Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
BioHarness 3.0 User Manual BioHarness 3.0 User Manual Page 2 of 46 Ph: +1 (443) 569-3603 Fax: +1 (443) 926-9402 Web: www.zephyanywhere.com 9700.0079 Β© Zephyr Technology 2012 2012-07-31 For support or further information on this product contact: Zephyr Technology 1 Annapolis St., Suite 200, Annapolis, MD 21401, USA Phone: +1 (443) 569 3603 Fax: +1 (443) 926 9402 Web: www.zephyranywhere.com Email: [email protected] [email protected] This document may be subject to change without notice. Version Description 2011-07-27 Initial Release 2012-03-13 Various updates to specification and completion of previous omissions 2012-04-13 Add EC38 Type 3 compliance, caution on infant use 2012-06-26 Update hardware and firmware part nos. Add 802.15.4 specifications 2012-07-03 Add new FCC ID, update battery life, label 2012-07-31 Update label, intended use 2012-08-20 Correct erroneous IC ID BioHarness 3.0 User Manual Page 3 of 46 Ph: +1 (443) 569-3603 Fax: +1 (443) 926-9402 Web: www.zephyanywhere.com 9700.0079 Β© Zephyr Technology 2012 2012-07-31 Contents 1. GENERAL INFORMATION ................................................................................................................................5 1.1. Documentation ................................................................................................................................................6 1.2. Warning and Safety Notices ...........................................................................................................................7 1.3. Intended Use ..................................................................................................................................................9 1.4. Contraindications ......................................................................................................................................... 10 1.5. Table of Symbols ......................................................................................................................................... 10 2. TECHNICAL DESCRIPTION ........................................................................................................................... 11 2.1. Model Identification ...................................................................................................................................... 11 2.2. System Overview ......................................................................................................................................... 12 2.2.1. Monitoring Mode .......................................................................................................................... 12 2.2.2. Charging and Configuration Mode ............................................................................................... 13 2.3. System Components ................................................................................................................................... 15 2.3.1. BioHarness Module ..................................................................................................................... 15 2.3.2. BioHarness Chest Strap .............................................................................................................. 16 2.3.3. BioHarness Charging and Configuration Cradle ......................................................................... 18 2.3.4. BioHarness Charge/Configuration Lead ...................................................................................... 18 2.4. Software Utilities .......................................................................................................................................... 19 2.4.1. Bluetooth Test Application ........................................................................................................... 19 2.4.2. Zephyr Config Tool ...................................................................................................................... 20 2.4.3. BioHarness Log Downloader ....................................................................................................... 20 3. OPERATION .................................................................................................................................................... 21 3.1. Overview ...................................................................................................................................................... 21 3.2. Initial Inspection ........................................................................................................................................... 22 3.3. Charge Battery ............................................................................................................................................. 23 3.4. Check BioHarness Module Configuration.................................................................................................... 24 3.4.1. Set Transmit Mode ...................................................................................................................... 24 3.4.2. Bluetooth ...................................................................................................................................... 25 3.4.3. 802.15.4 (ECHO) ......................................................................................................................... 26 3.4.4. Set Logging Mode ........................................................................................................................ 26 3.4.5. Subject ROG Thresholds ............................................................................................................. 27 3.4.6. ROG Threshold Default Values ................................................................................................... 28 3.5. Confirm Subject State .................................................................................................................................. 29 3.6. Fit BioHarness Module to Strap ..β¦
Text truncated - open the document above for the full version.
Level 2 503 Mount Wellington Highway Mount Wellington Auckland 1040 NEW ZEALAND EMC Technologies NZ Ltd PO Box 68307 Newton Auckland NEW ZEALAND 27 th July 2012 SUBJECT: Authorisation To Act. To whom it may concern I hereby authorize Andrew Cutler, General Manager of EMC Technologies NZ Ltd to act on our behalf with regard the FCC and Industry Canada Certification of the BioHarness 3 Transciever Yours sincerely Celine Coutard Compliance Engineer
Level 2, 503 Mount Wellington Highway Mount Wellington Auckland 1040 NEW ZEALAND Date 27 July 2012 Federal Communications Commission Equipment Authorisation Branch 7435 Oakland Mills Road Columbia, MD 21046 United States of America To whom it may concern CONFIDENTIALITY REQUEST Reference rule sections 0.457 (d) (ii) and pursuant to rule section 0.459 (a) confidentiality is requested as follows. Specific Information: Schematics, Block Diagram, Part List Operational Description The schematics contain trade secret information which is not made routinely available to the public or to our competitors. Disclosure of this information could result in an unfair advantage to our competitors. It should be treated as confidential for the duration of the Grant Of Authorisation. Yours Faithfully Celine Coutard Compliance Engineer
____________________________________________________________________________________________________________________________________________________________________________ Page 18 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. 9. PHOTOGRAPHS External photos
____________________________________________________________________________________________________________________________________________________________________________ Page 19 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Internal Photos Bio Harness with RF cover removed The shield is over the Bluetooth module Attached is a photo showing the locations of the transmitting antennasβ Top of the picture is the Bluetooth antenna To this side is the 802.15.4 antenna
____________________________________________________________________________________________________________________________________________________________________________ Page 1 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: [email protected] Web Site: www.emctech.com.au TEST REPORT Zephyr Technology BioHarness 3 Vital Signs Monitoring Device tested to the Code of Federal Regulations (CFR) 47 Part 15 β Radio Frequency Devices, Subpart C β Intentional Radiators Section 15.249 β Operation in the band 2400.000 β 2483.500 MHz for Zephyr Technology This Test Report is issued with the authority of: ________________________________________ Andrew Cutler - General Manager ____________________________________________________________________________________________________________________________________________________________________________ Page 2 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Table of Contents 1. STATEMENT OF COMPLIANCE 3 2. RESULTS SUMMARY 3 3. CLIENT INFORMATION 3 4. DESCRIPTION OF TEST SAMPLE 4 5. ATTESTATION 6 6. TEST RESULTS 7 7. TEST EQUIPMENT USED 17 8. ACCREDITATIONS 17 9. PHOTOGRAPHS 18 ____________________________________________________________________________________________________________________________________________________________________________ Page 3 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. 1. STATEMENT OF COMPLIANCE The Zephyr Technology BioHarness 3 Vital Signs Monitoring Device complies with 47 CFR Part 15 and in particular Sections, 15.205, 15.207, 15.209, 15.215 and 15.249 as detailed below when tested in accordance with ANSI C63.4 β 2003. 2. RESULTS SUMMARY The results of testing, carried out in May and June 2012, are listed below Clause Description Result 15.201 Equipment authorisation requirement Applied 15.203 Antenna requirement Complies 15.204 External power amplifiers Not applicable 15.205 Operation in restricted bands Complies 15.207 Conducted emissions Not applicable 15.209 Radiated emissions See below 15.215 Additional provisions Complies 15.249 (a) Field strength of fundamental Complies 15.249 (a) Field strength of harmonics Complies 15.249 (b) Fixed, point to point operations Not applicable 15.249 (c) 3 metre measurement distance Noted 15.249 (d) Spurious emission levels except harmonics Complies 15.249 (e) Detectors above 1000 MHz Noted 15.249 (f) Reference to section 15.37(d) Noted 3. CLIENT INFORMATION Company Name Zephyr Technologies Address 503 Mount Wellington Highway Mount Wellington City Auckland Country New Zealand Contact Ms Celine Courtaud ____________________________________________________________________________________________________________________________________________________________________________ Page 4 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. 4. DESCRIPTION OF TEST SAMPLE Brand Name Zephyr Technology Model Number BioHarness 3 Product Vital Signs Monitoring Device Manufacturer Zephyr Technology Country of Origin United States of America Serial Number Sample not serialized 802.15.4 FCC ID TFB-PROFLEX1 BT Module FCC ID T7V1315 New FCC ID VZ6-BH3 Band of Operation: 2400 to 2483.5 MHz 802.15.4 Band: 2405 to 2475 MHz. 15 channels with 5 MHz spacing Test Frequencies: 2405, 2440, 2475 MHz Rated Conducted Power: 0.003 W (+15 dBm) Modulation Type: GFSK, 2 Mbps data rate Bluetooth: 2402 to 2480 MHz. 79 channels with 1 MHz spacing Rated Conducted Power: Not known Antenna Type: Integral antenna Power Supply: Internal 3 Vdc battery Ports: Portable device has no external ports A Bluetooth module was utilised which has previous been tested and found to be compliant. A 802.15.4 module has been used but it has been modified by the client. The client advises that the BioHarness 802.15.4 transmitter transmits 2.5 ms of data every 2.5 seconds approximately. ____________________________________________________________________________________________________________________________________________________________________________ Page 5 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. The Zephyr Technologies BioHarness 3 system allows users to remotely monitor the physiological status of multiple subjects. Subjects wear a BioHarness on their torso using a special garment strap that allows the devices to measure heart rate and respiration rate. The BioHarness then transmits this physiological data via Bluetooth and / or 802.15.4 to a PC. The system is designed to allow users to make real-time assessments about the health and safety of teams working under strenuous and potentially hazardous conditions. The systems have applications in emergency response and defence. ____________________________________________________________________________________________________________________________________________________________________________ Page 6 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. 5. AT T E S TAT I ON This report describes the tests and measurements performed for the purpose of determining compliance with the specification with the following conditions: The client selected the test sample. The report relates only to the sample tested. This report does not contain corrections or erasures. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both Class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. In addition this equipment has been tested in accordance with the requirements contained in the appropriate Commission regulations. As the two transmitters in this device can operate simultaneously verification measurements werβ¦
Text truncated - open the document above for the full version.
____________________________________________________________________________________________________________________________________________________________________________ Page 20 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Radiated emissions test set up photos β Standing on edge Standing upright ____________________________________________________________________________________________________________________________________________________________________________ Page 21 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Standing upright β Another view Laying flat on the test table ____________________________________________________________________________________________________________________________________________________________________________ Page 20 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Radiated emissions test set up photos β Standing on edge Standing upright ____________________________________________________________________________________________________________________________________________________________________________ Page 21 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Standing upright β Another view Laying flat on the test table
____________________________________________________________________________________________________________________________________________________________________________ Page 20 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Radiated emissions test set up photos β Standing on edge Standing upright ____________________________________________________________________________________________________________________________________________________________________________ Page 21 of 21 Test Report No 120441.1 20 th June 2012 This report may not be reproduced except in full. Standing upright β Another view Laying flat on the test table
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

900 MHZ USB DONGEL RECEIVER
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter