FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Onsource International Limited/
  3. VVWOS200702

VVWOS200702Ultrasonic Humidifier

Onsource International Limited
Ultrasonic Humidifier - FCC ID VVWOS200702 - Onsource International Limited
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jan 27, 2008
Application Purpose
Original Equipment
Date of Application
Jan 27, 2008
Equipment Note
Ultrasonic Humidifier
Frequency Range
2.40000000 - 2.40000000
Company
Onsource International Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B ISM equipment, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio TV techni - cian for help.

External Photos

External Photo FCC ID : VVWOS200702 External Photo - front External Photo - rear

ID Label/Location Info

Frog-Shape Ultrasonic Humidifier Model No: WA-85 Item No.: A58C0138(547126) 120VAC, 60Hz, 35W HOUSEHOLD USE ONLY Made in China 3098633 CONFORMS TO UL STD. 998 CERTIFIED TO CSA STD. C22.2 NO. 104-01 TM Scale: 30% For Position Only 87mm 109mm CAUTION: DO NOT IMMERSE IN ANY LIQUID READ ALL INSTRUCTIONS BEFORE USE For product Information, Questions, Or Customer Service: Call Toll Free 1-800-645-3867 Or E-mail: [email protected] 5 mm 5 mm Die line 00 Prepared by: 制作人 * Please study and sign back for confi rmation to output. Date:Dec.13.2007 出稿日期 WA-95 Soccer humidifier Dec.13.2007 AR1137 Joey Wu Artwork Release 圖稿發放 Health select FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. Health select FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. Health select FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. 70 mm 25 mm Die line 00 Prepared by: 制作人 * Please study and sign back for confi rmation to output. Date:Dec.13.2007 出稿日期 WA-95 Soccer humidifier Dec.13.2007 AR1137 Joey Wu Artwork Release 圖稿發放 Onsource FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. Onsource FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. source Onsource Int’l Ltd. Frog Humidifier Model: WA-85 120VAC, 60Hz, 35W 3098633 CONFORMS TO UL STD. 998 CERTIFIED TO CSA STD. C22.2 NO. 104-01 Scale: 30% For Position Only 87mm 109mm 5 mm Onsource FCC ID: VVWOS200702 This device complies with Part 18 of the FCC Rules. 70 mm 25 mm

Test Report

• The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. • For Terms And Conditions of the services, it can be provided upon request. • The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2371 0521 Website: www.hk.intertek-etlsemko.com Onsource International Limited Application For Certification (FCC ID: VVWOS200702) Ball Ultrasonic Humidifier 0729665 AL / Connie Lau December 31, 2007 INTERTEK TESTING SERVICES FCC ID: VVWOS200702 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: VVWOS200702 ii MEASUREMENT/TECHNICAL REPORT Onsource International Limited MODEL: Onsource: WA-95, WA-93, WA-94 Health Select: WA-95, WA-93, WA-94 FCC ID: VVWOS200702 December 31, 2007 This report concerns (check one:) Original Grant X Class II Change Equipment Type: Ball Ultrasonic Humidifier Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 18.123? Yes No X If no, assumed Part 18 for Ball Ultrasonic Humidifier - the new 47 CFR Part 18 [10-01-06 Edition] provision. Report prepared by: Chow Chi Ming, Billy Intertek Testing Services Hong Kong Ltd. 2/F., Garment Center, 576, Castle Peak Road, Kowloon, Hong Kong. Phone: 852-2173-8528 Fax: 852-2371-0521 INTERTEK TESTING SERVICES FCC ID: VVWOS200702 iii Table of Contents 1.0 General Description............................................................................................ 2 1.1 Product Description ............................................................................................ 2 1.2 Related Submittal(s) Grants ............................................................................... 2 1.3 Test Methodology............................................................................................... 3 1.4 Test Facility and Test Equipment Used............................................................... 3 2.0 System Test Configuration ................................................................................. 5 2.1 Justification ........................................................................................................ 5 2.2 EUT Exercising Software.................................................................................... 5 2.3 Special Accessories ........................................................................................... 5 2.4 Equipment Modification ...................................................................................... 6 2.5 Measurement Uncertainty .................................................................................. 6 2.6 Support Equipment and Description ................................................................... 6 3.0 Emission Results ................................................................................................ 8 3.1 Field Strength Calculation................................................................................... 9 3.2 Radiated Emission Configuration Photograph................................................... 11 3.3 Radiated Emission Data ................................................................................... 12 3.4 Conducted Emission Configuration Photograph................................................ 15 3.5 Conducted Emission Data .....................................................................................16 4.0 Equipment Photographs................................................................................... 22 5.0 Product Labelling.............................................................................................. 24 6.0 Technical Specifications................................................................................... 26 7.0 Instruction Manual ............................................................................................ 28 8.0 Miscellaneous Information ............................................................................... 30 8.1 Dicussion of Pulse Desensitization ................................................................... 31 8.2 Calculation of Average Factor........................................................................... 32 8.3 Emission Test Procedures................................................................................ 33 INTERTEK TESTING SERVICES FCC ID: VVWOS200702 iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated Emission radiated photos.doc Test Setup Photo Conducted Emission conducted photos.doc External Photo External Photo external photos.doc Internal Photo Internal Photo internal photos.doc Block Diagram Block Diagram block.pdf Schematics Circuit Diagram circuit.pdf ID Label/Location Label Artwork and Location label.pdf User Manual User Manual manual.pdf INTERTEK TESTING SERVICES FCC ID: VVWOS200702 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: VVWOS200702 2 1.0 General Description 1.1 Product Description The Equipment Under Test (EUT) is an Ball Ultrasonic Humidifier which is powered by AC 120V 60Hz and operating at around 2.4MHz f…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup FCC ID : VVWOS200702 Conducted - 1 Conducted - 2 Test Setup FCC ID : VVWOS200702 Conducted - 3 Test Setup FCC ID : VVWOS200702 Radiated - front Radiated - rear

Contact Information

Applicant

Y.C. Ho
[email protected]852-24095622Fax: 852-24095733

Technical Contact

IntertekSylvia Tam
[email protected]852-2173-8452

2/F., Garment Centre · Kowloon · Hong Kong

Non-Technical Contact

IntertekSylvia Tam
[email protected]852-2173-8452

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.4 MHz - 2.4 MHz-
Confidentiality
Long Term

Other Applications from Onsource International Limited

Ultrasonic Humidifier - FCC ID VVWOS200701 - Onsource International Limited
VVWOS200701

Ultrasonic Humidifier

Jan 27, 2008

Equipment Class

8CC - Part 18 Consumer Device