351 Test Mode UNII-3_TX A Mode 5745 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 159 of 351 Test Mode UNII-3_TX A Mode 5785 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 160 of 351 Test Mode UNII-3_TX A Mode 5825 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 161 of 351 Test Mode UNII-3_TX A Mode 5825 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 162 of 351 Test Mode UNII-3_TX AC(VHT20) Mode 5745 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 163 of 351 Test Mode UNII-3_TX AC(VHT20) Mode 5745 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 164 of 351 Test Mode UNII-3_TX AC(VHT20) Mode 5785 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 165 of 351 Test Mode UNII-3_TX AC(VHT20) Mode 5825 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 166 of 351 Test Mode UNII-3_TX AC(VHT20) Mode 5825 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 167 of 351 Test Mode UNII-3_TX AC(VHT40) Mode 5755 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 168 of 351 Test Mode UNII-3_TX AC(VHT40) Mode 5755 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 169 of 351 Test Mode UNII-3_TX AC(VHT40) Mode 5795 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 170 of 351 Test Mode UNII-3_TX AC(VHT40) Mode 5795 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) Margin Level = Measurement Value - Limit Value. Report No.: BTL-FCCP-2-2312G131A Page 171 of 351 Te s t Mode UNII-3_TX AC(VHT80) Mode 5775 MHz Polarization Horizontal REMARKS: (1) Measurement Value = Reading Level + Correct Factor. (2) …

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-2-2312G131A Page 208 of 351 Test Mode UNII-2C_TX AC(VHT80) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 106 5530 98.390 75.600 122 5610 80.390 75.200 CH106 CH122 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 209 of 351 Test Mode UNII-2C_TX AC(VHT160) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 114 5570 167.990 153.600 CH114 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 210 of 351 Test Mode UNII-2C_TX AX(HE20) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 100 5500 28.000 19.300 116 5580 22.850 19.100 140 5700 26.100 19.300 CH100 CH116 CH140 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 211 of 351 Test Mode UNII-2C_TX AX(HE40) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 102 5510 48.900 38.200 110 5550 39.608 38.000 134 5670 50.400 38.400 CH102 CH110 CH134 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 212 of 351 Test Mode UNII-2C_TX AX(HE80) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 106 5530 90.600 77.200 122 5610 81.200 77.200 CH106 CH122 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 213 of 351 Test Mode UNII-2C_TX AX(HE160) Mode Channel Frequency (MHz) 26 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 114 5570 162.000 156.800 CH114 26 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A Page 214 of 351 Test Mode UNII-3_TX A Mode Channel Frequency (MHz) 6 dB Bandwidth (MHz) 99 % Occupied Bandwidth (MHz) 6 dB Bandwidth Min. Limit (MHz) Result 149 5745 16.350 19.100 0.5 Complies 157 5785 16.450 20.500 0.5 Complies 165 5825 16.350 20.100 0.5 Complies CH149 CH157 CH165 6 dB Bandwidth 99 % Occupied Bandwidth Report No.: BTL-FCCP-2-2312G131A P…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Abbott Yu(HW manager)
[email protected]+886-35972727Fax: +886-35972121

Technical Contact

BTL Inc.Steven Lu
[email protected]86-769-83183000

No.3 Jinshagang 1st Rd, Shixia, Dalang · China

Non-Technical Contact

BTL Inc.Rose Liu
[email protected]86-769-83183000

Test Firm

BTL Inc.Sophia Huang
[email protected]+86-769-83183000

Technical Specifications

#Rule PartsFrequency RangePower Output
615E5.57 GHz - 5.57 GHz86.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The device with its internal antenna must be installed to provide a separation distance of at least 22 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with operating conditions for satisfying RF exposure compliance.

Other Applications from Draytek Corporation

VGYAP1070C

VigorAP 1070C 802.11be Ceiling-mount Access Point

Feb 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
35b Security Router, Gigabit Broadband Router - FCC ID VGY2767AX - Draytek Corporation
VGY2767AX

35b Security Router, Gigabit Broadband Router

Sep 10, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
802.11ax Ceiling-mount AP - FCC ID VGYAP1062C - Draytek Corporation
VGYAP1062C

802.11ax Ceiling-mount AP

Mar 29, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Vigor Router 11ax Series - FCC ID VGY2765AX - Draytek Corporation
VGY2765AX

Vigor Router 11ax Series

Sep 27, 2022

Equipment Class

DTS - Digital Transmission System
35b & G.Fast Security Router - FCC ID VGY2865AX - Draytek Corporation
VGY2865AX

35b & G.Fast Security Router

Apr 12, 2021

Equipment Class

DTS - Digital Transmission System