FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. KONICA MINOLTA, INC./
  3. VTLCM600D

VTLCM600DSpectrophotometer

KONICA MINOLTA, INC.
Spectrophotometer - FCC ID VTLCM600D - KONICA MINOLTA, INC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 21, 2012
Application Purpose
Original Equipment
Date of Application
Mar 21, 2012
Equipment Note
Spectrophotometer
Frequency Range
2402.00000000 - 2480.00000000
Company
KONICA MINOLTA, INC.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗
↗

Internal Photos

↗
↗

Parts List/Tune Up Info

↗
↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

DATE March 8 2012 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Differences between the CM-600d and CM-700d Is the same basic features and performance. The only difference as fixed measurement area model and switched measurement area model Takayoshi Nishii

Parts List/Tune Up Info

87   2 4 4 ST01 AHD 13.5 3.0 3.0 AHD1403-244ST t=0.8 AHD1403-191ST t=0.8 AHD1103-244ST t=0.8 1.00.252.01.0 AHD1403 Series T T 10.5 1.00.252.01.0 AHD1103 Series Surface mountable dielectric chip antennas AHD series is a result of harmon- izing our long experience in ceramic material & process technologies for high frequency applications together with cutting-edge RF design technologies. It is very small with low profile, but has a wide range of frequency band. It is suitable for compact mobile equipment and communication modules. ●Very small and thin, omni-directional antenna. ●Due to its compact size, suitable for equipment like cellular phone with a lim- ited mounting space. ●Suitable for card shaped equipment due to its low profile. ●Wide frequency band allows a big margin to cover the required range even in case of center frequency shift with mounting condition and other environ- mental factors. Center Frequency Option SizeSeries1GHz100MHz10MHzControl Code Part number system ■Features ■Applications Part number list Operating Temperature 25 8524002484MHz13.530.8mm AHD1403-244ST01 Linear 25 8524002484MHz10.530.8mm AHD1103-244ST01 Linear 25 8518801920MHz13.530.8mm AHD1403-191ST01 Linear PolarizationOperating Frequency RangeSizesPart Number Characteristics (Reference) Dimensions Average GainPeak GainBandwidth in VSWR3 0.5dBd230MHzAHD1403-244ST01 1.3dBd 130MHzAHD1403-191ST01 1.0dBd 200MHzAHD1103-244ST01 Part Number Packing form Taping Bulk Unit : mmUnit : mm 1403 88   In case of surface mount antennas, the center frequency is dependent on the PCB size or other surrounding components and materials, and therefore can be different from what is measured with our standard test board. For the AHD series , we have therefore prepared series of items having different center fre- quencies with a certain frequency step, in order to cancel the above men- tioned frequency shift by the environmental factors. So with our AHD series, you can easily and quickly find the most suitable an- tenna for your own mounting conditions. ■Series of center Frequencies Characteristics of AHD1103-244ST01 Characteristics of AHD1403-244ST01 Characteristics of AHD1403-191ST01 0 90

Parts List/Tune Up Info

SP- 0018 Model ModelModelModel Component Name Parts No. Manufacturer Type Name Location Frequencies Rating Oscillator A0E8-6906 Epson Toyocom Corporation SG-8002JF-6MHz-PCC on CPU P.C.B 6MHz Oscillator A0E8-6907 Epson Toyocom Corporation SG-8002JF-48MHz-PCC on CPU P.C.B 48MHz Oscillator 1898-6916 Epson Toyocom Corporation Q13MC2061000414 on CPU P.C.B 32.768kHz DC/DC Converter A0E8-4502 Linear Technology Corporation LTC1627CS8#PBF on Power Supply P.C.B 350kHz DC/DC Converter A0E8-4502 Linear Technology Corporation LTC1627CS8#PBF on Power Supply P.C.B 350kHz DC/DC Converter A0E8-4503 Linear Technology Corporation LT1317CS8#PBF on Power Supply P.C.B 600kHz DC/DC Converter 1877-4510 Linear Technology Corporation LT1308ACS8#PBF on Power Supply P.C.B 600kHz DC/DC Converter 1856-4501 Linear Technology Corporation LT1110CS8#PBF on Power Supply P.C.B 70kHz ADC A0E8-4603 Analog Devices,Inc. AD7655ASTZ on CPU P.C.B Coil 1892-6004 Murata Manufacturing Company,Ltd. DLP31SN551SL2 on Power Supply P.C.B 16V,100mA,550Ωat100MHz Ferrite Bead A0E8-6011 Murata Manufacturing Company,Ltd. BLM41PG750SN1 on Power Supply P.C.B 3000mA,75Ωat100MHz Spread Spectrum A0E8-4704 Integrated Device Technology,Inc., MK5811ASLF on CPU P.C.B Ferrite Bead A0E8-6012 Murata Manufacturing Company,Ltd. BLM18SG331TN1 on CPU P.C.B 1500mA,330Ωat100MHz Ferrite Bead A0E8-6013 Murata Manufacturing Company,Ltd. BLM15BB750SN1 on CPU P.C.B 300mA,75Ωat00MHz Ferrite Bead A0E8-6008 Murata Manufacturing Company,Ltd. BLM21AG102SN1 on BT P.C.B 200mA,1kΩat100MHz Coil A0E8-6009 Murata Manufacturing Company,Ltd. LQG18HN3N9S00 on BT P.C.B 450mA,3.9nHat100MHz Sheet A0E8-6905 NEC TOKIN Corporation R4N(10) UL94-0,E176124 SPECTROPHOTOMETER CM-700d/CM-600d SPECTROPHOTOMETER CM-700d/CM-600dSPECTROPHOTOMETER CM-700d/CM-600dSPECTROPHOTOMETER CM-700d/CM-600d Constructional Data List Constructional Data ListConstructional Data ListConstructional Data List コニカミノルタセンシング(株)

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 9 7-01 Equipment CM-700d Manufacturer KONICA MINOLTA SENSING, INC. where: S = power density P = power input to the antennaG = power gain of the antenna in the direction of i nterest relative to an isotropic radiator R = distance to the center of radiation of the ante nna Maximum peak output power at antenna input terminal : 11.96 Maximum peak output power at antenna input terminal : 15.70362804 Antenna gain(typical): 1.65 Maximum antenna gain: 1.462177174 (numeric) Prediction distance: 20 (cm) Prediction frequency: 2440 (MHz) MPE limit for uncontrolled exposure at prediction f requency: 1 Power density at prediction frequency: 0.004568 Maximum allowable antenna gain: 25.05269855 Margin of Compliance: 23.40269855 (dBm)(mW)(dBi)(mW/cm^2)(mW/cm^2)(dBi) 2 4 R PG S π =

Test Report

Page1of54 Test Report No. R1059941 Rev.01 CosmosCorporation CosmosCorporationCosmosCorporation CosmosCorporation35712OhnokiWataraichoWataraigunMieken5162102Japan   Telephone:+81596630707  Facsimile:+81596630777  URL:http://www.safetyweb.co.jp  MEASUREMENT MEASUREMENTMEASUREMENT MEASUREMENT  / // /  TECHNICALREPORT TECHNICALREPORTTECHNICALREPORT TECHNICALREPORT   FCCPart15 FCCPart15FCCPart15 FCCPart15SubpartC SubpartCSubpartC SubpartC   Issued: January13,2012  NameandAddress KONICAMINOLTASENSING,INC.  oftheApplicant:391,Daisennishimachi,Sakaiku,Sakai,Osaka 5908551,Japan   TestItem: Spectrophotometer   Identification:CM700d  SerialNo.:01  SampleNo.:1  FCCID:VTLCM700d  SampleReceiptDate:November22,2011  TestSpecification:FCCPart15SubpartC,15.247  DateofTesting:November24,28and29,2011 December2,3,5and7,2011   TestResult:PASS   ReportPreparedby: CosmosCorporation   35712Ohnoki,Wataraicho,Wataraigun,Mie,Japan5162102   Phone:+81596630707Fax:+81596630777      Testedby:  (O.Itogawa,EMCDept.EMCEngineer)   (20120113)         Reviewedby: (Y.Kawahara,EMCDept.EMCManager)  (20120113) iNARTE:EMC002846NE   Notes:  1. This Test Report should not be reproduced except in full, without the written approval of Cosmos Corporation. 2. AllmeasurementdatacontainedinthisTestReportmayhaveuncertainty.Ajudgmentforthelimitation shouldbetakenintothecount.  3. ThetestresultofthisTestReportisbasedonthetestsmadeforsampleprovided,anditisnotapplicableto individualproductidenticaltothesampleorsimilarproduct.  Page2of54 Test Report No. R1059941 Rev.01 CosmosCorporation CosmosCorporationCosmosCorporation CosmosCorporation35712OhnokiWataraichoWataraigunMieken5162102Japan   Telephone:+81596630707  Facsimile:+81596630777  URL:http://www.safetyweb.co.jp  RevisionHistory RevisionHistoryRevisionHistory RevisionHistory         Revision RevisionRevision Revision  IssueDate IssueDateIssueDate IssueDate  Description DescriptionDescription Description   Effect EffectEffect Effect Page PagePage Page   Revised RevisedRevised Revised By ByBy By   00 December27,2011InitialIssue         01January13,2012 ・Change of description for modulation method ・AdditionalofcalculationformulaofTime ofOccupancy ・DeletionofSpectrumBandwidthof DirectSequenceSpreadSpectrumSystem ・Change of limit of Maximum Peak OutputPower ・DeletionofMinimumStandardin MaximumPeakOutputPower ・DeletionofPowerSpectrumDensity ・AdditionalofscreenshotofBandEdge Measurement Page5, 7,14, 15,18, 19,20, 21,23, 26,41 and42  Yoshida    Page3of54 Test Report No. R1059941 Rev.01 CosmosCorporation CosmosCorporationCosmosCorporation CosmosCorporation35712OhnokiWataraichoWataraigunMieken5162102Japan   Telephone:+81596630707  Facsimile:+81596630777  URL:http://www.safetyweb.co.jp List ListList ListofContents ofContentsofContents ofContents                                       Page PagePage Page    1.DescriptionofEquipmentunderTest................................................................................................. 5 1.1 ProductDescription.................................................................................................................... 5 1.2 AntennaDescription .................................................................................................................. 6 2.GeneralInformation............................................................................................................................. 6 2.1 TestMethodology ....................................................................................................................... 6 2.2 TestFacility................................................................................................................................ 6 2.3 Traceability................................................................................................................................. 6 3.SummaryofTestResults..................................................................................................................... 7 4.TestConfiguration................................................................................................................................ 8 4.1 15.207ACPowerConductedEmissioninShieldRoom......................................................... 9 4.2 15.247(d),15.209TransmitterRadiatedEmissions,15.247(d)BandEdge(Radiated)in3m AnechoicChamber ................................................................................................................................ 9 4.3 ConductedEmission................................................................................................................. 10 4.4 TestMode.................................................................................................................................. 10 5.MeasurementResult .......................................................................................................................... 11 5.1 15.207ACPowerConductedEmission.................................................................................. 11 5.1.1 SettingRemarks ............................................................................................................... 11 5.1.2 MinimumStandard ....................................................…

Text truncated - open the document above for the full version.

Test Report

御社レターヘッドを貼付下さい Date: January 13, 2012 FEDERAL COMMUNICATIONS COMMISSION 7435 Oakland Mills Road Columbia, MD 21046 Subject: Declaration for the model differences FCC ID: VTLCM600d and FCC ID: VTLCM600d Dear Sir / Madam: We, KONICA MINOLTA SENSING, INC., hereby declare that the difference between the device FCC ID VTLCM700d, and FCC ID: VTLCM600d is only area which the light irradiates. The enclosure, electronic circuit board, used component, component layout , antenna type and gain which relates to EMC and RF are same. The tests were performed on the device on FCC ID: VTLCM700d , Model No. CM- 700d, and we confirmed the device with FCC ID: VTLCM600d, Model No. CM-600d would comply with the requirement for FCC. Best Regards, ここに署名して下さい Takayoshi Nishii (Mr.), Manger

Test Setup Photos

Page 1 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp S SS Setup Photo etup Photoetup Photo etup Photos ss s ( ( ( (AC Power AC Power AC Power AC Power Conducted Emission) Conducted Emission)Conducted Emission) Conducted Emission) Page 2 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Test Test Test Setup Photo Setup PhotoSetup Photo Setup Photos ss s (Radiated Emission) (Radiated Emission) (Radiated Emission) (Radiated Emission) 30MHz - 1GHz (AC Adaptor) Page 3 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Setup Photos (Radiated Emission) (Continued) 30MHz - 1GHz (Battery) Page 4 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Setup Photos (Radiated Emission) (Continued) 1GHz - 18GHz (AC Adaptor) Page 5 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Setup Photos (Radiated Emission) (Continued) 1GHz - 18GHz (Battery) Page 6 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Setup Photos (Radiated Emission) (Continued) 18GHz - 26.5GHz (AC Adaptor) Page 7 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Setup Photos (Radiated Emission) (Continued) 18GHz - 26.5GHz (Battery) Page 8 of 8 Cosmos Corporation Cosmos Corporation Cosmos Corporation Cosmos Corporation 3571-2 Ohnoki Watarai-cho Watarai-gun Mie-ken 516-2102 Japan Telephone:+81-596-63-0707 Facsimile:+81-596-63-0777 URL: http://www.safetyweb.co.jp Test Test Test Test Setup Photo Setup PhotoSetup Photo Setup Photos ss s ( ( ( (Conducted Emission) Conducted Emission)Conducted Emission) Conducted Emission)

Contact Information

Applicant

Yasuaki Serita
[email protected]81-72-241-3295Fax: 81 72-241-9468

Technical Contact

KONICA MINOLTA SENSING, INCYoshitaka Kato
[email protected]81-72-241-3295

3-91, Dalsennishimachi, Sakai-ku · Sakai · Japan

Test Firm

Cosmos CorporationEiji Asano
[email protected]81-596-37-0190Fax: 81-596-37-3609

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz15.70 mW
Confidentiality
Long Term
Grant Notes
Power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from KONICA MINOLTA, INC.

Bluetooth Spectrophotometer - FCC ID VTLCM-600 - KONICA MINOLTA, INC.
VTLCM-600

Bluetooth Spectrophotometer

Jan 08, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Spectrophotometer - FCC ID VTLCM-700 - KONICA MINOLTA, INC.
VTLCM-700

Bluetooth Spectrophotometer

Jan 08, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter