VTJS10621Lone Worker Protection Device

SoloProtect Limited
Lone Worker Protection Device - FCC ID VTJS10621 - SoloProtect Limited
Click to zoom

Application Details

Equipment Class
PCT - PCS Licensed Transmitter worn on body
Date of Grant
Oct 19, 2011
Application Purpose
Original Equipment
Date of Application
Oct 13, 2011
Equipment Note
Lone Worker Protection Device
Frequency Range
1850.20000000 - 1909.80000000
Company
SoloProtect Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Preface 09/11 page i i-Series and t-Series User Guide Sept 2011 Revision 1.5a This manual applies to Identicom models i750, i770, i757 and i777, with software versions V5.2.13 or later, and models t757 and t777 with software versions V5.2.13t or later. Preface 09/11 page ii  September 2011 Connexion 2 Ltd Unit 5 Carrera Court Church Lane Dinnington Sheffield S25 2RG England Email: [email protected] Website: www.connexion2.com Printed in England September 2011 Preface 09/11 page iii About Identicom Identicom is a communication device disguised as an ID card holder. It enables vulnerable solitary workers to communicate discreetly with their back-up services in potentially hazardous situations. About this guide This user guide provides all the information you need to set up, operate and take care of your Identicom. A Technical Reference Manual is available from Connexion2 (please email [email protected] ) which provides configuration information for the people who deploy and manage the system, and run the back-up services. Preface 09/11 page iv Identicom Limited Warranty Thank you for buying this Connexion2 product. Please read this user manual before attempting to use it. To avoid damaging the Identicom, do not: o Expose it to extremes of temperature or humidity; o Subject it to hard knocks or excessive force; o Immerse it in liquid; or o Use volatile or corrosive substances when cleaning it, as damage caused in any of these ways is not covered by this warranty. If you have any difficulty using your Identicom, consult the user manual to check you are using it correctly. If within 12 months of the date of purchase this Identicom does not function substantially as described in the user manual because of defective materials or workmanship, Connexion2 Limited will repair it free of charge, subject to the following conditions: Where the fault is the result of misuse, unusual external effects, accidental damage, normal wear and tear, or unauthorised repair, Connexion2 Limited may charge you for the repair and retain this Connexion2 product until you have paid that charge in full. You must produce proof of purchase, showing the date of purchase of this Connexion2 product, to have a repair carried out free of charge under this warranty, so please keep your receipt/invoice safely. To have this Connexion2 product repaired under this warranty, you first need to contact Connexion2 via email for a Problem ID Number (Returns Number). Either return it personally or send it by registered post/Courier, together with your Problem ID Number, sales receipt, to your Connexion2 supplier or to Connexion2 Ltd, at the address shown in this user manual. Please ensure that it is properly and securely packed. Please note that we will not be liable for damage to or loss of this Connexion2 product while it is in transit to Connexion2 or a Connexion2 supplier; check that your Preface 09/11 page v insurance covers the relevant risks. Service is only available in countries where Connexion2 Limited officially distributes the product. In the event of Connexion2 being unable to correct or replace the Identicom, Connexion2’s liability to you shall not exceed the purchase price of the Identicom. In no event will Connexion2 be liable for direct, indirect, special, incidental or consequential loss of profits or loss of data arising out of use or misuse of the Identicom. Nothing in this warranty shall limit or restrict Connexion2’s liability for death or personal injury caused by its negligence. Preface 09/11 page vi Contents 1 Introduction ...................................................................................... 1 2 Initial Setup ....................................................................................... 3 Installing the lanyard or lapel clip .................................................. 4 Inserting the SIM card .................................................................... 5 Inserting your ID card ..................................................................... 7 Charging ......................................................................................... 7 Switching the device on and off ..................................................... 8 Care and maintenance ................................................................... 8 3 Status Checking ................................................................................ 9 Battery and signal status checking ............................................... 10 Ending the status display ............................................................. 10 SIM card faults ............................................................................. 11 Red and Amber Alert status ......................................................... 11 4 Amber Alerts ................................................................................... 12 Starting an Amber Alert ............................................................... 12 Options when in an Amber Alert timer period ............................ 13 5 Red Alerts ....................................................................................... 14 Starting a Red Alert ...................................................................... 14 Voice call connection confirmation .............................................. 16 Heartbeat pulse ............................................................................ 16 Rip Alarm Alerts ........................................................................... 17 Man Down Red Alerts (models i770, i777 and t777 only) ........... 17 Clearing a Red Alert ...................................................................... 19 6 GPS Operation (i757 and i777 only) ............................................... 20 7 GPS Operation (t757 and t777 only) .............................................. 21 8 Identicom Indicators....................................................................... 22 LED indications .................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Cinlerion Wireless Modules GmbH· Siemensdamm 50 • 13629 Berlin • Germany RFI Global Services Ud. Name Thorsten Liebig Pavilion A Department Manager Approval Ashwood Park Basingstoke Phone +493031102-8241 Hampshire Fax +493031102-8305 RG238BG E-Mail [email protected] United Kingdom Your letter of Our reference Date 21 January 2011 Confidentiality Request; Certification Application FCCID: VT JS10621 Dear Sir or Madam, Pursuant to Sections 0.457 and 0.459 of CFR 47 Cinterion Wireless Modules request that the following information, provided to support the FCC application for equipment S1 0621, FCCID: VT JS1 0621 be held permanently confidential on behalf of Connexion2 Ud: Schematic MC55i schematic/1 Number of pages per file 7 Blockdigram MC55Lblockdiagram/1 Number of pages per file 1 Operational Description MC55i HID/1 Number of pages per file 97 Parts list MC55LPartslist/1 Number of pages per file 4 Tune up MC55LTune_up/1 Number of pages per file 1 The above malerial eonlains Irade seereis nol euslomarily released 10 publie Ihal are judged 10 have Ihe polenlial 10 eause delrimenl 10 Ihe applieanl and provide unjuslified benefils 10 ils eompelilors. This information should nol be available for pub/ie disc/osure for an indefinile period of lime. Yours sincerely n~Lf ci4 ~u Thorsten liebig Regislered office : M anagin g direclors: Commercial regis ler, Reg . no.: Cinlerion Wireless Modules GmbH Norbert Muhrer. Bolla Hubner Amisgericht Munchen, HRB 172715 SI. -Martin-S lraße 53 WEEE-Reg .-Nr OE 58893809 81 669 München Ge rmany

Cover Letter(s)

Cinterion Wire!ess Modules GmbH· Siemensdamm 50 • 13629 Bertin • Germany RFI Global Services Ud. Name Thorsten Liebig Pavilion A Department Manager Approval Ashwood Park Basingstoke Phone +493031102-8241 Hampshire Fax +493031102-8305 RG238BG E-Mail [email protected] United Kingdom Your letter of Our reference Date 19 January 2011 Authority to use FCC exhibits supplied for FCCID: VTJS1 0621 Dear Sir or Madam, We, Cinterion Wireless Modules GmbH, St. Martin Str. 53; 81669 München hereby authorise Connextion2 Ud to use our exhibits used for FCC liD: QIPMC55i in support of tneir application reference FCC ID: VTJS1 0621, for which HFI Global Services, Pavilion A, Ashwood Park, Ashwood Way, Basingstoke, Hampshire, RG23 8BG, UK is the appointed TCB. Yours sincerely TJ~~k~1 ~~ 10 Thorsten Liebig Registered office: Managing directors: Commercial register, Reg. no.: Cinterton W ireless Modules GmbH Norbert Muhrer, Brilta Hübner Amtsgericht München, HRB 172715 SI.·Martin ·Slraße 53 WEEE·Reg.·Nr. OE 58893809 81669 Müncl1en Germany

Internal Photos

Top Side PCA GPS Module Mounting Screening Can Removed to Show Battery Bottom Side PCA showing Processor Top Side showing ECN0012 Modification

RF Exposure Info

TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Connexion2 Ltd, Identicom t777 To: OET Bulletin 65 Supplement C: (2001-01) RSS-102 Issue 4 March 2010 Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 supersedes all previous versions This Test Report Is Issued Under The Authority Of Chris Guy, Head of Global Approvals: (APPROVED SIGNATORY) Checked By: Richelieu Quoi (APPROVED SIGNATORY) Issue Date: 04 October 2011 Test Dates: 11 April 2011 This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested. Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 2 of 47 RFI Global Services Ltd. This page has been left intentionally blank. Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 3 of 47 RFI Global Services Ltd. TABLE OF CONTENTS 1. Customer Information ...................................................................................................... 4 2. Equipment Under Test (EUT) ........................................................................................... 5 3. Test Specification, Methods and Procedures ................................................................ 7 4. Deviations from the Test Specification ........................................................................... 8 5. Operation and Configuration of the EUT during Testing .............................................. 9 6. Summary of Test Results ............................................................................................... 10 7. Measurements, Examinations and Derived Results .................................................... 11 8. Measurement Uncertainty .............................................................................................. 15 Appendix 1. Test Equipment Used .................................................................................... 18 Appendix 2. Measurement Methods .................................................................................. 21 Appendix 3. SAR Distribution Scans ................................................................................ 23 Appendix 4. Photographs .................................................................................................. 34 Appendix 5. Validation of System ..................................................................................... 43 Appendix 6. Simulated Tissues ......................................................................................... 44 Appendix 7. DASY4 System Details .................................................................................. 45 Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 4 of 47 RFI Global Services Ltd. 1. Customer Information Company Name: Connexion2 Ltd Address: Momentum House Church Lane Dinnington Yorkshire S25 2RG Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 5 of 47 RFI Global Services Ltd. 2. Equipment Under Test (EUT) 2.1. Identification of Equipment Under Test (EUT) Description: Identicom t series Lone Worker Device Brand Name: t series Model Name or Number: T series S10619 Serial Number: S10619007448 IMEI Number: 35368 1048037390 Hardware Version Number: EE09-TR1-BOM-2-007 Software Version Number: EE09-05-02-t13 Hardware Revision of GSM Module: Not Applicable Software Revision of GSM Module: Not Applicable FCC ID Number: VTJS10621 IC ID Number: 7467A-S10621 Country of Manufacture: UK Date of Receipt: 08 April 2011 2.2. Description of EUT The Equipment Under Test is a communication device disguised as an ID card holder for Lone Worker. The EUT operates at GSM850 / PCS1900 frequency bands and it has GPRS Class 10 capabilities. 2.3. Modifications Incorporated in the EUT EUT was modified in order to answer GSM calls using ‘ATA’ commands. 2.4. Support Equipment The following support equipment was used to exercise the EUT during testing: Description: Wireless Communication Test Set Brand Name: Agilent Model Name or Number: 8960 Series 10 Serial Number: GB46311280 Cable Length and Type: ~4.0 m Utiflex RF cable Connected to Port: RF (Input/Output) Air Link Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 6 of 47 RFI Global Services Ltd. 2.5. Additional Information Related to Testing Equipment Category GSM850 / PCS1900 Type of Unit Portable Transceiver Intended Operating Environment: Within GSM coverage Transmitter Maximum Output Power Characteristics: GSM850 Communication Test Set was configured to allow the EUT to transmit at a maximum power of up to 33dBm. PCS1900 Communication Test Set was configured to allow the EUT to transmit at a maximum power of up to 30dBm. Transmitter Frequency Range: GSM850 (824 to 849) MHz PCS1900 (1850 to 1910) MHz Transmitter Frequency Allocation of EUT When Under Test: Channel Number Channel Description Frequency (MHz) 128 Low 824.2 189 Middle 836.4 251 High 848.8 512 Low 1850.2 660 Middle 1879.8 810 High 1909.8 Modulation(s): GMSK (GSM): 217 HZ Modulation Scheme (Crest Factor): GMSK (GSM): 8.3 Antenna Type: Internal Antenna Length: Unknown Number of Antenna Positions: 1 Fixed Power Supply Requirement: 3.7 V Battery Type(s): Li-Ion Test Report Serial No: RFI-SAR-RP81383JD01A V4.0 Version 4.0 Issue Date: 04 October 2011 Page: 7 of 47 RFI Global Services Ltd. 3. Test Specification, Methods and Procedures 3.1. Test Specification Reference: OET Bulletin 65 Supplement C: (2001-01) Title: Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Ele…

Text truncated - open the document above for the full version.

Test Report

The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written approval of the testing laboratory © Copyright ■ All rights reserved by CETECOM Applicant: Siemens AG Laboratory Accreditation and Listings DAT-P-176/94-02 Federal Communications Commission FCC Registration No. 99538 MRA US-EU DE0003 Industry Canada IC Registration No. IC 3465 accredited according to DIN EN ISO/IEC 17025 CETECOM GmbH Laboratory RC & EMC Im Teelbruch 116 D-45219 Essen Germany Telephone: + 49 (0) 20 54 / 95 19-954 Fax: + 49 (0) 20 54 / 95 19-964 for GSM/GPRS Module MC55i FCC Part 22/24 & RSS 132, Issue 2 RSS 133, Issue 3 T E S T R E P O R T No.: 2-20722858c/07-C1 EMC Test Report 2-20722858c/07-C1, Page 2 of 139 B_2_20722858c_07-C1.doc Table of contents 1. SUMMARY OF TEST RESULTS 3 1.1. TESTS OVERVIEW 3 2. ADMINISTRATIVE DATA 5 2.1. Identification of the testing laboratory 5 2.2. Test location 5 2.3. Organizational items 5 2.4. Applicant’s details 5 2.5. Manufacturer’s details 5 3. EQUIPMENT UNDER TEST (EUT) 6 3.1. Additional declaration and description of main EUT 6 3.2. EUT: Type, S/N etc. and short descriptions used in this test report 6 3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions 7 3.4. EUT set-ups 7 3.5. EUT operating modes 8 3.6. Additional declaration and description of EUT’s 9 3.7. Configuration of cables used for testing 9 4. MEASUREMENTS SET-UPS 10 4.1. Conducted measurements test set-up 10 4.2. Radiated measurements test set-up 11 4.3. Parameter Settings on mobile phone and base station CMU200 12 5. MEASUREMENTS AND TEST RESULTS 13 5.1. RF power output (Conducted and Radiated) 13 5.2. Occupied 99% bandwidth 16 5.3. Emission limits radiated (Spurious emission radiated) f< 30 MHz 18 5.4. Emission limits (Spurious emission) f> 30 MHz 20 5.5. Frequency stability on temperature and voltage variations 28 6. MEASUREMENT UNCERTAINTIES 37 7. CALIBRATION METHOD OF ANECHOIC CHAMBER 38 8. INSTRUMENTS AND ANCILLARY 39 8.1. Used equipment “CTC” 39 9. ANNEX 1: DIAGRAMS OF THE MEASUREMENTS 43 9.1. EMISSION BANDWIDTH 43 9.2. OCCUPIED 99% BANDWIDTH 49 9.3. SPURIOUS EMISSIONS CONDUCTED 55 9.4. RADIATED SPURIOUS EMISSIONS 81 9.5. MAGNETIC FIELD STRENGTH MEASUREMENTS (RADIATED) 131 9.6. IC : CONDUCTED MEASUREMENTS IN RX-MODE 850MHZ, RSS-132-ISSUE 2, CHAPTER 4.6 137 9.7. IC: CONDUCTED MEASUREMENTS IN RX-MODE 1900 MODE: RSS-133-ISSUE 3, CHAPTER 6.7(B) 138 10. ANNEX A - PHOTOS: EUT AND ACCESSORIES 139 11. ANNEX B - PHOTOS: TEST SET-UP 139 EMC Test Report 2-20722858c/07-C1, Page 3 of 139 B_2_20722858c_07-C1.doc 1. Summary of test results The test results apply exclusively to the test samples as presented in chapter 3.1. The CETECOM GmbH does not assume responsibility for any conclusions and generalisations taken in conjunction with other specimens or samples of the type of the item presented to tests. The presented GSM 850/900/1800/1900 Module can be build inside host applications and extends their capability by wireless GSM technology. Data transmission or voice application are possible field applications. In order to verify the compliance, a representative configuration consisting of different auxiliary equipment was chosen. Embedded in this configuration, the GSM/GPRS Module can be tested. Following tests have been performed to show compliance with applicable standards: FCC Part 2, Part 22 and Part 24, Subpart E (Broadband PCS) of the FCC CFR 47 Rules and RSS-132 and RS- 133 IC rules. ATTESTATION: I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct to my best knowledge and belief to Industry Canada standards. All requirements as shown in below table are met in accordance with enumerated standards. 1.1. TESTS OVERVIEW TEST CASES PORT REFERENCES & LIMITS EUT set-up EUT opera- Result FCC StandardRSS Section TEST LIMIT ting mode TX-Mode RF POWER (conducted) Antenna terminal (conducted) §2.1046 -- N/A 1 2+4 Passed RF-POWER radiated (ERP/EIRP) Cabinet §2.1046 §22.913(a)(2) §24.232(c) RSS-132: 4.4 SRSP-503: 5.1.3 RSS-133:6.4 SRSP-510: 5.1.2 < 7 Watt ERP < 2 Watt (EIRP) 1 2+4 Passed SPURIOUS EMISSIONS (conducted) Antenna terminal (conducted) §2.1051 §22.917(a)(b) §24.238(a)(b) RSS 132: 4.5.1 RSS 133: 6.5.1 43+10log(P) dBc 1 2+4 Passed 99% OCCUPIED BANDWIDTH Antenna terminal (conducted) §2.202 §2.1049 §22.917(a) §24.238(a) RSS Gen:4.6.1 99% Power 1 2+4 Passed EMC Test Report 2-20722858c/07-C1, Page 5 of 139 B_2_20722858c_07-C1.doc 2. Administrative Data 2.1. Identification of the testing laboratory Company name: CETECOM GmbH Address: Im Teelbruch 116 45219 Essen – Kettwig, Germany Laboratory accreditations/Listings: DAR-Registration No. DAT-P-176/94-02 FCC-Registration No. 99538 MRA US-EU DE0003 IC-Registration No. 3465 Responsible for testing laboratory: Dipl.-Ing. W. Richter Deputies: Dipl.-Ing. H. Strehlow, D. Franke 2.2. Test location 2.2.1. Test laboratory “CTC” Company name: see chapter 2.1. Identification of the testing laboratory . 2.3. Organizational items Order No.: 20722858 Responsible for test report and project leader: Dipl.-Ing. C. Lorenz Receipt of EUT: 20.11.2007 Date(s) of test: 21.11.2007 – 07.12.2007 Date of report: 03.01.2008 Number of report pages: 139 --------------------------------------------------------------------------------------------------------------------------------------- Version of template: 07.11 2.4. Applicant’s details Applicant’s name: Siemens AG Address: ICM WM RD ST3 Siemensdamm 50 13623 Berlin Germany Contact person: Mr. Thorsten Liebig 2.5. Manufacturer’s details Manufacturer’s name: please see Applicant's details Address: please see Applicant's details EMC Test Report 2-20722858c/07-C1, Page 6 of 139 B_2_20722858c_07-C1.doc 3. Equipment under test (EUT) 3.1. Additional declaration and description of main EUT Main function GSM/GPRS Module Type MC55i GSM Frequency range GSM850: 824 - 849MHz (Uplink), 8…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Connexion2 Ltd, Identicom t777 To: 47CFR15.107 and 47CFR15.109 Test Report Serial No: RFI-EMC-RP76894JD02A V2.0 Version 2.0 supersedes all previous versions This test report is issued under the authority of Chris Guy, Head of Global Approvals: Checked By: Andy Graham Signature: Date of Issue: 14 September 2011 This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested. TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 Page 2 of 33 RFI Global Services Ltd. This page has been left intentionally blank. TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 RFI Global Services Ltd. Page 3 of 33 TABLE OF CONTENTS 1. Customer Details .............................................................................................................. 5 2. Summary of Testing ......................................................................................................... 6 3. Equipment under Test (EUT) ........................................................................................... 7 4. Support Equipment ........................................................................................................... 9 5. Monitoring Performance ................................................................................................ 10 6. Measurement Uncertainty .............................................................................................. 11 7. Measurements, Examinations and Derived Results .................................................... 12 8. Photographs of EUT ....................................................................................................... 19 9. Graphical Test Results ................................................................................................... 22 10. Test Configuration Drawing ......................................................................................... 32 TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 Page 4 of 33 RFI Global Services Ltd. This page has been intentionally left blank. TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 RFI Global Services Ltd. Page 5 of 33 1. CUSTOMER DETAILS Company Name: Connexion2 Ltd Address: Momentum House Church Lane Dinnington Yorkshire S25 2RG United Kingdom TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 Page 6 of 33 RFI Global Services Ltd. 2. SUMMARY OF TESTING 2.1. Test Specification Reference: 47CFR15.107 and 47CFR15.109 Title: Code of Federal Regulations Volume 47 (Telecommunications) 2010: Part 15 Subpart B (Radio Frequency Devices) – Sections 15.107 and 15.109. Site Reference: 209735 2.2. Summary of Test Results Clause Measurement Type Applicability Result 15.109 Radiated Emissions (Enclosure) Y 15.107 Conducted Emissions (AC Mains Input / Output Ports) Y KEY: = Complied = Did not comply 2.3. Location of Testing All the measurements described in this report were performed at the premises of RFI Global Services Ltd, Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, Hampshire RG24 8AH. 2.4. Deviations from the Test Specification For the measurements contained within this test report, there were no deviations from, additions to, or exclusions from the test specification identified above, nor from the requirements defined in the basic standards called up within it. TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 RFI Global Services Ltd. Page 7 of 33 3. EQUIPMENT UNDER TEST (EUT) 3.1. Description of EUT The EUT was a GSM enabled lone worker security device complete with a man-down alarm and an in-built GPS receiver. 3.2. Identification of Equipment under Test (EUT) ID# Description Brand Name Model No Serial No IMEI E1 Lone worker device Connection2 Ltd Identicom t777 S10619002814 352024029230880 E2 AC/DC Adaptor None Stated SCP0750300P None Stated Not Applicable 3.3. Port Identification Port Description Type P1 Enclosure - P2 Charger Socket DC Socket 3.4. Operating Modes Mode Reference Definition Idle The EUT was synchronised with a radio communication tester but not allocated a channel in the operating bands; GSN 850 and PCS 1900 NOTE: It was not possible to have the EUT synchronised with the radio communication tester when connected to the AC mains supply (via the AC/DC adaptor), therefore conducted emissions testing was performed with the EUT in a charging state and not synchronised with the radio communication tester. Radio characteristics GSM Bands tested: Rated Output Power (dBm) Transmit Frequency range (MHz) ARFCN Transmit Frequency (MHz) Receive Frequency range (MHz) ARFCN Receive Frequency (MHz) GSM 850 33 824 – 849 190 836.6 869 – 894 190 881.6 PCS 1900 30 1850 – 1910 660 1879.8 1930 – 1990 660 1959.8 Supported Technologies e.g. Circuit Switched Voice/Data, Packet Switched Data GPRS/ EDGE Circuit Switched Voice/Data 3.5. Configuration and Peripherals Description: Please refer to the Test Configuration and Photograph section for schematic drawing(s) and/or photograph(s) of the test configuration(s) employed in the course of testing. 3.6. Modifications NOTE: No modifications were made to the EUT during the course of testing. TEST REPORT SERIAL NO: RFI-EMC-RP76894JD02A V2.0 VERSION: 2.0 ISSUE DATE: 14 SEPTEMBER 2011 Page 8 of 33 RFI Global Services Ltd. 3.7. Additional Information Related to Testing Equipment Category: GSM Intended Operating Environme…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Identicom T Series Lone Worker Device FCC ID: VTJS10621 IC Certification No.: 7467A-S10621 To: FCC Parts 22.913 & 24.232; Industry Canada RSS-132 Issue 2 Section 4.4 & RSS-133 Issue 5 Section 6.4 Test Report Serial No: RFI-RPT-RP82075JD01A V3.0 Version 3.0 Supersedes All Previous Versions This Test Report Is Issued Under The Authority Of Chris Guy, Head of Global Approvals: Checked By: Ian Watch Signature: Date of Issue: 19 August 2011 This report is issued in Adobe Acrobat portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, Adding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested. TEST REPORT SERIAL NO: RFI-RPT-RP82075JD01A V3.0 VERSION 3.0 ISSUE DATE: 19 AUGUST 2011 Page 2 of 17 RFI Global Services Ltd This page has been left intentionally blank. TEST REPORT SERIAL NO: RFI-RPT-RP82075JD01A V3.0 VERSION 3.0 ISSUE DATE: 19 AUGUST 2011 RFI Global Services Ltd Page 3 of 17 Table of Contents 1. Customer Information .................................................................................................................. 4 2. Summary of Testing ..................................................................................................................... 5 2.1. General Information 5 2.2. Summary of Test Results 6 2.3. Methods and Procedures 6 2.4. Deviations from the Test Specification 6 3. Equipment Under Test (EUT) ....................................................................................................... 7 3.1. Identification of Equipment Under Test (EUT) 7 3.2. Description of EUT 7 3.3. Modifications Incorporated in the EUT 7 3.4. Additional Information Related to Testing 8 3.5. Support Equipment 8 4. Operation and Monitoring of the EUT during Testing ............................................................... 9 4.1. Operating Modes 9 4.2. Configuration and Peripherals 9 5. Measurements, Examinations and Derived Results ................................................................ 10 5.1. General Comments 10 5.2. Test Results – Part 22 & RSS-132 11 5.2.1. Transmitter Effective Radiated Power (ERP) 11 5.2.2. Transmitter Conducted Average and Peak Output Power 13 5.3. Test Results – Part 24 & RSS-133 14 5.3.1. Transmitter Equivalent Isotropic Radiated Power (EIRP) 14 5.3.2. Transmitter Conducted Average and Peak Output Power 15 6. Measurement Uncertainty .......................................................................................................... 16 Appendix 1. Test Equipment Used ................................................................................................ 17 TEST REPORT SERIAL NO: RFI-RPT-RP82075JD01A V3.0 VERSION 3.0 ISSUE DATE: 19 AUGUST 2011 Page 4 of 17 RFI Global Services Ltd 1. Customer Information Company Name: Connexion2 Ltd. Address: Momentum House Church Lane Dinnington Yorkshire S25 2RG United Kingdom TEST REPORT SERIAL NO: RFI-RPT-RP82075JD01A V3.0 VERSIO…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Wangsmo(Managing Director)
[email protected]+17132024780Fax: +441909550888

Technical Contact

Triteq LtdSteve Lane
[email protected]44 1488 684554

The Innovation Centre, Station Yard · Hungerford · United Kingdom

Non-Technical Contact

Connexion2 LimitedMarc Appleton
[email protected]44 0844 8566606

Test Firm

UL VS LtdDarren Rust
[email protected]+44 1256 31 2119Fax: +44 1256 31 2001

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz500.00 mW300KGXW1 ppm
Confidentiality
Long Term
Grant Notes
This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. Power output is ERP for Part 22 and EIRP for Part 24. This device has been tested and meets the FCC RF exposure guidelines for body worn operation when used with the accessories supplied or designated for this product. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for the device is body worn 1.43W/kg.

Other Applications from SoloProtect Limited

Brama L V2 - FCC ID VTJ-BRAMALV2 - SoloProtect Limited
VTJ-BRAMALV2

Brama L V2

Jan 17, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
IDENTICOM i700 - FCC ID VTJS10611 - SoloProtect Limited
VTJS10611

IDENTICOM i700

Mar 26, 2008

Equipment Class

PCT - PCS Licensed Transmitter worn on body