Instruction manual 1. The compact florescent energy saving lamp fit easily into any socket. but the voltage must be AC120V/60Hz. 2. It usec 5 times less energy than incandescent bulb. 3. Risk of electric shock; use in dry location only. 4. When the line power is applied, don’t touch the glass bulb with your fingers, otherwise the hot bulb may burn your fingers. 5. The CFL not for use with dimmer. 6. Not for use in totally enclosed recessed fixture. 7. Please hold the plastic encl osure fit the lamp into any standard lighting socket, because the long bulb may be broken by holding force. 8. Usage environmental temperature :-10°C~50°C 9. Usage Circumstance: Be suitable for family, hotel, restaurant, office, supermarket etc. 10. Warning: This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45–30 MHz. Variations of this language are permitted provided all the points of the statement are addressed and may be presented in any legible font or text style. 11. Suitable for damp location.
Block diagram: Block diagram: Block diagram: Block diagram: AC Input Rectification circuit DC Filter circuit Inverter circu its ( ) 120V/60Hz Control circuits Start-up Lamp 40-50kHz Frequency
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT View
EXHIBIT A - FCC ID LABEL AND LOCATION FCC ID Label FCC ID Label Location Label here
EXHIBIT C - EUT INTERNAL PHOTOGRAPHS EUT – Cover off View EUT – Main Board Top View EUT – Main Board Bottom View
MODEL MDT3S13GU24 COMPONENT MANUFACTURER MODEL RATINGS UL FILE NO. 1 PCB DONG YANG BIDA ENTERPRISE ELECTRONICS CO LTD S01 120°C V-1 E304228 2 FUSE (L) SHENZHEN GREAT ELECTRONICS CO LT D RXF-1W 0.47Ω φ3.5×9 E301541 3 Resistor R1,R2 fenghua-advanced TECHNOLOGY HOLDING co., ltd 1206 330KΩ / 4 Resistor R3,R4 fenghua-advanced TECHNOLOGY HOLDING co., ltd 1206 15Ω / 5 Capacitor C1, C4, C5,C6,C7 Changing zaichuang electronic co.,ltd Changing qixing electronic co.,ltd C1: CL21 C4,C5: CL11 C6,C7: CH11 C1: 104/400V CL21 C5:473/400V CL11 C7:272/1200V CH11 C6:332/1200V CH11 C4:102/1200V CL11 / 6 Electrolytic Capacitor C2 Yiyang zijiang electronic element co., ltd Nantong yipinjixie Electronic Co., Ltd 125°C 200V/10μF) / Voltage:1000V 7 Diode D1~ D5 Changzhou galaxy electrical co., ltd. M7 Current:1 A / Voltage:28V 8 Diode DB3 Changzhou galaxy electrical co., ltd. DB3 Current:3 A / EB203DL Voltage:200V Current:1.5A / 9 Transistor (Q1,Q2) Shenzhen SYS semiconductors co., ltd / Boody magnetoelectricity technology co.,ltd. EE16 1.5-1.7mH QAL/155 φ0.29 169(T) / Changshu south-east plastic co.,ltd PF2A5-151J(b) V-0 150C E136137 Suzhou jingyi special adhesive tape co ltd Adhesive Tape JY312(#) 130C E188295 Shangrao wire factory of Jiangxi xinxin industrial co.,ltd Magnet wire QAL/155 @# 155°C E229727 10 Choke trans (L2) JINGJIANG JINGYI ADHESIVE PRODUCT CO LTD JY25-A# 130°C E246950 Pattern: φ6×8 1mHφ0.15×200T / Voltage:600v / Boody magnetoelectricity technology co.,ltd Main trans. Current:2A / Shangrao wire factory of Jiangxi xinxin industrial co.,ltd Magnet wire QAL/155 @# 155°C E229727 11 Main trans. (L1) Suzhou jingyi special adhesive tape co ltd Adhesive Tape JY312(#) 130°C E188295 shanghai plastic wire factory 1015 24# 105°C 600 V ac E109819 Wuhan jingweiELECTRONICS WIRE & CABLE CO LTD 1015 24# 105°C 600 V ac E323810 12 Lead wire(L) SUZHOU JINJIU WIRE & CABLE CO LTD 1015 24# 105°C 600 V ac E230305 haining xinghuo Electronic Co., Ltd φ9×5×3 3:10:3 440~520μH / 13 O trans (T1) Shangrao wire factory of Jiangxi xinxin industrial co.,ltd Magnet wire QAL/155 φ0.35 @# 155°C E229727 Jiang yin yongtong chemical co ltd PBT-4308G30 0.9mm 130°C E139063 14 Plastics GUANGZHOU KINGFA SCIENCE & TECHNOLOGY CO LTD PBT-RG301(r1) V-0 130°C E171666 15 Glassfiber Shenzhen wahchangwei ind ustrialco.,ltd SGS-15 UL VW-1 1mm 200°C E233804 SHENZHEN FUNGLI GLASS PRODUCTS CO LTD FSG φ1mm E238355 16 H-Heat shinkable tubing Shenzhen WOER heat-shrinkable material co., ltd RSFR-H 125°C VW-1 H E203950 17 Capacitor SMD C3 Changing zaichuang electronic co.,ltd Changing qixing electronic co.,ltd X7R223 ±10%-100V -0805 / 18 Diode D6/D7 No mounted / / /
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government. * This report contains data that are not covered by the NVLAP accreditation and are marked with an asterisk “★” (Rev.2) FCC PART 18 TEST REPORT For Jiangxi Midea Guiya Green Lighting Electrical Co., Ltd. Guixi Industrial District, Guixi, Jiangxi, China FCC ID: VGZT3S13GU Report Type: Original Report Product Type: CFL Test Engineer: Lebron Wang Report Number: RSZ111110550-00 Report Date: 2012-04-07 Reviewed By: Lisa Zhu EMC Engineer Test Laboratory: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: RSZ111110550-00 FCC Part 18 Page 2 of 13 TABLE OF CONTENTS GENERAL INFORMATION ...................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 3 OBJECTIVE................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................ 3 TEST METHODOLOGY.................................................................................................................................................. 3 TEST FACILITY............................................................................................................................................................ 3 SYSTEM TEST CONFIGURATION ......................................................................................................................... 5 JUSTIFICATION............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE.......................................................................................................................................... 5 SPECIAL ACCESSORIES................................................................................................................................................ 5 EQUIPMENT MODIFICATIONS....................................................................................................................................... 5 EXTERNAL I/O CABLE................................................................................................................................................. 5 CONFIGURATION OF TEST SETUP................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP................................................................................................................................6 FCC §18.307 - AC LINE CONDUCTED EMISSIONS ............................................................................................. 7 APPLICABLE STANDARD.............................................................................................................................................. 7 MEASUREMENT UNCERTAINTY................................................................................................................................... 7 EUT SETUP................................................................................................................................................................. 7 EMI TEST RECEIVER SETUP........................................................................................................................................ 8 TEST EQUIPMENT LIST AND DETAILS.......................................................................................................................... 8 TEST PROCEDURE........................................................................................................................................................ 8 TEST RESULTS SUMMARY........................................................................................................................................... 8 TEST DATA.................................................................................................................................................................. 9 FCC §18.305 – FIELD STRENGTH ......................................................................................................................... 11 MEASUREMENT UNCERTAINTY................................................................................................................................. 11 EUT SETUP............................................................................................................................................................... 11 EMI TEST RECEIVER SETUP...................................................................................................................................... 12 TEST EQUIPMENT LIST AND DETAILS........................................................................................................................ 12 TEST PROCEDURE...................................................................................................................................................... 12 CORRECTED AMPLITUDE CALCULATION................................................................................................................... 12 T…
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS AC Line Conduction Emissions – Front View AC Line Conduction Emissions – Side View Radiated Emissions View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.04 MHz - 0.05 MHz | - |

CFL
Equipment Class
8CC - Part 18 Consumer DeviceEquipment Class
8CC - Part 18 Consumer Device
Equipment Class
8CC - Part 18 Consumer Device
CFL
Equipment Class
8CC - Part 18 Consumer Device
CFL
Equipment Class
8CC - Part 18 Consumer Device